Bidhelp
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE SC AND CE PUNE ZONE - MES||CWE (ARMY) MUMBAI - MES||GE (WEST) COLABA - MES
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE SC AND CE PUNE ZONE - MES||CWE (ARMY) MUMBAI - MES||GE (WEST) COLABA - MES
Kameshwar Prasad, IDSE, EE
Maharashtra QTY :

Items - REPAIR/ MAINT OF OLD LT SWITCH GEARS, FEEDER PILLAR BOXES AND LT CABLES INCLUDING CONNECTED ITEMS UNDER GE (W) COLABA, MUMBAI

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver4.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority: GARRISON ENGINEER (WEST) COLABA MUMBAI
Name of Work: Repair/ Maint of old LT switch gears, feeder pillar boxes and LT Cables including connected items under GE (W) Colaba, Mumbai
File No : 8115/E8
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Rs. P Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNTTOTAL AMOUNT With TaxesTOTAL AMOUNT In Words
12334678910111251415161718192021222324252627282930313233343536373839404142434445464748495051526547
1.00Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out complete in soft/loose soil, complete all as specified and direted.itemH1Code1160.99Cum0.00Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
2.00All as per sl. item No.01 above but in hard/dense soil.itemH1Code2143.10Cum1.00Excess(+)1Full ConversionINR0.000.00INR Zero Only2.01Supplying, Conveying and fixing spls. Including eartitem2124.223Nos
3.00Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assembly and laying of U/G cables etc. and getting out in hard rock/road cutting/RCC/PCC, complete all as specified and direted.itemH1Code359.63Cum2.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3.01Supplying, Conveying and fixing spls. Including eartitem3125.223Nos
4.00Returning, filling in soft/loose soil including spreading, levelling, watering ,well ramming in layers n.exc 25 cm, complete all as specified and direted.itemH1Code4171.72Cum3.00Excess(+)1Full ConversionINR0.000.00INR Zero Only4.01Supplying, Conveying and fixing spls. Including eartitem4126.223Nos
5.00Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point.in soft /loose soil, complete all as specified and direted.itemH1Code5153.59Cum4.00Excess(+)1Full ConversionINR0.000.00INR Zero Only5.01Supplying, Conveying and fixing spls. Including eartitem5127.223Nos
6.00Removing of excavated material from the site of work and transporting out of MD land, complete all as specified and directed.itemH1Code638.40Cum5.00Excess(+)1Full ConversionINR0.000.00INR Zero Only6.01Supplying, Conveying and fixing spls. Including eartitem6128.223Nos
7.00Supply and providing unreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) of sizes Class LV type I, flat size 250x150x40 mm putting adjecent to each other, complete all as specified and direted.itemH1Code75300.00Each6.00Excess(+)1Full ConversionINR0.000.00INR Zero Only7.01Supplying, Conveying and fixing spls. Including eartitem7129.223Nos
8.00Supply and laying tubes light grade, galvanized, 100 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable, complete all as specified and direted.itemH1Code880.00RM7.00Excess(+)1Full ConversionINR0.000.00INR Zero Only8.01Supplying, Conveying and fixing spls. Including eartitem8130.223Nos
9.00Supply and laying tubes light grade, galvanized, 80 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable, complete all as specified and direted.itemH1Code9100.00RM8.00Excess(+)1Full ConversionINR0.000.00INR Zero Only9.01Supplying, Conveying and fixing spls. Including eartitem9131.223Nos
10.00Supply and laying tubes light grade, galvanized, 50 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric, complete all as specified and direted.itemH1Code1080.00RM9.00Excess(+)1Full ConversionINR0.000.00INR Zero Only10.01Supplying, Conveying and fixing spls. Including eartitem10132.223Nos
11.00Supply and laying tubes light grade, galvanized, 40 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable, complete all as specified and direted.itemH1Code11100.00RM10.00Excess(+)1Full ConversionINR0.000.00INR Zero Only11.01Supplying, Conveying and fixing spls. Including eartitem11133.223Nos
12.00M&L cement concrete 1:2:4 type B-1 using 20mm graded aggregate in width for Feeder panel foundation/road filling including including rafts, footings, foundation beams plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and direted.itemH1Code1210.00Cum11.00Excess(+)1Full ConversionINR0.000.00INR Zero Only12.01Supplying, Conveying and fixing spls. Including eartitem12134.223Nos
13.00Taking down/ dismantling carefully old UNSV feeder panel by discoonecting all connected cables and reconnecting same cables with new feederpanels, complete all as specified and directed.itemH1Code135.00Each Job12.00Excess(+)1Full ConversionINR0.000.00INR Zero Only13.01Supplying, Conveying and fixing spls. Including eartitem13135.223Nos
14.00Material & Labour for cable fault detection at various locations by all T & P, Equipments for HT CABLE XLPE aluminium conductor from feeder panel to feeder panel including testing and commissioning, complete all as specified and direted.itemH1Code143.00Each13.00Excess(+)1Full ConversionINR0.000.00INR Zero Only14.01Supplying, Conveying and fixing spls. Including eartitem14136.223Nos
15.00Material & Labour for cable fault detection at various locations by all T & P, Equipments for LT CABLE XLPE aluminium conductor from feeder panel to feeder panel including testing and commissioning, complete all as specified and directed.itemH1Code1512.00Each14.00Excess(+)1Full ConversionINR0.000.00INR Zero Only15.01Supplying, Conveying and fixing spls. Including eartitem15137.223Nos
16.00Material & Labour for cable route detection at various locations by all T & P, Equipments for LT CABLE XLPE aluminium conductor from feeder panel to feeder panel including testing and commissioning, complete all as specified and directed.itemH1Code16500.00RM15.00Excess(+)1Full ConversionINR0.000.00INR Zero Only16.01Supplying, Conveying and fixing spls. Including eartitem16138.223Nos
17.00Taking down for old UNSV cable from trench/wall/duct, complete all as specified and direted.itemH1Code172650.00RM16.00Excess(+)1Full ConversionINR0.000.00INR Zero Only17.01Supplying, Conveying and fixing spls. Including eartitem17139.223Nos
18.00Supplying, laying, commissioning & testing LT underground cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor all as per IS 7098 (Part -1) laid in trenches, ducts, drawn through pipes or fixed on poles, as and when required on ground of following size:- 300 Sqmm X 3.5 Core.itemH1Code1850.00RM17.00Excess(+)1Full ConversionINR0.000.00INR Zero Only18.01Supplying, Conveying and fixing spls. Including eartitem18140.223Nos
19.00All as per item No. 18 but for cable size 240 Sqmm X 3.5 CoreitemH1Code19300.00RM18.00Excess(+)1Full ConversionINR0.000.00INR Zero Only19.01Supplying, Conveying and fixing spls. Including eartitem19141.223Nos
20.00All as per item No. 18 but for cable size 150 Sqmm X 3.5 Core.itemH1Code20300.00RM19.00Excess(+)1Full ConversionINR0.000.00INR Zero Only20.01Supplying, Conveying and fixing spls. Including eartitem20142.223Nos
21.00All as per item No. 18 but but for cable size 120 Sqmm X 3.5 Core.itemH1Code21300.00RM20.00Excess(+)1Full ConversionINR0.000.00INR Zero Only21.01Supplying, Conveying and fixing spls. Including eartitem21143.223Nos
22.00All as per item No. 18 but for cable size 95 Sqmm X 3.5 Core.itemH1Code22400.00RM21.00Excess(+)1Full ConversionINR0.000.00INR Zero Only22.01Supplying, Conveying and fixing spls. Including eartitem22144.223Nos
23.00All as per item No. 18 but for cable size 70 Sqmm X 3.5 Core.itemH1Code23400.00RM22.00Excess(+)1Full ConversionINR0.000.00INR Zero Only23.01Supplying, Conveying and fixing spls. Including eartitem23145.223Nos
24.00All as per item No. 18 but for cable size 50 Sqmm X 3.5 Core.itemH1Code24400.00RM23.00Excess(+)1Full ConversionINR0.000.00INR Zero Only24.01Supplying, Conveying and fixing spls. Including eartitem24146.223Nos
25.00All as per item No. 18 but for cable size 35 Sqmm X 3.5 Core.itemH1Code25200.00RM24.00Excess(+)1Full ConversionINR0.000.00INR Zero Only25.01Supplying, Conveying and fixing spls. Including eartitem25147.223Nos
26.00All as per item No. 18 but for cable size 25 Sqmm X 3.5 Core.itemH1Code26100.00RM25.00Excess(+)1Full ConversionINR0.000.00INR Zero Only26.01Supplying, Conveying and fixing spls. Including eartitem26148.223Nos
27.00All as per item No. 18 but for cable size 16 Sqmm X 4 Core.itemH1Code27100.00RM26.00Excess(+)1Full ConversionINR0.000.00INR Zero Only27.01Supplying, Conveying and fixing spls. Including eartitem27149.223Nos
28.00All as per item No. 18 but for cable size 16 Sqmm X 2 Core.itemH1Code28100.00RM27.00Excess(+)1Full ConversionINR0.000.00INR Zero Only28.01Supplying, Conveying and fixing spls. Including eartitem28150.223Nos
29.00Material & Labour for cable jointing kit, in repairs for LT CABLE XLPE aluminium conductor including testing and commissioning complete for the size of 35 sqmm X 3.5 Core, complete all as specified and directed.itemH1Code296.00Each28.00Excess(+)1Full ConversionINR0.000.00INR Zero Only29.01Supplying, Conveying and fixing spls. Including eartitem29151.223Nos
30.00All as per item No. 29 above but of size 50 sqmm X 3.5 Core.itemH1Code308.00Each29.00Excess(+)1Full ConversionINR0.000.00INR Zero Only30.01Supplying, Conveying and fixing spls. Including eartitem30152.223Nos
31.00All as per item No. 29 above but of size 70 sqmm X 3.5 Core.itemH1Code318.00Each30.00Excess(+)1Full ConversionINR0.000.00INR Zero Only31.01Supplying, Conveying and fixing spls. Including eartitem31153.223Nos
32.00All as per item No. 29 above but of size 95 sqmm X 3.5 Core.itemH1Code3210.00Each31.00Excess(+)1Full ConversionINR0.000.00INR Zero Only32.01Supplying, Conveying and fixing spls. Including eartitem32154.223Nos
33.00All as per item No. 29 above but of size 120 sqmm X 3.5 Core.itemH1Code3310.00Each32.00Excess(+)1Full ConversionINR0.000.00INR Zero Only33.01Supplying, Conveying and fixing spls. Including eartitem33155.223Nos
34.00All as per item No. 29 above but of size 185 sqmm X 3.5 Core.itemH1Code348.00Each33.00Excess(+)1Full ConversionINR0.000.00INR Zero Only34.01Supplying, Conveying and fixing spls. Including eartitem34156.223Nos
35.00All as per item No. 29 above but of size 240 sqmm X 3.5 Core.itemH1Code356.00Each34.00Excess(+)1Full ConversionINR0.000.00INR Zero Only35.01Supplying, Conveying and fixing spls. Including eartitem35157.223Nos
36.00All as per item No. 29 above but of size 300 sqmm X 3.5 Core.itemH1Code362.00Each35.00Excess(+)1Full ConversionINR0.000.00INR Zero Only36.01Supplying, Conveying and fixing spls. Including eartitem36158.223Nos
37.00Taking out/down for old cable and rerouting, re laying, saddling the same after checking, meggaring complete LT underground cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty of size 10 sqmm X 2 Core to 50 sqmm X 3.5 Core including connecting up electric power to panel/feeder box, complete all as specified and directed.itemH1Code37200.00RM36.00Excess(+)1Full ConversionINR0.000.00INR Zero Only37.01Supplying, Conveying and fixing spls. Including eartitem37159.223Nos
38.00Taking out/down for old cable and rerouting, re laying, saddling the same after checking, meggaring complete LT underground cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty of size 70 sqmm X 3.5 Core to 240 sqmm X 3.5 Core including connecting up electric power to panel/feeder box, complete all as specified and directed.itemH1Code38200.00RM37.00Excess(+)1Full ConversionINR0.000.00INR Zero Only38.01Supplying, Conveying and fixing spls. Including eartitem38160.223Nos
39.00Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch, 4Pole, 250 Amps, Open Execution (Open Enclosure), ON LOAD type 415Volts, 50Hz AC including enclosure, complete all as specified and directed by Engr-in-charge. itemH1Code391.00Each Job38.00Excess(+)1Full ConversionINR0.000.00INR Zero Only39.01Supplying, Conveying and fixing spls. Including eartitem39161.223Nos
40.00Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch, 4Pole, 250 Amps, Open Execution (Closed Enclosure), ON LOAD type 415Volts, 50Hz AC including enclosure, complete all as specified and directed by Engr-in-charge. itemH1Code401.00Each Job39.00Excess(+)1Full ConversionINR0.000.00INR Zero Only40.01Supplying, Conveying and fixing spls. Including eartitem40162.223Nos
41.00Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch, 4Pole, 320/400 Amps, Open Execution (Open Enclosure), ON LOAD type 415Volts, 50Hz AC including enclosure, complete all as specified and directed by Engr-in-charge. itemH1Code412.00Each Job40.00Excess(+)1Full ConversionINR0.000.00INR Zero Only41.01Supplying, Conveying and fixing spls. Including eartitem41163.223Nos
42.00Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Outdoor Change Over Switch, 4Pole, 320/400 Amps, Open Execution (Closed Enclosure), ON LOAD type 415Volts, 50Hz AC including enclosure, complete all as specified and directed by Engr-in-charge. itemH1Code422.00Each Job41.00Excess(+)1Full ConversionINR0.000.00INR Zero Only42.01Supplying, Conveying and fixing spls. Including eartitem42164.223Nos
43.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 4Pole, 320/400 Amps, 35/36kA, 415Volts, 50Hz AC s with enclosure of 2.00 mm thick for indoor S/S fixing on wall complete all as specified and directed by Engr-in-charge.itemH1Code433.00Each Job42.00Excess(+)1Full ConversionINR0.000.00INR Zero Only43.01Supplying, Conveying and fixing spls. Including eartitem43165.223Nos
44.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 4Pole, 250 Amps, 35/36kA, 415Volts, 50Hz AC s with enclosure of 2.00 mm thick for indoor S/S fixing on wall, complete all as specified and directed by Engr-in-charge.itemH1Code442.00Each Job43.00Excess(+)1Full ConversionINR0.000.00INR Zero Only44.01Supplying, Conveying and fixing spls. Including eartitem44166.223Nos
45.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 4Pole, 320/400 Amps, 35/36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.itemH1Code453.00Each Job44.00Excess(+)1Full ConversionINR0.000.00INR Zero Only45.01Supplying, Conveying and fixing spls. Including eartitem45167.223Nos
46.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 4Pole, 250 Amps, 35/36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.itemH1Code462.00Each Job45.00Excess(+)1Full ConversionINR0.000.00INR Zero Only46.01Supplying, Conveying and fixing spls. Including eartitem46168.223Nos
47.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 4 Pole, 200 Amps, 35/36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.itemH1Code472.00Each Job46.00Excess(+)1Full ConversionINR0.000.00INR Zero Only47.01Supplying, Conveying and fixing spls. Including eartitem47169.223Nos
48.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 200 Amps, 35/36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.itemH1Code484.00Each Job47.00Excess(+)1Full ConversionINR0.000.00INR Zero Only48.01Supplying, Conveying and fixing spls. Including eartitem48170.223Nos
49.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 160 Amps, 36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.itemH1Code493.00Each Job48.00Excess(+)1Full ConversionINR0.000.00INR Zero Only49.01Supplying, Conveying and fixing spls. Including eartitem49171.223Nos
50.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 100 Amps, 36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.itemH1Code505.00Each Job49.00Excess(+)1Full ConversionINR0.000.00INR Zero Only50.01Supplying, Conveying and fixing spls. Including eartitem50172.223Nos
51.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 100 Amps, 10kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.itemH1Code515.00Each Job50.00Excess(+)1Full ConversionINR0.000.00INR Zero Only51.01Supplying, Conveying and fixing spls. Including eartitem51173.223Nos
52.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 63 Amps, 36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.itemH1Code525.00Each Job51.00Excess(+)1Full ConversionINR0.000.00INR Zero Only52.01Supplying, Conveying and fixing spls. Including eartitem52174.223Nos
53.00Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 63 Amps, 10kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.itemH1Code535.00Each Job52.00Excess(+)1Full ConversionINR0.000.00INR Zero Only53.01Supplying, Conveying and fixing spls. Including eartitem53175.223Nos
54.00Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric panels by taking shut down from appropiate authority including T&P for Attending Faults/Trippings and rectifieng /repairing the faults in HT/LT Panels Boards/Capacitor Panels Boaeds/ MCCB's/ACB's /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. (i) Tightning the loose connections and cleaning inside/out side complete replacing faulty insulation ,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting as pproved colour and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed. (Note : MCCB,ACB, Painting measured and paid separately under relevant items of this schedule.)itemH1Code5460.00Each Job53.00Excess(+)1Full ConversionINR0.000.00INR Zero Only54.01Supplying, Conveying and fixing spls. Including eartitem54176.223Nos
55.00Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing, complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts will be measured and paid separately)itemH1Code552.00Each Job54.00Excess(+)1Full ConversionINR0.000.00INR Zero Only55.01Supplying, Conveying and fixing spls. Including eartitem55177.223Nos
56.00Dismantling/Maintenance of Old Damaged/burnt spare parts from ACB and Supply and fixing in repair of following Spare parts suitable for -ACB 415V, 630 to 1200Amps Amps indoor type, complete all as specified and directed by Engineer-in-Charge.itemH1Code565.00Each Job55.00Excess(+)1Full ConversionINR0.000.00INR Zero Only56.01Supplying, Conveying and fixing spls. Including eartitem56178.223Nos
57.00Shunt Trip DeviceitemH1Code573.00Each56.00Excess(+)1Full ConversionINR0.000.00INR Zero Only57.01Supplying, Conveying and fixing spls. Including eartitem57179.223Nos
58.00Closing coil assemblyitemH1Code583.00Each57.00Excess(+)1Full ConversionINR0.000.00INR Zero Only58.01Supplying, Conveying and fixing spls. Including eartitem58180.223Nos
59.00Mismatch Prevention DeviceitemH1Code593.00Each58.00Excess(+)1Full ConversionINR0.000.00INR Zero Only59.01Supplying, Conveying and fixing spls. Including eartitem59181.223Nos
60.00Moving contacts assemblyitemH1Code603.00Each59.00Excess(+)1Full ConversionINR0.000.00INR Zero Only60.01Supplying, Conveying and fixing spls. Including eartitem60182.223Nos
61.00Fixed Contact assembly itemH1Code613.00Each60.00Excess(+)1Full ConversionINR0.000.00INR Zero Only61.01Supplying, Conveying and fixing spls. Including eartitem61183.223Nos
62.00Auxiliary SwitchitemH1Code623.00Each61.00Excess(+)1Full ConversionINR0.000.00INR Zero Only62.01Supplying, Conveying and fixing spls. Including eartitem62184.223Nos
63.00Arc chut with hardwareitemH1Code633.00Each62.00Excess(+)1Full ConversionINR0.000.00INR Zero Only63.01Supplying, Conveying and fixing spls. Including eartitem63185.223Nos
64.00Current Transformers 300A/5A.itemH1Code643.00Each63.00Excess(+)1Full ConversionINR0.000.00INR Zero Only64.01Supplying, Conveying and fixing spls. Including eartitem64186.223Nos
65.00Current Transformers 630A/5A.itemH1Code653.00Each64.00Excess(+)1Full ConversionINR0.000.00INR Zero Only65.01Supplying, Conveying and fixing spls. Including eartitem65187.223Nos
66.00Current Transformers 800A/5AitemH1Code663.00Each65.00Excess(+)1Full ConversionINR0.000.00INR Zero Only66.01Supplying, Conveying and fixing spls. Including eartitem66188.223Nos
67.00Current Transformers 1200A/5AitemH1Code673.00Each66.00Excess(+)1Full ConversionINR0.000.00INR Zero Only67.01Supplying, Conveying and fixing spls. Including eartitem67189.223Nos
68.00Dismantling of old damaged Meters and Supply & fix Digital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt, complete all as specified and directed.itemH1Code6810.00Each67.00Excess(+)1Full ConversionINR0.000.00INR Zero Only68.01Supplying, Conveying and fixing spls. Including eartitem68190.223Nos
69.00Dismantling of old damaged Meters Supply & fixing Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, programmable type, complete all as specified and directed.itemH1Code6910.00Each68.00Excess(+)1Full ConversionINR0.000.00INR Zero Only69.01Supplying, Conveying and fixing spls. Including eartitem69191.223Nos
70.00Cleaning the vegetation including glass, bushes small trees and all vegetation growth complete including digging out the root of bushes and small trees around the feeder panel. filling the rough holes with earth and levelling the surfaces by removing all debris outside MD land, complete all as specified and directed.itemH1Code70300.00Sqm69.00Excess(+)1Full ConversionINR0.000.00INR Zero Only70.01Supplying, Conveying and fixing spls. Including eartitem70192.223Nos
71.00M & L for Painting with of LT panels/ LT feeder panels of any size and type including one coat of primer paint all including scrapping out the old paint by scrubbing and application of primer before double coat of paint including minor repair like welding of hinges, repairing of lock and key arrangements, complete all as specified and directed by Engineer - in - Charge.itemH1Code7130.00Each Job70.00Excess(+)1Full ConversionINR0.000.00INR Zero Only71.01Supplying, Conveying and fixing spls. Including eartitem71193.223Nos
72.00Material and Labour for Attending Faults/Trippings and rectifieng /repairing the faults in LT Panels Boards/Capacitor Panels Boaeds/ MCCB's/ACB's /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Damaged/Burnt MCCB/ACB'S/Changeover switc/ Lugs will be measured and paid separately)itemH1Code7440.00Each Job73.00Excess(+)1Full ConversionINR0.000.00INR Zero Only74.01Supplying, Conveying and fixing spls. Including eartitem74196.223Nos
73.00Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 185 Sqmm to 400 Sqmm, complete all as specified and directed by Engr-in-charge.itemH1Code7550.00Each Job74.00Excess(+)1Full ConversionINR0.000.00INR Zero Only75.01Supplying, Conveying and fixing spls. Including eartitem75197.223Nos
74.00Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 16 Sqmm to 150 Sqmm, complete all as specified and directed by Engr-in-charge.itemH1Code7650.00Each Job75.00Excess(+)1Full ConversionINR0.000.00INR Zero Only76.01Supplying, Conveying and fixing spls. Including eartitem76198.223Nos
75.00Supply & fixing Aluminium Bus Bar strips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size, complete all as specified and as directed. Note:- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. itemH1Code7710.00Each Job76.00Excess(+)1Full ConversionINR0.000.00INR Zero Only77.01Supplying, Conveying and fixing spls. Including eartitem77199.223Nos
76.00Supply & fixing Copper Bus Bar strip, of any size, for extention of MCCB terminals for cable terminations, inside the cable alleoy of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size, complete all as specified and as directed. Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. itemH1Code785.00Each Job77.00Excess(+)1Full ConversionINR0.000.00INR Zero Only78.01Supplying, Conveying and fixing spls. Including eartitem78200.223Nos
77.00Supply and fixing of suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium bars, for cable terminations, duly fixed in the body of the panel board by and including galvanized steel bolts , nuts, washers etc.and necessary drillings, in the panel body, complete all as specified and as directed.itemH1Code79100.00Each Job78.00Excess(+)1Full ConversionINR0.000.00INR Zero Only79.01Supplying, Conveying and fixing spls. Including eartitem79201.223Nos
78.00Dismantling of Damaged/Burnt out control wiring of LT panels/ feeder panels and Supply & fixing of new control wiring of panels of any size with PVC Insulation Tape including all indicating lamps, complete all as specified and directed by Engr-in-charge.itemH1Code8010.00Each Job79.00Excess(+)1Full ConversionINR0.000.00INR Zero Only80.01Supplying, Conveying and fixing spls. Including eartitem80202.223Nos
79.00S&F in repairs steel perforated cable trunking system of size 60X30 mm and providing sturdy nuts and bolts for connecting cable trunking steadily onto walls or lying in air steadily with help of metal frame, complete all as specified and directed.itemH1Code186100.00RM185.00Excess(+)1Full ConversionINR0.000.00INR Zero Only186.01Supplying, Conveying and fixing spls. Including eartitem186308.223Nos
80.00S&F in repairs PVC cable trunking system of size 60X30 mm and providing sturdy nuts and bolts for connecting cable as per requirment on site including necessary fixing arrangement, complete all as specified and directed.itemH1Code187350.00RM186.00Excess(+)1Full ConversionINR0.000.00INR Zero Only187.01Supplying, Conveying and fixing spls. Including eartitem187309.223Nos
81.00M & L for Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth lead strip 25 x 4 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No3 of MESschedule part-I, earth lead strip connected to indicated position including concrete pit in PCC(1:3:6, C-1), Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil, complete all as specified and as directed and testing on completion. Note: Meggering Value of earthing resistance should be less than 2 Ohm.itemH1Code18815.00Each187.00Excess(+)1Full ConversionINR0.000.00INR Zero Only188.01Supplying, Conveying and fixing spls. Including eartitem188310.223Nos
82.00Supply & Fix Earth continuty conductor fixed to wall/surface or recess or burried in ground or any situation for loop earthing by 25 X 4 mm GI strip, complete all as specified and directed by Engineer-in-Charge.itemH1Code189100.00RM188.00Excess(+)1Full ConversionINR0.000.00INR Zero Only189.01Supplying, Conveying and fixing spls. Including eartitem189311.223Nos
Total in Figures0.000.00INR Zero Only4Construction of chamber for 100mm sluice platesitem510Nos
Quoted Rate in FiguresSelect0.00000.0000 Zero Only
Quoted Rate in WordsINR Zero Only