Items - SPECIAL REPAIR TO CONVERSION OF OLD ALUMINIUM WIRING WITH COPPER WIRING ALONG WITH REPAIR/REPLACEMENT OF FITTING/ FIXTURES IN MARRIED ACCN AND PROVISION OF HIGH MAST LIGHT AT ARTY CENTRE HYDERABAD UNDER GE GOLCONDA
BOQ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
BoQ_Ver3.0 | Item Rate | Normal | INR Only | INR | |||||||||||||||||||||||||||||||||||||||||||||||||||
Select, Excess (+), Less (-) | Less (-) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Tender Inviting Authority: GARRISON ENGINEER GOLCONDA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Name of Work: SPECIAL REPAIR TO CONVERSION OF OLD ALUMINIUM WIRING WITH COPPER WIRING ALONG WITH REPAIR/REPLACEMENT OF FITTING/FIXTURES IN MARRIED ACCN AND PROVISION OF HIGH MAST LIGHT AT ARTY CENTRE HYDERABAD UNDER GE GOLCONDA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Contract No: GE/GOL/ OF 2025-2026 SERIAL PAGE NO: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bidder Name : | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sl. No. | Description of work | Item Code / Make | No or Quantity | Units | Estimated Rate | Addition / Deduction | Addition / Deduction Values | Currency Convertion against each Item | Quoted Currency in INR / Other Currency | RATE In Figures To be entered by the Bidder including all Taxes Rs. P | Excise Duty | VAT | Freight Charges ( Unloading & Stacking) | Any Other Taxes/Duties/Levies | Other Taxes 2 | IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax | Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category | TOTAL AMOUNT | TOTAL AMOUNT With Taxes | TOTAL AMOUNT In Words | Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES | ||||||||||||||||||||||||||||||||||
1 | 2 | 3 | 3 | 4 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 5 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 | 51 | 52 | 7 | 6 | 7 | 56 |
1 | Taking down carefully existing point wiring of any description for (light, fan ,sockets bells etc) complete including fittings such as sunken boxes, switches, sockets, ceiling rose, lamp holders, brackets ,fittings, pendants, fan regulartors etc and making good the disturbed surface of walls, floors etc. complete all as specified and as directed. | 1348.00 | PER POINT | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
2 | Taking down existing sub main wiring /Service wire of any description and size including earth wire, batten, conduits and making good the disturbed surfaces of walls, floors etc.complete all as specified and as directed. | 843.00 | RUNNING METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
3 | M & L for providing point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including non metalic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed wiring on stone/brick, masonary walls, roof etc including modular sunken box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan /bell point controlled by one oneway modular switches including one run 1.5 sqmm (nominal area) PVC insulated FRLSH unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly including cutting/running chases, pinning in and making good the disturbed surfaces to match with the existing specification, complete all as specified & directed at site. Note : Cutting/running chases, pinning in shall be measured seperately for concealed point wiring ( One Concealed Point wiring shall be measured as 2.5 RM Cutting/running chases, pinning in complete all as specified and as directed. | 808.00 | PER POINT | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
4 | All as per Item No.4 above but one 5 Amps 3/5 pin modular socket outlet on independent board complete all as specified and as directed at site. | 194.00 | PER POINT | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
5 | All as per Item No.4 above but for one 3/5 pin 5/6 Amps modular socket outlet point on same board with other switches complete all as specified and as directed . | 194.00 | PER POINT | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
6 | All as per item No.4 but for One 3 pin 15 / 16 Amps modular switch socket outlet point on independent board with 2.5 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed . | 152.00 | PER POINT | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
7 | S&F in repair lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed . | 320.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
8 | S&F in repair Ceiling rose surface bakelite 65 x 50 mm 2/3 terminals complete all as specified and directed . | 488.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
9 | S&F in repair Modular switch, single pole, one way, 6 Amps one module complete all as specified and as directed. | 1196.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
10 | S&F in repair Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and as directed. | 388.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
11 | S&F in repair Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed. | 152.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
12 | S&F in repair Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed. | 152.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
13 | S&F in repair modular stepped type electronic fan regulator 220 volts, 100Watt complete all as specified and as directed. | 152.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
14 | S&F in repair modular bell push 6 Amps 1 module complete all as specified and as directed. | 42.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
15 | S&F in repair Factory made Prewired TPN 4 ways distribution board in sheet steel enclosure vertical double door with suitable rated bus bar, 240 Volts suitable for housing TPN MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed. | 12.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
16 | S&F in repair Factory made SPN 8 ways distribution board in sheet steel enclosure vertical double door with suitable rated bus bar, 240 Volts suitable for housing SPN MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed. | 42.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
17 | S&F in repair MCB, Four pole, 240 volts, 63 Amps 10 KA C curve complete all as specified and as directed. | 12.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
18 | Supply and fix RCBOs SPN 32 Amp, 240 volts 50Hz AC supply, complete all specified and directed. | 42.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
19 | S&F in repair 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed at site. | 396.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
20 | M&L for Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 6 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in and including PVC conduit medium grade/casing caping with all fittings suitable for concealed/surface type and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and directed . | 843.00 | RUNNING METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
21 | Supply and fix in repair 35W energy saving and environmental friendly long life LED building security street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08, 10KV surge protection and having 130 lumen/watt including connection with twin twisted unsheathed PVC copper cable of suitable size alongwith suitable brackets with clamps, nuts and bolts complete all as specified and directed. . | 42.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
22 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation, laying of poles, cables in trenches and getting out in hard/dense soil complete all as specified and as directed. | 206.00 | CUBIC METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
23 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as specified and as directed. | 110.00 | CUBIC METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
24 | Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as specified and as directed. | 96.00 | CUBIC METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
25 | Supply and spread approved dry river sand for cushioning of cable including watering and consolidation, laid in trenches complete all as specified and as directed. Note:- Punned thickness shall be measured for payment purpose | 91.35 | CUBIC METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
26 | M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and as directed. | 9.50 | 1000 Nos | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
27 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire rmoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of 35 Sqmm 3.5 core complete all as specified and as directed. | 1141.00 | RUNNING METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
28 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead complete all as specified and directed by the Engr-in-charge. | 15.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
29 | Supply and fix in repair LED lights fitting 1x 20W, 220V, AC decorative box type with powdered coated aluminium housing & integrated electronic driver with THD<10%, 4KV surge protection and 130 lumen/watt including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. | 194.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
30 | Supply and fix in repair LED lights fitting 1x 10W, 220V, AC decorative box type with powdered coated aluminium housing & integrated electronic driver with THD<10%, 4KV surge protection and 130 lumen/watt including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. | 42.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
31 | S&F in repair LED light fittings, 1x10 watts bulk head luminaires, IP66 complete with all accessories and including connecting up with twin core twisted flexible PVC copper conduct cabe of 23/0.0076 from ceiling rose all as specified. | 84.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
32 | S&F in repair bell ding dong AC single pole 230 volts complete all as specified and as directed . | 42.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
33 | S & F Power Unit for AC with one 25 Amps socket, (incl 3 pin plug Top 25 Amps) one electronic starter 25 Amps and one MCB SPN 25 Amps 'C' curve all accessories shall be fixed in one six module metal GI box, frame and cover plate and electrically connecting up complete all as specified and as directed. | 26.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
34 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 16 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen- ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed . | 820.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
35 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings steps, cills, sunshades, shelves, lintels,etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10 cm grith complete all as specified and directed. | 3383.00 | RUNNING METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
36 | S&F in repair 9 W LED bulb of base B22d with color temp 6500K complete all as specified and as directed. | 320.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
37 | Taking out defective winding and rewinding of the ceiling fan of any sweep complete with equivalent new super enamelled copper wire as per existing gauge and weight as per manufacturer's design and instructions including varnishing of ceiling fan of any make and any sweep complete all as specified and as directed. | 60.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
38 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store and including painting of ceiling fans complete, in situwith synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust and refixing of ceiling fan & connecting up including provision of cable from ceiling rose or connector to fan etc. complete all as specified and as directed. | 152.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
39 | Supply, Errection, Installation, Commissioning & testing of 16 Mtr height High Mast lightning system (Material construction of high mast sheet shall be of BSEN 10025 / lS 5986 Gr Fe 510 or equivatent). Mast shall be in two sections, hot dip galvanized and suitable for wind velocity as per IS 875 Part 3, bottom dia 410 mm OAF, Top dia 150 mm OAF, thickness of bottom/top sections are 4/3 mm respectively, Base plate of dia 650x25 mm with a PCD of 550 mm with its accessoriee, foundation bolts manufactured from special steel and hot dip galvanised along with nuts, washers, anchor plates and templates (One set of foundation accessories includes-012 Nos M30X850 fdn bolts with one anchor and template plate each of size 550 x 550 x 4 mm, the scope of work includes the following:- (a) Lantern carriage ring including arms with required size conforming to 750Kg load carrying capacity.(b) Double drum winch of 750 Kg capacity motor and manual method of operation tested load per drum 1000 Kgs.( c) Stainless steel wire rope 6 mm dia conforming to AISI-304/AISI-316 grade. (d) Power tool 1.5 HP 1400 RPM single speed Reversible 415 Volt.(e) Foundation of High Mast in M 20 Concrete grade design mix including excavation/earth work complete all as specified and as directed. Note : - (i) Work to be executed as per standard engineering practices and as per manufacturers instruction. (ii) Before placing the order the design/ drawing of high mast of the manufacturer shall be got approved by GE. (iii) Work to be executed by the manufacturer or there authhorized rep. (iv) Size/type of RCC foundation Shall be carried out as per manufacturers drawings. (v) Any item missed out above but is technically required for safe and proper installation and operation of High Mast shall be deemed to be included in the quoted rate. | 1.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
40 | Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. complete all as specified and as directed. | 9.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
41 | S & F nature switch pole mounted encloser consisting of NATURE SWITCH-02, power contactor for load switching, MCB, and terminal blocks. The enclosure with mounting brackets, cable glands, openable door with lock and key arrangement. The enclosure is made of UV stabilized, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor. Selectable options are available for duration based switching OFF suitable for 3 KW load, three phase operation, 415 Volts, 50 Hz, AC, with all connected accessories, including taking down existing timer switch, complete all as specified and as directed. | 1.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
42 | Supply, install, test and commission CPRI APPROVED factory fabricated, outdoor type, LT FEEDER PILLAR BOX made out of 3.15mm thick CRCA sheet of size 1M x 0.75M x 0.35M with projected globe roof for rainwater protection dust and vermin proof, double door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc cromium plated nuts, bolts and washers etc. and embeded with 50x50x6mm MS angle iron frame, 600mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:3:6 (20mm graded stone aggregate) complete all as specified and comprising of the following :- (a) Aluminium busbar 200 amps - 04 Nos, supported on suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 100 amps, 415 volt, 25 KA breaking capacity 4 pole electromagnetic release duly connected to busbar as incoming - 01 No. | 1.00 | EACH JOB | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
43 | S & F 6 W LED Aviation obstruction light yellow painted die cast aluminum alloy housing built in heat resistant clear thick glass and accessories LED typ Aviation obstruction light suitable to operate in230V single phase AC supply complete on the Overhad reservoir complete all as specified and as directed. | 2.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
44 | Supply, laying & testing XLPE insulated screened , PVC bedded, galvanised steel strip or wire armoured , electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 2 core 10 sqmm complete all as specified and as directed. | 30.00 | RUNNING METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
45 | Chemical earthing with copper earth plate 90x60cmx5mm & copper earth strip 32x6mm Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised earth strip 32x6mm upto test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel wire mesh and medium grade GI wire protection pipe 40mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and as directed. Note:- The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. | 1.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
46 | M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32 x 6 mm by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point including necessary earth work and excavation, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia light grade all as specified and directed. Note: Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. | 3.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
47 | Supplying and fixing aluminium strip 25 x 4 mm with sadles and fixing screws etc roof conductors and down conductors above grounnd | 25.00 | RUNNING METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
48 | S & F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required Copper strip 32 x 6 mm dia galvanised iron or steel wire | 21.00 | RUNNING METRE | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
Total in Figures | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Figures | Select | 0.0000 | 0.0000 | Zero Only | |||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Words | INR Zero Only |
Andaman & Nicobar Tenders |Andhra Pradesh Tenders |Arunachal Pradesh Tenders |Assam Tenders |Bihar Tenders |Chandigarh Tenders |Chhattisgarh Tenders |Dadra & Nagar Haveli Tenders |Daman & Diu Tenders |Delhi Tenders |Goa Tenders |Gujarat Tenders |Haryana Tenders |Himachal Pradesh Tenders |Jammu & Kashmir Tenders |Jharkhand Tenders |Karnataka Tenders |Kerala Tenders |Ladakh Tenders |Lakshadweep Tenders |Madhya Pradesh Tenders |Maharashtra Tenders |Manipur Tenders |Meghalaya Tenders |Mizoram Tenders |Nagaland Tenders |Odisha Tenders |Pondicherry Tenders |Punjab Tenders |Rajasthan Tenders |Sikkim Tenders |Tamil Nadu Tenders |Telangana Tenders |Tripura Tenders |Uttarakhand Tenders |Uttar Pradesh Tenders |West Bengal Tenders |