Bidhelp
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE SWC AND CE BATHINDA ZONE - MES
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE SWC AND CE BATHINDA ZONE - MES
Chief Engineer Bathinda Zone
Rajasthan QTY :

Items - PROVN OF OTM ACCN FOR ARMD REGT (PHASE-I OF TWO PHASES) AT BIKANER MIL STN (JOB NO SW/223)

Tender Details
Costs
Documents
BOQ

BoQ1

" BOQ "
BoQ_Ver3.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority : CE BATHINDA ZONE
Name of Work: PROVN OF OTM ACCN FOR ARMD REGT (PHASE-I OF TWO PHASES) AT BIKANER MIL STN (JOB NO: SW/223)
Contract No: CE BTZ/BKN/TOKEN-35 OF 2025-26
Bidder Name :
GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
Sl. No.Description of Parts/ ItemItem Code / MakeNo. or Qty.UnitPre Priced Rate (in. Rs.) as Defined by MESAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With TaxesTOTAL AMOUNT In WordsRepresent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES
123345789101112614151617181920212223242526272829303132333435363738394041424344454647484950515275488
0NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
1.0000Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I(Ref pre-priced schedule attached separately)14000701.00Lump Sum 339,169,500.00 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
2.0000Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately)15000531.00Lump Sum 3,657,117.83 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
3.0000Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately)16000571.00Lump Sum 586,856.80 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
4.0000Lump sum price worked out by the tenderer for ROAD, PATH, HARD STANDING AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately)17000281.00Lump Sum 66,991,332.03 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
5.0000Lump sum price worked out by the tenderer for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately)18000301.00Lump Sum 7,220,239.70 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
6.0000Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately)19000771.00Lump Sum 1,524,973.02 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
7.0000Lump sum price worked out by the tenderer for SECURITY WALL, FENCING AND GATE WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately)20000011.00Lump Sum 22,401,705.53 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
8.0000Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately)21000761.00Lump Sum 1,477,660.54 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
9.0000Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION, LIGHTENING PROTECTION, DG SET AND HIGHMAST LIGHT as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately)22000811.00Lump Sum 5,882,242.17 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
10.0000Lump sum price worked out by the tenderer for SUMMER COOLING APPLIANCES, AIR CONDITIONING AND HOT WATER SUPPLY as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately)23000701.00Lump Sum 1,635,396.00 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
11.0000Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately)24000041.00Lump Sum 11,203,886.03 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
12.0000Lump sum price worked out by the tenderer for DEMOLITION AND DISMANTLING as listed in Schedule ‘A’ Part-XII(Ref pre-priced schedule attached separately)25000411.00Lump Sum 2,215,527.77 Excess(+)1Full ConversionINR0.000.00INR Zero Only-100.000
13Schedule 'A' Part-XIII(FURNITURE)
13.0010Bath Mat (PVC) as per drawing No. FD/E6/MAP/07 sheet No. 1/19607AA13.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyTP
13.0020Black board with easel and pointer (steel) as per drawing No. FD-1041 sheet No. 1/1P1041E2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel, Pr-FD-71(M)
13.0030Book case as per drawing No. FD-237 sheet No. 1/1P0237A1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWoodenPr-FD-45(M)
13.0040Book case open (Small) as per drawing No. FD-355 sheet No. 1/1P0355A1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0050Book case (steel) as per drawing No. FD-1028 sheet No. 1/191028B10.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteelPr-FD-90(M)
13.0060Chair CB'A' special with hand rest as per drawing No. FD-120(M) sheet No. 1/1P0120B50.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteelPr-WDB-1908,DB-4134,FD-120,FD-120(M)
13.0070Chair dining with long back as per drawing No. FD-357 sheet No. 1/1P0357A20.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0080Chair Writing as per drawing No. FD/E6/MAP/12 sheet No. 1/19612AB130.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel
13.0090Chair writing steel as per drawing No. FD-360 sheet No. 1/190360A2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel
13.0100Desk Stand Lecture (steel) as per drawing No. FD-1022 sheet No. 1/191022B1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel
13.0110Desk with Dias Wooden as per drawing No. FD-399 sheet Nos 1/2 and 2/2P0399A2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0120Hat stand as per drawing No. FD-233 sheet No. 1/1P0233A1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWoodenPr-FD-206(M)
13.0130Hot case large as per drawing No. FD-364 sheet No. 1/1P0364B3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0140Ladder aluminium as per drawing No. FD-1025 sheet No. 1/191025A1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel
13.0150Magazine rack medium as per drawing No. FD-365 sheet No. 1/1P0365B1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0160Meat safe (large) as per drawing No. FD-370 sheet No. 1/1P0370B1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0170Board notice (900 mm X 600 mm) as per drawing No. FD-1042 sheet No. 1/1P1042A2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWoodenPr-FD-117(M)
13.0180Pointer short 900 mm as per drawing No. FD-1041 sheet No. 1/191041C1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0190Pointer long 1525 mm as per drawing No. FD-1041 sheet No. 1/191041B3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0200Rack pigeon holes (steel) as per drawing No. FD-1037 sheet No. 1/191037B1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel
13.0210Rack six tiers (dimension as 1905 mm X 915 mm X 610 mm) (steel) as per drawing No. FD-1038 sheet No. 1/191038B3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel, Pr-FD-106(M)
13.0220Receptacle as per drawing No. FD/E6/MAP/13 sheet No. 1/19613AA19.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyTP
13.0230Receptacle (large) with bucket as per drawing NO. FD-1044 sheet No. 1/191044A1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel, Pr-FD-82(M)
13.0240Meat safe (small) as per drawing No. FD-369 sheet No. 1/190369B2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0250Meat Safe (large) as per drawing No. FD-407 sheet No. 1/1P0407B2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0260Side Board as per drawing No. FD-241 sheet No. 1/1P0241C1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0270Side rack with tray four spaces (steel) as per FD-1023 Sheet No. 1/191023B49.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteelPr-FD-97(M)
13.0280Sofa set to seat 3 as per drawing No FD-373 sheet Nos 1/2 & 2/2P0373G2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0290Stool dressing as per drawing No. FD/E6/MAP/14 sheet No 1/1P614AA2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0300Table marble top (1830 mm X 900 mm X 760 mm) as per drawing No. FD-298 sheet No. 1/1P0298B1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0310Table lapper (steel) as per drawing No. FD-1018 sheet No. 1/1P1018A15.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteelPr-FD-294(M)
13.0320Table with drawer (900 mm X 600 mm X 760 mm) (steel) as per drawing No. FD-1008 sheet Nos 1/2 & 2/291008B17.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel, Pr-FD-310(M), FD-283(M)
13.0330Table card (900 mm X 900 mm X 760 mm) as per drawing No. FD-352 sheet No. 1/1P0352C1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWoodenPr-FD-91(M)
13.0340Table centre as per drawing No. FD-393 sheet No. 1/1P0393A14.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0350Table Computer as per drawing No. FD/E6/MAP/03 sheet No. 1/19603AB4.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel
13.0360Table cook (steel) as per drawing No. FD-1019 sheet No. 1/191019B4.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel
13.0370Table dining for eight persons (1800 mm X 900 mm X 760 mm) as per drawing No. FD-273 sheet Nos 1/2 & 2/2P0273I4.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWoodenPr-FD-239(M)
13.0380Table dining for six persons (1500 mm X 900 mm X 760 mm) as per drawing No. FD-273 sheet Nos 1/2 & 2/2P0273J2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0390Dressing Table including Stool as per drawing No. FD/MAP-II/07 sheet Nos 1/2 & 2/2P207AE9.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWooden
13.0400Table conference/ library (steel) as per drawing No. FD-1001 sheet Nos 1/2 & 2/291001C1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel
13.0410Table clerks (steel) as per drawing No. FD-1004 sheet No. 1/191004B40.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel, Pr-FD-84(M), FD-307(M)
13.0420Table officers (steel) as per drawing No. FD-1003 sheet Nos 1/2 & 2/291003B24.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel, Pr-FD-84(M)
13.0430Table pantry (steel) as per drawing No. FD-1020 sheet No. 1/191020B2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel
13.0440TV/VCR TABLE as per drawing No. HFD/ 2043 sheet No 1/19H20431.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
13.0450Teapoy as per drawing No. FD-278 sheet No. 1/1P0278C3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyWoodenPr-FD-232(M)
13.0460Teapoy Verandah as per drawing No. FD/E6/MAP/17 sheet No. 1/19617AC3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel
13.0470Trestle store room (steel) as per drawing No. FD-1043 sheet No. 1/191043B6.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteel, Pr-FD-86(M)
13.0480Work bench workshop (1800 mm X 900 mm X 760 mm) (steel) as per drawing No. FD-1024 sheet No. 1/1P1024D14.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteelPr-FD-301(M)
13.0490Bar stool of Frame Material: Stainless Steel, Seat Material: Leather, Color as approved, Padestal Base: Glass Fibre Nylon, Padestal Base Type : Without Wheels, Arm and foot rest included, Type Of Adjustment: With Hydraulic, Height Adjustment: 120 mm, Overall Chair Height: ( Minimum) 1250 mm, Seat Height: (Minimum) 850 mm, Seat Size: 450 mm X 405 mm, Density Of Polyurethane Foam Used In Seat: 40 Kg/Cum, Thickness Of Polyurethane Foam Used In Seat: 50 mm, Material Of Fabric Of Seat Cover : Leatherite, Rotatable: Yes as per Model No. GC-991 of Geeken or equivalent of Methodex, MHB, Godrej9T069V5.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyTP
13.0500Extendable Conference Table for 20 persons as per Model No Encarta of Godej Interio or equivalent of Nilkamal or Durian9T105T1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
13.0510Stool revolving (adjustable) (steel) as per drawing No. FD-1026 sheet No. 1/191026B41.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySteelPr-FD-103(M)
13.0520Board Notice/Display Board of size (1800mm X 1200mm) of Make:- Alkosign, Model No:- ARTW 120180 or other equilent make as approved by the GE9T069D29.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyTP
13.0530Drugget of variety No. Wollen, 60 tex X 12 warp, size 3000 mm X 2000 mm as per IS 697: 20059T026B1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyTP
13.0540Chair Multiseater as per drawing No. HFD/ 20729H20724.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
13.0550Executive chair revolving of Make:- Godrej, Model No:- ELITE0001 or equivalent of Methodex, Geeken as approved by the GE9T104T2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyTP
13.0560Chair CBA Special with Hand Rest of Make:- Methodex, Model No:- CL-01/ Geeken, Model No:- GST-801/Godrej as approved by the GE9T069J157.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyTP
13.0570Chair CB steel with arms cushion of Make:- Methodex, Model No:- TCC-2/Godrej/Geeken as approved by the GE9T069I27.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
13.0580Rack Rifles for 20 Rifles (INSAS) of Make:- Kaypee & Co or other equilent make as approved by the GE9T069P12.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlyTP
13.0590Rack Rifles for Carbine Machine 20 Rifles of Make:- Kaypee & Co or other equilent make as approved by the GE9T069Q6.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14Schedule 'A' Part-XIV(ARBORICULTURE)
14.0010M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Canerydate Palm plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc.ARB90250.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0020M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of plumeria plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc.ARB90540.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0030M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of flower plant (e.g. rose, marigold rose, ticoma, motia chandni, vinca, etc.) of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc.ARB90636.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0040M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Azadirachta indica ( Neem ) plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc.ARB90165.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0050M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Gulmohar plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc.ARB90330.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0060M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Ashoka Regional of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc.ARB90830.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0070M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Pongamia pinnata ( Karanja ) plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc.ARB92165.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0080Complete maintenance after physical completion of plants/Hedge/grass by weeding hosing, saucer making once in every week for plants/Hedge once in every 10 days for carpet grass/country grass/doob grass, burmuda grass, prunning dried branches once in every week, depositing the material at place as directed by Engr-In-Charge and planting the new plants in place of dead plants of same species and height tuning with dods wherever required by replacing the dead patches of grass with the same grass as required without extra cost to the deptt and all as directed by Engr-In-Charge. Note:(i) Manure and pesticide required for maintenance of plant under this items shall be arranged by the contractor at his own cost and rate of the same shall be deemed to be included in the unit rate quoted against this items (ii) Scope of maintenance shall be as specified in Ph-II. (iii) Work against this item will be commenced only after completion of plantation of trees, plantation of grass and plantation of hedge & shrubbery.I8448412.00Each Calender month - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0090LAWN: Excavation to a depth of 0.30 m removing all foreign bodies over 50 mm dia, filling in the same with the excavated earth (after removal of rubbish) mixed with manure in the ratio of 3:1 by volume (3 part of stacked volume of earth after reduction by 20% and 1 part of stacked volume of manure after reduction by 10%), as indicated on grading plans. All finished areas shall slope to drain. Where no grades are shown, the areas shall have a smooth a continual grade between existing or fixed controls (such as walsk, curbs catch basins, elevations at steps or buildings) and levels shown on plans, roll scarify, rake and level as necessary to obtain true, even grassing surfaces. All finished grades shall meet approval of the GE before grassing is done. Dribbling of doob grass according to site at a spacing of 5 cm apart grassing with specified grass including watering and maintenance of lawn till the grass forms properly. The grass shall be free of weeds and fit for moving including mandatory maintenance of lawn for 6(Six) months complete all as specified and directed by Engineer-in-Charge. Note: - (i) Cost of dhub/doob grass is included in unit rate of this item. However, manure etc. as required shall be measured & paid for separately. (ii) Manure & pesticide required for maintenance of plants during maintenance period shall be arranged by the contractor at his own cost and rates of the same shall be deemed to be included in the quoted rates.ARB0066040.00Sqm - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0100M & L for preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete all as specified and as directed. Note: Cost of sludge, manure or extra earth to be paid for separately.ARB516244.80Cum - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0110M& L for plantation of shrubs, hedge etc. at the site including watering and removal of unserviceable material including shrub/ hedge plants of any type and of height 60-75 cm in earthen pots of size 20 cm complete all as specified and as directed.ARB9071360.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
14.0120Supply and stacking of well decomposed Cow dung/ meegni manure including royalty, loading, unloading, transportation and stacking etc. at site. Note:- For the purpose of payment the stack measurement shall be reduced by 10% for voids.( 338 Cum for Lawns and 49 Cum for trees and shrubs)ARB00230.00Cum - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15Schedule 'A' Part-XV(MISCELLANEOUS PARTS)
15.0010Taking down stop cock, bib tap, stop valve etc. complete all as specified and as directed.844592166.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0020Taking down existing old fluorescent tube light fittings/ bulk head light fittings/ ceiling light fittings/ building light fittings including lamp any capacity, any type complete all as specified and as directed.19801X236.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0030Taking down main switch/MCB/MCCB/MCB DB/ MCCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.19304C41.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0040Taking down old unserviceable submain wiring (concealed or surface) 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number excluding batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface to match the existing surface complete all as specified and as directed.19508I2500.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0050Taking down old unserviceable earthing any type and removing to MES store yard or taken on schedule of credit complete all as specified and as directed.84486A4.00Each Job - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0060Taking down old existing electrical meter of any rating and capacity complete all as specified and as directed.19737A1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0070Taking up or down old unserviceable GI pipe of any size fixed/ laid in any position, keeping serviceable materials separately for reuse at site or removing to store or taken on schedule of credit complete all as specified and as directed.18059G36.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0080Disconnecting, taking out old unserviceable service connection cable of rated voltage 1100 V, nominal cross sectional area of main conductor upto any size and upto 4 core, any type from trenches/ ducts/pole/wall including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit or for relaying complete all as specified and as directed.19181J343.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0090Taking down existing old unserviceable transformer of any type and size after disconnecting all incoming and outgoing electrical connections without any damage and safely depositing at AGE E/M store yard, SI lines complete all as specified and as directed.19936E2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0100Dismantling existing LT feeder pillar box/ LT panel board of any type and size including recovering serviceable items including making good disturbed surfaces complete all as specified and as directed.19829G3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0110Taking up or down 80 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.18059E50.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0120Taking down existing sluice valve or nonreturn valve of nominal size of 150 mm and removing to MES store yard or taken on schedule of credit complete all as specified and as directed.18608F1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0130Taking down existing sluice valve or nonreturn valve of nominal size of 100 mm and removing to MES store yard or taken on schedule of credit complete all as specified and as directed.18608D1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0140Taking down existing sluice valve or nonreturn valve of nominal size of 80 mm and removing to MES store yard or taken on schedule of credit complete all as specified and as directed.18608C1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0150Taking down existing gate valve any type and any size and removing to MES store yard or taken on schedule of credit complete all as specified and as directed.74018C38.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0160Dismantling of old unserviceable valve pit of any size and removing demolished material from site complete all as specified and as directed.H472602.00Each Job - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0170S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.18529E597.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0180S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 200, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.18529G597.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0190Supply and fix LLDPE Anaerobic Underground Septic Tank of capacity 2000 litres, 3 Nos of chambers, 2 Nos of manholes, made of rotation moulding application LLDPE materials having MFI ≥ 4.0, density ≥ 930 kg/m³, tensile stress at yield: ≥ 15 Mpa, tensile strain at yield: ≤ 25%, tensile strain at break: ≥ 80%, thickness of wall ≥ 10 mm including necessary inlet and outlet pipe of 2 metre length with submerged pipe tee, vent pipe of 2 metre length and 50 mm dia, designed to carry sewage and salvage water with upflow filter chamber including necessary excavation and earth works, footings of appropriate size and thickness in plain cement concrete works in cement concrete (M7.5) using 40 mm graded crushed stone aggregates complete all as specified and as directed.18376C2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0200Supply and fix punched tape concertina coil made out of cold drawn unalloyed steel wires of dia 2.6 mm having minimum tensile strength of 1670 N per sqmm as per IS 4454 (Part- 1): 2001 with hot dip galvanized as per practice recommended in IS: 2629 and the coatings shall conform to heavily coated hard variety as per table I of IS: 4826 (weight of Zinc coating 230 gram per sqm minimum) and steel strip of size 19 mm X 0.5 mm with hardness of 137 to 187 VPN and zinc coating of 18 to 20 microns, minimum 610 mm dia of coil when closed, (9 kg ± 5 %) weight of coil with 50 turns & 129 Nos clips (without handles and spikes) and minimum 580 mm dia when opened upto 6 metres, stretched to 6 metres for 50 turns during installations complete all as specified and as directed.10124A1093.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0210Supplying, laying, connecting, jointing and testing in trenches 200 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.18600E90.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0220Supplying, laying, connecting, jointing and testing in trenches 150 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.18600D490.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0230Supplying, laying, connecting, jointing and testing in trenches 100 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.18600B300.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0240M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.0) as per IS 14846: 2000 of preferred materials, nominal size 200 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.27034G1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0250M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.0) as per IS 14846: 2000 of preferred materials, nominal size 150 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.27034H1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0260M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.0) as per IS 14846: 2000 of preferred materials, nominal size 100 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.27034I1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0270M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.0) as per IS 14846: 2000 of preferred materials, nominal size 80 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.27034J2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0280S & F ductile iron air relief valve, type of single air valve – large orifice type (S 2), nominal size 50 mm, PN 1.6, flange end, conforming to IS 14845: 2000 complete all as specified and directed.18579D5.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0290Supplying, laying, connecting, jointing and testing in trenches ductile iron fittings (special castings) (class K12 as per IS 9523: 2000) for ductile iron pressure pipe for water mains upto 250 mm nominal dia (spigot and socket and flange ends (for push on joints and flanged joints) with external coatings of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 9523: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 for push on joints and rubber gasket as per IS 638: 1979 for flanged joints complete all as specified and as directed.18605A750.00Kg - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0300M & L boring holes under road pavement by bocky manually, in any type of soil upto 200 mm bore Complete all as specified and as directed.H4727280.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0310S & F in integrated type Heat Pump water heater with following components including installation testing and commissioning Outdoor Air cooled Integrated or split type Heat Pump with recirculation mode having minimum compressor capacity 3 HP, hermetically sealed with environment friendly refrigerant. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. The ratio of Rated output heating capacity to Rated Input Power should be such that COP of the machine is not less than 3.0 and must have Back-up heater power of not less than 12 kW and rated power input of not more than 2.5 kW. The heat pump shall have water storage tank of capacity (having internal glass lining) not less than 450 litre. NOTE: (a) Heat pump should have all the safety protections like high/low voltage, high temperature, refrigerant leak, compressor overheat protection with operational noise level not more than 60 dbA. (b) Heat pump should have a user friendly control panel to set the desired temperature with display of the actual temp also with flexibility of installing the same 15-30 m away from the heat pump.84461O2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0320Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 195 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed.19575B2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0330Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 310 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed.19575C1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0340Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 360 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed.19575D1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0350 Supply and fixing Hydrocyclone filter with 2 solid flange size of 75mm dia and capacity of 30 m³/hr for head control unit in drip irrigation system IS 14743:1999 with all connected accessories Complete all as specified and directed by Engineer-In-Charge. 84529A7.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0360Supply and Installation of Desert cooler of size 26 inch X 26 inch X 33 inch or next available higher size, electric driven single phase 230 volts GI sheet body having nominal air flow capacity of 4000 Cu M per hours, factory made GI sheet body 18 SWG and side panels of 22 SWG, water sump capacity not less than 120 litres, including water pump submersible type of suitable capacity ISI marked, complete including electric connection complete all as specified and as directed. Note (a) : Sufficient length of 3 core PVC sheathed round copper cable size 23/.0076 to enable fixing in to plug point shall be provided by contractor. (b) GI Pipes, float valve, stop valve, PVC connection shall be measured and paid separately under respective item. (c) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer. (d) Serial Number as issued by Engineer-in-Charge of cooler and GE Office name shall also be written on cooler with red colour permanent marker or paint, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account84461F181.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0370Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 1 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed.19989A14.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0380Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 2 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed.19989B15.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0390Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner cooling type both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, EER 3.2, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 1.5 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class 'O' Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8" for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 year for compressor, 5 year for condenser and PCB card after Installation and commissioning of complete unit. 84461H40.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0400Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner cooling type both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, EER 3.2, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 2 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class 'O' Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8" for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 years for compressor, 5 years for condenser and PCB card after Installation and commissioning of complete unit. 84461I11.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0410Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 5 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed.19989E51.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0420Supplying, installing, testing and commissioning outdoor type compact substation (CSS) having 11 kV, 630 Amps, internal arc fault for 20KA for 0.1sec as per IEC 61330/62271-200 and comprising as under: - (A) HT Section: 11 kV, 630 Amp, horizontal draw out VCB with motor operated spring charging mechanism with 24 V DC closing/ opening , shunt trip coil, auxiliary switch, mechanical on/ off push button, mechanical operating counter with metering, 01 No CT, PT, IDMT, cubical auxiliary relay, 08 window annunciator model No SI-801, battery power back with 07 AH battery and in built charger 24 V circuit. (B) Transformer section: Mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 500 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available. (C) LT Section: LT section comprising of LV Section incomer of MCCB rated current (In): 630 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 4 Nos (d) Danger Notice Plate for LT84477G1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0430Material and labour for laying of double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 140 mm, minimum inside dia 106 mm conforming to IS 16205 (Part 24) : 2017 including boring of holes by trenchless technology using ultra sounding technique and necessary machine including all fittings complete all as specified and as directed.BOR01D2355.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0440Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 1200 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 1200 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) Air Circuit Breaker (ACB) of rated current 800 A, Rated operational voltage 415 V, Rated insulation voltage 1000 V, 4 Pole, 50 Hz AC supply, Rated ultimate short circuit breaking capacity 50 kA, Rated service short circuit breaking capacity 50 kA, Rated short time withstand capacity 50 kA for 1 second, Rated making capacity 105 kA, Rated impulse withstand voltage of main circuit 8 kV, typical opening time 40 ms, typical closing time 60 ms, thermal magnetic release, manual draw out, overload protection, short circuit protection, earth fault protection – 1 No (D) Outgoing: (a) MCCB rated current (In): 200 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No LT002M1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0441Srl Item No 15.044 Continued...... (b) MCCB rated current (In): 400 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (c) MCCB rated current (In): 100 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (d) MCCB rated current (In): 63 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (e) MCCB rated current (In): 32 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (f) MCCB rated current (In): 20 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (g) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -6 Nos (E) Accessories: (a) Digital voltmeter 0-1000 V with selector switch – 1 No (b) Digital ammeter 0-1000 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 pole contactor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with 10 sqmm copper wiring, IP54 protection grade- 1 No
15.0442Srl Item No 15.044 Continued...... (G) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm
15.0450Designing, manufacturing, supplying, fixing, erecting, testing and commissioning LT APFC panel with capacitor bank, conforming to IS 16636: 2017, 245 kVAR, outdoor installations, rated system voltage of the panel 440 V ± 10%, rated frequency 50 Hz, 3 phase, 4 wire, delta connected, rated impulse withstand voltage 8 kV, free standing, pedestal mounted, made of cold rolled close annealed sheet of minimum 2 mm thick for the load bearing structure and minimum 1.6 mm thick for door and partition, 50⁰C ambient temperature, IP 54 Ingress Protection, 1000 Amp rated copper busbar, metallized polypropylene (MPP) dielectric type, resin filled box type, self-healing type, shunt capacitor as per IS 13340: 2012, switching configuration: 100 kVAR X 2 No + 50 kVAR X 1 Nos + 25 kVAR X 1 No + 10 kVAR X 1 Nos + 5 kVAR X 3 Nos (total seven steps), suitable protection in line with IEC and IS for overheating, over current, earth fault, over voltage, short circuit, thermal overload and over pressure, suitable size power and control cable as per Indian Standards, powder coated in grey colour, including microprocessor based automatic power factor correction controller with human machine interface, cooling fans, capacitor duty contactors, 7% detuned reactors, two earth terminals in the panel and as per the details mentioned below complete all as specified and as directed. and shall be including the followings: - (A) INCOMING: (i) MCCB rated current(In): 500A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, suitable for 415 V, 50 Hz AC supply – 1 No (ii) Microprocessor based automatic power factor correction controller (minimum 8 steps)- 1 No (iii) Cooling Fans to be provided for forced cooling (B) OUTGOING: (a) 19991J1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0451Srl Item No 15.045 Continued...... (i) 5 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 3 Nos (ii) MCCB rated current(In): 15A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 3 Nos (iii) 5 kVAR capacitor duty contactors – 3 Nos (iv) ON indication lamp – 3 Nos (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 6 Nos (vi) 5 kVAR 7% detuned reactor copper wound – 3 Nos (b) (i) 10 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 20 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 10 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 10 kVAR 7% detuned reactor copper wound – 1 No (c) (i) 25 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No
15.0452Srl Item No 15.045 Continued...... (ii) MCCB rated current(In): 50 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 25 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 25 kVAR 7% detuned reactor copper wound – 1 No (d) (i) 50 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 100 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 50 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 50 kVAR 7% detuned reactor copper wound – 1 No (e) (i) 100 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 2 Nos (ii) MCCB rated current(In): 200 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 2 Nos (iii) 100 kVAR capacitor duty contactors – 2 Nos (iv) ON indication lamp – 2 Nos
15.0453Srl Item No 15.045 Continued...... (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 4 Nos (vi) 100 kVAR 7% detuned reactor copper wound – 2 Nos Note: (a) The kVAR rating of capacitor mentioned is for rated voltage of 440 V. However, the capacitor shall be provided for rated voltage of 480 V by enhancing the kVAR rating suitably.
15.0460Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 150 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 150 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 100 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 80 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -17 Nos E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-100 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos LT002N1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0461Srl Item No 15.046 Continued...... (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm
15.0470Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 300 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 300 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 200 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 100 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 63 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No LT002O1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0471Srl Item No 15.047 Continued...... (c) MCCB rated current (In): 32 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm
15.0480Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 500 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 500 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 320 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 200 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 63 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -4 Nos LT002P1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0481Srl Item No 15.048 Continued...... (c) MCCB rated current (In): 40 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm
15.0490Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 100 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 100 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 63 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 20 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (b) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -3 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-100 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos LT002Q1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0491Srl Item No 15.049 Continued...... (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm
15.0500Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 30 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 30 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 20 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 16 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-100 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT LT002R1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0501Srl Item No 15.05 Continued...... (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm
15.0510Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 30 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 30 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 20 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 16 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-100 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT LT002S1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0511Srl Item No 15.051 Continued...... (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm
15.0520M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.19473C28.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0530M & L for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 2.5 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 4.00 mm dia galvanised earth wire by means of bolts, nuts, check nuts and washers of galvanised iron from pipe electrode to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.19475C2.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0540M & L for cable route indicator made out of CI plate 100 dia, 8 mm thick, embossed with lettering "MES LT Cable", welded or bolted onto 35 mm X 35 mm X 6 mm angle iron, 500 mm long duly painted with anti-corrosive paint in brown colour & including necessary earthwork and excavation, embedded in PCC M15(Nominal Mix) using 20 nominal size graded crushed stone aggregate of size 400 mm X 400 mm X 300 mm complete all as specified and as directed.19684B150.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0550Supply and erect factory made 7 meter long hot dip galvanized (as per relevant IS with average coating thickness 65 micron) octagonal poles conform to IS-2062/ BSEN 10025 with 155 mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet along with foundation type base plate of size 250 mm X 250 mm X 16 mm, foundation bolt 4 Nos of M20 X 600 mm high 'J' type EN8 grade, including 1 meter long hot dip galvanized single arm (swan neck) bracket made up of 40 NB dia GI pipe and including excavation, earth work, PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturer’s instructions including marking pole number in letters & figures of size not less than 10 cm height with red colour enamel paint complete all as specified and as directed. Note: - (i) Srl number will be issued by Engineer-in-Charge.19958Z176.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0560S & F three core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed.19813C1320.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0570Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 63 mm, minimum inside dia 47 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed.DWC00511325.90Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0580Supplying, installing, testing and commissioning diesel engine driven generating set 25 kVA /20 kW (prime power), 415 volt, 50 Hz, 3 phase, 4 wire, at 1500 rpm, 0.8 lagging power factor including diesel engine, alternator, coupling, common base plate, acoustic enclosure, 12 V DC battery, AMF Panel. Exhaust system, foundation etc. complete all as specified and as directed.19747E1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0590S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves, two ways in double control with wall flange, made of cast brass including knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.18102T68.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0600S & F single lever concealed divertor including bath spout and shower complete all as specified and as directed.84461L46.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0610S & F 15 mm wash basin mixture, centre hole, mixing hot & cold water, fancy type, cast copper alloy, chromium plated with capstan head, chromium plated, screwed down high pressure, screwed for iron pipe etc and fixed in repairs complete all as specified and directed by engineer in charge. Make : Jaquar Cat No: 5001B or equivalent as approved by the GE.83590D4.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0620S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed.18357D67.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySSR_BASED_MR
15.0630M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)19306Y1886.00Point - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0640M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)19306S4.00Point - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0650M & L for point wiring for one 3 pin/ 5 pin/ 6 pin 5/15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)19314Y310.00Point - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0660M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)19311Y106.00Point - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0670M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)19318Y45.00Point - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0680M & L for concealed point wiring for one light controlled by two 2-way switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)19310Y14.00Point - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0690M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)19319Y146.00Point - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0700S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 6 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.19455Z9.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0710S & F TPN distribution board 4 way vertical type double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper busbar of suitable rating, with neutral bar and earth bar and cable tie for cable management, IP54 Protection and provision and including MCCB 4 pole upto 160 Amp,16KA as incomer and provision for MCBs as outgoing, dust and vermin proof complete as per IEC61439-3 complete all as specified and as directed. Note: MCBs for outgoing shall be measured and paid separately.84461K14.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0720S & F blanking plate in DBs of MCB complete all as specified and as directed.19600A25.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0730Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)19509Y150.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0740Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)19510Y220.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0750Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)19516Y180.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0760Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 10 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 10 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 10 sqmm cable, two runs of 10 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)19517Y100.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0770M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.19471C58.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0780S & F LED bulb, System Wattage: 9 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.84461M278.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0790S & F LED bulb, System Wattage: 0.5 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.84461N40.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0800Supply, fixing and testing LED batten with battery/Invertor, LED Rating (in Watts)/System Wattage/Rated Power: 20 Watt, Rated Voltage & Frequency: 230V, 50Hz, Luminaire System Efficacy (Lumen/watt): 100, Operating Voltage Range: 140-280V, Power Factor: ≥0.95, Total Harmonic Distortion: ≤30%, Colour Rendering Index(CRI): ≥80, Colour Temperature: 5000⁰-6500⁰ Kelvin, Driver Efficiency: ≥85%, Emergency Time: 3 hour, Ingress Protection: IP-20, Type of Control Gears: Electronic, Working life for LED (as per LM-80 and LM 21 reports): ≥50000 hours, Housing Material: Aluminium Extruded, Front Cover Material: Polycarbonate, Surge Protection of 3.0 kV Internal: Yes, Open & Short Circuit Protection: Yes, Reverse Polarity Protection: Yes, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Emergency Light Output (Lumen %): 50, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.844671218.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0810Supplying, installing, testing and commission of commercial kitchen stainless steel exhaust, chimney/ hood system having the following components: - (a) Commercial kitchen stainless steel hood (6 feet long/ 2.8 feet wide) of stainless steel 304 grade, double filter absorber type, rust free grade steel, inbuilt with automatic sensor as per OEM specifications. (b) Automatic mode changer (drift air), turbo force 5 HP motor with bird screen for protection against bird and foreign materials, rust free body and plates, automatic shutter function complete metal body (c) Double coated high grade ducting material 40 feet long, high quality material as per OEM specifications Note: The contractor shall design the ducting portion as per the drawings and room capacity of kitchen portion of the drawings and calculate the requirement of ducting and submit the design to the GE for approval. The quoted rate shall be inclusive of all these aspects.8445963.00Each Job - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0820S & F including testing LED high bay 50 watt luminaire with aluminium die cast housing with mechanical mechanism for mounting, with driver complete suitable for fixation on wall/roof/railings with robust body, corrosion resistant, superior finish. The system wattage of fitting should not be more than 50 watt ± 10%, having surge protection of minimum 4kV internal, power factor more than 0.95, corelated colour temperature should 5700⁰-6500⁰ Kelvin, total hormonic distortion (THD) should not be more than 10%, lumen efficacy should not be less than 130 lumens per watt, total input voltage range 140-270V AC, colour rendering Index should not be less than 70, IP65 protection level complete all as specified and directed. Note: - (i) Cost of mechanical mountings and holders for lights, nut & bolts are inclusive in this item.HB001A10.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0830S & F telephone sockets (Jack type) RJ 11-jack-1 module as per Legrand catalogue No. 674521 or equivalent of L&T, Siemens complete all as specified and as directed.19754A17.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0840S & F television antenna socket outlet including metal box complete all as specified and as directed.36002A44.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0850Supply and fix PP manifold of size 75mm for Filter Unit of Drip and Pop-up system with connected accessories Complete all as specified and directed by Engineer-In-Charge. 84529B3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0860Supply, fixing Ventury with Ferttigation Manifold assemble size of 63 mm for head control unit IS: 14483:1997 with all acessories Complete all as specified and directed by Engineer-In-Charge. 84529C3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0870Supply and fixing Air relese valve (plastic) size of 25 mm dia for head control unit in dirip irrigation system. Complete all as specified and directed by Engineer-In-Charge. 84529D3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0880Supply and fixing Pressure gauge (glycerine) cap of 0-7 kg/cm² size of 63mm dia for head control unit in dirip irrigation system Complete all as specified and directed by Engineer-In-Charge. 84529E3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0890Supply and fixing Screen filter (plastic) with 2 solid flange size of 75 mm dia and capacity of 30 m³/hr for head control unit in drip irrigation system IS : 12785:1994 Complete all as specified and directed by Engineer-In-Charge. 84529F3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0900Supply and fixing PP control valve size of 75mm for controlling water in storage tank for drip irrigation system Complete all as specified and directed by Engineer-In-Charge. 84529G3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0910Supply and fixing PVC pipe (4 kg/cm²) IS ; 4984:2016, size of 90 mm dia for main distribution line in drip irrigation system and including all connected accessories .(ie Socket,Bend,Elbow,Tee,Reducer, connector, Solvent,clamps etc) Complete all as specified and directed by Engineer-In-Charge. 84529H330.00RM - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0920Supply and fixing PVC pipe (4 kg/cm²) IS ; 4984:2016, size of 75 mm for Main line in Pop-up and Drip irrigation system including all connected accessories. (ie Elbow,FTA,MTA,Tee,Solvent, clamps etc) Complete all as specified and directed by Engineer-In-Charge. 84529I200.00RM - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0930Supply and fixing PVC pipe (6 kg/cm²) IS ; 4985:2000 size of 63 mm dia for sub distribution line in dirip irrigation system and including all connected accessories (ie Socket,Bend,Elbow, Tee, Reducer,connector, Solvent,clamps etc) Complete all as specified and directed by Engineer-In-Charge. 84529J500.00RM - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0940Supply and fixing PVC pipe (6 kg/cm²) IS ; 4985:2000 size of 50 mm dia for sub distribution line in dirip irrigation system and including all connected accessories (ie Socket,Bend,Elbow, Tee, Reducer,connector, Solvent,clamps etc) Complete all as specified and directed by Engineer-In-Charge. 84529K550.00RM - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0950Supply and fixing Plain lateral 2.5 kg/cm², class II size of 32 mm dia, for water distribution line in dirip irrigation system and including all connected accessories (ie Socket,Bend,Elbow,Tee, Reducer, connector, suitable size Grommat Joiner 16mm take off, End cap, etc) Complete all as specified and directed by Engineer-In-Charge. 84529L280.00RM - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0960Supply and fixing Plain lateral 2.5 kg/cm², class II size of 16mm dia,online for water distribution line in drip irrigation system including all connected accessories (ie Grommat, Lateral cock, End cap for connection in UPVC/Plain lateral pipe etc) (For trees) Complete all as specified and directed by Engineer-In-Charge. 84529M1650.00RM - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0970Supply and fixing Emitting pipe of dia 16 mm, discharge 2 LPH, dripper spacing 30 cm. 2,5 kg/cm², IS:13488, including all connected accessories (ie Socket,Bend,Elbow,Tee,connector, suitable size Grommat,Joiner etc.(for hedge) Complete all as specified and directed by Engineer-In-Charge. 84529N680.00RM - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0980Supply and fixing PVC Control valve size of 75 mm dia for head control unit sub distribution line in dirip irrigation system and all connected accessories Complete all as specified and directed by Engineer-In-Charge. 84529O3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.0990Supply and fixing PVC Control valve size of 63 mm dia for head control unit sub distribution line in dirip irrigation system and all connected accessories Complete all as specified and directed by Engineer-In-Charge. 84529P5.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1000Supply and fixing PVC Control valve size of 90 mm dia for head control unit sub distribution line in dirip irrigation system and all connected accessories Complete all as specified and directed by Engineer-In-Charge. 84529Q3.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1010Supply and fixing Flush valve size of 75x63 mm dia for sub distribution line in dirip irrigation system Complete all as specified and directed by Engineer-In-Charge. 84529R6.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1020Supply and fixing PVC service saddle of 50X1/4 mm dia including MT and FT for water distribution line in dirip irrigation system Complete all as specified and directed by Engineer-In-Charge. 84529S77.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1030Supply and fixing push type male threaded adopter size of 32 mm dia for water distribution line in dirip irrigation system complete all as specified and directed by engineer -In-Charge.(For Hedges) Make :- Finolex/supreme/ Prince/kisan/Tirupati or eaquivalent. 84529T5.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1040Supply and fixing PP control valve (Th. End) size of 32 mm dia for sub distribution line in dirip irrigation system complete all as specified and directed by engineer -In-Charge. Make :- Finolex/supreme/ Prince/kisan/Tirupati or eaquivalent. 84529U5.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1050Supply and fixing Dripper cap 8 LPH for dirip irrigation system and connected accessories complete all as specified and directed by engineer -In-Charge. Make :- Finolex/supreme/ Prince/kisan/Tirupati or eaquivalent. 84529V716.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1060Supply and fixing Swing joint full three way adjustability including neight for Pop-Up Impact Sprinkler, bush with connected accessories, durable polyethylene construction for 3/4" size. Complete all as specified and directed by Engineer -In-Charge.Make Aquaturf84529W77.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1070Supply and fixing Pop-Up Impact sprinkler of heavy duty Plastic, adjustable to full-circle or Part circle with diffuser screw for fine drop lets and throw control, inlet size 3/4", having radious of throw up to 12 mtrs at pressure 4 kg/cm² omplete all as specified and directed by engineer -In-Charge. Make Aquaturf. 84529X77.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1080Supply and fixing PVC End cap size of 50 mm dia for water distribution line in Pop-Up irrigation system and all including complete accessories all as specified and directed. 84529Y10.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1090Supply and fixing Robust top cover with nonslippery grip Plastic heavy duty extended bottom keeps the valve box stable and firmly set in the soil with Green Top and black base Size 10" rectangular shape at Pop-up distribution line and including all connected accessories complete all as specified and directed.84529Z8.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1100Supply, fixing and testing of Submersible pumpset as per requirement 2 HP capacity with supply voltage 415 V, three phase, 50 HZ,with 3000RPM in stainless steel body with inlet filter driven by suitable for operation with operating head 28-14 Mtr and having capacity to discharge water 1.9-0.4 LPS with suction and discharge flanged suction 40 X 40 mm including suitable size of strainer mounted on suitable for existing surface with MS bolts, nuts of required size and necessary control valves, properly connected with suction and delivery water line, including three core copper conductor cable from starter panel to motor terminal as per suitable size including all connected accessories all as specified and directed by Engineer -In -Charge.(Make : CG /Kirloskar/MBH Pumps/KSB/Mather & Platt or equivalent).(One Number working for Adm Block, 01 No. Spare)A845292.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1110Supply, fixing and testing of Submersible pumpset as per requirement 1.5 HP capacity with supply voltage 415 V, three phase, 50 HZ,with 3000RPM in stainless steel body with inlet filter driven by suitable for operation with operating head 28-14 Mtr and having capacity to discharge water 1.9-0.4 LPS with suction and discharge flanged suction 40 X 40 mm including suitable size of strainer mounted on suitable for existing surface with MS bolts, nuts of required size and necessary control valves, properly connected with suction and delivery water line, including three core copper conductor cable from starter panel to motor terminal as per suitable size including all connected accessories all as specified and directed by Engineer -In -Charge.(Make : CG /Kirloskar/MBH Pumps/KSB/Mather & Platt or equivalent).(One Number working for Adm Block, 01 No. Spare)B845294.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1120Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in road cutting (road includes flexible pavement, rigid pavement, interlocking pavement etc. ) complete all as specified and as directed.03006S2.00Cum - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1130S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 5000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.18082G4.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1140M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.19216C2480.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero OnlySSR_BASED_MR
15.1150M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed.19613G30.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1160M & L for construction of new valve pit/chamber of size 750 mm (Length) X 750 mm (Breadth) X 750 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed.18380Q6.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1170Supply & Fixing Star delta starter control panel 1.5 HP on wall with all fitting arrangement & comprising of following accessories complete all as specified & as directed. (a) Star Delta Starter Motor starter in sheet steel enclosure, suitable for 1.5 HP electric Motor, 3 phase, 415 volt, 50 Hz – 01 No & Single phase preventer suitable for 1.5 HP submersible pump set -01 No (b) MCB TPN 16 Amp -01 (c) Digital Volt meter 0-500 Volts with selector switch – 01 No. (d) Digital Ampere meter 0-50 Amp with selector switch – 01 No (e) Indicating Lamp RYB “LED” type complete – 01 Set C845292.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1180Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 63 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 63 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 25 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 16 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, for 415 V, 50 Hz AC supply: -1 No (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-100 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT LT002T1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1181Srl Item No 15.118 Continued...... (e) Single phase preventer suitable for 5/7.5 HP submersible pump each set. (f) Star Delta Starter in steel sheet enclosure suitable for 7.5 HP electric motor three phase, 415 volts, 50 Hz-02 Nos. (g) Space for mounting Star Delta Starter 7.5 HP electric motor three phase, 415 volts, 50 Hz-01 No (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm
15.1190M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.19472C6.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1200M & L for cutting galvanised mild steel pipe of nominal bore 200 mm, in position for and including insertion of new tee piece including necessary fittings and fixtures complete all as specified and as directed.18023J1.00Each - Excess(+)1Full ConversionINR0.000.00INR Zero Only
15.1210S & F single core flexible conductor FR-LSH cables, PVC insulation of type C and having PVC sheath of type ST2, 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor laid in existing conduit complete all as specified and as directed.19813T80.00Running Metre - Excess(+)1Full ConversionINR0.000.00INR Zero Only
Total in Figures0.000.00INR Zero Only
Quoted Rate in FiguresSelect0.00000.0000 Zero Only
Quoted Rate in WordsINR Zero Only