Bidhelp
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CESC AND CE (AF) BANGALORE - MES||CWE (AF) (SOUTH) BANGALORE - MES||GE (Maint) (AF) Jalahalli - MES
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CESC AND CE (AF) BANGALORE - MES||CWE (AF) (SOUTH) BANGALORE - MES||GE (Maint) (AF) Jalahalli - MES
Garrison Engineer M AF Jalahalli
Karnataka QTY :

Items - CERTAIN REPAIR MAINT TO FIRE FIGHTING FIRE ALARM SYSTEM CONNECTED ITEMS ELECTRICAL INFRASTRUCTURE POWER FACTOR CORRECTION EARTHING AND CERTAIN MISC E M WORKS AT CQAE WE AND AFS EAST WEST JALAHALLI

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver3.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority: GE (M) AF JALAHALLI BANGALORE
NAME OF WORK: CERTAIN REPAIR/ MAINT TO FIRE FIGHTING/ FIRE ALARM SYSTEM, CONNECTED ITEMS, ELECTRICAL INFRASTRUCTURE, POWER FACTOR CORRECTION, EARTHING AND CERTAIN MISC E/M WORKS AT CQAE (WE) AND AFS EAST WEST JALAHALLI
Contract No: GE(M)AF/JAL/ of 2024-2025
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Conversion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Rs. P Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without TaxesTOTAL AMOUNT With TaxesTOTAL AMOUNT In Words
12334678910111251415161718192021222324252627282930313233343536373839404142434445464748495051525367
1.00Servicing/ comprehensive maintenance of fire alarm system comprising of Smoke detection control panel , Smoke detector (Photoelectric detection Technology), Conventional Fire Alarm control panel, flame detector, conventional manual call point with EN 54-11 : 2001 and LPCB, conventional sounder etc by attending fault testing of system, quarterly checking of system including preventive maintenance by replacing small spare parts complete all as specified and directed. Location : P-96, P-637, P398, T-97, T-243, P-1079, T-247, E&ITI-02 Nos, ETI-03 Nos, 16 TS -04 Nos and Stn HQ (Total locations - 11 Nos)3.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
2.00Note for item No 1 :- (a) The repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer and following checks shall be performed :-2Construction of chamber for 100mm sluices valveitem310Nos
3.00(b) The rate quoted shall be deemed to include for carrying out all repairs noticed during the servicing.3Supplying, Conveying and fixing spls. Including eaitem410Nos
4.00(c) Checking of Alarm signal should not lost when primary power failure untill the alarm signal processed.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
5.00(d) Checking of smoke detector sensibility.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
6.00(e) Checking of all speaker circuit and loops.2Construction of chamber for 100mm sluices valveitem310Nos
7.00(f) Cleaning of smoke detector as per OEM recommendation.2Construction of chamber for 100mm sluices valveitem310Nos
8.00(g) Periodicity shall be overall 3 months or as per manufacturers recommendation.3Supplying, Conveying and fixing spls. Including eaitem410Nos
9.00(h) The major items like smoke & heat detector, addessable sounder & manual call point shall be measured and paid as supply only under respective item of BOQ.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
10.00Supply only heat detectors, photoelectric / optical type certified to EN 54 addressable with self built intelligent with connected accessories complying with optical chamber, cover, case molding, photodiode (transducer), infrared LED all as specified and directed. NOTE:- i). Metal junction box of suitable size for detector made of 16 SWG sheet steel is to be provided for mounting of detectors in the concrete mother ceiling / surface along with necessary gland and boxes duly painted with two coats of super enamelled paint over a coat of red oxide primer. ii) Rate of metal boxes shall be included in quoted rate of items. Make :- Honeywell/Ceasefire /GST/Universal (Ravel)35.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
11.00Supply only Addressable electronic sounder cum strobe. Make :- Honeywell/Ceasefire /GST/Universal (Ravel)5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
12.00Supply only Addressable manual call point resettable type. Make :- Honeywell/Ceasefire /GST/Universal (Ravel)12.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
13.00Supply & install in replacement Fire Alarm Sounders / Sirens Electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 500 mtrs range. Make :- Honeywell/Ceasefire /GST/Universal (Ravel)8.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
14.00Supply & install 2 core solid conductor of size 1.5 sqmm, as per IS-1554 PVC insulated & PVC sheathed, armoured cable FRLS down through non metallic PVC conduit of suitable size shall be properly clamped to the ceiling / surfaces including taking down of unserviceable cable and 'S' loop shall also be left where cables connect to sounders, panels and all the cables and wires shall be tagged for proper identification complete all as specified and directed.450.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
15.00Supply and installation, programming and testing of fire PLC control panel complying with BS EN 54 1 loop panel with 242 detector & 99 module DXc1 Single loop Fire Alarm Control Panel two loop card inbuilt minimum 200 addressable points detectors/ devices per Loop 6*40 character blue crystal display with backlight circuits PT requires including taking down of old one complete all as specified and as directed. Make : Make :- Honeywell/Ceasefire /GST/Universal (Ravel)1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
16.00Supply & install in replacement Addressable control module. Make :- Honeywell/Ceasefire /GST/Universal (Ravel)3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
17.00Supply & install in replacement repeater panel active type . Make :- Honeywell/Ceasefire /GST/Universal (Ravel)1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
18.00Supply & install in replacement Network card suitable for PLC fire control panel 2/4 Loop complete all as specified and as directed. Make :- Honeywell/Ceasefire /GST/Universal (Ravel)1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
19.00Supply & install in replacement Network card suitable for repeater fire panel complete all as specified and as directed. Make :- Honeywell/Ceasefire /GST/Universal (Ravel)1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
20.00Supply and installation ,programming and testing of fire control panel complying with BS EN 54 2 Zone panel with max 20 detector per Zone Fire Alarm Control Panel 16X2 character blue crystal display including taking down of old one and complete all as specified and directed.Make : Honeywell/Ceasefire/Visionic/Universal(Ravel)2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
21.00Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V, upto 7 AH, suitable for fire panel including initial charging complete etc including taking down of old battery complete all as specified and directed. Make of battery : Exide / Amar raja / Amaron Note :- (i) The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation. (ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Chare throughout the currency of contract.12.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
22.00Attending complaints for malfunctioning of fire panel /repeater panel etc of any type/size fitted on bldg at different locations of AFS Jalahalli by deploying technically qualified and experienced technicians to find out defects and suppress the fault 25.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
23.00Note : The following items are deemed to be inclusive of quoted rate :-1.02Construction of chamber for 100mm sluice platesitem2213Nos
24.00The above job shall be carried out by a trained engineer as and when called telephonically /SMS by Engr-in-Charge .2Construction of chamber for 100mm sluices valveitem310Nos
25.00Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of fire panel during day/night. Contractor has to depute Engineer/ technician and all necessary T&P and Equipment's to rectify the breakdown. Complaint of Fault will be intimated through Telephone/ SMS.2Construction of chamber for 100mm sluices valveitem310Nos
26.00The major items like smoke & heat detector, addressable sounder & manual call point shall be measured and paid under respective item of BOQ.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
27.00All type of T & P, Safety Belt, Vehicle, Aluminium Ladder, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department. 1.02Construction of chamber for 100mm sluice platesitem2213Nos
28.00All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the tradesmen deployed for providing the services and department will have no liability for any type of accident. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this account.2Construction of chamber for 100mm sluices valveitem310Nos
29.00In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. 2Construction of chamber for 100mm sluices valveitem310Nos
30.00In case services affected due to delay in attending the complaint, a penalty of Rs 1000 per day will be levied from the contractor.1.02Construction of chamber for 100mm sluice platesitem2213Nos
31.00Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
32.00Comprehensive maintenance of firefighting system comprising of Main pump of capacity not less than 60 HP, Jockey pump not less than 12.5 HP, Diesel driven pump not less than 68 HP and (Roof Top) centrifugal pump 7.5 HP of M/s Kirloskar brothers co Ltd for fire hydrants , controlled by auto control panel ,control valves & pressure gauges for automatic operation of fire pumps and fire hydrants, etc. periodical maintenance as recommended by the original manufacturer including replacement of minor spares complete all as specified and directed. Location : SMC Jalahalli Note :- (a) (i) The contractor shall make AMC contract with the original manufacturer or authorised reputed service provider of firefighting systems. (ii) The repairs/maintenance shall be carried out through the original manufacturers or authorised reputed service provider of fire fighting system only. (b) Checking oil level in diesel engine if necessary filling upto mark level and leakage in system inform to concerned accordingly for necessary action. (c) Tightening of all nut and bolts. (d) Checking of all electrical connections for the in proper tightness incl checking of charging alternator and battery clamps. (e) Supply and greasing in all grease points. (f) Checking all fire hydrants if found leaking of water to arrest the leakages. (g) Checking all pumps glands and if required to replace the gland packing rope. (h) Check all motors and touch if overheating to inform to concerned. (i) Test run of complete system is to be carried out once in a month in presence of MES & Air Force reps. (j) Check all pump pressure and maintain required pressure. (k) Contractor is responsible to ensure required water pressure in the system always as directed by the Engineer-in-Charge.3Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
33.00M&L Taking down defective centrifugal pump set 60 HP capacity by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at same location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
34.00Supply only Ball bearing suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
35.00Supply only split casing gaskets suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
36.00Supply only coupling bolt with nuts suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed. 2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
37.00Supply only coupling Rubber Bush suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
38.00Supply only shaft sleeves suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
39.00Supply only water seal suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed. 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
40.00Supply only Air cock grease nipple suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
41.00Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed. 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
42.00Supply only bronze impeller suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed. 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
43.00M&L for rewinding of squirrel cage induction electrical motor, 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 60 HP motor capacity.1Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
44.00Supply and replacing power contactor 3 pole of suitable for 60 HP motor starter panel board , with NO and NC complete all as specified and directed. Make : ABB/Schneider/Siemens/L&T1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
45.00Supply only in replacement adjustable CT/Direct operated thermal over load relay suitable for 60 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schneider2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
46.00Supply and fix in repair of GI pipe Heavy grade, jointing complete of 150 mm dia with necessary supports and specials such as tees, bends, reducers etc including consumables and painting with one coat of red oxide primer and two coat of synthetic enamel paint including making good the disturbed surfaces of wall/ ceiling etc complete all as directed.6.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
47.00Supply and fixing in replacement butterfly valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed2.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
48.00Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 150 mm ISI marked, CI body complete all specified and directed1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
49.00Supply and fix in repair of GI pipe Heavy grade, jointing complete of 100 mm dia with necessary supports and specials such as tees, bends, reducers etc including consumables and painting with one coat of red oxide primer and two coat of synthetic enamel paint including making good the disturbed surfaces of wall/ ceiling etc complete all as directed.12.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
50.00Supply and fixing in replacement butterfly valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed2.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
51.00M& L for preparation to external old steel surface of pipe of various size and completely removal of existing paint by scraping or chemical and surface painted with synthetic enamal paint with help of brush complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Colour of paint as decided by Engr-in-Charge. (ii) Scafolding and other safety precution shall be provided by the contractor.45.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
52.00M & L as in repair for hose box of any description and providing new hose box made of MS sheet with double door with 4mm thick glass and door frame made of MS sheet duly painted with synthetic enamel paint of red colour outside and inside box complete all as specified and directed. 2.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
53.00Supply and fix as in repair of 2mm thick transparent Arcilary sheet for Hose reel Drum and hose box complete all as specified and directed.5.00SqftExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
54.00Single hydrant stand post made of GI pipe of size 80 mm bore heavy grade, 1.50 m height with 90°, duck foot bend both end flanged and including welding if required to suit single fire hydrant valve and testing complete including taking down existing one complete all as specified and directed .2.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
55.00Supply and fix as in repair SS hydrant valve 63 mm single headed type complete all as specified and directed.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
56.00Supply and fix as in repair fire hose of 7.5 m length 63 mm dia SS with RRL hose clamp with instantneous coupling one complete all as specified and directed. 14.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
57.00Supply and fix as in repair fire hose of 15 m length 63 mm dia SS with RRL hose clamp with instantneous coupling complete all as specified and directed. 2.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
58.00Supply and fix first aid hose reel Drum full swing of 30 m long of dia 19 mm dia including taking down of old unserviceable one complete all as specified and directed. 4.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
59.00Supply and fix as in repair short branch pipe one side 63 mm and other side 15 mm dia with nozzle complete all as specified and directed. 2.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
60.00Supply and fix as in repair blank cap pvc type suitable for 63 mm dia complete all as specified and directed.13.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
61.00Supply and fix as in repair LIP washer suitable for hydrant valve complete all as specified and directed.5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
62.00Supply and fix as in repair SS female coupling 63 mm dia complete all as specified and directed.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
63.00Supply and fix Gun metal hydrant valve 63 mm double headed type including taking down of old unserviceable one complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
64.00Supply only Hose box key complete all as specified and directed.12.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
65.00M& L for preparation to external old steel surface of hose box/door/panel board of various size for fire fighting system and completely removal of existing paint by scraping or chemical and surface painted with synthetic enamal paint with help of brush complete all as specified and as directed Note :- (i) Coloured of paint decided by Engr-in-Charge. 85.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
66.00Taking down defective Jockey/Terrace pump set 7.5 HP to 12.5 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.1Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
67.00Supply only Ball bearing suitable for 7.5 HP to 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
68.00Supply only split casing gaskets suitable for 7.5 HP to 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
69.00Supply only Air cock grease nipple suitable for 7.5 HP to 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
70.00Supply only coupling bolt with nuts suitable for 7.5 HP to 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed. 2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
71.00Supply only water seal suitable for 7.5 HP to 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed. 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
72.00Supply only coupling Rubber Bush suitable for 7.5 HP to 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
73.00Supply only shaft sleeves suitable for 7.5 HP to 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
74.00Supply only bronze impeller suitable for 7.5 HP to 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed. 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
75.00Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 7.5 HP to 12.5 HP motor pump as per manufacturer's design complete all as specified and as directed. 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
76.00M&L for rewinding of induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 7.5 HP to 12.5 HP motor capacity.1Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
77.00Supply and replacing power contactor 3 pole of suitable for 12.5 HP motor starter panel board , with NO and NC complete all as specified and directed. Make : ABB/Schneider/Siemens/L&T1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
78.00Supply and replacing power contactor 3 pole of suitable up to 7.5 HP motor starter panel board , with NO and NC complete all as specified and directed. Make : ABB/Schneider/Siemens/L&T1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
79.00Supply only in replacement adjustable CT/Direct operated thermal over load relay suitable for 12.5 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schneider2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
80.00Supply only in replacement adjustable CT/Direct operated thermal over load relay suitable upto 7.5 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schneider2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
81.00Supply only in replacement Single phase preventer for motor in the existing panel board with new one at water supply installations complete all as specified and as directed.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
82.00Supply only in replacement Star Delta timer 0-30/60 sec complete all as specified and as directed.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
83.00Supply only in replacement LED indication Lamp (R-Y-B) complete all as specified and as directed.10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
84.00M & L for servicing fire pump panel by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to fire pump panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed. Notes :- (i) Minor spare parts such as nuts, bolts, washers, indicator lamps, start, stop push button and suitable size of copper wire for internal wiring for panel are deemed to be included in quoted rate. 2Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
85.00Supply and fix in repair of GI pipe Heavy grade, jointing complete of 80 mm dia with necessary supports and specials such as tees, bends, reducers etc including consumables and painting with one coat of red oxide primer and two coat of synthetic enamel paint including making good the disturbed surfaces of wall/ ceiling etc complete all as directed.12.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
86.00Supply and fixing in replacement butterfly valve of size 80 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed2.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
87.00Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 80 mm ISI marked, CI body suitable for 200 mm dia pipe line complete all specified and directed1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
88.00Labour for pressure testing of existing 150/80/50 mm GI/MS fire main system , identifying for leakages for rectifications including replacement of gland packing of sluice valves, rubber insertion packing, nut ,bolts etc of flanged joints/ defective flanges etc complete for making the system leak proof complete all directed by Engineer-in-charge. Location : SMC Jalahalli Note: (a) The rate quoted is deemed to be inclusive of T&P required such as air compressor, pressure guage etc for pressure testing. (b) Earthwork, DI/MS pipe & specials required for rectiifcation if any shall be measured and paid separately under relevant items of BOQ. (c) The testing procedure of fire fighting system should be done as per manufacturer's recommendations.4Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
89.00M & L for servicing of Fire pump Electrical panel which operates maximum eight pump replacing by checking and servicing the contactor coil , over load relay coil and any other parts and replacing the burnt out wiring including any modification to fire pump panel by welding,cutting ,grinding ,drilling and rewiring with proper colour coding and testing the panel auto manual mode complete all as specified and directed. Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire for internal wiring of panel are deemed to be include in quoted rate. (ii) Cost of labour elements towards removing of unserviceable items & refixing of serviceable items for below mentioned supply only items will be deemed to be included in unit quoted rates.1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
90.00Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of pipelines etc in soft/loose soil, complete all as specified and directed.341.38CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
91.00Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed.198.30CumExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
92.00Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed.20.18CumExcess(+)1Full ConversionINR0.000.00INR Zero Only
93.00Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.122.90CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
94.00Material and labour for well burnt bricks ‘B’ class as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed.10.62Per 1000 Nos Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
95.00Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed. (iii) Removing excavated material out side MD land. (iv) Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.30.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
96.00Supply and laying in repair of GI pipe light grade for cable protection of size 100mm bore with fittings, complete all as specified and directed.18.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
97.00Material and labour in repair for 3 ½ core 300 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/RPG Asian300.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
98.00Material and labour in repair for 3 ½ core 150 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian150.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
99.00Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 120 Sqmm to 150 Sqmm, complete all as specified and directed.4.00Each Job Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
100.00Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 120 Sqmm to 150 Sqmm 3.5 core of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.25.00Each Job Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
101.00Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire, color, temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :- 1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
102.00(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amps 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amps 25 KA - 02 Nos. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps 10 KA - 01 No (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
103.00Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compilaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure shall be above 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :- 1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
104.00(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amp, 25 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 05 No. (c) MCB TPN, 415 V of capacity 40 Amps, 10 KA - 01 No. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 2Construction of chamber for 100mm sluices valveitem310Nos
105.00Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.24.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
106.00Material and labour in repair for 3 ½ core 120 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian150.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
107.00Material and labour in repair for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/RPG Asian250.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
108.00Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 95 Sqmm to 120 Sqmm, complete all as specified and directed.4.00Each Job Excess(+)1Full ConversionINR0.000.00INR Zero Only
109.00Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 95 Sqmm to 120 Sqmm 3.5 core of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.30.00Each Job Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
110.00Supply and fix 4 Pole MCCB, 415 volts, fixed type, 400 Amp, 50 Hz, with rupturing capacity 36 KA with thermal & magnetic setting with extended terminals,replacement to LT panel/ Feeder pillar box including connecting lugs with busbar and mounting arrengments i.e screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed. Make : Indo Asian/L&T/Havells 2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
111.00Supply and fix metal enclosure suitable for 4 pole MCCB 415 Volts 400Amp capacity complete all as speficied and directed 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
112.00Supply, installation, testing and commissioning LT Feeder pillar box CPRI Tested of Size 800x600X450 mm suitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet for outdoor panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 600 Amp and including PCC foundation as per site requirement to accomodate the following :- (a) ON Load change over 4 pole 250 Amp - 01 No. (b) LED indicating lamp R-Y-B - 06 Nos. (c) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 02 No 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
113.00Comprehensive maintenance of Automatic Power Factor Correction Panels ( APFC ) at various sub stns of capacities 250 KVAr - 01 No, 125 KVAr -1 No, 120 KVAr - 01 No, 80 KVAr - 01 No, 75 KVAr - 01 No, 70 KVAr - 01 No, 60 KVAr - 03 No, 35 KVAr - 02 No and 30 KVAr - 01 No and comprising of following works :- (i) Repair / maintenance of Contactors, Relays and Capaciters , MCCBs & MCBs provided in the APFC Panel (ii) Monitoring and effective management of power factor correction near to unity as per the veriation of load in the corrrosponding transformer in terms of serviceability of MCCB/MCBs , Contactors , Capacitors and Relay and dispaly unit inculding the following Technical services:- The following daily Maintenace to be carried out : (a) Check seviciablity of APFC panels , MCCBs/MCBs, Contactors, Relays etc. (b) Maintain a register to note the values of power factor from all APFC Panels and VCBs panel at MRS and that should be submitted to concerned JE (E/M) or AGE(E/M) . (c) Check the connection and serviciablity of incoming cable from Main LT Panels to APFC Panels (d) Checking and tightening control wiring and rectifying the defects if any.8.00Each MonthsExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
114.00Note :(i) The Contractor will responsible for maintaining the power factor near to unity on induvidual APFC Panels and overhaul the value at main Receiving Stn . Contracor shall responsible for, the penalty/ compensation charges which charged by BESCOM , due to Low Power factor and same amount shall be paid by the contractor from his own account. The above quoted rate is inclusive of all regarding to maintain the APFC Panel power factor. (ii ) The Capacitors, Contactors, Relays replaced shall be measured and Paid separetly. However, the labour element is included for replacement of wornout/ defective components. 2Construction of chamber for 100mm sluices valveitem310Nos
115.00Supply only three phase power capacitor duty contactors of following ratings including taking down old item all as directed :-1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
116.00 5 KVAR Make : L&T/ Siemens (Epcos)/ Schneider/ABB4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
117.00 10 KVAR Make : L&T/ Siemens (Epcos)/ Schneider/ABB4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
118.00 12.5 KVAR Make : L&T/ Siemens (Epcos)/ Schneider/ABB3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
119.00 20 KVAR Make : L&T/ Siemens (Epcos)/ Schneider/ABB4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
120.00 25 KVAR Make : L&T/ Siemens (Epcos)/ Schneider/ABB2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
121.00 50 KVAR Make : L&T/ Siemens (Epcos)/ Schneider/ABB1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
122.00Supply only TP, MCB 20 to 32 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian/Schenider/ABB10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
123.00Supply only contactor suitable for 5 KVAr Capacitor Make - L&T /BCH/Schneider2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
124.00Supply only contactor suitable for 10 KVAr Capacitor Make - L&T /BCH/Schneider2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
125.00Supply only contactor suitable for 12.5 KVAr Capacitor Make - L&T /BCH/Schneider3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
126.00Supply only contactor suitable for 20 KVAr Capacitor Make - L&T /BCH/Schneider2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
127.00Supply only contactor suitable for 25 KVAr Capacitor Make - L&T /BCH/Schneider2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
128.00Supply only contactor suitable for 50 KVAr Capacitor Make - L&T /BCH/Schneider1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
129.00Supply and fixing in replacement MCB SP 6A Make - Make - L&T/Havells/Indoasian3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
130.00Supply and fixing in replacement MCB SP 16A Make - Make - L&T/Havells/Indoasian3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
131.00Supply and fixing in replacement MCB SP 63A Make - Make - L&T/Havells/Indoasian3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
132.00Supply and fixing in replacement MCB SP 32A Make - Make - L&T/Havells/Indoasian4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
133.00Supply only Electric cooling fan single phase 240 Volts suitable for APFC panel 2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
134.00Supply only APFC relay square flush type with Intelligent Power Factor Controller complete all as directed. Make :GE/EPCOS/ABB 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
135.00Supply only Indicator lamps (RYB) complete all as specified and directed.20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
136.00Supply and fixing in replacement wiring of APFC panel with including copper wire ,PVC wire holder and other connected items suitable for APFC panel 30 KVAr to 250 KVAr capacity as per existing make including testing and complete all as specified and directed.2.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
137.00Supply , fabricating ,installation,testing and commissioning 200 KVAr APFC Panel out door type weather proof ,dust vermine proof (CPRI approved) APFC Panel made out of 3.15 mm thick CRCA sheet front openable type and suitable for operation on 415 Volts ,50 Hz ,AC supply and fixed on angle iron frame /channel of suitable size complete ,alluminium bus bar ,cable gland brass chromium plated of different size suitable for incoming and out going cable. Panel Painted with powder coated paint including necessary PCC (1:3:6) foundation plateform of suitable size infront of the panel complete all as specified and directed including taking down of old unsv one. (a) MCCB 400 Amps 4 pole 25 KA with microprocessor release type - 01 No . (b) 200 KVAr Capacitor 16 Step with fitting fixture. (c) Multifunction Meter (V,I,PF) with CT's - 01 No. (d) APFC Controller for 16 Step-01 No. (f) Panel exhaust fan as required.1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
138.00M&L for servicing of 3-phase 12 KW online inverter/PCU system with solar input, battery backup, and integrated inverter functionality, including complete shutdown of DC input (400V–740V DC), AC input (415V ±15% 3-phase), and AC output (400V AC ±1% phase-to-phase); opening of enclosures; cleaning of internal components using antistatic materials; inspection and testing of MPPT circuitry, DC bus, IGBT/SiC modules, thermal sensors, cooling systems, PCBs, protective fuses, contactors, and LCD/display modules; insulation resistance testing between input-output and ground; thorough battery bank maintenance including cleaning of terminals, tightening, electrolyte top-up (if flooded), voltage equalization, float/equalization charge verification, and overall health check; complete UPS system testing including rectifier, inverter, static bypass, charger, and simulated failure testing under load; reassembly, safe reconnection of all terminals, inverter restart, grid sync all carried out as per OEM procedure and standard EHS/safety norms. Note:- (a) Spares and replacement components such as IGBTs, capacitors, fuses, fans, display units, etc., shall be measured and paid separately under relevant items listed below. (b) Cost of labour, consumables, testing equipment, transportation, and documentation shall be deemed included in the quoted rate. (c) The inverter system shall be serviced, repaired, and fully restored to operational status within 5 working days from the date of complaint lodged by AGE/JE E/M. (d) In case of any delay beyond 5 days, the contractor shall provide a temporary inverter or equivalent power backup arrangement to maintain uninterrupted operation. (e) Failure to restore services within the stipulated period or provide alternate backup will attract a penalty of ₹1000 per day. (f) This penalty clause shall be applicable independently and in addition to Condition 67 of IAFW-2249. (g) The decision of the Accepting Officer shall be final and binding on all related technical or contractual matters.1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
139.00Supply only of electronic mother board/card of online inverter suitable for 12 KW solar Plant complete all as specified and directed .1.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
140.00Supply only of IGBT power module suitable for 3-phase string inverter/PCU (rating up to 12 KW), rated for high-speed switching, thermal protection, and suitable voltage/current rating as per OEM specifications; fully compatible with inverter topology; conforming to IS/IEC standards; supplied in moisture-proof anti-static packaging with traceability code complete all as specified.3.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
141.00Supply only of input/output power capacitor module, rated for 800V DC and ripple current tolerance as per inverter design, suitable for smoothing DC bus and suppressing voltage spikes; high-temperature, long-life grade type with low ESR; conforming to IEC 61071; fully compatible with 15 KW inverter design complete all as directed.1.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
142.00Supply only of inverter control/display module, comprising OEM-specified LCD/TFT display with integrated control PCB, membrane keypad/touch panel, and communication interface (RS485/CAN/Ethernet as applicable), suitable for front panel mounting in inverter cabinet; supplied pre configured and tested complete all as specified.1.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
143.00Supply only of inverter cooling fan assembly, industrial grade axial or centrifugal type as per inverter model, 230V/24V operation, sleeve or ball bearing design with minimum 40,000-hour MTBF, supplied with protective grill and connector, fully compatible with inverter thermal control system complete all as specified and directed .1.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
144.00Supply only of DC fuse link with base, rated for 1000V DC and current rating as per inverter string input (typically 15A to 30A), cylindrical type, gPV/gR class as per IEC 60269-6; supplied with high-insulation ceramic body, silver-plated contacts, and suitable fuse holder/base for DIN rail or panel mounting complete all as specified and directed .1.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
145.00Supply only of temperature sensor/NTC/PT100/PTC module, compatible with inverter thermal protection logic, suitable for heatsink or IGBT temperature feedback, with connector, mounting clip/paste, and calibration data complete all as specified and directed .1.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
146.00Supply only of SPD of 10 KV suitable for 12 KW solar Plant complete all as specified and directed .2.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
147.00M&L for comprehensive repair and servicing of solar DC Distribution Board (DC DB) rated for up to 1000 V DC and 50 A per input, suitable for connection with 3-phase 12 kW string inverter, including isolation of solar input, opening and inspection of the enclosure, cleaning, tightening of all terminals and busbars, testing insulation resistance, and replacement of defective or unserviceable components such as solar-grade MCBs, SPDs (Type 2/Class II, DC rating), DC fuses with holders, isolators, LED indicators, terminal blocks, cable glands, and associated wiring with new components of equal or higher capacity; reassembling and conducting full functionality and polarity tests to ensure reliable performance under full load conditions; and restoring the board to original working condition as specified and as directed by the Engineer-in-Charge. The quoted rate shall be deemed to include all materials, spares, tools, consumables, testing equipment, and labour required for a complete all as specified and directed .1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
148.00M&L for attending fault and repairing AC Distribution Board (AC DB) connected to 3-phase 12 kW string inverter, including opening of panel, checking internal connections, cleaning, tightening of loose terminals, insulation testing, and replacement of defective components such as MCBs (415V, 63A/32A TP/DP), surge protection devices (SPD, 385V, Type 2, 20–40kA), MCCBs (100A–125A, 4P), selector switches, indicator lamps, cable glands, busbars, and internal wiring using appropriate size multi-strand copper cables; ensuring proper phase balancing and safety interlocking as required. Work includes testing and commissioning after repair, insulation resistance check (IR >1MΩ), proper earthing continuity verification, and restoring full functionality of the AC DB. All as per site condition, safety norms, and direction complete, all as specified and directed . 1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
149.00M&L for complete rewinding of 3-phase transformer suitable for 12  kW solar string inverter, including dismantling of the transformer from inverter housing, de-soldering of terminal connections, and thorough inspection to detect shorted turns, insulation breakdown or winding failure; removal of all damaged HV and LV windings from the magnetic core; cleaning of core laminations using non-corrosive solvent; rewinding with new super-enamelled copper wire of appropriate gauge as per original winding configuration; replacement of all insulation materials such as interlayer insulation, phase barriers, insulating sleeves, wedges, and varnish cloth; vacuum impregnation of coils with Class F/H grade varnish followed by oven baking and curing; reassembly of core and coils with proper clamping and alignment; connection of windings to terminals with suitable high-temperature lugs; installation back into inverter cabinet; complete testing including insulation resistance (IR), turns ratio, open circuit voltage, short circuit current, and full load test for minimum 1 hour to confirm operational reliability. The work includes all consumables, copper winding wire, insulation materials, lugs, fasteners, varnish, labour, transport, and testing all as per OEM standards and complete all as specified and directed.1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
150.00Material and labour for battary electrolyte grade 1250 complete all as specified and directed.20.00LtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
151.00Material and labour for distilled water in 5 ltr/ 2 ltr sealed cane to be filled in batteries complete all as specified and directed.60.00LtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
152.00Taking down and errecting steel swaged tubular pole 8.5/9 mtr long, bracket for fixing street light and refixing the same including necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation size of 50 x 50 x 45 cm and coping with 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specified and directed. 2.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
153.00M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to pole including necessary form work slightly rounding or squaring, complete all as specified and as directed.2.50CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
154.00M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for poles and filling around fencing posts etc, complete all as specified and as directed3.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
155.00Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with black up to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation and coping as per TD drawing including dismantling of old damaged pole complete all as specified and as directed.Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate. 4.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
156.00Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 300x200x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed. 10.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
157.00Supply and fix in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed.20.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
158.00Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 90 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj12.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
159.00Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor including taking down of old one complete all as specified and directed. Make: Plaza/Polycab/ Finolex/Havells180.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
160.00Material and labour for applying one coat of cement base paint to RCC pole 7/9.0 metre long after scraping / brushing and cleaning the pole and street light bracket to be painted with one coat of Aluminium paint. Cement base paint shall be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white with synthetic enamel paint (30 Cms Each) Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete, all as specified and directed.50.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
161.00Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed. 20.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
162.00Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 60 to 72 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
163.00Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/Havells250.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
164.00Material and labour for Painting of steel tubular pole 7/9.0 metre long, by applying one coat of aluminium paint after scraping / brushing and cleaning the rust on pole and street light bracket. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white with synthetic enamel paint (30 Cms Each). Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete all as specified and directed.100.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
165.00Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity. The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :- 1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
166.00(a) TPN MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No. (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, C&S Havells) (b) Supply Resign cast CT'S - set of 3 (c) GSM based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 32 Amps -02 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 06 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 Amp rating with brass contacts for INPUT/ and 63 Amp for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring 10 Sqmm flexible. Make- Tricolite/ Kewintech/HPL1.02Construction of chamber for 100mm sluice platesitem2213Nos
167.00Supply only of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed.30.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
168.00Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian500.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
169.00Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian400.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
170.00Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 4 core 10 Sqmm to 16 Sqmm, complete all as specified and directed.8.00Each Job Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
171.00Supply and fixing in repair LED flood light 200 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lamp Protection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj 4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
172.00Suply and fix in repairs LED decorative post top lantern fitting 40W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection complete all as specified as directed. Make: Bajaj / Philips/Halonix/ CG5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
173.00Supply and fixing in repair Round spherical garden lighting, post top lantern having B22 holder suitable for LED bulb 10 watt, 220 volt,50HZ,IP65 including suitable of GI tubing ,length as per site requirement on gate pillars/ garden lights for fixing the lamp, wiring with 1.5 Sqmm PVC insulated stranded copper conductor including PCC work for fixing, of light fitting complete all as specified and directed.Make: Philips/ Havells/Bajaj/CG.15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
174.00Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 10 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/ Havells150.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
175.00S & F aluminum lugs suitable for aluminum cable of size 10 to 35 Sqmm complete all as specified and directed 65.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
176.00S & F aluminum lugs suitable for aluminum cable of size 50 to 95 Sqmm complete all as specified and directed 55.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
177.00S & F aluminum lugs suitable for aluminum cable of size 120 to 185 Sqmm complete all as specified and directed 45.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
178.00S & F copper lugs suitable for copper cable of size 240 to 300 Sqmm complete all as specified and directed 32.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
179.00Supply and fixing in repair IP65 rated LED Bollard with robust design and efficient light distribution 10 watt on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc., including taking down existing fittings all as specified and directed Make : Crompton/ Halonix/Bajaj/ Philips6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
180.00Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 140x140x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32 No including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed. 12.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
181.00Supply and fixing in repair LED flood light 150 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lamp Protection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj 6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
182.00Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 12 KW 3 phase 32 amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal whether proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1 for grouting of base including taking down unserviceable panel. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity. The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed including the following subcomponentSupply and fixing eatures :- 1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
183.00(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) Gsm based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 03 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible. Make- Tricolite/ Kewintech/HPL2Construction of chamber for 100mm sluices valveitem310Nos
184.00Supply and fix in repair smart integrated solar all in one LED solar street light fitting 12 V,15 Watts with IP 66 protection, built-in MPPT charge controller,Lithium ion battery,mono crystalline solar panel, PIR motion sensor complete with anodised reflector, toughened heat resistant glass cover, LED 12 watts white colour lamp, connector block with all accessories pre wired including bracket,welding,drilling,bolts,nuts and any alteration required for fixing the panel with existing pole, complete all as specified and as directed. Make:Philips/CG/Havells/Bajaj4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
185.00Supplying, errecting and fixing as in repair GI tubular swaged welded pole of over all height 6.0 m long for all in one solar light complete with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed . 4.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
186.00Supply, installation, testing and commissioning LT Feeder pillar box double door CPRI Tested of Size 400X250X350mm suitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet of outdoor of panel with angle iron frame of size 32x32x5mm cubical type complete with aluminium bus bar 100 Amp and including PCC foundation as per site requairment to accomodated to the following. INCOMING (a) MCB TPN 32 Amp 10 KA - 01 No. (b) LED indicating lamp R-Y-B - 03 Nos. OUTGOING (a) Weather Proof panel Plug and shocket angled type IP 67 three Phase 3P+N +E, 20 Amp - 01 No (b) Weather Proof plug and shocket angled type IP 67 Single Phase 2P+E , 20 Amp - 01 No. (a) MCB TPN 20 Amp 10 KA - 01 No. (a) MCB SPN 20 Amp 10 KA - 01 No. 2.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
187.00Comprehensive maintenance passengers lift to carry 13 passengers (884 Kg) capacity of Make: Schindler to serve ground floor and two upper floors with AC variable voltage & variable frequency drive(VVVF DRIVE) system, microprocessor based control system all as per IS 14665 hall position indicators on all floors, car position indicators in cabin, battery operated alarm bell and emergency lights including cabin light & fan over load switch, auto revelling, intercom facility with centre opening, stainless steel power operated sliding doors, including Examining the operation, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell , etc. complete all as specified and directed. Location : SMC - 02 Nos Note: (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only. (b) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately. 8.00Per MonthExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
188.00Supply only shaft information switch as per existing model suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
189.00Supply only shaft information card as per existing model suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
190.00Supply only infrared door sensor as per existing model and size suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
191.00Supply only Relays as per existing model suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
192.00Supply only Landing Floor indicators as per existing model suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
193.00Supply only Rectifiers as per existing model suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
194.00Supply only OSG pulley top complete as per existing model suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
195.00Supply only OSG pulley bottom complete as per existing model suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
196.00Supply only for main contactors as per existing model suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
197.00Supply only travelling cable as per existing model and size suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.100.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
198.00Supply only Limit switch as per existing model suitable to 13 passengers (884 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
199.00Comprehensive maintenance passengers lift to carry 08 passengers (554 Kg) capacity of Make: Schindler to serve ground floor plus two floors, including Examining the operation, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell, etc complete all as specified and directed. Location : SMC - 01 No Note: (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only. (b) The rate quoted shall be deemed to include for carried out all repairs to lift noticed during the period by providing materials and labour. 8.00Per MonthExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
200.00Supply only shaft information switch as per existing model suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
201.00Supply only shaft information card as per existing model suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
202.00Supply only Relays as per existing model suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
203.00Supply only for main contactors as per existing model suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
204.00Supply only travelling cable as per existing model and size suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.100.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
205.00Supply only Rectifiers as per existing model suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
206.00Supply only Landing Floor indicators as per existing model suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
207.00Supply only OSG pulley top complete as per existing model suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
208.00Supply only OSG pulley bottom complete as per existing model suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
209.00Supply only infrared door sensor as per existing model and size suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
210.00Supply only Limit switch as per existing model suitable to 08 passengers (554 Kg) capacity of Make: Schindler complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
211.00Supply and fixing ARD system in case of mains power failure and Lift control system failure, the Lift’s own rechargeable and maintenance free battery power shall move the car to the nearest floor and the door shall open automatically for automatic rescue of passengers. A battery run-down indicator shall be provided complete with the battery charger and make the system functional all as specified and directed..1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
212.00Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V, upto 18 AH, suitable for passenger/ goods lift as required at location : SMC including initial charging complete with inbuilt charger including taking down of old battery and shifting to MES store yard for deposit all as directed. by Engineer in Charge complete all as specified. Make of battery : Exide / Amar raja / Amaron Note :- (i) The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation. (ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Chare throughout the currency of contract.6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
213.00Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed. 242.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
214.00M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/existing concealed conduit/PVC casing-caping etc as per site requirement on walls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etc complete for the following :- Make of wire: Polycab/Plaza/Havells Note: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
215.00All as per item No. 214 here in before but for One light point/fan point controlled by one way 5 Amp switch.30.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
216.00All as per item No. 214 here in before but for One light point controlled by two way 5 Amp switch.5.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
217.00All as per item No. 214 here in before but for one bell point controlled by one way bel push.10.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
218.00All as per item No.214 here in before but for One 3 pin socket out let 5 Amp on the same board20.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
219.00All as per item No. 214 here in before but for one switch socket outlet 3 pin 5 Amps on independent board20.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
220.00All as per item No. 214 here in before but for Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.8.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
221.00All as per item No. 214 here in before but for Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.12.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
222.00Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian50.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
223.00Supply and Fix switch piano flush type 5 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian 5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
224.00Supply and Fix switch piano flush type 5 Amps 240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
225.00Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
226.00Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
227.00Supply and Fix shuttered switch socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian 20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
228.00S & F ceiling rose surface bakelight two to three terminal complete all as specified and directed Make : Anchor/Havells/L&T 150.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
229.00S & F 2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton120.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
230.00S & F electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/Havells/L&T25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
231.00S & F fan regulator 120W, for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T 25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
232.00Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.400.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
233.00S&F in repair of new PVC conduit medium grade of size 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Supreme/Diplast/Avon plast35.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
234.00S&F in repair of new PVC conduit medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /alluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Supreme/Diplast/Avon plast30.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
235.00M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/ PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.230.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
236.00S&F in replacement factory made powder coated distribution board SPN 12 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
237.00S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
238.00S & F MCB in repair and replacement of SPN 240 volts 16 to 40 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
239.00Supply & fix in repair decorative surface mounted ultra slim Square/Round profile 18 W LED(WW/WH) lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 18 Watt and including cosidering material & labour for fixing ceiling hight upto 7.5 Mtr, complete all as per site requirement and directed Make : Philips/ Bajaj / CG/Havells.5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
240.00Supply & Fixing in replacement of electronic LED driver 18/20 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed .10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
241.00M&L for cutting of hole through brick wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.2.00Each jobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
242.00Supply and fixing Exhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed.Make : Havells/ Bajaj/ Orient/USHA. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard without any extra cost to the deptt.10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
243.00M&L for in repair louver made of steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsible of the contractor.15.00Each jobExcess(+)1Full ConversionINR0.000.00INR Zero Only
244.00S&F in replacement factory made powder coated distribution board SPN 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
245.00S&F in replacement distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
246.00S&F in replacement factory made powder coated distribution board TPN, 4 way double door MCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB complete all as directed Make : Indoasian/ Havells/ Legrand.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
247.00S & F in repair and replacement TPN, MCB 40 to 63 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
248.00Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.135.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
249.00M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealed rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame , concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/Havells Note: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). 3Supplying, Conveying and fixing spls. Including eaitem410Nos
250.00All as per item No. 249 here in before but for one light point/fan/bell point controlled by one way switch.40.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
251.00All as per item No. 249 here in before but for one light point controlled by two way switch.6.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
252.00All as per item No. 249 here in before but for one bell point controlled by one bell push.12.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
253.00All as per item No. 249 here in before but for one 3 pin socket out 5 Amp on the same board20.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
254.00All as per item No. 249 here in before but for one switch socket outlet 3 pin 5 Amps on independent board25.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
255.00All as per Sl No. 249 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.8.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
256.00All as per Sl No. 249 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.18.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
257.00Supply and Fix modular switch 1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian 85.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
258.00Supply and Fix modular switch 2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
259.00Supply and Fix modular switch bell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian12.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
260.00Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian45.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
261.00Supply and Fix modular switch 1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian26.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
262.00Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian 26.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
263.00Supply and fix White cover plate with frame,2/3 module30.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
264.00Supply and fix White cover plate with frame,4 module45.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
265.00Supply and fix White cover plate with frame,8 module20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
266.00Supply and fix White cover plate with frame,6 module35.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
267.00Supply and fix White cover plate with frame,12 module25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
268.00S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directed Make : Legrand/ Crabtree/ Anchor 45.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
269.00S&F in replacement factory made powder coated distribution board VTPN, 4 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB complete all as directed Make : Indoasian/ Havells/ Legrand.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
270.00S & F in repair and replacement of MCB single pole 240 volts 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
271.00S&F as in repair PVC casing capping medium grade of size 32 mm on wall /roof with help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make: Polycab/ Modi/ Presto Plast40.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
272.00S&F as in repair PVC casing capping medium grade of size 25 mm on wall /roof with help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make: Polycab/ Modi/ Presto Plast45.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
273.00M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/ PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.120.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
274.00S&F in replacement factory made powder coated distribution board VTPN, 8 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB complete all as directed Make : Indoasian/ Havells/ Legrand.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
275.00S & F in repair and replacement TP, MCB 40 to 63 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
276.00S&F in repairs LED bed side light /wall light/study light environmentel friendly energy effcient of capacity 3 W warm white etc,inbuilt driver complete with all accessories internally pre-wired swing type and including connecting up to with twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj / Philips / Wipro/CG32.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
277.00Supply & Fixing in replacement of electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed .25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
278.00M&L for cutting of hole through stone wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.2.00Each jobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
279.00Supply and fixing Exhaust fan 250 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make : Havells/ Bajaj/ Orient/USHA. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.20.00Each jobExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
280.00M&L in repair for stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/wooden beading fixed on wall including necessary fixing arrangement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsibility of the contractor 15.00Each jobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
281.00Supply and Fix in repair and replacement of surface mounted Square/Round for LED 18W Watt downlights made of extruded Aluminium housing and high power LED light source with Driver clear diffuser with separate electronic driver with complete accessories all as specified and directed.Make : Philips/ Bajaj / CG/Havells. 15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
282.00Refixing existing serviceable LED light fitting fixture any capacity and of any type complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size after cleaning all dust etc. complete all as specified and as directed . 5.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
283.00Supply & Fixing in replacement of electronic LED driver 35/36 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed .25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
284.00S & F in replacement 9 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton 75.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
285.00Supply and Fixing in repairs of wall focus track light 18 watt WW an operating voltage range from 140V-270V complete all as specified and directed. Make: Philips/Lukar/Bajaj/CG3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
286.00Supply and Fixing in repairs of channel 2 Mtr length for focus track light complete all as specified and directed. 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
287.00S&F in replacement factory made powder coated distribution board SPN 6 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
288.00S&F in replacement factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
289.00S & F MCB in repair and replacement of SPN 240 volts 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
290.00S & F in repair and replacement of MCB single pole 240 volts 6 to 40 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian80.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
291.00S&F as in repair PVC casing capping medium grade of size 20 mm on wall /roof with help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make: Polycab/ Modi/ Presto Plast55.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
292.00Supply and fixing in repair building security/ LED street light fitting 36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
293.00Supply and fix GI pipe 32 mm dia, medium grade for mounting bracket, bent to shape 1.5 meter length and fixing arrangement with two Nos of clamps set, nut, bolts, washers, and incl taking down old unserviceable GI pipe complete all as specified and directed 25.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
294.00Point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSH cable 1100 volts grade with stranded copper conductor in and including rigid steel ERW concealed conduit and conduit accessories in wall, floors and ceiling including PTFE(Teailon) type sealing of joint along with continuous earth wire 1.5 Sqmm PVC insulated and unsheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including suitable standard accessories complete for one No. flame proof light point/ one fan point /one exhaust fan controlled by one way flame proof switch all as specified and directed. Make of Cable : Plaza/ Polycab/ Havells 8.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
295.00Supply and fix Switch flame proof rotary type with termination box in LM6,16 A, single pole 250V all as specified and directed.Make : Sudhir/Bajaj/Baliga8.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
296.00Material and labour for Flame proof junction box in LM6 upto 1" and upto 4 way complete all as specified and directed.Make- Sudhir/ Shyam Switchgear/Baliga8.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
297.00Supply and fixing flame proof exhaust fan of sweep size 300 mm,single phase,230V including louvers and blades complete all as specified and directed. Make- Sudhir/ Shyam Switchgear/Baliga1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
298.00S & F LED tube light fitting flameproof type suitable for single tube 20 W LED integral built in control box made of aluminium alloy LM6 , IP65 with all accessories, complete all as specified and as directed. Make- Sudhir/ Shyam Switchgear/Baliga10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
299.00Material and labour for disconnecting carefully electrical connection from both HT/ LT (primary & secondary) sides of the transformer, keeping them at safe side and taking out the transformer indoor/ outdoor type of capacity 100 KVA to 400 KVA, 11 KV/ 0.433 KV, step down any make for carrying out complete overhauling which shall comprise of the following:- 2.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
300.00(a) Lifting, transporting, handling, the transformer to workshop and opening top cover of the transformer by unscrewing nuts, bolts, washers etc. including disconnecting core assembly from HT/ LT bushing and lifting the same gently and taking out from the shell (container/ body) of the transformer. 3Supplying, Conveying and fixing spls. Including eaitem410Nos
301.00(b) Draining out transformer oil from the above said transformer in the suitable capacity of container /drums and keeping it in safe custody for reuse.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
302.00(c) Cleaning the transformer body from inside, removing deposited dirt/ sludge/ foreign particles etc. from the bottom/ body of the transformer and drying up the shell from inside before refilling of the transformer oil.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
303.00(d) Cleaning and washing thoroughly core and windings of the transformer by hosing down with clean dry oil conforming to IS 335/1983, removing deposited dirt/sludge/foreign particles from the windings/ core, thorough inspection of windings, providing insulations to leads and terminals, heating/ drying/ baking complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc. all as per IS 1986-87 and directed.2Construction of chamber for 100mm sluices valveitem310Nos
304.00(e) Lifting and refixing core assembly inside the transformer shell gently and carefully, connecting primary/ secondary/ Neutral connections to the bushings assembly, fixing of tap change over including tightening of nuts, bolts, washers of the core to reduce humming noise all as directed.2Construction of chamber for 100mm sluices valveitem310Nos
305.00(f) Refilling the filtered transformer oil in the shell of transformer complete.3Supplying, Conveying and fixing spls. Including eaitem410Nos
306.00(g) Refixing the top cover including replacement of cork sheet/ gasket 8mm thick, tightening of nuts/ bolts/ washers etc. and replacement of breather with silica gel crystal type all as directed.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
307.00(h) Lifting/ shifting to the place from where removed and re-installing the transformer including connecting primary/ secondary/ neutral / earth connections etc. all as directed.1.02Construction of chamber for 100mm sluice platesitem2213Nos
308.00(j) The inspection of transformer shall includes :- (i) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts. (ii) Checking all brazings, joints, tap heads and connection joints. (iii) Checking all jumpers, terminations/ connections inside the transformer. (iv) Checking the Buchholtz relay/ conservator MOG if any. (v) Painting of transformer complete with two coats of synthetic enamel paint externally transformer shell complete all as directed. (vi) Inspection of tap changer, checking the moving and fixed contacts for contact wear and connection to winding.2Construction of chamber for 100mm sluices valveitem310Nos
309.00Note:- (i) Any damage to insulators/ bushes/ windings etc. while in the custody of the contractor shall be made good at no extra cost to govt. The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody. (ii) M&L for rewinding re-insulation of HT/ LT (primary/ secondary) coils, bushes, studs, Transformer oil,cable box, replacement of buchholtz relay/ MOG if any etc will be measured and paid separately. 2Construction of chamber for 100mm sluices valveitem310Nos
310.00M&L for rewinding of HT coils / LT coil of transformer with super enameled copper wire / strips to match with existing gauge or as recommended by the manufacturer for turn ratio and impedance including requisite paper / insulation material in each layer of winding complete all as specified and as required.150.00KGExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
311.00Filtration of transformer oil of transformers installed at various locations to achieve di-electric strength not less than 60 KV for 1 minute at 2.5 mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as directed. Note :- a) The rate quoted shall be deemed to include for taking necessary conections to filteration plant from transformer and switch gear oil duly removing the inlet and out let connections. (b) Electric supply for the filteration plant will be made available free of cost. (c) The dielectric strength value of the transformer oil shall be tested before & after filtration. And such testing shall be carried out twice in a year as specified and directed. (d) Test reports shall be enclosed at the time of claiming payment.4000.00LtrExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
312.00Supply and topping up or replacement of transformer oil with di-electric strength not less than 60 KV in to the conservator tank/ body tank of the transforme etc at various locations complete all as specified and as directed.250.00LtrExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
313.00Material and labour for replacement of silica gel breather assembly for HT distribution transformers of 100 KVA to 400 KVA capacity including dismantling old one all as specified and as directed 2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
314.00Material and labour for replacement of silica gel for HT distribution transformers of upto 400 KVA capacity including dismantling old one all as specified and as directed 5.00KgExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
315.00Material and labour for replacement gun metal drain valves of transformers from 100 KVA to 400 KVA capacities including dismantling old one all as specified and as directed. 2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
316.00Material and labour for replacement of the LT porcelain bushings complete of transformer from 100 KVA to 200 KVA capacity distribution transformers of existing transformer make/ size/ type including dismantling old one all as specified and as directed .2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
317.00Material and labour for replacement of the LT porcelain bushings complete of transformer from 250 KVA to 400 KVA capacity distribution transformers of existing transformer make/ size/ type including dismantling old one all as specified and as directed .3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
318.00Material and labour for replacement of the HT porcelain bushings complete of Transformer from 100 KVA to 200 KVA capacity distribution transformers of existing transformer make/ size/ type including dismantling old one all as specified and as directed .2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
319.00Material and labour for replacement of the HT porcelain bushings complete of Transformer from 250 KVA to 400 KVA capacity distribution transformers of existing transformer make/ size/ type including dismantling old one all as specified and as directed .3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
320.00Material and labour for replacement of the LT bushing rod made out of gun metal with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc. complete from 100 KVA to 200 KVA capacity distribution transformers of any make/ size/ type including dismantling old one all as specified and as directed 4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
321.00Material and labour for replacement of the LT bushing rod made out of gun metal with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc. complete from 250 KVA to 400 KVA capacity distribution transformers of any make/ size/ type including dismantling old one all as specified and as directed 4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
322.00Material and labour for replacement of the HT bushing rod made out of gun metal with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc. complete from 100 KVA to 200 KVA capacity distribution transformers of any make/ size/ type including dismantling old one all as specified and as directed 4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
323.00Material and labour for replacement of the HT bushing rod made out of gun metal with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc. complete from 250 KVA to 400 KVA capacity distribution transformers of any make/ size/ type including dismantling old one all as specified and as directed 4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
324.00Material and labour for replacement of (OTI) Oil Temperature indicator suitable for 100 to 400 KVA capacity distribution transformers including dismantling old oneall as specified and as directed. 4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
325.00Material and labour for preparation of old painted surfaces of transformers with coarse cloth/ brush and painting throughout externally on exposed surfaces with two coats of smoke grey colour synthetic enamel paint or approved colour as directed including writing of SM/MES Number on transformer and transformer details on plinth in white enamel paint on black enamel paint back ground complete including one coat of white wash for base foundation all as specified and directed by Engineer-in-charge for 100 to 400 KVA capacity indoor / outdoor type transformer 4.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
326.00Repair and servicing of HT 11KV out door type Ring main unit (RMU) of capacity 400 to 630 Amps by opening and replacing all unserviceable parts, cleaning and tightening the terminals, checking the control circuit wiring, spring charging and interlocking mechanism and ascertaining the RMU healthiness for faults tripping system by using secondary injection method and checking breaker, closing coils, checking the tripping circuit and resetting trip values of relays and checking tripping machanism including servicing of the LBS complete by engaging well experienced technicians as per manufacturer recommendation and all as directed by Engr in Charge. Note: Spare parts shall be measured and paid separately under relevant items. The rated quoted shall deemed to be inclusive of minor spares such as screws, bolts, nuts and all consumables.4.00Each Job Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
327.00Supply only the following spares suitable for 400 to 630 Amp Amps HT RMUs repair work under above schedule items1.02Construction of chamber for 100mm sluice platesitem2213Nos
328.00(i) Bushing Bolted Type2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
329.00(ii) Trip coil as per the existing make and type1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
330.00(iii) Push Button Green/Red W/ Label "O"2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
331.00(iv) Spike Mechanism w/o hex rod1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
332.00(v) Capacitor Unit, VPIS, 9-15kV without cord1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
333.00(v) Battery of 1.5 V suitable for RMU1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
334.00Supply and fixing in replacement of DC wiring of RMU panel with including copper wire ,PVC wire holder and other connected items suitable for RMU panel 630 A capacity as per existing make including testing and complete all as specified and directed.1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
335.00Supply only the current transformer of ratio 100/01 suitable for 400 to 800 Amps 250 MVA to 450 MVA HT switch gear (VCBs) and 11 KV HT panel repair work under above schedule items, all as specified and directed.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
336.00Material and labour for three phase PT of ratio 11000/110V, burden 100VA, class1.0 ,voltage factor 1.2 countinuous confirming top IS -3156/1992 including fuse unit disconnecting carefully HT electrical connection from PT and taking out the old unserviceable PT and connecting carefully electrical connection testing complete all as specified. 3.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
337.00Material and labour for plain cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate for path ways, hard standing & pole coping including necessary form work and applying two coats of white wash on exposed surfaces etc complete all as specified 3.50CUMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
338.00Material and labour for cross arms, bracings, supports, clamps and back plates, fabricated from structural steel including nuts, blots, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed inclusive of one primer coat, one under coat and one finishing coat of aluminum paint all as specified and as directed.0.50QtlExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
339.00Material and labour in replacement for danger notice plate of 1.6mm thick mild steel sheet with vitreous enamelled with letter figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT, of size 25 x 20cm all as directed and as specified.6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
340.00Material and labour as in repair for fixing arial fuse wire of suitable size for HT 11 KV drop out fuse carrier up to 15 A rating complete all as specified and as directed.0.85KGExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
341.00Material and labour in replacement for lightning arresters for outdoor use expulsion type suitable for 11000 volts (HT) complete with all fittings, transmission class, dis-charge capacity 65 KA including taking down existing lightening arresters of any type and size all as directed.1.00Set of 3Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
342.00Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the grass weeds etc in the sub station yards after removing stone aggregate aside all as directed at site including setting / spreading back the aggregate complete all as specified and directed at site. Note:- (i) Additional stone aggregate required shall be measured and paid separately under relevant items of this schedule. (ii) The rate also deemed to be included for labour (iii) The sub station yards shall be kept clean through out the contract period by removing the grass/weeds as many as times required depending on the growth of the grass. (iv)The rates shall be deemed to includes the cost of removing two time the grass,weeds,debris,excess soil etc to a distance not less than 50 M and keeping the excavated surface clean and levelled all as directed.3000.00Sqm Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
343.00Supply and spreading stone aggregate of size not exceeding 40 mm spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for transformer and pole structure area all as directed6.00CUM Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
344.00Supply and fixing as in repair HT tape roll 35mm width Appx 5 mtr length all as specified.10.00Each RollExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
345.00Repair and servicing of HT 11KV LBS of capacity 400 Amps to 630 Amps by opening and replacing all unserviceable parts, cleaning and tightening the terminals, checking and greasing of charging mechanism and fault tripping system including servicing of the LBS complete by engaging well experienced technicians as per manufacturer recommendation and all as directed . Note: Spare parts shall be measured and paid separately under relevant items. The rated quoted shall deemed to be inclusive of minor spares such as screws, bolts, nuts and all consumables.1.00Each Job Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
346.00Supply only the following spares suitable for 400 to 630 Amps HT Load Breaking Switch repair work under above schedule items :-2Construction of chamber for 100mm sluices valveitem310Nos
347.00(i) High repturring capacity fuse unit upto 400 Amps as per sample and suitable for housing in Megawin make out door LBS unit1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
348.00(ii) Operating mechanism spring as per sample1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
349.00(iii) Trip Coil suitable for HT LBS as per sample1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
350.00(iv) Fuse holder assembly suitable for 400 Amps HT LBS as per sample1.00Set of 3Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
351.00Supplying and laying reinforced precast concrete cable cover, class EHV, type 2 with flat, size 450mm x 180mmx 40mm, all as specified and as directed.210.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
352.00Supply, lay, test and commissioning of XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cable (HT UG), 11000 volts grade with stranded aluminium conductor of size 3 core 95 Sqmm (Earthed) including taking out existing unserviceable cable complete all as specified and as directed. Make: Havells/Polycab/RPG Asian Note - Earthwork and bricks to be measured and paid separately under respective items.35.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
353.00Material and labour for cable jointing kit for 11KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
354.00Material and labour for cable jointing kit for 11KV (Earthed) grade cable for out door straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
355.00Material and labour for cable jointing kit for 11KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
356.00M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. including excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core complete all as specified and as directed. Notes : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 8 hours of receipt of intimation through telephone from Engineer-in-charge failing which recovery of Rs. 10000.00 per hour shall be recovered from the contractors dues w.e.f the time immediately after the expiry of 24 hours duration. (ii) For the purpose of payment one unit of “Each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch, irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii.) Joints, jointing materials and cable required shall be measured and paid for separately 1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
357.00Attending, Repairing/restoring of electric power supply in the CQAE (WE) area, after identifying fault in HT 11 KV or LT 415 volt system, RMU,VCB, LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size, complete all as specified and directed. 50.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
358.00Note :- (i) The above work also include checking, detection and rectifcation of LT/HT UG Cable faults at CQAE (WE) Area as and when directed by Engineer-in-Charge/ JE (E/M).2Construction of chamber for 100mm sluices valveitem310Nos
359.00(ii) Hiring of cable fault detector to detect exact location of HT/LT UG cable fault deemed to be inclusive of unit quoted rate.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
360.00(iii) Major items required to be replaced/repaired shall be measured under relevant items of schedule/ BOQ.1.02Construction of chamber for 100mm sluice platesitem2213Nos
361.00(iv) Excavation and earth work if required shall be measured separately.2Construction of chamber for 100mm sluices valveitem310Nos
362.00(v) compliants will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x7 Days).2Construction of chamber for 100mm sluices valveitem310Nos
363.00(vi) In case of minor defect, entire job shall be completed within 02 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 300 /- per hours shall be recovered from the contractor.1.02Construction of chamber for 100mm sluice platesitem2213Nos
364.00(vii) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost shall be paid for the same. 3Supplying, Conveying and fixing spls. Including eaitem410Nos
365.00(viii) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs.500/- per hours shall be deducted from the dues of the contractor.2Construction of chamber for 100mm sluices valveitem310Nos
366.00(ix) Note that penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer in this regard shall be final and binding. 1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
367.00Supply and fix 4 Pole MCCB, 415 volts, fixed type, 250 Amp, 50 Hz, with rupturing capacity 25 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder pillar box including connecting lugs with busbar and mounting arrengments i.e screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed. Make : Indo Asian/L&T/Havells 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
368.00Supply, installation, testing and commissioning LT Feeder pillar box CPRI Tested of Size 800x600X450 mm suitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet of outdoor of panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 600 Amp and including PCC foundation as per site requairment to accomodated to the following :- INCOMING (a) MCCB 4 pole 250 Amp 36 KA - 01 No. (b) LED indicating lamp R-Y-B - 03 Nos. (c) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No OUTGOING (a) Through Bus Bar1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
369.00Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compart mentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one no of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any cap and description and reconnnecting existing LT UG Cable with new panel board all as directed :- 1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
370.00(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amp, 36 KA - 01 No (Incomer). (b) On Load Change over front operated of capacity 200 Amp, 4 Pole, 415 V - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 25 KA - 02 Nos. (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 03 Nos. (e) MCB TPN, 415 V of capacity 40 Amps, 10 KA - 01 No. (f) MCB SPN, 240 V of capacity 40 Amps, 10 KA - 03 Nos. (g) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (h) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (j) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
371.00Material and labour for Testing of earth resistance value from earthing pit test terminal point and write in/ on existing identification board complete all as specified and as directed. Around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip comprising of the following process :-720.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
372.00The following items are deemed to be inclusive of quoted rate :- (i) The above job shall be carried out by a trained technician having ITI in electrical and well known regarding earthing test. Documantary proof of the education of tradesman shall be produced by the contractor to the Engr-in-charge, before commencement of work.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
373.00(ii) The aforsesaid test will be carried out in presence of user and MES represnetative.1.02Construction of chamber for 100mm sluice platesitem2213Nos
374.00(iii) Two Party (consisting 2 x 1 No. Technician with 2 x 1 No. Helper) will report every Morning at 9 AM to JE E/M for Daily earth testing.2Construction of chamber for 100mm sluices valveitem310Nos
375.00(iv) Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from Authorised Company/ Lab).3Supplying, Conveying and fixing spls. Including eaitem410Nos
376.00(v) Contractor will be responsible for pouring of water in the Earth Pits Weekly at their own arrangement with Water Tanker, etc. (water will be provided by the contractor at his own arrangement and nothing extra will be admissible).
377.00(vi) Contractor will be responsible for marking of Earth check date and due date on existing Plate with synthetic enamel paint as specified by Engineer-in-Charge.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
378.00(vii) Contractor will be responsible for cleaning of bushes and grass all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip.2Construction of chamber for 100mm sluices valveitem310Nos
379.00Supply only charcoal dust/Breeze in trenches to improve the ER value of existing earth pits, complete all as specified and as directed.325.00KgExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
380.00Supply only common salt commercial in trenches to improve the ER value of existing earth pits, complete all as specified and as directed.450.00KgsExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
381.00Material and labour for magnesium sulphate (MgSO4) for improvement of earthing resistivity, complete all as specified and directed. 300.00KgsExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
382.00Material and labour for Powder Earthing Backfill Compound, Grade Standard for improvement of earthing resistivity and to increase the absorption of moisture around the earthing electrode, complete all as specified and directed.500.00KgsExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
383.00Supply and fixing in repair 40 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches/or levid in floor etc, complete all as specified anfd directed .80.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
384.00Supply and fixing in repair 20 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors etc, complete all as specified and directed.100.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
385.00Supply and Fix in repairs Bib Tap of 15 mm dia standard of PTMT any colour high pressure screwed for iron pipe (Minimum weight 90 gms ), complete all as specifed and directed. 20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
386.00Taking downn unsv funnel of any type and size Supply and fixing in repair GI funnels for earthing, complete all as specified and as directed.35.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
387.00Taking down existing GI earthstrip 25x3mm thick as earthing lead with its accessories and re fixing to wall/roofs etc. drawn in conduit/GI pipe etc all as specified and directed. Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.140.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
388.00Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal. head screw, complete all as specified and directed.35.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
389.00Supply and fixing in replacement of aluminium strip 25x3mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut and bolt, gutties, screws etc, complete all as speified & directed.150.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
390.00S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.300.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
391.00Material and labour for Brazing of copper/Aluminium for continuity, complete all as specified and as directed.140.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
392.00Material and labour in repairs Galvanised iron Earth strip of size 32 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed. 100.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
393.00Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mmx25mmx3mm of 450 mm long to be fixed to ground by means with necessary cement concrete and painting with two coats of synthetic enamel paint over a coat of red oxide primer, writing earth reading and connected items like painting of panel etc, and necessary excavation and earth work including taking down old, complete all as specified and as directed.40.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
394.00Repairing and maintenance of old existing earth pit by taking out carefully earth plate, watering pipe, earth lead protection pipe and re-buried the same after removing sludge from the plate & pipes including re-connection/brazing the plate and strip, whichever is required at site (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level,complete all as specified and directed including PCC 1:3:6 type C1 using 20mm graded stone aggregate for pit with cover of RCC 1:2:4 type B1 using 20mm graded aggregate, reinforced with welded steel wire fabric not less than 4 kg per Sqmtr with handle and angle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI mesh,filling with mixture of common salt and charcoal,necessary excavation, refilling, removing away soil and earth work in any type of soil including test point, testing and commissioning, complete all as specifed and as directed. Note : GI Funnel, brazing, mixture of salt/char coal/MgSO4 shall be measured and paid separately under releavant items.32.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
395.00Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.. Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global72.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
396.00The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
397.00(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.1.02Construction of chamber for 100mm sluice platesitem2213Nos
398.00(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate. 1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
399.00(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
400.00(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
401.00(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). 2Construction of chamber for 100mm sluices valveitem310Nos
402.00(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned. 1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
403.00(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab. 2Construction of chamber for 100mm sluices valveitem310Nos
404.00(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.2Construction of chamber for 100mm sluices valveitem310Nos
405.00(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. 3Supplying, Conveying and fixing spls. Including eaitem410Nos
406.00(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
407.00(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. 1.02Construction of chamber for 100mm sluice platesitem2213Nos
408.00(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. 1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
409.00(xiv) The electrode shall carry manufacturer's name . 1.02Construction of chamber for 100mm sluice platesitem2213Nos
410.00(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. 3Supplying, Conveying and fixing spls. Including eaitem410Nos
411.00(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.2Construction of chamber for 100mm sluices valveitem310Nos
412.00(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil. 1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
413.00(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. 1.02Construction of chamber for 100mm sluice platesitem2213Nos
414.00(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. 2Construction of chamber for 100mm sluices valveitem310Nos
415.00Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old one complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global72.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
416.00Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize lemp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and remove from site reconnecting existing LT UG Cable with new panel board, complete all as specified and directed and comprising of the following:- 1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
417.00(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 16 KA - 03 Nos. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 2Construction of chamber for 100mm sluices valveitem310Nos
418.00Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one N0. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :- 1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
419.00(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 25 KA - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amp, 16 KA - 05 Nos. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). 1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
420.00Note :- An amount of Rs 2,10,026.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum. 3Supplying, Conveying and fixing spls. Including eaitem410Nos
Total in Figures0.00INR Zero Only4Construction of chamber for 100mm sluice platesitem510Nos
Quoted Rate in FiguresSelect0.00000.0000 Zero Only