Bidhelp
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CESC AND CE( NAVY )MUMBAI - MES||CWE (SUBURB) MUMBAI - MES
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CESC AND CE( NAVY )MUMBAI - MES||CWE (SUBURB) MUMBAI - MES
CWE (SUBS) MUMBAI
Gujarat QTY :

Items - MAINTENANCE/ REPAIR/ REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY INSTALLATIONS, TRANFORMERS, TWO/ FOUR POLE STRUCTURES, VCBS, HT PANELS, HT/LT CABLE AND HT GOD SWITCHES INCLUDING PREVENTIVE MAINTENNACE AND ALLIED WORKS AT NAVAL BASE PORBANDAR UNDER GE (

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver3.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority: CWE (SUBS) MUMBAI
Name of Work: MAINTENANACE /REPAIR/REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY INSTALLATION ,TRANSFORMER, TWO/FOUR POLE STRUCTURE, VCB, HT PANEL,HT/LT CABLE & HT GOD SWITCHES INCLUDING PREVENTIVE MAINTENANCE AND ALLLIED WORKS AT NAVAL BASE PORBANDAR UNDER GE (NAVY ) PORBANDAR
Contract No: 8918/ 08 /E8
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Sl. No.Item Description and Drg No.Item Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyRATE In Figures To be entered by the Bidder Rs. P Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With TaxesTOTAL AMOUNT In Words
12334578910111251415161718192021222324252627282930313233343536373839404142434445464748495051526547
1.00M & L for general maintainance of 11 KV VCB's of different capacities and comprising the following: Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800/1000 Amps from location and repair /overhauling and carrying out with the following and all as specified and directed by Engineer-in-Charge. (Note: spare parts will be measured & paid seperately.) (a) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly switch assembly and apply multi grease lubricant to function smoothly. (b) Inspecting / overhauling of earthfault release assembly, tripping coil, auxilary switch etc and checking of electrical wiring system. (c) Calebration & Testing of over current & Earth fault relay by primary & secondary ejection methods. (d) Insulating of VCB track, greasing of wheel and checking for few movement for closing and withdrawing of VCB track. Inspecting / overhauling /cleaning power pack unit/battery bank such that in normal condition,VCB Control Circuit shall be operated by 110 V DC (e) Cleaning/wiping the insulating components, primary & secondary circuits i.e green spots, carbon deposited completely. Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interupters by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (f) Testing of primary & secondary circuit with 1000 Volts megger for insulation resistance. (g) Flash testing of secondary circuit at 2000Volts for one minute after disconnecting the instruments from the panel. Assembling all items/components parts to the respective postion after high voltage test complete. (h) Testing, sychronisation / calibration of meters and relays. (i) Cleaning/wiping of busbar, phase barriers, Busbar support and sleeves. (j) Scraping & painting the VCB with approved quality of grey paint all as directed by Engineer-in- Charge.16.00JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
2.00Dehydration of tranformer oil, obtained from transformers/voltage stabilizer etc. Dielctric strength shall not be less than 60 KV in 2.5 mm gap electrode after dehydration. Dehydration of transformer shall be carried out by using electrically operated dehydration machine including replacement of unserviceable silica gel and toping up/ replacement of unserviceable transformer oil complete all as directed. (NOTE :-- 1) Silica gel & new tranformer oil for top up shall be measured and paid against respective item. 2) Filteration of transformer oil shall be off loaded position of transformer. 3200.00LtrExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
3.00Supply and filling transformer oil of approved quality ISI marked for filling in transformer for topping up/ replacement complete all as directed by Engr-In-Charge. Make: power/castrol/servo/asian/savita/electric. Note:-(i) Dielectric strength of transformer oil not less than 60 KV with 2.5mm gap. (ii) New oil which is to be supplied for filling should be in a sealed barrel/container only.550.00LtrExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
4.00Supply and fixing in repair of breather with 500 Grams silica gel for transformer upto 400 KVA, all as specified and directed by Engineer-in-Charge.8.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
5.00Taking of old silica Gel for dehydrating Breather of transformer, cleaning the breather internally and externally and filling new silica gel blue colour in dehydrating breather. 6.00KgsExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
6.00M & L for spray painting of transformers (any type power or distribution)) of capacity upto and including 100 to 630 kVA ( in situ ) outdoor/indoor type, installed and located at different sites in scattered area under the GE including the following: - (a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete. (b) Spray painting with two coats of synthetic enamel paint of approved make / quality all as directed at site. (c) Writing the SM MES No of transformer on MS body of transformer all as directed .17.00JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
7.00Supply and fix in repair/replacement industrial type temperature gauge of range 0⁰ to 200⁰C for indication of temperature rise in transformer oil for transformers upto 630 kVA capacity including taking out old unsv complete all as specified..5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
8.00Material and Labour for disconnection of both HT and LT connection from cable and box, taking down the disconnected transformer (Outdoor/indoor type) upto 630 KVA capacity 11/.433 KV, installed at different substation and transporation of unserviceable transformer complete unit to the Transformer repairing workshop and reinstallation the same after repaired back including arrangement of necessary T & P crane and vehicle etc for loading/unloading and to carry following work (i) Draining out transformer oil, taking down HT/LT studs and opening the top cover to checking of windings. (ii) Desludging of core and coil assembly by hot oil pressure and checking/testing of all accessories to identify fault leve. (iii) Brazing of burnt/disconnected copper wound surfaces, studs and connectors including replacement of unserviceable bolts, refixing of existing serviceable bolts, nuts, washers of different size and tightening properly. (iv) Replacement of all gasket materials in top cover , HT, LT bushing using rubberized gasket sheet 4.0/6.0 mm thick duly paster with gasket cement including replacement of LT/HT coils. (v) Repositioning of core and winding assembly inside the tank, assembling the complete unit and re-filling of old transformer oil and top up with new transformer oil including oil filtration and testing. (vi) After assembly of complete unit of transformer load testing, insulation testing including all testing shall be carried out as per IEC and IS and test certificate shall be submitted complete all as specified and directed by Engineer-in-Charge. Note : Transformer oil and copper windings if required shall be measured and paid separately under relevant items of the schedule.2.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
9.00Supply only LT leg coil of copper windings with EC grade for transformer of capacity up to 630 KVA complete with insulation, varnishing by vacuum impregnation and baking of coil assembly, etc. complete all as specified & directed by the Engineer-in-Charge.150.00PER KGExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
10.00 Supply only HT leg coil of copper windings with EC grade for transformer of capacity up to 630 KVA complete with insulation, varnishing by vacuum impregnation and baking of coil assembly, etc. complete all as specified & directed by the Engineer-in-Charge.250.00PER KGExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
11.00Material and labour for disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for attending leakage problem with replacement of oil seal, all gaskets, thermometer(oil temperature gauge) and reassembling complete all as directed.(Note : New Transformer oil and spare parts will be measured and paid separately)3Supplying, Conveying and fixing spls. Including eaitem410Nos
11.01Transformer upto 630 KVA ,11KV/440Volt 5.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
12.00Supply only for replacement of burnt out studs and bushing with nuts of any material by providing new brass alloy stud with nut,washers and bushing with oil seals on HT side all as directed for following capacity transformers:-3Supplying, Conveying and fixing spls. Including eaitem410Nos
12.01Transformer upto 630 KVA ,11KV/440Volt (set of three)5.00Each SetExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
13.00Supply only for replacement of burnt out studs and bushing with nuts of any material by providing new brass alloy stud with nut,washers and bushing with oil seals on LT side all as directed for following capacity transformers:-1.02Construction of chamber for 100mm sluice platesitem2213Nos
13.01Transformer upto 630 KVA ,11KV/440Volt (set of four)5.00Each SetExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
14.00M & L for cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor of cable size 95 sqmm complete all as specified.5.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
15.00M & L for cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor of cable size 95 sqmm complete all as specified.5.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
16.00M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of of cable size 95 sqmm complete all as specified.12.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
17.00S& f in replacement of Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, rocking tilting type consisting of MS channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod of GI pipe medium grade confirming to IS-1818 of 1972 ,suitable for 11000 volt ,400 Amps all as specified.2.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
18.00S& f in replacement of Lightning arrester non linear type complete with all fittings distribution class discharge capacity 65 kilo amp, current rating 5 kA suitable for 11000 volt complete with all fittings including taking down old3.00Set of 3 Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
19.00S& f in replacement of drop out fuse assembly for 11 KV, 3 Phase of 100 Amp capacity each pole, consisting of galvanized steel base paper fuse carrying brackets, mounting channel, separating rod complete all as specified as directed by Engr-in-Charge.6.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
20.00Dismantling of U/S existing cross arms by means made from channels, angles, U/S FI clamps, nuts, bolts etc. from OH line and removing complete.2.00Per QtlExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
21.00Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide .2.00Per QtlExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
22.00Supply and erect in replacement of steel tubular swaged poles complete with cast iron base plate, nuts and taper plug , bolts, nuts and screws as specified type HT pole type 410-SP-55 (11mtr long) inclunding foundation and coping of pole as per manufacturer specifications complete all as specified and as directed.4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
23.00M & L for painting of two pole strucure including of 11 mtr HT electric steel tubular pole with all connected channel, cross arms caps etc painting one coat of aluminium paint over a coat of anti rusted paint as a primer on steel surfaces and One coat of primer and two coat of exterior acrylic emulsion paint (wheather coat) on Concrete surfaces and silver colour on steel surface including numbering by using white paint over a surface of black paint base of size 15cm x 15cm complete all as specified and as directed by Engineer-in-Charge.15.00Each jobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
24.00Taking up of under ground HT Cable of any size along with protection cover/ bricks and removing from site all as directed by Engr-in-Charge.300.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
25.00Supply, laying and fix in Repair/ Replacement of LT Cable laid in trenches, passing through pipes and fixed on wall/floor/ceiling with proper saddles , including testing of XLPE insulated screned PVC beded galvanised steel strip or wire armoured earthed electric power cable (heavy duty) with aluminium couductor 11/6.35 KV grade suitable for earthed system cross sectional area 95 sqmm 3 core H.T.U.G cable laid in tranches/through GI pipe/fixed along with pole complete all as specified & directed Note -Excavation and earth work shall be measured and paid for separately under relevant item of schedule.300.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
26.00Taking down unservisable U/G LT cable from trenches, wall, floor etc single/multicore any type,size all as directed by Engr-in-Charge.745.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
27.00Supply, laying and fix in Repair/ Replacement of LT Cable laid in trenches, passing through pipes and fixed on wall/floor/ceiling with proper saddles , including testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size 16 sq mm 4 core. Note- rate is inclusive of cable gland & cable lugs Note -Excavation and earth work shall be measured and paid for separately under relevant item of schedule.225.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
27.01All as per item No.27 above but of size 35 sq mm X 3.5 core150.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
27.02All as per item No. 27 above but of size 50 sq mm X 3.5 core120.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
27.03All as per item No.27 above but of size 70 sq mm X 3.5 core130.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
27.04All as per item No.27 above but of size 95 sq mm X 3.5 core120.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
27.05All as per item No.27 above but of size 120 sq mm X 3.5 core100.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
27.06All as per item No.27 above but of size 240 sq mm X 3.5 core80.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
28.00 M & L for Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth getting out for the pole foundation/cable all as directed in Hard/dense soil complete all as specified and directed. 304.70CUMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
29.00All as per item no 28 above but depth exceeding 1.5 mtr and not exceeding 3.00 mtr deep and getting out.0.65CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
30.00M & L for Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm in thick all as specified and directed. 302.10CUMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
31.00 M & L for Removing excavated material to a distance not exc 50 mtr and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified by the Engineer-in-charge. 3.24CUMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
32.00S& F in replacement of laying of Double Walled Corrugated (DWC) HDPE pipe of following size of conforming to IS 16205 Part -24 including necessary bends,coupling ,tees, reducers, spacers,end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge Make:-ASTRAL TELEREX /eqivalent as approved by GE1.02Construction of chamber for 100mm sluice platesitem2213Nos
32.01 40/32 mm outer/inner dia225.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
32.02 50/38 mm outer/inner dia150.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
32.03 63/50 mm outer/inner dia120.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
32.04 75/63 mm outer/inner dia130.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
32.05 90/75 mm outer/inner dia270.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
33.00GI Tubing light grade 80mm for cable protection, laid under plinths/floors /roads /culverts or fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I clamps with necessary bolts nuts washers etc complete all as specified. 60.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
34.00Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade all as specified and directed by Engr-in-Charge. 6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
35.00S & F HT disc insulator porcelain vitreous 145mm height, 255mm dia, ball and socket type. White / brown with M.S. galvanized iron fitting suitable for working pressure 11KV all as specified and directed by Engr-in-Charge.6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
36.00SUPPLY & FIX PVC junction box of size inside dimenssion 250x200x100 mm complete with industrial connector, including clamp made out of MS flat iron 30x5 mm , nut, bolts, washer ,glands etc , MCB 6-10Amps complete all as specified & directed Make:Sintex cat no : GS JB 252025.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
37.00Material and labour for Phase barrier with spacers of 11KV VCB including taking down old unserviceable or burnt Phase barrier. Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
38.00Material and labour for test / service limit switch of 11KV VCB including taking down old unserviceable or burnt Support rod with allen bolt. Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
39.00Material and labour for TNC switch of 11KV VCB including taking down old unserviceable or burnt TNC switch Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
40.00Material and labour for Closing coil assembly of 11KV VCB including taking down old unserviceable or burnt Closing coil assembly Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
41.00Material and labour for Tripping coil assembly of 11KV VCB including taking down old unserviceable or burnt Tripping coil assembly Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
42.00Material and labour for Motor gear assembly UMG of 11KV VCB including taking down old unserviceable or burnt Motor gear assembly UMG Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
43.00Material and labour for Big and small gear assembly of 11KV VCB including taking down old unserviceable or burnt Big and small gear assembly Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
44.00Material and labour for cut of motor limit switch of 11KV VCB including taking down old unserviceable or burnt cut of motor limit switch Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
45.00Material and labour for Auxiliary switch of 11KV VCB including taking down old unserviceable or burnt Auxiliary switch Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
46.00Material and labour for Tripping Shaft with spring and trip strips of 11KV VCB including taking down old unserviceable or burnt Tripping Shaft with spring and trip strips Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
47.00Material and labour for closing Shaft with spring and trip strips of 11KV VCB including taking down old unserviceable or burnt closing Shaft with spring and trip strips Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
48.00Material and labour for Bridge rectifier of 11KV VCB including taking down old unserviceable or burnt Bridge rectifier Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
49.00Material and labour for Fixing and testing of Vaccum intrupter o f 11KV VCB including taking down old unserviceable or burnt Vaccum intrupter Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing.5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
50.00Supply and fix in replacement Relay Nuemerical IDMTL+Inst O/C & E/F, Type N141 (Art.No.1MYN742838D) 30V DC,CTR 5A. Make: Asida/C&S/L&T/Eassun Reyrole/Schnieder/CG/ABB/ GEC/ EE/ Seimens6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
51.00Material and labour for Fixing and testing of Spout bushing o f 11KV VCB including taking down old unserviceable or Spout bushing Of feeder panel. all as per directed by Engr In Charge (set of six) .Maker - Crompton greaves power or as per the sample of existing.1.00Each setExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
52.00Material and labour for Fixing and testing of Current transformer resin cast ratio 100-50/5-5A. o f 11KV VCB including taking down old unserviceable or Current transformer resin Of feeder panel. all as per directed by Engr In Charge.Make - Crompton greaves power or as per the sample of existing.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
53.00Material and labour for fixing and testing Potential Transformer, Resin cast dry type 11KV/ 110Volt /Rout3,100VA burden, Class 1 Accuracy, Trolly mounted.Make - Crompton greaves power or as per the sample of existing.3.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
54.00Supply only Multi Function meters in existing HT/LT Panel Board Digital type 96x96mm, Aux Supply 230Volts AC,Type: EM6436 Conzerv(Schneider Electric) or Equvallant AE/SECURE complete all as specified and directed by Engineer-in-Charge. ( Note : cost of labour deemed to be included in item No. 1)4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
55.00Supply and fixing of 11 KV VCB electric panel heater , voltage 230 V all as specified and directed by Engr-in - charge.4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
56.00Supply only gasket for VCB panel door all as specified and directed by Engr-in-Charge. ( Note : cost of labour deemed to be included in item No. 1)30.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
57.00Supply only Ammeter selector switch for 11 KV VCB all as specified and directed by Engr-in- charge. ( Note : cost of labour deemed to be included in item No. 1)3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
58.00Supply only Voltmeter selector switch for 11 KV VCB all as specified and directed by Engr-in- charge. ( Note : cost of labour deemed to be included in item No. 1)3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
59.00Supply only LED Indicator lamp suitable for 11 KV vcb with complete colour coding . All as specified and directed by Engr -in-charge. ( Note : cost of labour deemed to be included in item No. 1)12.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
60.00Supply and spread and leveling Graded coarse Aggregate in loose filling over the surface of gauge 40/20 mm nominal size in the installation yard including removal of unwanted plants, grass, bushes around installation. all as specified and as directed by Engr-in-charge.50.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
61.00M&L for jet Ecosafe maintenance free and Environment Friendly Earth Electrode set comprising of 17.2mm dia 3 mtrs long rod of Low carbon steel, molecular Copper Bonded for a thickness of 250 microns, highly conductive ANSI NSF STD 60 Certified with 1 Bags (50P) of environment friendly carbon based backfill compound, accordingly to BS 7430 & IEE 80 and with suitable Clamp in 100mm dia bore hole complete all as specified and directed by Engineer-in-Charge.10.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
62.00Earthing continuity galvanised iron strip 32 x 6 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge. 100.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
63.00Material and labour for HT fault locating of any size cable by Surge generating HT fault locating machine of suitable capacity from Authorised fault locating agancy including connecting earthing to machine, excavation , pcc cutting if required all as directed by Engineer-In-Charge. Note : 1. Fault location to be done within 5 hr after giving instruction by Engr-in-charge. 2. All necessar arrangement for machine is deemed to be included in quoted rate15.00Each jobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
64.00Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT , 25 x 20 cm size75.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
65.00Supply & fix in replacement electrical Insulating mat confirming to IS15652/2006 (superceding IS: 5424-1969) B.I.S+CPRI+NTH+ERDA approved of C class of mats dielectric strength 65KV, sheet thickness not less than 3.0MM using at power houses including pasting of rubber mats with adhesive resin all as specified and directed by Engineer-in-Charge. Make : Swastic /Jyoti80.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
66.00Material and labour for LT fault locating of any size cable by Surge generating fault locating machine of suitable capacity from Authorised fault locating agancy including connecting earthing to machine, excavation , pcc cutting if required all as directed by Engineer-In-Charge. Note : 1. Fault location to be done within 5 hr after giving instruction by Engr-in-charge. 2. All necessar arrangement for machine is deemed to be included in quoted rate12.00Each jobExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
67.00Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size up to 50 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/RAYCHEM/CAMPAQ 12.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
68.00Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 70 to 120 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/RAYCHEM/CAMPAQ 4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
69.00Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 150 to 400 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/RAYCHEM/CAMPAQ 6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
70.00Material & Labour for repairs/ Overhauling /Servicing to Existing LT electric panels Indoor type of each Transformer by taking shut down from appropiate authority including checking loose connections and tight connection and cleaning inside/out side all connection, replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as directd and specified. Note :- The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/Voltmeter/ Ammeter/CT/LED lamps of any type and discription etc and refixing the same after repair/replacement of the item. (i) Cleaning inside the panel and all incoming and out going feeders i.e including MCCB/SFU/Changeover switches/Contactors/ ACB's thorouly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers (iii) Replacing the burnt out color coated PVC Sleeve of main and fedders bus bar with appropriated size of New PVC heat shrinkable sleeves -01Job (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job (v) Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT'swith 2.5/1.5Sqmm copper single core,1100V grade copper conductor cable- 01Job (vi) Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size of new bus bar (Copper/Aluminum) -01Job (vii) Replacing Burnt out Insulators of incomming and out going feeders with approprieted size of new Insulators -01Job (viii) Spray Painting of Panel Board with one coat of synthetic enamel paint. 12.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
71.00M&L for mild steel chequered plate 5 mm thick including cutting fabricated cold or hot welding at site drilling holes nuts - bolt and washers etc including angle iron 25 mm x 25 mm x 3 mm thick for mounting of MS sheet cover dully painted with black bituminous paint over one coat of red oxide primer and as directed. including breaking of existing duct for grouting of angle iron, and making good PCC of the existing duct at water supply installation complete all as specified and directed.250.00KgsExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
72.00M&L for Rectangular RCC Route marker for HT and LT line, Board Thickness: 3 inch Reinforced Concrete Cement Route Marker, colour red of the height upto 3 feet above the ground made of PCC 1:2:4 type B1 including excavation and PCC 1:3:6 Fillling in the trench of size 0.45x0.3 sqm and removing extra material from site all as specified and as directed. 72.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
73.00M&L for cleaning away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees up to 50 cm girth from the area surrounding of E/M installations, under HT&LT over head lines, 4/2 pole structures, transforemer, installations, yards, surrounding valve chamers and removing the rubbish upto a distance 50 mtr outside the periphery of the area under clearance and dressing the area etc complete all as specified and directed by Engr-in-charge.250.00Sqm Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
Total in Figures0.000.00INR Zero Only4Construction of chamber for 100mm sluice platesitem510Nos
Quoted Rate in FiguresSelect0.00000.0000 Zero Only
Quoted Rate in WordsINR Zero Only