Items - REPAIRS TO MANGLORE PATTERN TILES GALVALIUM SHEET ROOF OVER ROOF PUF SHEET ROOF AND RCC ROOF IN ZONE C UNDER AGE BR 1 AT INS SHIVAJI LONAVLA

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver3.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority: GE (I) (NAVY) Lonavla
Name of Work: REPAIRS TO MANGLORE PATTERN TILES, GALVALIUM SHEET, ROOF OVER ROOF, PUF SHEET ROOF AND RCC ROOF IN ZONE "C" UNDER AGE B/R-1 AT INS SHIVAJI LONAVLA (8361/E8)
Contract No: GE (I) (NAVY) L- of 2025-2026 Sl Page No -
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Rs. P Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With TaxesTOTAL AMOUNT In Words
12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455
1.00Completely removing existing water proofing treatment of any descriptions and any type including top layer of plaster / china mosiac wherever occurs over roof and chhajja surfaces scrubbing the surface with wire brush and cleaning wash down with water to receive new cement plaster / PCC layer and removing the waste material / debris to a distance exc. 1500m n.exc. 2000m etc complete all as specified and directed by Engineer-in-Charge 920.00Sqm0.00Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
2.00M/L for rendering 15mm thick in cm 1:4 on concrete roof and chajja surface to get a uniform level surface for laying of membrane treatment 920.00Sqm1.00Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
3.00M/L for PCC 1:2:4 type B-1 (using 20mm graded agg) for PCC padding on RCC roof surface finished even and smoother using extra cement all as specified and directed by Engineer-in-Charge36.80Cum2.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
4.00M/L for applying oil based bituminous primer @ 0.10 Kg/Sqm providing and laying 4mm thick. APP modified water proofing membrane weighing not less than 4kg/sqm re-inforced with non woven polyester matt weighing not less than 160 gm/sqm having softening point not less than 140 degree centigrade longitudinal tensile strength not less than 650 N/Sqm, tearing strength of 180N and with thermal insulation with the mineral / graved finish on upper side and laying with torches application and with 10 cm minimum lap in both direction length wise and width wise all as specified and directed by Engineer-in-Charge.920.00Sqm3.00Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
5.00M&L for Surface Preparation with complete removal of all loose and de-bonded concrete/ screed, loose particles, dirt & should be removed. Roof substrates must be pressure-washed with water with a minimum working pressure of 1,400 psi to be used to and/or remove all dirt, dust, chalking and waste products. Remove algae, mold by using bleach solution or biowash. 750.00Sqm4.00Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
6.00Complete removal of loose and damaged concrete roof screed in pockets with mechanical cutter. Clean the concrete screed with high pressure water jet to remove dirt and loose particles. Brush applies a bond coat of Dr. Fixit Pidicrete SBR mix in the ratio of 1:1 (URP 1: Cement 1) by volume to make it lump free slurry when applied on in the pre wet surface. Laid to fall roof screed in correct slope and gradient. Mix Dr. Fixit Pidicrete URP 10% by weight of cement in (M20) concrete in ratio of 1:1.5:3 i.e., one bag of 50kg cements: 1.5 times volume of sand: 3 times volume of aggregates: 25L water. Level the repair mortar and finish with trowel. Moist cure should be done for 7days. Air cure screed for 4-5 days, before application of roof topcoat coating system. 150.00Sqm5.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
7.00M & L for Crack Repair by cutting and widening all visible hairline cracks on concrete roof screed more than 0.50 mm and not giving hollow sound, should be cut and widen in V shape with mechanical cutter in the size (8mm W x 6mm D). Fill cracks with Dr. Fixit PU sealant / Hybrid Sealant with suitable gun and smoothed with a putty knife or trowel. Allow sealant to cure a minimum (72 Hrs.) 3 days. 75.00RM6.00Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
8.00M & L for Hacking and chipping the surface around the rainwater drain outlet up to 25mm in depth. Apply bond coat of Dr. Fixit Pidicrete URP in the ratio of 1:1 (URP 1: Cement 1) by volume over the corners and pipe insert outlet gaps. Filling the gaps around drain mouth with (PMM) polymer modified mortar mixed with Dr. Fixit Pidicrete URP 10% by weight of cement in the ratio of 1:3. Providing & fixing 100 mm width 225-gsm g/m2 Fiberglass Chopped Strand Mat around the periphery of drain mouth of rainwater outlet sandwiched with Dr. Fixit Wonderproof 100. Apply two thick coats of Dr. Fixit Wonderproof 100 waterproofing coating to completely cover the mesh/fabric and surrounding area. 15.00RM7.00Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
9.00M & L for Premix Dr. Fixit Wonderproof 100 Components A and B using an electric double-paddle mixer for 2–3 minutes at low speed. Apply the first coat of Dr. Fixit Wonderproof 100 at a rate of 0.80–0.90 kg/m² without dilution, using a lamb’s wool or cloth roller. While the coating is still wet, roll and embed a 225 gsm Fiberglass Chopped Strand Mat, ensuring full bonding without air bubbles or wrinkles. Allow the first coat to dry for 3–4 hours. Apply the second coat at a 90° angle to the first. Overlap the chopped strand mat by at least 5 cm at the joints, ensuring the overlaps are sufficiently wet to achieve proper bonding. Once the surface is dry enough to walk on, apply the second coat at 0.70–0.80 kg/m². Apply additional coats as needed to achieve a total dry film thickness of 900–1000 microns, with a total system material consumption of 1.50 - 1.60 kg/m² over 2–3 coats. Note – Coating should be terminated below the drip mould on the vertical surface. The material has followed technical properties: Attains a Tensile Strength ≥ 18 N/mm2 as per ASTM D 2370; Crack bridging ability, Tear Strength ≥ 160 N/mm as per ASTM D 624, Dynamic Crack bridging as per EN 13251:2016 - No Cracks after 20000 sinusoidal cycles, Dynamic Crack bridging as per ASTM C 1305-2016 - Pass, No Crack, Pass Low Temperature Flexibility (-20 after 1000 Hrs. UV as per ASTM D 1970-2021, Shore A as per ASTM D2240 – 85 , Peel Adhesion to Concrete under wet Condition -24 Hrs. – N As per ASTM C 794 – 11.4 , Abrasion resistance (CS 17 Wheel -1000 Cycle, 1.0 Kg) as per ASTM D 4060 - 7 mg , Depth of Water Permeability @ 10 Bar as per EN 12390-8-2019 – Nil , Water Migratlon Resistance as per ASTM D 7281,-2007 - No Leakage, Pass Spread of flame Class A. Complies with the requirements of EN 13251:2016 for a 25-year service life when used with a 225 gsm Fiberglass Chopped Strand Mat as fleece. The system comes with 10 Years’ waterproofing warranty from M/S Pidilite Industries LTD. For vertical surfaces and parapet walls should be enveloped & coated / painted with Dr. Fixit Raincoat Classic or Dr. Fixit Raincoat Select Waterproof coating system. 750.00Sqm8.00Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
10.00Disconnecting existing tanks of exc 500 n not exc 1000 capacity(in ltrs) , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after carrying out Roof treatment with all accessories all as specified and directed by Engineer-in-Charge21.00Each9.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
11.00Demolition of Reinforced cement Concrete water tanks of any size and any height over roof slab and making roof surface good including removing debris Outside of Mod land as directed by Engineer-in-Charge.5.00Cum10.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
12.00Removing demolished building materials unused soils etc to a distance of 100m but n exc. 5 km beyond the lead included in the rates, including loading, unloading and stacking at the destination 8.06Per Load11.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
13.00Dismantling mangalore pattern roofing tiles single layer including ridge tiles laid, bedded in cm complete all as specified and as directed by Engineer-in-Charge.135.00Sqm12.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
14.00M&L for mangalore pattern roof tiles inter locking at side and joints laid dry complete all as specified and as directed by Engineer-in-Charge.40.50Sqm13.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
15.00All as per item No 14 here-in-before but except tile complete all as specified and directed by Engineer-in-Charge.94.50Sqm14.00Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
16.00Dismantling battens for tiles any size exceeding 15cm in spacing complete all as specified and as directed by Engineer-in-Charge.126.90Sqm15.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
17.00Dismantling timber Scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed by Engineer-in-Charge.888.30RM16.00Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
18.00Dismantling timber Scantling 40 sqcm and over in section, in any position in framed work complete all as specified and as directed by Engineer-in-Charge.1.00Cum17.00Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
19.00S&F Tubular sections of size 50X25mm thick as in rafters fixed with self tapping screw of size not less than 75mm and 25X25 mm thick for battens fixed on rafters over CGI sheet roof with necessary fittings and welding for supporting mangalore pattern roof tiles complete (Fe 410-W, Grade-E-250 quality A)2700.00Kg18.00Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
20.00Dismantling of CGI/PGI /PUF sheet in roofing any gauge and any thickness including Nainital or similar pattern roof coverings including ridge, valley/gutter etc.229.90Sqm19.00Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
21.00S&F CGI sheeting 0.63 mm thick with two corrugation side lap fixed with L or J type bolts in roof walls etc with grade of zinc coating 275 gm/sqm complete all as specified and as directed by Engineer-in-Charge.36.80Sqm20.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
22.00All as per item No 21 here-in-before but except sheets complete all as specified and directed by Engineer-in-Charge.73.60Sqm21.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
23.00S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with L or J type bolt, grade of zinc coating 275 gm/sqm complete all as specified and as directed by Engineer-in-Charge.6.35Sqm22.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
24.00All as per item No 23 here-in-before but except sheets complete all as specified and directed by Engineer-in-Charge.10.15Sqm23.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
25.00Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles etc complete all as specified and directed by Engineer-in-Charge0.54Cum24.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
26.00M&L for Ridge or hip tiles to suit Mangalore pattern roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge135.00RM25.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
27.00All as per item No 26 here-in-before but except Ridge or hip tile complete all as specified and directed by Engineer-in-Charge.216.00RM26.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
28.00M&L for Filleting in any position and to any shape in cement mortar 1:6 sectional area exc 25 but n. exc 50 Sqcm complete all as specified and as directed by Engineer-in-Charge.351.00RM 27.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
29.00M&L For Closing bolt holes etc. in old corrugated steel sheets or Aluminium/Puf sheeting by sealing with one bitumen and one curved GI washer on either side and 6mm G.I. bolts and nuts,all set in stiff white lead, bolt n exc 25mm in length15.00PER 100 NOS.28.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
30.00M&L for prefabricated puf roofing panel with one side trapezodial sheet & other side plain sheet with slight rib of 0.40mm TCT PPGI (Off white RAL 9002) with 50mm core of polyurethene foam of density 40kg/M3 (+2Kg/M3) fixed with self tapping screws all as manufacturer's instructions including all cutting as required as per site conditions having following specifications complete all as specified and as directed by Engineer-in-Charge. (a) Top Sheet - Profile as approved by GE (b) Bottom sheet - Plain sheet with slight ribs (c) Panel thickness - 50mm (d) Facing material - 300 Mpa Galvalume steel with 150cms Aluminium Zinc (e) Facing material thickness - 0.5mm TCT (f) Facing material coating - DFT 20 microns colour coated Rmp/Smp/PVDF coating over 5 microns primer.72.10Sqm29.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
31.00S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall/Shed, fixed with self tapping screws all as specified and as directed by Engineer-in-Charge.20.60Sqm30.00Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
32.00S&F Pre painted galvalume aluminium zinc coating GI based plain sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified10.30Sqm31.00Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
33.00M&L for End Capping of Puff Pannel Roofing complete as as specified and as directed by Engineer-in-Charge.50.00Each32.00Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
Total in Figures0.00INR Zero Only4Construction of chamber for 100mm sluice platesitem510Nos
Quoted Rate in FiguresSelect0.00000.0000 Zero Only
Quoted Rate in WordsINR Zero Only