Bidhelp
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE SWC AND CE JAIPUR JAIPUR - MES||CWE JAIPUR - MES||GE (U) JAIPUR - MES
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE SWC AND CE JAIPUR JAIPUR - MES||CWE JAIPUR - MES||GE (U) JAIPUR - MES
GE (S) Jaipur
Rajasthan QTY :

Items - PROVN OF HARDSTANDING AND PARKING AREA NEAR ENVT PARK AND TRG AREA UNDER GE(S) JAIPUR AT MIL STN JAIPUR

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver3.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority : GE (S) JAIPUR
NAME OF WORK : PROVN OF HARDSTANDING AND PARKING AREA NEAR ENVT PARK AND TRG AREA UNDER GE(S) JAIPUR AT MIL STN JAIPUR
Contract No: GE(S)/J- OF 2025-26 (8414/E8)
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With TaxesTOTAL AMOUNT In Words (UV06661)NAME OF WORK : PROVN OF HARDSTANDING AND PARKING AREA NEAR ENVT PARK AND TRG AREA UNDER GE(S) JAIPUR AT MIL STN JAIPURContract No: GE(S)/J- OF 2025-26 (8414/E8)1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed.171CUM2Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.0 m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan in soft/loose soil etc complete all as specified and directed0.8CUM3Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed42CUM4Surface dressing not exceeding 15 cm deep in soft / loose soil complete all as specified and directed2000SQM5M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid.16CUM6Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed.130CUM7M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.170CUM8M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.15CUM9M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work complete all as specified and directed.0.6CUM10M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed.3.2CUM11M&L for forming fair finished drain or channel, 50 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and directed.140RM12M&L brick work using old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.39CUM13M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed.1.8PER 1000 NOS14S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed.4160KG15M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.2000SQM16M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed74SQM17M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.85SQM18M&L for GI pipe bracket, double swan / straight neck shape, suitable to fix on top of tubular pole of 40 mm bore complete all as specified and directed.7EACH19S&F galvanised tube of 40 mm bore, light grade with all fitting complete all as specified and directed.7RM20S&F steel tubular swaged pole 410 SP 31 (9 meters long) complete with cast iron base plate, finial, taper plug, nuts, bolts and washers all as specified including painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing complete embedded portion will be painted with two coat of black bituminous paint complete all as specified and directed. Note : Excavation, earthwork & PCC in foundation and coping shall be measured and paid seperately.7EACH21M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core complete all as specified and directed. Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.95RM22M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified and directed. Note:- Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.220RM23S&F LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.7EACH24M&L for earthing with galvanised iron earth plate electrode 600mm x 600 mm & 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below Ground level, connected to GI strip 32x6 mm (up to 7.5 metre) by means of GI nuts, bolts & washers , earth strip protected with & including 40 mm dia light grade GI pipe (up to 7.5 metre) all as shown in electrical plate No 3 of MES Schedule Part I, with & including PCC 1:3:6 type C1 for pit with cover of 50 mm thick RCC 1:1.5:3 type A1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, watering arrangements with 20 mm GI medium grade pipe , GI funnel with GI mesh, filling with common salt & charcoal in alternate layers, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as specified and directed. Note :- 1. The insulation procedure shall be followed as per instruction of the earth electrode manufacturer. 2. GI pipe of suitable size for protection against mechanical damage of main earth strip from earth electrode to test point up to 7.5 metre to be provided. The cost for the same shall be deemed to be included in the quoted rate. GI strip & GI protection pipe beyond 7.5 metre shall be measured & paid separately. 3. If desired earth resistance is not obtained during testing ,the earthing shall be re-done with out any extra cost.3EACH JOB25S&F in repair Junction box, size 260x210x116 mm, thermoplastic polystyrene unbreakable suitable for pole mounted outdoor type IP-65 insulated complete with FI clamps & nuts, bolts, washers and including terminal block heavy duty with phase seperators between R,Y,B terminals, including one MCB SP 06 amp 10 kA, all duly fixed on din channel, cable glands for cable entry complete all as specified and directed.7EACH26S&F heavy duty PVC insulated aluminium conductor of size 04 Sqmm 03 core, ISI marked, 1100 Volts grade drawn through steel pole from junction box to street light fitting complete all as specified and directed.100RM27Supply, install, testing and commissioning of factory made (CPRI type test certified) LT feeder pillar box out door type, floor mounted, compartmentalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system having bus bar chamber with insulated copper bus bars installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet, powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement and with base frame of 40x40x05 mm angle iron including following: Incoming: (a) MCCB 40 amps, 4 pole, 25 KA with adjustable thermal magnetic release, 50 Hz, 415 volts grade - 01 No. (b) Digital volt and ammeter with selector switch and CT's set - 01 Set (c) LED indicating lamps (R, Y & B) - 01 Set. (d) Earth fault module (e) Bus bar electrolytic grade copper and supported on non-hygroscopic, non-carbonising, corrosion resistance SMC insulators 200 Amp, 4 pole, not less than 60 cm long mounted on insulators for outgoing supply. Outgoing: (a) MCB TPN 25 amps, 4 pole, 18 KA with adjustable thermal magnetic release, 50 Hz, 415 volts grade - 03 No. (b) Timer switch three phase - 01 No.1EACH JOB28Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.10CUM29Demolition of cement concrete un-reinforced in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.4.5CUM85965110660(UV06661)
(01)(02)(03)(03)(04)(06)(07)(08)(09)(10)(11)(12)(05)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40)(41)(42)(43)(44)(45)(46)(47)(48)(49)(50)(51)(52)(06)(54)(07)1009
1.00Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed.171.00CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyExcavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed. 22526911
2.00Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.0 m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan in soft/loose soil etc complete all as specified and directed0.80CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyExcavation in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.0 m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan in soft/loose soil etc complete all as specified and directed 23794331
3.00Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed42.00CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyReturning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed 15986331
4.00Surface dressing not exceeding 15 cm deep in soft / loose soil complete all as specified and directed2000.00SQMExcess(+)1Full ConversionINR0.000.00INR Zero OnlySurface dressing not exceeding 15 cm deep in soft / loose soil complete all as specified and directed 9287651
5.00M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid.16.00CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid. 17443679
6.00Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed.130.00CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyRemoval of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. 17185409
7.00M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.170.00CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. 12719281
8.00M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.15.00CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. 11802871
9.00M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work complete all as specified and directed.0.60CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work complete all as specified and directed. 20070563
10.00M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed.3.20CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed. 23785541
11.00M&L for forming fair finished drain or channel, 50 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and directed.140.00RMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for forming fair finished drain or channel, 50 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and directed. 17987481
12.00M&L brick work using old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.39.00CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L brick work using old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. 14761731
13.00M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed.1.80PER 1000 NOSExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed. 22935963
14.00S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed.4160.00KGExcess(+)1Full ConversionINR0.000.00INR Zero OnlyS&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed. 22551259
15.00M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.2000.00SQMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. 67629961
16.00M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed74.00SQMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed 17874711
17.00M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.85.00SQMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 21740303
18.00M&L for GI pipe bracket, double swan / straight neck shape, suitable to fix on top of tubular pole of 40 mm bore complete all as specified and directed.7.00EACHExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for GI pipe bracket, double swan / straight neck shape, suitable to fix on top of tubular pole of 40 mm bore complete all as specified and directed. 13606339
19.00S&F galvanised tube of 40 mm bore, light grade with all fitting complete all as specified and directed.7.00RMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyS&F galvanised tube of 40 mm bore, light grade with all fitting complete all as specified and directed. 9306771
20.00S&F steel tubular swaged pole 410 SP 31 (9 meters long) complete with cast iron base plate, finial, taper plug, nuts, bolts and washers all as specified including painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing complete embedded portion will be painted with two coat of black bituminous paint complete all as specified and directed. Note : Excavation, earthwork & PCC in foundation and coping shall be measured and paid seperately.7.00EACHExcess(+)1Full ConversionINR0.000.00INR Zero OnlyS&F steel tubular swaged pole 410 SP 31 (9 meters long) complete with cast iron base plate, finial, taper plug, nuts, bolts and washers all as specified including painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing complete embedded portion will be painted with two coat of black bituminous paint complete all as specified and directed. Note : Excavation, earthwork & PCC in foundation and coping shall be measured and paid seperately. 48441341
21.00M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core complete all as specified and directed. Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.95.00RMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core complete all as specified and directed. Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately. 25415973
22.00M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified and directed. Note:- Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.220.00RMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified and directed. Note:- Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately. 25513743
23.00S&F LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.7.00EACHExcess(+)1Full ConversionINR0.000.00INR Zero OnlyS&F LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. 29091539
24.00M&L for earthing with galvanised iron earth plate electrode 600mm x 600 mm & 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below Ground level, connected to GI strip 32x6 mm (up to 7.5 metre) by means of GI nuts, bolts & washers , earth strip protected with & including 40 mm dia light grade GI pipe (up to 7.5 metre) all as shown in electrical plate No 3 of MES Schedule Part I, with & including PCC 1:3:6 type C1 for pit with cover of 50 mm thick RCC 1:1.5:3 type A1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, watering arrangements with 20 mm GI medium grade pipe , GI funnel with GI mesh, filling with common salt & charcoal in alternate layers, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as specified and directed. Note :- 1. The insulation procedure shall be followed as per instruction of the earth electrode manufacturer. 2. GI pipe of suitable size for protection against mechanical damage of main earth strip from earth electrode to test point up to 7.5 metre to be provided. The cost for the same shall be deemed to be included in the quoted rate. GI strip & GI protection pipe beyond 7.5 metre shall be measured & paid separately. 3. If desired earth resistance is not obtained during testing ,the earthing shall be re-done with out any extra cost.3.00EACH JOBExcess(+)1Full ConversionINR0.000.00INR Zero OnlyM&L for earthing with galvanised iron earth plate electrode 600mm x 600 mm & 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below Ground level, connected to GI strip 32x6 mm (up to 7.5 metre) by means of GI nuts, bolts & washers , earth strip protected with & including 40 mm dia light grade GI pipe (up to 7.5 metre) all as shown in electrical plate No 3 of MES Schedule Part I, with & including PCC 1:3:6 type C1 for pit with cover of 50 mm thick RCC 1:1.5:3 type A1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, watering arrangements with 20 mm GI medium grade pipe , GI funnel with GI mesh, filling with common salt & charcoal in alternate layers, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as specified and directed. Note :- 1. The insulation procedure shall be followed as per instruction of the earth electrode manufacturer. 2. GI pipe of suitable size for protection against mechanical damage of main earth strip from earth electrode to test point up to 7.5 metre to be provided. The cost for the same shall be deemed to be included in the quoted rate. GI strip & GI protection pipe beyond 7.5 metre shall be measured & paid separately. 3. If desired earth resistance is not obtained during testing ,the earthing shall be re-done with out any extra cost. 130949760
25.00S&F in repair Junction box, size 260x210x116 mm, thermoplastic polystyrene unbreakable suitable for pole mounted outdoor type IP-65 insulated complete with FI clamps & nuts, bolts, washers and including terminal block heavy duty with phase seperators between R,Y,B terminals, including one MCB SP 06 amp 10 kA, all duly fixed on din channel, cable glands for cable entry complete all as specified and directed.7.00EACHExcess(+)1Full ConversionINR0.000.00INR Zero OnlyS&F in repair Junction box, size 260x210x116 mm, thermoplastic polystyrene unbreakable suitable for pole mounted outdoor type IP-65 insulated complete with FI clamps & nuts, bolts, washers and including terminal block heavy duty with phase seperators between R,Y,B terminals, including one MCB SP 06 amp 10 kA, all duly fixed on din channel, cable glands for cable entry complete all as specified and directed. 37189299
26.00S&F heavy duty PVC insulated aluminium conductor of size 04 Sqmm 03 core, ISI marked, 1100 Volts grade drawn through steel pole from junction box to street light fitting complete all as specified and directed.100.00RMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyS&F heavy duty PVC insulated aluminium conductor of size 04 Sqmm 03 core, ISI marked, 1100 Volts grade drawn through steel pole from junction box to street light fitting complete all as specified and directed. 18939511
27.00Supply, install, testing and commissioning of factory made (CPRI type test certified) LT feeder pillar box out door type, floor mounted, compartmentalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system having bus bar chamber with insulated copper bus bars installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet, powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement and with base frame of 40x40x05 mm angle iron including following: Incoming: (a) MCCB 40 amps, 4 pole, 25 KA with adjustable thermal magnetic release, 50 Hz, 415 volts grade - 01 No. (b) Digital volt and ammeter with selector switch and CT's set - 01 Set (c) LED indicating lamps (R, Y & B) - 01 Set. (d) Earth fault module (e) Bus bar electrolytic grade copper and supported on non-hygroscopic, non-carbonising, corrosion resistance SMC insulators 200 Amp, 4 pole, not less than 60 cm long mounted on insulators for outgoing supply. Outgoing: (a) MCB TPN 25 amps, 4 pole, 18 KA with adjustable thermal magnetic release, 50 Hz, 415 volts grade - 03 No. (b) Timer switch three phase - 01 No.1.00EACH JOBExcess(+)1Full ConversionINR0.000.00INR Zero OnlySupply, install, testing and commissioning of factory made (CPRI type test certified) LT feeder pillar box out door type, floor mounted, compartmentalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system having bus bar chamber with insulated copper bus bars installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet, powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement and with base frame of 40x40x05 mm angle iron including following: Incoming: (a) MCCB 40 amps, 4 pole, 25 KA with adjustable thermal magnetic release, 50 Hz, 415 volts grade - 01 No. (b) Digital volt and ammeter with selector switch and CT's set - 01 Set (c) LED indicating lamps (R, Y & B) - 01 Set. (d) Earth fault module (e) Bus bar electrolytic grade copper and supported on non-hygroscopic, non-carbonising, corrosion resistance SMC insulators 200 Amp, 4 pole, not less than 60 cm long mounted on insulators for outgoing supply. Outgoing: (a) MCB TPN 25 amps, 4 pole, 18 KA with adjustable thermal magnetic release, 50 Hz, 415 volts grade - 03 No. (b) Timer switch three phase - 01 No. 104568120
28.00Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.10.00CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyDemolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 14597531
29.00Demolition of cement concrete un-reinforced in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.4.50CUMExcess(+)1Full ConversionINR0.000.00INR Zero OnlyDemolition of cement concrete un-reinforced in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. 15439971
Total in Figures0.00
Quoted Rate in FiguresSelect0.00000.0000 Zero Only
Quoted Rate in WordsINR Zero Only