Items - CONVERSION OF OH LINE TO UG LT WITH CONNECTED ITEMS AT RAMGARH CANTT UNDER GE RAMGARH
Item Rate BoQ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BoQ_Ver3.0 | Item Rate | Normal | INR Only | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
Select, Excess (+), Less (-) | Less (-) | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Tender Inviting Authority: CWE RANCHI | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Name of Work: CONVERSION OF OH LINE TO UG LT WITH CONNECTED ITEMS AT RAMGARH CANTT UNDER GE RAMGARH | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Contract No : CWE/RAN/RAM/ OF 2025-2026 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bidder Name : | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sl. No | Item Description | Item Code / Make | Quantity | Units | Estimated Rate | Addition / Deduction | Addition / Deduction Values | Currency Convertion against each Item | Quoted Currency in INR / Other Currency | RATE including all taxes Figures To be entered by the Bidder Rs. P | Excise Duty | VAT | Freight Charges ( Unloading & Stacking) | Any Other Taxes/Duties/Levies | Other Taxes 2 | IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax | Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category | TOTAL AMOUNT With Taxes | TOTAL AMOUNT With Taxes | TOTAL AMOUNT In Words | ||||||||||||||||||||||||||||||||||
1 | 2 | 3 | 3 | 4 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 5 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 | 51 | 52 | 6 | 54 | 7 |
1 | Excavation, in trenches n.exc 1.5 m wide & n.exc 1.5 m in depth for laying cable/pipes and getting out in soft/ loose soil, complete all as directed. | 2713.91 | Cum | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
2 | Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick, complete all as directed. | 1239.35 | Cum | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
3 | Removing excavated materials (soil) to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the staring point, complete all as directed. | 1474.56 | Cum | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
4 | M&L for Sub class "B" bricks laid dry width wise across the line of cable in trenches as cable protection complete all as directed. | 76.10 | Per 1000 Nos | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
5 | M & L,for Supplying and laying unreinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as directed. | 31000.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
6 | Supply and laying clean and dry sand free from sharp material (unwashed) in trenches around the cable for cushioning complete all as directed. | 1085.56 | Cum | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
7 | Boring of holes under road, pavement, hard standing by mannual boring complete all as directed. | 250.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
8 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core complete all as directed. | 430.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
9 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as directed. | 350.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
10 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as directed. | 170.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
11 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as directed. | 420.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
12 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as directed. | 375.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
13 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as directed. | 370.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
14 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as directed. | 510.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as directed. | 75.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
16 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as directed. | 650.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
17 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 04 core complete all as directed. | 5247.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
18 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 04 core complete all as directed. | 6055.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
19 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 04 core complete all as directed. | 100.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
20 | Supply and fixing GI Pipe light grade of size 80 mm bore with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories complete for protection of cable complete all as directed. | 60.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
21 | Supply and fixing GI Pipe light grade of size 50 mm dia with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories complete for protection of cable complete all as directed. | 450.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
22 | Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip of size 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to LT panel boards including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40 mm dia bore GI light grade as earth strip protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of size 300x300x50mm as earth pit cover reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing on completion complete all as directed. Note:- Rate quoted deemed to be included excavation and earth work in any type of soil with PCC type C1 in pit Cover & other arrangement complete all as directed. | 44.00 | Each Set | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
23 | Supply & fixing in provision cubical type Cable junction box of size 195 x 135 x 90 mm fabricated out of 2 mm thick CRCA sheet juction box for street light pole mounted terminal box suitable for mounting on round pole and suitable arrangement for fixing bracket complete with one MCB 6 amps capacity single pole and suitable to terminate loop in/out cables complete all as directed. | 149.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
24 | Supply and fixing in provision cable PVC insulated unsheathed of size 2.5 Sqmm 2 core copper conductor for connections from junction box to security light complete all as directed. (for juction box to security light). | 1192.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
25 | Taking down and removing LED street light/security light of any make and wattage and depostied to MES store for keeping in safe custody for reuse and refixing at its original location complete all as directed. | 149.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
26 | Refixing of LED street light/security light of any make and wattage at its original location complete all as directed. | 100.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
27 | Supply and fixing building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65/66 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 35 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as directed. | 49.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
28 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 500 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (Main panel No. 01 at cinema hall) : - (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 to 6 sqmm copper conductor cable single core of required length - 01 Job (iv) Four pole MCCB 160 Amp, 50Hz, 415 Volts with repturing capacity 36KA, adjustable thermal magnetic type - 01 No (as incomer) (v) Four pole MCCB 80 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 02 No (vi) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01No (vii) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10KA - 02 No (viii) Digital timer switch of 28 memory locations, current capacity 16 Amp - 01 No (ix) Contactor for timer switch - 01 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 1.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
29 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 500 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (Main panel No. 02 at 20/4 camp corner) : - (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 to 6 sqmm copper conductor cable single core of required length - 01 Job (iv) Four pole MCCB 250 Amp, 50Hz, 415 Volts with repturing capacity 36KA, adjustable thermal magnetic type - 01 No (as incomer) (v) Four pole MCCB 125 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No Spare (vi) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10KA - 02 No (vii) Digital timer switch of 28 memory locations, current capacity 16 Amp - 01 No (viii) Contactor for timer switch -01 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 1.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
30 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 500 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (Main panel No 03 at front of SPMK) :- (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 to 6 sqmm copper conductor cable single core of required length - 01 Job (iv) Four pole MCCB 250 Amp, 50Hz, 415 Volts with repturing capacity 36KA, adjustable thermal magnetic type - 01 No (as incomer) (iv) Four pole MCCB 100 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 02 No (v) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 04 No (vi) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10KA - 02 No (vii) Digital timer switch of 28 memory locations, current capacity 16 Amp - 01 No (viii) Contactor for timer switch - 01 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 1.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
31 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 200 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (FPB No.P-01,T-01,T-05 ) :- (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 sqmm copper conductor cable single core of required length - 01 Job (iv) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No (As Incomer) (v) Four pole MCCB 50 Amp, 50Hz, 415 Volts with repturing capacity 16 KA, adjustable thermal magnetic type - 06 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 3.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
32 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 200 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (FPB No. P-02,) :- (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 sqmm copper conductor cable single core of required length - 01 Job (iv) Four pole MCCB 80 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No ( As Incomer) (v) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 16 KA, adjustable thermal magnetic type - 06 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 1.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
33 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 200 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (FPB No. H-1,T-3 ) :- (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 sqmm copper conductor cable single core of required length - 01 Job (iv) Four pole MCCB 100 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No (As incomer) (vii) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 16 KA, adjustable thermal magnetic type - 08 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 2.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
34 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 200 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (FPB N0. T-2 &T-4) : - (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (iii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iv) Panel instrumental wiring with FRLSH 4 sqmm copper conductor cable single core of required length - 01 Job (v) Four pole MCCB 100 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No (As Incomer) (vi) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 16KA, adjustable thermal magnetic type - 08 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 2.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
35 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 300 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (FPB No. R-1): - (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 sqmm copper conductor cable single core of required length - 01 Job (iv) Four pole MCCB 160 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No (as incomer) (v) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 16KA, adjustable thermal magnetic type - 10 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 1.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
36 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 300 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (FPB No. R-2): - (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 sqmm copper conductor cable single core of required length - 01 Job (iv) Four pole MCCB 160 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No (as incomer) (v) Four pole MCCB 160 Amp, 50Hz, 415 Volts with repturing capacity 16KA, adjustable thermal magnetic type - 01 No (vi) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 16KA, adjustable thermal magnetic type - 01 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made | 1.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
37 | S&F factory made epoxy powder coated sheet metal enclosures for Distribution Board VTPN DB's 4 ways, 415 volt grade , with metal double door including 200 amp rated copper bus bar with two neutral bar , earth bar & cable ties for cable management fully insulated bus bar with set of wires and door earthing with provision of space for MCCB as incomer and SP/TP MCB as out going four way including strandard DIN rail, for cable management, top and bottom removeable gland plates with knockouts complete all as directed. Make- Indoasian Type Optium F1+12 Cat No -811888 Or its equevalent. | 46.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
38 | S&F MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 kA with enclouser complete all as directed. | 46.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
39 | Dismantling of ACSR conductors from steel/PCC poles, service feeder or distributor span complete all as directed. | 57.25 | Per Qtl | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
40 | Dismantling of stay assembly complete, (demolition of concrete, etc and excavation measured separately) complete all as directed. | 11.00 | Per Set | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
41 | Dismantling of insulators any type, any size from cross-arms of MS Channels or angle sections etc complete all as directed. | 954.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
42 | Dismantling of cross-arms of MS channel or angle sections etc. complete all as directed. | 27.22 | Per Qtl | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
43 | Taking out from trenches/ pole XLPE cable and service wire with aluminium conductor, 1100 volts grade, Any size complete all as directed. | 1225.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
44 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 500 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (Main panel No. 01 ,17 Camp) : - (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 to 6 sqmm copper conductor cable single core of required length - 01 Job (Incommer) (iv) Four pole MCCB 315 Amp, 50Hz, 415 Volts with repturing capacity 50KA, adjustable thermal magnetic type - 01 No (as incomer) (Outgoing) (v) Four pole MCCB 125 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 03 No (vi) Four pole MCCB 100 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 02 No (vii) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 03 No (x) MCB TPN 100 Amp, 50 Hz, 415 V with rupturing capacity 10KA - 02 No (xi) Digital timer switch of 28 memory locations, current capacity 16 Amp - 01 No (xii) Contactor for timer switch - 01 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 1.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
45 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 200 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (FPB No. 01, 02,03 ) :- (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 sqmm copper conductor cable single core of required length - 01 Job (Incommer) (iv) Four pole MCCB 125 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No (Outgoing) (v) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 16 KA, adjustable thermal magnetic type - 05 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 3.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
46 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 200 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (FPB N0. 04 & 06) : - (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 sqmm copper conductor cable single core of required length - 01 Job (Incommer) (iv) Four pole MCCB 100 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No (Outgoing) (v) Four pole MCCB 63 Amp, 50Hz, 415 Volts with repturing capacity 16KA, adjustable thermal magnetic type - 05 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. | 2.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
47 | M&L for installation, commissioning & testing in provision of plinth mounted LT panel board outdoor type factory made CPRI approved, fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, single door, accessible from front side with locking arrangement, 3 phase 4 wire system at AC 440 V, 50 HZ with colour coded copper bus bar of rated current capacity 300 A complete applied with two coats of synthetic enamelled paint over a coat of anti corrosion primer and mounted on angle iron of size 40x40x5 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories (FPB No. 05 and 7): - (i) Digital multifunction meter 0-500 volt, AC 3 Phase - 01 No (ii) Panel indicating lamp LED type (Red ,Yellow & Blue) with holder and fuse holder 230/240 Volts, AC - 01 Set (Set of three) (iii) Panel instrumental wiring with FRLSH 4 sqmm copper conductor cable single core of required length - 01 Job (Incommer) (iv) Four pole MCCB 100 Amp, 50Hz, 415 Volts with repturing capacity 25KA, adjustable thermal magnetic type - 01 No (as incomer) (Outgoing) (vii) Four pole MCCB 50 Amp, 50Hz, 415 Volts with repturing capacity 16KA, adjustable thermal magnetic type - 04 No Note : (a) The height of panel should be 0.60 mtr from ground level with PCC foundation. (b) Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made | 2.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
Total in Figures | 0.00 | 0.00 | INR Zero Only | 4 | Construction of chamber for 100mm sluice plates | item5 | 10 | Nos | ||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Figures | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 | Select | 0.0000 | 0.0000 | Zero Only | |||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Words | INR Zero Only |
Andaman & Nicobar Tenders |Andhra Pradesh Tenders |Arunachal Pradesh Tenders |Assam Tenders |Bihar Tenders |Chandigarh Tenders |Chhattisgarh Tenders |Dadra & Nagar Haveli Tenders |Daman & Diu Tenders |Delhi Tenders |Goa Tenders |Gujarat Tenders |Haryana Tenders |Himachal Pradesh Tenders |Jammu & Kashmir Tenders |Jharkhand Tenders |Karnataka Tenders |Kerala Tenders |Ladakh Tenders |Lakshadweep Tenders |Madhya Pradesh Tenders |Maharashtra Tenders |Manipur Tenders |Meghalaya Tenders |Mizoram Tenders |Nagaland Tenders |Odisha Tenders |Pondicherry Tenders |Punjab Tenders |Rajasthan Tenders |Sikkim Tenders |Tamil Nadu Tenders |Telangana Tenders |Tripura Tenders |Uttarakhand Tenders |Uttar Pradesh Tenders |West Bengal Tenders |