Items - REPAIR/ REPLACEMENT OF LT CABLE NAD EXTERNAL ELECTRIC SUPPLY WITH OTHER CONNECTED ITEMS AT KALINA AND JUHU AREA UNDER GE (N) MUMBAI
Item Rate BoQ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BoQ_Ver3.1 | Item Rate | Normal | INR Only | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
Select, Excess (+), Less (-) | Less (-) | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Tender Inviting Authority: Garrison Engineer (North) Mumbai | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Name of Work: : REPAIR/ REPLACEMENT OF LT CABLE NAD EXTERNAL ELECTRIC SUPPLY WITH OTHER CONNECTED ITEMS AT KALINA AND JUHU AREA UNDER GE (N) MUMBAI | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Contract No: GE(N) M- OF 2025-2026 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Name of the Bidder/ Bidding Firm / Company : | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
PRICE SCHEDULE (BOQ DATED 22 AUG 2025) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sl. No. | Item Description | Item Code / Make | Quantity | Units | Estimated Rate in Rs. P | Addition / Deduction | Addition / Deduction Values | Currency Convertion against each Item | Quoted Currency in INR / Other Currency | BASIC RATE In Figures To be entered by the Bidder Rs. P | Excise Duty | VAT | Freight Charges ( Unloading & Stacking) | Any Other Taxes/Duties/Levies | Other Taxes 2 | IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax | Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category | TOTAL AMOUNT in Rs. P | TOTAL AMOUNT | TOTAL AMOUNT In Words | ||||||||||||||||||||||||||||||||||
1 | 2 | 3 | 3 | 4 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 5 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 | 51 | 52 | 8 | 6 | 7 |
1 | Excavation in trenches, not exceeding 1.50 m wide and not exceeding 1.5 m in depth, for foundation, laying of cables/pipes etc and getting out in hard/dense soil complete all as specified and as directed by Engineer-in-Charge. | 208.00 | CUBIC METRE | 100.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 1 | Excavation in trenches, not exceeding 1.50 m wide and not exceeding 1.5 m in depth, for foundation, laying of cables/pipes etc and getting out in hard/dense soil complete all as specified and as directed by Engineer-in-Charge. | 208 | CUBIC METRE | |||||||||||||||||||||||||||||||||||||||
2 | Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25cm in soil complete all as specified and as directed by Engineer-in-Charge. | 137.00 | CUBIC METRE | 100.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25cm in soil complete all as specified and as directed by Engineer-in-Charge. | 137 | CUBIC METRE | |||||||||||||||||||||||||||||||||||||||
3 | Removing excavated material to a distance, not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge | 70.00 | CUBIC METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 3 | Removing excavated material to a distance, not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge | 70 | CUBIC METRE | |||||||||||||||||||||||||||||||||||||||
4 | Supply and lay double wall corrugated (DWC) HDPE pipe 63mm outer dia , as per IS-16205 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed by Engineer-in-Charge Make : TELEREX 450N/ Rex Polyextrusion Ltd/ Finolex/ Prince Pipes and fittings ltd/Kisan/Supreme/JAIN IRRIGATION SYS/ Astral | 250.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 4 | Supply and lay double wall corrugated (DWC) HDPE pipe 63mm outer dia , as per IS-16205 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed by Engineer-in-Charge Make : TELEREX 450N/ Rex Polyextrusion Ltd/ Finolex/ Prince Pipes and fittings ltd/Kisan/Supreme/JAIN IRRIGATION SYS/ Astral | 250 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
5 | Supply and lay double wall corrugated (DWC) HDPE pipe 40mm outer dia , as per IS-16205 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed by Engineer-in-Charge Make : TELEREX 450N/ Rex Polyextrusion Ltd/ Finolex/ Prince Pipes and fittings ltd/Kisan/Supreme/JAIN IRRIGATION SYS/ Astral | 250.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 5 | Supply and lay double wall corrugated (DWC) HDPE pipe 40mm outer dia , as per IS-16205 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed by Engineer-in-Charge Make : TELEREX 450N/ Rex Polyextrusion Ltd/ Finolex/ Prince Pipes and fittings ltd/Kisan/Supreme/JAIN IRRIGATION SYS/ Astral | 250 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
6 | Supply and lay double wall corrugated (DWC) HDPE pipe 90mm outer dia , as per IS-16205 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed by Engineer-in-Charge Make : TELEREX 450N/ Rex Polyextrusion Ltd/ Finolex/ Prince Pipes and fittings ltd/Kisan/Supreme/JAIN IRRIGATION SYS/ Astral | 275.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 6 | Supply and lay double wall corrugated (DWC) HDPE pipe 90mm outer dia , as per IS-16205 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed by Engineer-in-Charge Make : TELEREX 450N/ Rex Polyextrusion Ltd/ Finolex/ Prince Pipes and fittings ltd/Kisan/Supreme/JAIN IRRIGATION SYS/ Astral | 275 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
7 | Supplying, laying,connecting, testing & commissioning LT UG XLPE insulated, heavy duty, 1100 V grade electric cable with aluminium conductor, served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size 10 Sqmm x 2 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:- Note : Earthwork excavation, DWC/GI pipe for cable protection shall be measured and paid separately in their respective items Make: Cable Corporation of India (CCI)/ Asian Cable Co, Chattisgarh/ Finolex/ Polycab/ Gloster/Universal/ RPG Cables Ltd , Thane/ Havells India Ltd/ RR Kabel/ KEI Industries Ltd(KEI) | 80.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 7 | Supplying, laying,connecting, testing & commissioning LT UG XLPE insulated, heavy duty, 1100 V grade electric cable with aluminium conductor, served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size 10 Sqmm x 2 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:- Note : Earthwork excavation, DWC/GI pipe for cable protection shall be measured and paid separately in their respective items Make: Cable Corporation of India (CCI)/ Asian Cable Co, Chattisgarh/ Finolex/ Polycab/ Gloster/Universal/ RPG Cables Ltd , Thane/ Havells India Ltd/ RR Kabel/ KEI Industries Ltd(KEI) | 80 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
8 | -do- same as Item no. 7 above but of size 10 Sqmm 4 Core | 150.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 8 | -do- same as Item no. 7 above but of size 10 Sqmm 4 Core | 150 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
9 | -do- same as Item no. 7 above but of size 16 Sqmm 4 Core | 100.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 9 | -do- same as Item no. 7 above but of size 16 Sqmm 4 Core | 100 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
10 | -do- same as Item no. 7 above but of size 50 Sqmm 3.5 Core | 250.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 10 | -do- same as Item no. 7 above but of size 50 Sqmm 3.5 Core | 250 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
11 | -do- same as Item no. 7 above but of size 120 Sqmm 3.5 Core | 50.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 11 | -do- same as Item no. 7 above but of size 120 Sqmm 3.5 Core | 50 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
12 | -do- same as Item no. 7 above but of size 150 Sqmm 3.5 Core | 50.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 12 | -do- same as Item no. 7 above but of size 150 Sqmm 3.5 Core | 50 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
13 | -do- same as Item no. 7 above but of size 185 Sqmm 3.5 Core | 175.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 13 | -do- same as Item no. 7 above but of size 185 Sqmm 3.5 Core | 175 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
14 | Supply and fix in repairs galvanised iron pipe, medium grade, 50mm bore for cable protection on wall, trenches, road crossings etc. with suitable size of GI saddle, wherever necessary complete all as specified and as directed by Engineer-in-Charge. Make: TATA/SWASTIK/JINDAL/Bharat Steel tube/ZENITH/Indian Tube Company | 12.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 14 | Supply and fix in repairs galvanised iron pipe, medium grade, 50mm bore for cable protection on wall, trenches, road crossings etc. with suitable size of GI saddle, wherever necessary complete all as specified and as directed by Engineer-in-Charge. Make: TATA/SWASTIK/JINDAL/Bharat Steel tube/ZENITH/Indian Tube Company | 12 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
15 | Supply and fix in repairs galvanised iron pipe, medium grade, 80mm bore for cable protection on wall, trenches, road crossings etc. with suitable size of GI saddle, wherever necessary complete all as specified and as directed by Engineer-in-Charge. Make: TATA/SWASTIK/JINDAL/Bharat Steel tube/ZENITH/Indian Tube Company | 12.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 15 | Supply and fix in repairs galvanised iron pipe, medium grade, 80mm bore for cable protection on wall, trenches, road crossings etc. with suitable size of GI saddle, wherever necessary complete all as specified and as directed by Engineer-in-Charge. Make: TATA/SWASTIK/JINDAL/Bharat Steel tube/ZENITH/Indian Tube Company | 12 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
16 | Material and labour for straight Through Heat shrinkable type Cable Joint Kit including Jointing Materials for making Joints of LT UG Electric Cable 1100 Volt Grade Heavy Duty with XLPE insulated Aluminium Stranded Conductor of size 50 to 95 Sqmm x 3½ Core and Testing complete all as specified and as directed. Make: Densons/ M Seal/ Raychem/ Siemens / Birla 3M/ Mahindra & Mahindra | 2.00 | EACH | 100.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 16 | Material and labour for straight Through Heat shrinkable type Cable Joint Kit including Jointing Materials for making Joints of LT UG Electric Cable 1100 Volt Grade Heavy Duty with XLPE insulated Aluminium Stranded Conductor of size 50 to 95 Sqmm x 3½ Core and Testing complete all as specified and as directed. Make: Densons/ M Seal/ Raychem/ Siemens / Birla 3M/ Mahindra & Mahindra | 2 | EACH | |||||||||||||||||||||||||||||||||||||||
17 | Material and labour for straight Through Heat shrinkable type Cable Joint Kit including Jointing Materials for making Joints of LT UG Electric Cable 1100 Volt Grade Heavy Duty with XLPE insulated Aluminium Stranded Conductor of size 120 to 185 Sqmm x 3½ Core and Testing complete all as specified and as directed. Make: Densons/ M Seal/ Raychem/ Siemens / Birla 3M/ Mahindra & Mahindra | 2.00 | EACH | 100.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 17 | Material and labour for straight Through Heat shrinkable type Cable Joint Kit including Jointing Materials for making Joints of LT UG Electric Cable 1100 Volt Grade Heavy Duty with XLPE insulated Aluminium Stranded Conductor of size 120 to 185 Sqmm x 3½ Core and Testing complete all as specified and as directed. Make: Densons/ M Seal/ Raychem/ Siemens / Birla 3M/ Mahindra & Mahindra | 2 | EACH | |||||||||||||||||||||||||||||||||||||||
18 | Material and labour for straight Through Heat shrinkable type Cable Joint Kit including Jointing Materials for making Joints of LT UG Electric Cable 1100 Volt Grade Heavy Duty with XLPE insulated Aluminium Stranded Conductor of size 240 to 300 Sqmm x 3½ Core and Testing complete all as specified and as directed. Make: Densons/ M Seal/ Raychem/ Siemens / Birla 3M/ Mahindra & Mahindra | 2.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 18 | Material and labour for straight Through Heat shrinkable type Cable Joint Kit including Jointing Materials for making Joints of LT UG Electric Cable 1100 Volt Grade Heavy Duty with XLPE insulated Aluminium Stranded Conductor of size 240 to 300 Sqmm x 3½ Core and Testing complete all as specified and as directed. Make: Densons/ M Seal/ Raychem/ Siemens / Birla 3M/ Mahindra & Mahindra | 2 | EACH | |||||||||||||||||||||||||||||||||||||||
19 | Material and labour for finding cable fault with electronic fault detector in LT UG cable of size upto 300 sqmm x 3.5 core complete including necessary earth work excavation all as specified and as directed by Engineer-in-Charge. | 2.00 | EACH JOB | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 19 | Material and labour for finding cable fault with electronic fault detector in LT UG cable of size upto 300 sqmm x 3.5 core complete including necessary earth work excavation all as specified and as directed by Engineer-in-Charge. | 2 | EACH JOB | |||||||||||||||||||||||||||||||||||||||
20 | Supply and fix in repairs MCCBs 100/125 Amps, 16 KA, 4 pole, 415 Volts with adjustable thermal and adjustable magnetic settings with extended copper terminals complete all as specified and as directed by Engineer-in-Charge. Make : Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ BhartiaCuttler Hammer (BCH)/Benlo | 2.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 20 | Supply and fix in repairs MCCBs 100/125 Amps, 16 KA, 4 pole, 415 Volts with adjustable thermal and adjustable magnetic settings with extended copper terminals complete all as specified and as directed by Engineer-in-Charge. Make : Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ BhartiaCuttler Hammer (BCH)/Benlo | 2 | EACH | |||||||||||||||||||||||||||||||||||||||
21 | Supply and fix in repairs MCCBs 160 Amps, 36 KA, 4 pole, 415 Volts with adjustable thermal and adjustable magnetic settings with extended copper terminals complete all as specified and as directed by Engineer-in-Charge. Make : Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ BhartiaCuttler Hammer (BCH)/Benlo | 1.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 21 | Supply and fix in repairs MCCBs 160 Amps, 36 KA, 4 pole, 415 Volts with adjustable thermal and adjustable magnetic settings with extended copper terminals complete all as specified and as directed by Engineer-in-Charge. Make : Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ BhartiaCuttler Hammer (BCH)/Benlo | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
22 | Supply and fix in repairs MCCBs 250 Amps, 36 KA, 4 pole, 415 Volts with adjustable thermal and adjustable magnetic settings with extended copper terminals complete all as specified and as directed by Engineer-in-Charge. Make : Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ BhartiaCuttler Hammer (BCH)/Benlo | 1.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 22 | Supply and fix in repairs MCCBs 250 Amps, 36 KA, 4 pole, 415 Volts with adjustable thermal and adjustable magnetic settings with extended copper terminals complete all as specified and as directed by Engineer-in-Charge. Make : Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ BhartiaCuttler Hammer (BCH)/Benlo | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
23 | Supply and fix Current Transformer of ratio 300/5A with frequency 50Hz, class 1.0 voltage ranging upto 660 Volts, having long life expectancy, shock hazard including taking down old unserviceable Current Transformer complete all as specified and directed by Engr-in-Charge. Make- Schneider, L&T, Siemens, AE, Crompton Greeves, Mumbai | 2.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 23 | Supply and fix Current Transformer of ratio 300/5A with frequency 50Hz, class 1.0 voltage ranging upto 660 Volts, having long life expectancy, shock hazard including taking down old unserviceable Current Transformer complete all as specified and directed by Engr-in-Charge. Make- Schneider, L&T, Siemens, AE, Crompton Greeves, Mumbai | 2 | EACH | |||||||||||||||||||||||||||||||||||||||
24 | Supplying, installing, testing and commissioning LT feeder pillar box of suitable size factory made outdoor type, dust and vermin proof, double door, cubical and compartmentalized type, 415 volts, AC, 50 Hz, fabricated with 3 mm thick CRCA sheet complete with and including mounted on angle iron frame stand of size 40 x 40 x 6 mm thick, 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, powder coated of approved colour by Engineer-in-Charge, enclosed bus bar chamber with aluminium bus bar of size 40x10mm for phases and neutral (04 Nos of rating capacity 400 Amps), mounted on PVC insulators, electric connection complete with from MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement complete electrically inter connected with Aluminium strips of suitable size for all incoming and outgoing MCCBs and accessories with fixing arrangement on PCC (1:3:6) type C-2 bed block with studs, bolts, nuts & washers, Danger notice board with scull suitable for 415 volts or required size to be fixed on Pannel and consisting of the following accessories including dismantling of old panel all as directed. (a) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-Charge (b) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set (c) Digital type Ammeter 0 - 100 Amps with CT including selector switch - 01 No. (d) Digital type Voltmeter 0 - 500 V with selector switch - 01 No. (e) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (f) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (g) Necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor- 01 Job (h) All incoming/ outgoing feeders to be marked with suitable size of stencils as directed. | 1.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 24 | Supplying, installing, testing and commissioning LT feeder pillar box of suitable size factory made outdoor type, dust and vermin proof, double door, cubical and compartmentalized type, 415 volts, AC, 50 Hz, fabricated with 3 mm thick CRCA sheet complete with and including mounted on angle iron frame stand of size 40 x 40 x 6 mm thick, 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, powder coated of approved colour by Engineer-in-Charge, enclosed bus bar chamber with aluminium bus bar of size 40x10mm for phases and neutral (04 Nos of rating capacity 400 Amps), mounted on PVC insulators, electric connection complete with from MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement complete electrically inter connected with Aluminium strips of suitable size for all incoming and outgoing MCCBs and accessories with fixing arrangement on PCC (1:3:6) type C-2 bed block with studs, bolts, nuts & washers, Danger notice board with scull suitable for 415 volts or required size to be fixed on Pannel and consisting of the following accessories including dismantling of old panel all as directed. (a) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-Charge (b) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set (c) Digital type Ammeter 0 - 100 Amps with CT including selector switch - 01 No. (d) Digital type Voltmeter 0 - 500 V with selector switch - 01 No. (e) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (f) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (g) Necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor- 01 Job (h) All incoming/ outgoing feeders to be marked with suitable size of stencils as directed. | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
24.1 | (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No (b) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 125 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos (c) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos Make of MCCB: Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH) | 24.1 | (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No (b) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 125 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos (c) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos Make of MCCB: Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH) | |||||||||||||||||||||||||||||||||||||||||||||||||||
25 | Supplying, installing, testing and commissioning LT feeder pillar box of suitable size factory made outdoor type, dust and vermin proof, double door, cubical and compartmentalized type, 415 volts, AC, 50 Hz, fabricated with 3 mm thick CRCA sheet complete with and including mounted on angle iron frame stand of size 40 x 40 x 6 mm thick, 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, powder coated of approved colour by Engineer-in-Charge, enclosed bus bar chamber with aluminium bus bar of size 40x10mm for phases and neutral (04 Nos of rating capacity 400 Amps), mounted on PVC insulators, electric connection complete with from MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement complete electrically inter connected with Aluminium strips of suitable size for all incoming and outgoing MCCBs and accessories with fixing arrangement on PCC (1:3:6) type C-2 bed block with studs, bolts, nuts & washers, Danger notice board with scull suitable for 415 volts or required size to be fixed on Pannel and consisting of the following accessories including dismantling of old panel all as directed. (a) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-Charge (b) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set (c) Digital type Ammeter 0 - 100 Amps with CT including selector switch - 01 No. (d) Digital type Voltmeter 0 - 500 V with selector switch - 01 No. (e) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (f) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (g) Necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor- 01 Job (h) All incoming/ outgoing feeders to be marked with suitable size of stencils as directed. | 2.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 25 | Supplying, installing, testing and commissioning LT feeder pillar box of suitable size factory made outdoor type, dust and vermin proof, double door, cubical and compartmentalized type, 415 volts, AC, 50 Hz, fabricated with 3 mm thick CRCA sheet complete with and including mounted on angle iron frame stand of size 40 x 40 x 6 mm thick, 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, powder coated of approved colour by Engineer-in-Charge, enclosed bus bar chamber with aluminium bus bar of size 40x10mm for phases and neutral (04 Nos of rating capacity 400 Amps), mounted on PVC insulators, electric connection complete with from MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement complete electrically inter connected with Aluminium strips of suitable size for all incoming and outgoing MCCBs and accessories with fixing arrangement on PCC (1:3:6) type C-2 bed block with studs, bolts, nuts & washers, Danger notice board with scull suitable for 415 volts or required size to be fixed on Pannel and consisting of the following accessories including dismantling of old panel all as directed. (a) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-Charge (b) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set (c) Digital type Ammeter 0 - 100 Amps with CT including selector switch - 01 No. (d) Digital type Voltmeter 0 - 500 V with selector switch - 01 No. (e) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (f) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (g) Necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor- 01 Job (h) All incoming/ outgoing feeders to be marked with suitable size of stencils as directed. | 2 | EACH | |||||||||||||||||||||||||||||||||||||||
25.1 | (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No (b) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 125 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No (c) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos (d) MCB SPN 63 Amps, 240 volts, 10KA 'C' curve- 04 Nos (e) Timer switch 4 Pole 415 Volts with ML-2 Contactor-01 No Make of MCCB/MCB: Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH) | 25.1 | (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No (b) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 125 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No (c) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos (d) MCB SPN 63 Amps, 240 volts, 10KA 'C' curve- 04 Nos (e) Timer switch 4 Pole 415 Volts with ML-2 Contactor-01 No Make of MCCB/MCB: Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH) | |||||||||||||||||||||||||||||||||||||||||||||||||||
26 | Material and labour for earthing complete with Galvanised steel earth plate electrode 60cm X 60cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to plate with GI earth wire 32 x 6mm GI earth strip, 7.5m long from earth point to test point and other end connected to control board / panel / equipment, laid under floors/plinths or fixed on walls or concealed in wall etc by means of bolts, nuts, check nuts and washers made out of galvanized iron or steel with provision of charcoal & common salt not less than 50Kg, in each earthing packed up to maximum 30 cm on both side of plate and GI strip protected by 40mm bore light grade galvanized iron pipe, MS funnel, PCC chamber in cement concrete 1:3:6 type C1 and finished even and smooth without using extra cement, 50 mm thick RCC cover 1:2:4 type B1 including 10 mm dia deformed bars @100 mm c/c on both ways for full size of chamber complete all as per electrical plate No 3 and engraving of earth marking on nearby structure/ building with cement mortar 1:4 plate of size 200mm x 150mm x 15mm thick including necessary excavation and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Contractor should submit test report of earthing after installation to Engineer -in-Charge | 10.00 | EACH JOB | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 26 | Material and labour for earthing complete with Galvanised steel earth plate electrode 60cm X 60cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to plate with GI earth wire 32 x 6mm GI earth strip, 7.5m long from earth point to test point and other end connected to control board / panel / equipment, laid under floors/plinths or fixed on walls or concealed in wall etc by means of bolts, nuts, check nuts and washers made out of galvanized iron or steel with provision of charcoal & common salt not less than 50Kg, in each earthing packed up to maximum 30 cm on both side of plate and GI strip protected by 40mm bore light grade galvanized iron pipe, MS funnel, PCC chamber in cement concrete 1:3:6 type C1 and finished even and smooth without using extra cement, 50 mm thick RCC cover 1:2:4 type B1 including 10 mm dia deformed bars @100 mm c/c on both ways for full size of chamber complete all as per electrical plate No 3 and engraving of earth marking on nearby structure/ building with cement mortar 1:4 plate of size 200mm x 150mm x 15mm thick including necessary excavation and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Contractor should submit test report of earthing after installation to Engineer -in-Charge | 10 | EACH JOB | |||||||||||||||||||||||||||||||||||||||
27 | Supply and fix GI strip 32mmX6 mm buried in ground/on wall, extension of existing earthing lead complete all as per specified and directed by Engineer - in - charge. | 18.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 27 | Supply and fix GI strip 32mmX6 mm buried in ground/on wall, extension of existing earthing lead complete all as per specified and directed by Engineer - in - charge. | 18 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
28 | Material and labour for cutting or cutting the existing Bitumen Road /hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6 type C1 using 20mm graded aggregate complete all as specified and directed. | 18.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 28 | Material and labour for cutting or cutting the existing Bitumen Road /hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6 type C1 using 20mm graded aggregate complete all as specified and directed. | 18 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
29 | Material & Labour for cleaning of E/M installations / campus, surface dressing or trimming of branches of trees, cutting/ dressing of natural grass from ground to remove small unequalities, n.exc 15 cm deep ( including removing vegetation / shrubs / brush wood / under-growth ), earth heaps, cleaning of drains & carrying away the rubbish to a distance of n.exc 50 mtr away complete, the area of each installation up to 700sqm. at least 2 times in each installation at a interval of 3 months complete all as specified and directed by Engr-in-Charge. Note- Quoted rate is for each installation | 9.00 | EACH JOB | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 29 | Material & Labour for cleaning of E/M installations / campus, surface dressing or trimming of branches of trees, cutting/ dressing of natural grass from ground to remove small unequalities, n.exc 15 cm deep ( including removing vegetation / shrubs / brush wood / under-growth ), earth heaps, cleaning of drains & carrying away the rubbish to a distance of n.exc 50 mtr away complete, the area of each installation up to 700sqm. at least 2 times in each installation at a interval of 3 months complete all as specified and directed by Engr-in-Charge. Note- Quoted rate is for each installation | 9 | EACH JOB | |||||||||||||||||||||||||||||||||||||||
30 | Repair/maint of Capacitor bank APFC panel of 66 to 100 KVAr, disconnecting and taking out U/S LV capacitors, Protection brunch, Cooling fan, connectors, Power contactors, Controller etc from housing and including fixing new above items, all connection and testing to maint PF above 0.95 complete all as specified and directed by Engineer-in-Charge. Note: Capacitors and other items shall be measured and paid separately in respective items. | 1.00 | EACH JOB | 100.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 30 | Repair/maint of Capacitor bank APFC panel of 66 to 100 KVAr, disconnecting and taking out U/S LV capacitors, Protection brunch, Cooling fan, connectors, Power contactors, Controller etc from housing and including fixing new above items, all connection and testing to maint PF above 0.95 complete all as specified and directed by Engineer-in-Charge. Note: Capacitors and other items shall be measured and paid separately in respective items. | 1 | EACH JOB | |||||||||||||||||||||||||||||||||||||||
31 | Supply only heavy duty Power capacitors bank 25 KVAR, cylindrical type, suitable for 440 Volt AC,3 phase ,50 Hz confirming to IS:13340-1993 complete all as specified and directed by Engineer-in-Charge. Make: L&T / Havells / Schneider / ABB / Legrand / Siemens / Epcos | 1.00 | EACH | 100.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 31 | Supply only heavy duty Power capacitors bank 25 KVAR, cylindrical type, suitable for 440 Volt AC,3 phase ,50 Hz confirming to IS:13340-1993 complete all as specified and directed by Engineer-in-Charge. Make: L&T / Havells / Schneider / ABB / Legrand / Siemens / Epcos | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
32 | All as per item No 31 described here-in-before but of capacity 15 KVAR | 1.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 32 | All as per item No 31 described here-in-before but of capacity 15 KVAR | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
33 | All as per item No 31 described here-in-before but of capacity 10 KVAR | 1.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 33 | All as per item No 31 described here-in-before but of capacity 10 KVAR | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
34 | All as per item No 31 described here-in-before but of capacity 5 KVAR | 1.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 34 | All as per item No 31 described here-in-before but of capacity 5 KVAR | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
35 | Supply only capacitor duty contactor 3 phase, 415V,suitable for 7.5/5 KVAR rating capacitor. Make :L&T, model: MO C05 or equivalent. | 1.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 35 | Supply only capacitor duty contactor 3 phase, 415V,suitable for 7.5/5 KVAR rating capacitor. Make :L&T, model: MO C05 or equivalent. | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
36 | Supply only capacitor duty contactor 3 phase, 415V,suitable for 10 KVAR rating capacitor. Make :L&T, model: MO C10 or equivalent. | 1.00 | EACH | 100.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 36 | Supply only capacitor duty contactor 3 phase, 415V,suitable for 10 KVAR rating capacitor. Make :L&T, model: MO C10 or equivalent. | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
37 | Supply only capacitor duty contactor 3 phase, 415V,suitable for 15 KVAR rating capacitor. Make :L&T, model: MO C15 or equivalent. | 1.00 | EACH | 100.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 37 | Supply only capacitor duty contactor 3 phase, 415V,suitable for 15 KVAR rating capacitor. Make :L&T, model: MO C15 or equivalent. | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
38 | Supply only Current Transformer having Ratio 200/5, 15 VA Make- Larsen &Tubro/ Siemens/ ABB/ Schneider | 3.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 38 | Supply only Current Transformer having Ratio 200/5, 15 VA Make- Larsen &Tubro/ Siemens/ ABB/ Schneider | 3 | EACH | |||||||||||||||||||||||||||||||||||||||
39 | Material & Labour for painting the old Main LT panel board including scrapping and removing the old painted surfaces and painting /matching the same colour paint with two coats of super enameled paint ( Smoke grey) and without distrubing the existing electric system all as specified and directed by Engineer-in-Charge. Make : Asian Paints/ Nerolac Paints/ Dulux ( Akzonobel)/ Nippon Paint India Pvt Ltd | 8.00 | EACH JOB | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 39 | Material & Labour for painting the old Main LT panel board including scrapping and removing the old painted surfaces and painting /matching the same colour paint with two coats of super enameled paint ( Smoke grey) and without distrubing the existing electric system all as specified and directed by Engineer-in-Charge. Make : Asian Paints/ Nerolac Paints/ Dulux ( Akzonobel)/ Nippon Paint India Pvt Ltd | 8 | EACH JOB | |||||||||||||||||||||||||||||||||||||||
40 | Material & Labour for labour for welding broken doors of LT Panel (front and rear door) including replacing the required new hinges, nuts and bolts, locking arrangement and refixing the covers without disturbing the existing electric system complete all as specified and directed by Engr-in-charge. | 3.00 | EACH JOB | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 40 | Material & Labour for labour for welding broken doors of LT Panel (front and rear door) including replacing the required new hinges, nuts and bolts, locking arrangement and refixing the covers without disturbing the existing electric system complete all as specified and directed by Engr-in-charge. | 3 | EACH JOB | |||||||||||||||||||||||||||||||||||||||
41 | Decarbonising of LT panel board/ Feeder pillar boxes by CTC (Carbon Tetra Chloride) removing the carbon deposited inside the panel, cleaning the panel with cotton waste, applying one coat of becktol red solution, checking the fault inside the panel board, charging the LT panel post completion of decarbonisation complete all as specified and directed by Engr-in-charge.. | 15.00 | EACH JOB | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 41 | Decarbonising of LT panel board/ Feeder pillar boxes by CTC (Carbon Tetra Chloride) removing the carbon deposited inside the panel, cleaning the panel with cotton waste, applying one coat of becktol red solution, checking the fault inside the panel board, charging the LT panel post completion of decarbonisation complete all as specified and directed by Engr-in-charge.. | 15 | EACH JOB | |||||||||||||||||||||||||||||||||||||||
42 | Supply and fix aluminium bus bar chamber 100 Amps 4 pole 415 volts with all fixing accessories etc complete all as specified and as directed by Engineer-in-Charge. Make : C&S / Havells / L&T / Legrand/ Siemens/ ABB/ Crompton Greaves | 2.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 42 | Supply and fix aluminium bus bar chamber 100 Amps 4 pole 415 volts with all fixing accessories etc complete all as specified and as directed by Engineer-in-Charge. Make : C&S / Havells / L&T / Legrand/ Siemens/ ABB/ Crompton Greaves | 2 | EACH | |||||||||||||||||||||||||||||||||||||||
43 | Supply and laying for cable in trenches or passing through pipe or on wall by saddling XLPE insulated, heavy duty, 1100 V grade electric cable with aluminium conductor, balance stranded copper, PVC inner sheathed for 1100 volts grade of size 16 sqmm 4 core including taking down complete all as specified and as directed by Engineer-in-Charge. Make: Cable Corporation of India (CCI)/ Asian Cable Co, Chattisgarh/ Finolex/ Polycab/ Gloster/Universal/ RPG Cables Ltd , Thane/ Havells India Ltd/ RR Kabel/ KEI Industries Ltd(KEI) | 35.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 43 | Supply and laying for cable in trenches or passing through pipe or on wall by saddling XLPE insulated, heavy duty, 1100 V grade electric cable with aluminium conductor, balance stranded copper, PVC inner sheathed for 1100 volts grade of size 16 sqmm 4 core including taking down complete all as specified and as directed by Engineer-in-Charge. Make: Cable Corporation of India (CCI)/ Asian Cable Co, Chattisgarh/ Finolex/ Polycab/ Gloster/Universal/ RPG Cables Ltd , Thane/ Havells India Ltd/ RR Kabel/ KEI Industries Ltd(KEI) | 35 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
44 | Supply and laying for cable in trenches or passing through pipe or on wall by saddling XLPE insulated, heavy duty, 1100 V grade electric cable with aluminium conductor, balance stranded copper, PVC inner sheathed for 1100 volts grade of size 1.5 sqmm 3 core including taking down complete all as specified and as directed by Engineer-in-Charge. Make: Cable Corporation of India (CCI)/ Asian Cable Co, Chattisgarh/ Finolex/ Polycab/ Gloster/Universal/ RPG Cables Ltd , Thane/ Havells India Ltd/ RR Kabel/ KEI Industries Ltd(KEI) | 75.00 | RUNNING METRE | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 44 | Supply and laying for cable in trenches or passing through pipe or on wall by saddling XLPE insulated, heavy duty, 1100 V grade electric cable with aluminium conductor, balance stranded copper, PVC inner sheathed for 1100 volts grade of size 1.5 sqmm 3 core including taking down complete all as specified and as directed by Engineer-in-Charge. Make: Cable Corporation of India (CCI)/ Asian Cable Co, Chattisgarh/ Finolex/ Polycab/ Gloster/Universal/ RPG Cables Ltd , Thane/ Havells India Ltd/ RR Kabel/ KEI Industries Ltd(KEI) | 75 | RUNNING METRE | |||||||||||||||||||||||||||||||||||||||
45 | Supply & Fix LED Indicating lamp of main supply indicating 'R', 'Y', 'B' (set of three) complete all as directed by engr-in-charge Make- Larsen &Tubro/ Siemens/ ABB/ Schneider/ Japuria/ EPCOS | 8.00 | SET OF 3 | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 45 | Supply & Fix LED Indicating lamp of main supply indicating 'R', 'Y', 'B' (set of three) complete all as directed by engr-in-charge Make- Larsen &Tubro/ Siemens/ ABB/ Schneider/ Japuria/ EPCOS | 8 | SET OF 3 | |||||||||||||||||||||||||||||||||||||||
46 | Supply and fix in repairs of Ammeter, digital type, 0-800 Amps, AC CT operated, suitable for three phase with selector switch complete all as specified and as directed by Engineer-in-Charge. Make: AE/ Schneider/ L&T | 4.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 46 | Supply and fix in repairs of Ammeter, digital type, 0-800 Amps, AC CT operated, suitable for three phase with selector switch complete all as specified and as directed by Engineer-in-Charge. Make: AE/ Schneider/ L&T | 4 | EACH | |||||||||||||||||||||||||||||||||||||||
47 | Supply and fix in repairs of voltmeter, 0 to 500 Volts, AC, suitable for three phase, digital type with selector switch complete all as specified and as directed by Engineer-in-Charge. Make: AE/Schneider/L&T | 4.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 47 | Supply and fix in repairs of voltmeter, 0 to 500 Volts, AC, suitable for three phase, digital type with selector switch complete all as specified and as directed by Engineer-in-Charge. Make: AE/Schneider/L&T | 4 | EACH | |||||||||||||||||||||||||||||||||||||||
48 | Material & Labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed by Engineer-in-Charge. | 8.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 48 | Material & Labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed by Engineer-in-Charge. | 8 | EACH | |||||||||||||||||||||||||||||||||||||||
49 | Supplying, installing, testing and commissioning in replacement of Automatic Power Factor Correction (APFC) panel outdoor type factory made of 120 KVAR capacity, ready to use design, conforming to IS 5039/ IS 8623 and relevant IS/ IEC Codes rated for short circuit rating of 35 KA, front openable and lockable by keys having louvers and air vent, gasket and totally vermin proof and suitable for 415/440 V, 3 phase 50 Hz, AC and housed in elegant enclosure fabricated from minimum 3.15 mm thick CRCA sheet and min 1.6 mm thick for partitions, anti corrosive coating to improve power factor to 0.99 and finally powder coated in texture siemens grey RAL 7032 & as directed by Engineer-in-Charge comprising of and including following including suitable size and length of copper conductor cable PVC insulated, from main panel to APFC panel for connections as approved:- (a) 400 Amp capacity for phase and 200 amps for neutral, Copper bus bar duly insulated with colour coaded heat shrinkable sleeves and mounted on suitable DMC/epoxy insulators. (b) A set of heavy duty, capacitor, type MPP, 440 volts, box type, with output 120 KVAR capacity, capacitor bank in steps of 5/10/25/50 KVAR in any configuration to accommodate all possible set ups. (c) MCCB's/MCB's TP, 'C' series, 415 volts, of required sizes with required numbers and suitable ratings as per the capacity of capacitors . (d) Micro processr based control suitable for power factor correction with its unique features of four quadrant operation automatic C/K ratio selection. The APFC controller should ON/OFF the capacitor banks of 120 KVAR capacity capacitor bank in steps of 5/10/25/50 KVAR in any configuration to accommodate all possible set ups with indication whether it is lagging or leading. | 1.00 | EACH | 10.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 49 | Supplying, installing, testing and commissioning in replacement of Automatic Power Factor Correction (APFC) panel outdoor type factory made of 120 KVAR capacity, ready to use design, conforming to IS 5039/ IS 8623 and relevant IS/ IEC Codes rated for short circuit rating of 35 KA, front openable and lockable by keys having louvers and air vent, gasket and totally vermin proof and suitable for 415/440 V, 3 phase 50 Hz, AC and housed in elegant enclosure fabricated from minimum 3.15 mm thick CRCA sheet and min 1.6 mm thick for partitions, anti corrosive coating to improve power factor to 0.99 and finally powder coated in texture siemens grey RAL 7032 & as directed by Engineer-in-Charge comprising of and including following including suitable size and length of copper conductor cable PVC insulated, from main panel to APFC panel for connections as approved:- (a) 400 Amp capacity for phase and 200 amps for neutral, Copper bus bar duly insulated with colour coaded heat shrinkable sleeves and mounted on suitable DMC/epoxy insulators. (b) A set of heavy duty, capacitor, type MPP, 440 volts, box type, with output 120 KVAR capacity, capacitor bank in steps of 5/10/25/50 KVAR in any configuration to accommodate all possible set ups. (c) MCCB's/MCB's TP, 'C' series, 415 volts, of required sizes with required numbers and suitable ratings as per the capacity of capacitors . (d) Micro processr based control suitable for power factor correction with its unique features of four quadrant operation automatic C/K ratio selection. The APFC controller should ON/OFF the capacitor banks of 120 KVAR capacity capacitor bank in steps of 5/10/25/50 KVAR in any configuration to accommodate all possible set ups with indication whether it is lagging or leading. | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
49.1 | (e) Contactors, 415V, air break type shall be provided for connecting /disconnecting the capacitor banks to the bus bar. (f) The APFC panel provided with two existing terminal and it is connected through GI strip 32 x 6mm size to existing transformer earthing/panel earthing all as specified and directed. (g) Digital panel meter for current,voltage/ frequency and power factor having suitable CT ratio and built in selector switch of size 96mmx96mm,accuracy class-I, shall be provided. (h) All control wires shall be not less than 2.5 sqmm multistranded copper conductor and propeperly bunched/ tied,ferruled for proper identification and crimpled with adequate size of lugs etc complete all as directed. (j) Auto/ Manual switch-01 No. (k) Fuse for line protection as per requirement and as approved (l) Indicator lamp LED based with lamp holder as per requirement and as approved (m) Current transformer (CT) of ratio 400/5 A , measuring class accuracy 0.5 to 1.0 for capacitor panel. (n) Incoming MCCB capacity 250 amp , 4 pole, 415V, 50 Hz, 36 KA rupturing capacity fixed manual type - 1 No. Note :- (i)Anything missed out above but technically required for efficient working of APFC Panel is deemed to be included in quoted rates. (ii) Design / Drawing of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from Engr-in-charge/GE before placing final order to the manufacturer/Supplier. Make- Larsen &Toubro/ GEC/ Siemens/ ABB/ Epcos | 49.1 | (e) Contactors, 415V, air break type shall be provided for connecting /disconnecting the capacitor banks to the bus bar. (f) The APFC panel provided with two existing terminal and it is connected through GI strip 32 x 6mm size to existing transformer earthing/panel earthing all as specified and directed. (g) Digital panel meter for current,voltage/ frequency and power factor having suitable CT ratio and built in selector switch of size 96mmx96mm,accuracy class-I, shall be provided. (h) All control wires shall be not less than 2.5 sqmm multistranded copper conductor and propeperly bunched/ tied,ferruled for proper identification and crimpled with adequate size of lugs etc complete all as directed. (j) Auto/ Manual switch-01 No. (k) Fuse for line protection as per requirement and as approved (l) Indicator lamp LED based with lamp holder as per requirement and as approved (m) Current transformer (CT) of ratio 400/5 A , measuring class accuracy 0.5 to 1.0 for capacitor panel. (n) Incoming MCCB capacity 250 amp , 4 pole, 415V, 50 Hz, 36 KA rupturing capacity fixed manual type - 1 No. Note :- (i)Anything missed out above but technically required for efficient working of APFC Panel is deemed to be included in quoted rates. (ii) Design / Drawing of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from Engr-in-charge/GE before placing final order to the manufacturer/Supplier. Make- Larsen &Toubro/ GEC/ Siemens/ ABB/ Epcos | |||||||||||||||||||||||||||||||||||||||||||||||||||
50 | Supplying, installing, testing and commissioning in replacement of Bus Bar Panel CPRI approved outdoor type of suitable size with modular compartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with double door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 250 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following :- (For Bus Bar Panel) (a) MCCB 4 pole ,Ics=100%Icu- 25 KA, 415 Volts, 125Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No, Make : Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH) (b) Digital type Ammeter 0 - 100 Amps with CT ratio 100/5 including selector switch - 01 No. (c) Digital type Voltmeter 0 - 500 V with selector switch - 01 No. | 1.00 | EACH | 100.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 50 | Supplying, installing, testing and commissioning in replacement of Bus Bar Panel CPRI approved outdoor type of suitable size with modular compartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with double door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 250 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following :- (For Bus Bar Panel) (a) MCCB 4 pole ,Ics=100%Icu- 25 KA, 415 Volts, 125Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No, Make : Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH) (b) Digital type Ammeter 0 - 100 Amps with CT ratio 100/5 including selector switch - 01 No. (c) Digital type Voltmeter 0 - 500 V with selector switch - 01 No. | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
51 | Supply, install testing & commissioning pedastal cubical type double door LT feedar pillar box factory made modular construction fabricated out of 2 mm thick CRCA sheet angle iron leg 30 cm long , epoxy powder coated to give a superior finish indoor type, totally enclosed dust & vermin proof ( compartment wise) front and back side opening system, overall size of each incoming and outgoing module should not less than 350mm x 350mm x 550mm and busbar chamber should be suitable for accomodating all copper bus bar strips 40mm x 10mm x 04 nos fixed on porceilin insulator and one independent metering module suitable for accomodating three phase volt meter& ammeter digital type, inducator lamps, cable entry/ exit cut outs at bottom or upper parts as mentioned below, complete electrically interconnected with copper strips of suitable size for all incoming and outgoing MCCBs and accessories with fixing arrangements on PCC floor with anchor fastner, nuts, washers etc. Danger board with scull suitable for 415 v of required size and manufacturer name plate and SI no of panel to be fixed on panel and consisting of following accessories including dismantling of old panel all as directed. (a) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-Charge (b) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set (c) Digital type Ammeter 0 - 100 Amps with CT including selector switch - 01 No. (d) Digital type Voltmeter 0 - 500 V with selector switch - 01 No. (e) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (f) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (g) Necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor- 01 Job (h) All incoming/ outgoing feeders to be marked with suitable size of stencils as directed. | 1.00 | EACH | 100.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 51 | Supply, install testing & commissioning pedastal cubical type double door LT feedar pillar box factory made modular construction fabricated out of 2 mm thick CRCA sheet angle iron leg 30 cm long , epoxy powder coated to give a superior finish indoor type, totally enclosed dust & vermin proof ( compartment wise) front and back side opening system, overall size of each incoming and outgoing module should not less than 350mm x 350mm x 550mm and busbar chamber should be suitable for accomodating all copper bus bar strips 40mm x 10mm x 04 nos fixed on porceilin insulator and one independent metering module suitable for accomodating three phase volt meter& ammeter digital type, inducator lamps, cable entry/ exit cut outs at bottom or upper parts as mentioned below, complete electrically interconnected with copper strips of suitable size for all incoming and outgoing MCCBs and accessories with fixing arrangements on PCC floor with anchor fastner, nuts, washers etc. Danger board with scull suitable for 415 v of required size and manufacturer name plate and SI no of panel to be fixed on panel and consisting of following accessories including dismantling of old panel all as directed. (a) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-Charge (b) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set (c) Digital type Ammeter 0 - 100 Amps with CT including selector switch - 01 No. (d) Digital type Voltmeter 0 - 500 V with selector switch - 01 No. (e) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (f) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (g) Necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor- 01 Job (h) All incoming/ outgoing feeders to be marked with suitable size of stencils as directed. | 1 | EACH | |||||||||||||||||||||||||||||||||||||||
51.1 | (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No (b) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos (c) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 40 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos (d) MCB SPN 32 Amps, 240 volts, 10KA 'C' curve- 04 Nos (e) MCB FP 40 Amps, 240 volts, 10KA 'C' curve- 01 No Make of MCCB/MCB: Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH) | 51.1 | (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No (b) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos (c) MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 40 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos (d) MCB SPN 32 Amps, 240 volts, 10KA 'C' curve- 04 Nos (e) MCB FP 40 Amps, 240 volts, 10KA 'C' curve- 01 No Make of MCCB/MCB: Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH) | |||||||||||||||||||||||||||||||||||||||||||||||||||
52 | Note: Deduct Credit for demolished / dismantled material of Rs. (-) 58,205.00 (Minus) as listed in Schedule of Credit. Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' | 52 | Note: Deduct Credit for demolished / dismantled material of Rs. (-) 58,205.00 (Minus) as listed in Schedule of Credit. Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' | |||||||||||||||||||||||||||||||||||||||||||||||||||
Total in Figures | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Figures | Select | 0.0000 | 0.0000 | Zero Only | ||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Words | INR Zero Only |
Andaman & Nicobar Tenders |Andhra Pradesh Tenders |Arunachal Pradesh Tenders |Assam Tenders |Bihar Tenders |Chandigarh Tenders |Chhattisgarh Tenders |Dadra & Nagar Haveli Tenders |Daman & Diu Tenders |Delhi Tenders |Goa Tenders |Gujarat Tenders |Haryana Tenders |Himachal Pradesh Tenders |Jammu & Kashmir Tenders |Jharkhand Tenders |Karnataka Tenders |Kerala Tenders |Ladakh Tenders |Lakshadweep Tenders |Madhya Pradesh Tenders |Maharashtra Tenders |Manipur Tenders |Meghalaya Tenders |Mizoram Tenders |Nagaland Tenders |Odisha Tenders |Pondicherry Tenders |Punjab Tenders |Rajasthan Tenders |Sikkim Tenders |Tamil Nadu Tenders |Telangana Tenders |Tripura Tenders |Uttarakhand Tenders |Uttar Pradesh Tenders |West Bengal Tenders |