Items - PROVN OF MD ACCN (PHASE-II OF TWO PHASES) AT MISSAMARI UNDER GE MISSAMARI
BoQ | BOQ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BoQ_Ver3.0 | Item Rate | Normal | INR Only | INR | |||||||||||||||||||||||||||||||||||||||||||||||||||
Select, Excess (+), Less (-) | Less (-) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Tender Inviting Authority : CHIEF ENGINEER SILIGURI ZONE | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
NAME OF WORK : PROVN OF MD ACCN (PHASE-II OF TWO PHASES) AT MISSAMARI UNDER GE MISSAMARI | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Contract No : CESZ/MISM/ OF 2025-2026 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bidder Name : | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sl. No. | Item Description | Item Code / Make | Qty. | Units | Pre Priced Unit Rate (in. Rs.) as Defined by MES | Addition / Deduction | Addition / Deduction Values | Currency Convertion against each Item | Quoted Currency in INR / Other Currency | RATE In Figures To be entered by the Bidder Rs. P | Excise Duty | VAT | Freight Charges ( Unloading & Stacking) | Any Other Taxes/Duties/Levies | Other Taxes 2 | IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax | Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category | TOTAL AMOUNT (In INR) | TOTAL AMOUNT With Taxes | TOTAL AMOUNT In Words | Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES | ||||||||||||||||||||||||||||||||||
1 | 2 | 3 | 3 | 4 | 5 | 7 | 8 | 9 | 10 | 11 | 12 | 6 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 | 51 | 52 | 7 | 54 | 8 | 9 |
1.00 | BUILDINGS & STRUCTURE (Sch 'A' PART-I) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.01 | Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 74,52,62,000.00 inserted by the MES in Schedule ‘A’ Part-I. | 1.00 | LUMP SUM | 745,262,000.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
2.00 | EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
2.01 | Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 28,49,260.75 inserted by the MES in Schedule ‘A’ Part-II. | 1.00 | LUMP SUM | 2,849,260.75 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
3.00 | INTERNAL WATER SUPPLY (Sch 'A' PART-III) | Excess(+) | 1 | Full Conversion | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
3.01 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 71,18,938.87 inserted by the MES in Schedule ‘A’ Part-III. | 1.00 | LUMP SUM | 7,118,938.87 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
4.00 | INTERNAL ELECTRIFICATION (Sch 'A' PART-IV) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
4.01 | Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,49,56,065.19 inserted by the MES in Schedule ‘A’ Part-IV. | 1.00 | LUMP SUM | 14,956,065.19 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
5.00 | ROAD, PATH, CULVERT & HARDSTANDING (Sch 'A' PART-V) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
5.01 | Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,38,42,648.76 inserted by the MES in Schedule ‘A’ Part-V. | 1.00 | LUMP SUM | 13,842,648.76 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
6.00 | SEWAGE DISPOSAL (Sch 'A' PART-VI) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
6.01 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 13,37,061.19 inserted by the MES in Schedule ‘A’ Part-VI. | 1.00 | LUMP SUM | 1,337,061.19 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
7.00 | AREA DRAINAGE (Sch 'A' Part-VII) | Excess(+) | 1 | Full Conversion | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
7.01 | Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 10,11,438.72 inserted by the MES in Schedule ‘A’ Part-VII. | 1.00 | LUMP SUM | 1,011,438.72 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
8.00 | SECURITY WALL, FENCING AND GATE (Sch 'A' Part-VIII) | Excess(+) | 1 | Full Conversion | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
8.01 | Lump sum price worked out by the Contractor for “(SECURITY WALL, FENCING AND GATE)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs.74,60,570.29 inserted by the MES in Schedule ‘A’ Part-VIII. | 1.00 | LUMP SUM | 7,460,570.29 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
9.00 | EXTERNAL WATER SUPPLY (Sch 'A' Part-IX) | Excess(+) | 1 | Full Conversion | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
9.01 | Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,29,600.28 inserted by the MES in Schedule ‘A’ Part-IX. | 1.00 | LUMP SUM | 429,600.28 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
10.00 | EXTERNAL ELECTRIFICATION (Sch 'A' PART-X) | Excess(+) | 1 | Full Conversion | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
10.01 | Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs.21,21,549.60 inserted by the MES in Schedule ‘A’ Part-X. | 1.00 | LUMP SUM | 2,121,549.60 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
11.00 | LIFT (Sch 'A' Part-XI) | Excess(+) | 1 | Full Conversion | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
11.01 | Lump sum price worked out by the Contractor for “(LIFT)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,91,51,569.40 inserted by the MES in Schedule ‘A’ Part-XI. | 1.00 | LUMP SUM | 29,151,569.40 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
12.00 | SOLAR HOT WATER SUPPLY (Sch 'A' Part-XII) | Excess(+) | 1 | Full Conversion | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
12.01 | Lump sum price worked out by the Contractor for “(SOLAR HOT WATER SUPPLY) ” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 39,52,937.95 inserted by the MES in Schedule ‘A’ Part-XII. | 1.00 | LUMP SUM | 3,952,937.95 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
13.00 | FIRE FIGHTING (Sch 'A' Part-XIII) | Excess(+) | 1 | Full Conversion | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
13.01 | Lump sum price worked out by the Contractor for “(FIRE FIGHTING)” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 17,51,422.20 inserted by the MES in Schedule ‘A’ Part-XIII. | 1.00 | LUMP SUM | 1,751,422.20 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
14.00 | LIGHTNING PROTECTION (Sch 'A' Part-XIV) | Excess(+) | 1 | Full Conversion | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
14.01 | Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION)” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 7,69,830.50 inserted by the MES in Schedule ‘A’ Part-XIV. | 1.00 | LUMP SUM | 769,830.50 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | -100 | |||||||||||||||||||||||||||||||||||||||||||
15.00 | MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XV) | Excess(+) | 1 | Full Conversion | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
15.01 | EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT Bringing approved Earth may be mixed with granules / pebbles not exceeding 40 mm size (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any, transportation, taxes if any etc. complete all as specified and directed. NOTE :- (a) Earth required for the item shall be supplied by contractor from outside of MOD land at any lead, at his own arrangement. (b) All cost of procurement of earth including cost of transportation, compaction royalties, tax etc shall be deemed to be included in the unit rate quoted by the contractor. (c) Forming embankments / filling in low lying areas including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering ramming / rolling and finishing of required size, shape etc not exceeding 1.5 m high from base / natural ground level. (d) With reference to Clause 3.6 of MES Schedule Part-II on Serial Page No. 21, it is clarified that measurement of the above item shall be of finished embankment / traverse of filled earth after consolidation / compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk. (e) Total quantity / partial quantity of earth may not be available in Missamari Area. The contractor shall bring the earth outside area and it is advised to quote the rate considering available of soil and its lead involved. | 799.36 | CUM | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.02 | INTERNAL ELECTRIFICATION M& L for modular type, 3/5 pin socket outlet including plug top 16 A controlled by by Switch 16 A including sheet metal enclosure suitable for Geyser point complete all as specified and directed. | 120.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.03 | S&F of Modular type TV Co-axial socket outlet-1 Module in the modular MS / GI sheet box and cover plate including concealed 25 mm PVC conduit in wall / ceiling / fixed to roof, connections etc complete all as specified and as directed. | 192.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.04 | S&F of Modular type RJ-11 telephone socket outlet in the modular MS/GI sheet box and cover plate including concealed 25 mm PVC conduit in wall / ceiling / fixed to roof, connections etc complete all as specified and as directed. | 48.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.05 | S&F 5 watt LED lamp capable to output 501 lm with lamp holder B22 type complete all as specified and directed. | 894.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.06 | S&F Wall Mounted Fan, AC, Single Phase, 230 V of size 400 mm sweep complete all as specified and directed. | 24.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.07 | S&F TPN 6 Way (Vertical Type), double door, metallic distribution board, conforming to IEC 61439-3, suitable for flush / surface mounting with provision of FP RCCB / RCBO / MCCB as incomer and SP / TPN MCBs as outgoing, reversible metal door, 100 A copper busbar fully shrouded neutral bar, earth bar, wire set and cable tiles for cable management pre fitted masking sheet, etc having K-09 & IP-43 protection complete all as specified and directed. | 6.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.08 | S&F SPN DB with sheet metal enclosure 240 Volts, 6 Way, Single Phase, Double Door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as specified and directed. | 8.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.09 | S&F Hot press molded SMC meter box of size not less than 700mm X 480mm x 210mm for accommodating 04 nos of single/three phase prepaid energy meter including cutting the wall surfaces for flush mounting of meter box and making good to match with the existing surface complete all as specified and directed. | 24.00 | EACH JOB | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.10 | ROAD, PATH, CULVERT & HARDSTANDING M&L for reflective thermoplast white / yellow road marking paint laid down through road marking machine in layers of 3.00 mm thick crystlese and use of 5 kg per sqm by incorporating the white glass beads @ 300 gms per Sqm for reflecting including cleaning of surfaces complete all as specified and directed. | 52.25 | SQM | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.11 | Supply and installation of Raised Pavement Marker (RPM) with polycarbonate lens electronically welded with the RPM body. The marker shall be scratch proof and abrasion resistant microprismatic polycarbonate lens with polycarbonate reflective panels with dual prismatic cubes capable providing total internal reflection. Dimention : The dimension of the marker is heght 15.88 mm, width 101.6mm, length 89.2 mm. The marker conforms to ASTM D4280 and is in accordance with MOSRTH circular reference No. RW/NH 33023/10/97-DO III dated 11 Jun 1997. Marker shall be fixed with adhesive and no nails shall be used to affix the marker and shall be marked with manufacturer name complete all as specified and directed. | 138.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.12 | SEWAGE DISPOSAL Supply, laying and testing of 200mm internal dia of DWC high density (HDPE) pipe (ISI marked) (with CM/L No) with and including all fittings and jointing materials for sewage line and laid in trenches complete all as specified and directed. | 500.00 | RM | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.13 | EXTERNAL WATER SUPPLY Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 100 mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification class K-7 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. MAKE : Electrosteel casting ltd or equivalant Make of Tata/Jindal. NOTE : (a) Excavation and DI Specials shall be measured and paid separately . (b) Rate of rubber gasket is deemed to be included in unit quoted ratel. | 60.00 | RM | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.14 | M&L for construction Brick Masonary valve pit of size 900x900x900 mm (internal dimention) one each brick thick wall in cement mortar 1:4 on 100 mm thick PCC (1:4:8) (using 40mm graded crushed stone aggregate) in job foundation, renderring 15mm thick internally and externally upto 150mm below GL, providing 3.15 mm thich MS Sheet valve pit cover , welded with 40x5mm flat iron frame all round including provision of hinges, handle with locking arrangement and 40x40x6 mm angle iron frame fixed on top of value pit by means of hold fast 150mm long, embedd-ed in PCC (1:2:4) (using 20 mm graded crushed stone aggregate) block of size 230x200x100mm applying two coats of anti- corrosive paint to all expossed steel surface over acoat of red oxide zinc chrome primer after preparation of surfaces and necessay earth work in soaft/ loose soil includinding demolition of unserviceable value pit, complete all as specified and directed. | 4.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.15 | EXTERNAL ELECTRIFICATION M&L for boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exceeding 150 mm bore for passing of pipes, complete all as specified and directed. | 100.00 | RM | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.16 | Outdoor type LT Panel of suitable size CPRI approved factory made OPENABLE from both side panel board complete with internal wiring the following items housed in :- LT PANEL-02 for Offrs Md Accn (a) 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incommer - MCCB 4 pole, 400 Amps, breaking capacity 36 kA Make - Indoasian, Cat No. 830396 - 01 Nos (c) Outgoing - MCCB 4 pole, 40 Amps, breaking capacity 25 kA Make - Indoasian, Cat No. 830268 - 01 Nos (d) Outgoing - MCCB 4 pole, 63 Amps, breaking capacity 25 kA Make - Indoasian, Cat No. 830270 - 06 Nos + Spare (e)Three Ph Digital Volt Meter (0-500)Volt with selector switch. Make - L&T, Cat No. LL132020OOOO- 01Nos (f) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch. Make - L&T, Cat No. LL131020OOOO - 01 Nos (g) Digital frequency meter 40-60 Hz - 01 L&T No. Model:- WL113040OOOO-01 Nos (h) Copper wound with CTR 160/5,100/5,01 Each Set (j) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (k) PCC Foundation B-2, (1:2:4). | 1.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.17 | Outdoor type LT Panel of suitable size CPRI approved factory made OPENABLE from both side panel board complete with internal wiring the following items housed in :- Panel for Lift and Terrace Pump -02 No for Block-II of Offrs MD Accn (a) 200 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incommer - MCCB 4 pole, 63 Amps, breaking capacity 25 kA Make - Indoasian, Cat No. 830270 - 01 Nos (c) Outgoing - MCCB 4 pole, 40 Amps, breaking capacity 25 kA Make - Indoasian, Cat No. 830268 - 03 Nos + Spare (d) Outgoing- Automatic star delta starter suitable for 415 V of Cap 15HP for terrace pump, -01 Nos (e)Three Ph Digital Volt Meter(0-500)Volt with selector switch. Make - L&T, Cat No. LL132020OOOO- 01Nos (f) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch. Make - L&T, Cat No. LL131020OOOO - 01 Nos (g) Digital frequency meter 40-60 Hz - 01 L&T No. Model:- WL113040OOOO-01 Nos. (h) Copper wound with CTR 160/5,100/5,01 Each Set (j) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (k) BLANK (l) PCC Foundation B-2, (1:2:4). | 1.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.18 | Outdoor type LT Panel of suitable size CPRI approved factory made OPENABLE from both side panel board complete with internal wiring the following items housed in :- LT Panel-02 for Block -II of JCOs Accn (a) 200 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incommer- MCCB 4 pole, 160 Amps, breaking capacity 36 kA Make - Indoasian, Cat No. 830334 - 01 Nos (c) Outgoing - MCCB 4 pole, 40 Amps, breaking capacity 25 kA Make - Indoasian, Cat No. 830268 - 07 Nos + Spare (d)Three Ph Digital Volt Meter(0-500)Volt with selector switch. Make - L&T, Cat No. LL132020OOOO- 01Nos (e) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch. Make - L&T, Cat No. LL131020OOOO - 01 Nos (f) Digital frequency meter 40-60 Hz - 01 L&T No. Model:- WL113040OOOO-01 Nos. (g) Copper wound with CTR 160/5,100/5,01 Set (h) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (j) PCC Foundation B-2, (1:2:4). | 1.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.19 | Outdoor type LT Panel of suitable size CPRI approved factory made OPENABLE from both side panel board complete with internal wiring the following items housed in :- LT Panel for Block -II of ORs Accn (a) 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incommer- MCCB 4 pole, 250 Amps, breaking capacity 36 kA Make - Indoasian, Cat No. 830336 - 01 Nos (c) Outgoing - MCCB 4 pole, 63 Amps, breaking capacity 25 kA Make - Indoasian, Cat No. 830270 - 06 Nos + Spare (d) Outgoing - MCCB 4 pole, 40 Amps, breaking capacity 25 kA Make - Indoasian, Cat No. 830268 - 01 Nos (e)Three Ph Digital Volt Meter(0-500)Volt with selector switch. Make - L&T, Cat No. LL132020OOOO- 01Nos (f) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch. Make - L&T, Cat No. LL131020OOOO - 01 Nos (g) Digital frequency meter 40-60 Hz - 01 L&T No. Model:- WL113040OOOO-01 Nos. (h) Copper wound with CTR 160/5,100/5,01 Set (j) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (k) PCC Foundation B-2, (1:2:4). | 1.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.20 | Outdoor type LT Panel of suitable size CPRI approved factory made OPENABLE from both side panel board complete with internal wiring the following items housed in :- Panel for Lift and Terrace Pump -01 No for Block-II of JCOs MD Accn (a) 200 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incommer - MCCB 4 pole, 63 Amps, breaking capacity 25 kA Make - Indoasian, Cat No. 830270 - 01 Nos (c) Outgoing - MCCB 4 pole, 40 Amps, breaking capacity 25 kA Make - Indoasian, Cat No. 830268 - 03 Nos + Spare (d) Outgoing- Automatic star delta starter suitable for 415 V of Cap 15HP for terrace pump, -01 Nos (e)Three Ph Digital Volt Meter(0-500)Volt with selector switch. Make - L&T, Cat No. LL132020OOOO- 01Nos (f) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch. Make - L&T, Cat No. LL131020OOOO - 01 Nos (g) Digital frequency meter 40-60 Hz - 01 L&T No. Model:- WL113040OOOO-01 Nos. (h) Copper wound with CTR 160/5,100/5,01 Set (j) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (k) PCC Foundation B-2, (1:2:4). | 1.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.21 | Outdoor type LT Panel of suitable size CPRI approved factory made OPENABLE from both side panel board complete with internal wiring the following items housed in :- Panel for Lift and Terrace Pump for Block-IIof ORs MD Accn (a) 200 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incommer - MCCB 4 pole, 100 Amps, breaking capacity 25 kA Make - Indoasian, Cat No.830272 - 01 Nos (c) Outgoing - MCCB 4 pole, 40 Amps, breaking capacity 25 kA Make - Indoasian, Cat No.830268 - 05 Nos + 01 Spare (d) Outgoing- Automatic star delta starter suitable for 415 V of Cap 15HP for terrace pump, -01 Nos (e)Three Ph Digital Volt Meter(0-500)Volt with selector switch. Make - L&T, Cat No. LL132020OOOO- 01Nos (f) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch. Make - L&T, Cat No. LL131020OOOO - 01 Nos (g) Digital frequency meter 40-60 Hz - 01 L&T No. Model:- WL113040OOOO-01 Nos. (h) Copper wound with CTR 160/5,100/5,01 Set (j) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (k) PCC Foundation B-2, (1:2:4). | 1.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.22 | Supply, installation, connecting and testing of high mast lighting system comprising with 16 mtr high galvanised mast (in two part) having thickness top to bottom 3 mm, circular frame (made of galvanised iron rolled section) including provision of 9 Nos integral 200 Watt LED Flood light with advanced optical system duly pre wired including provisioning of 3 runs of PVC insulated, un sheathed copper cable 1100 volts grade having two point suspension system with steel rope of 8 mm dia double drum winch suitable for both electrically and manually operation including control panel (comprising contactor, MCB and timer switch of suitable size), connecting copper cable (flexible) of size 5 core x 2.5 sqmm of required length with necessary excavation for earth work, PCC foundation of PCC 1:3:6 as per requirement with suitable size of nuts & bolts as per manufacturer specification including lighting arresters, earthing, LT control panel and LED aviation obstruction light complete all as specified and directed. | 3.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.23 | SOLAR WATER HEATER S & F 3 layer PP-R pipe of 25mm dia, SDR 7.4 PN-16 and UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches or fixed on wall incl all accessories like tees, bends, sockets, union etc complete all as specified and directed. | 350.00 | RM | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.24 | FIRE FIGHTING S&F Fire Extinguisher dry chemical powder (ABC) type 6 Kg capacity confirming to IS 15683 complete all as specified and directed. | 48.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.25 | S&F Fire Extinguisher CO2 type (light weight squeezed grip type) 4.5 Kg capacity confirming to IS 15683 complete all as specified and directed. | 48.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.26 | S&F Fire Extinguisher water stored pressure type 9 Ltr capacity confirming to IS 15683 complete all as specified and directed. | 42.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.27 | S&F Fire Extinguisher mechanical foam type 9 Ltr capacity confirming to IS 15683 complete all as specified and directed. | 12.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.28 | S&F fire hydrant landing valve type B (single head outlet) of 63 mm dia conforming to IS 5290 complete all as specified and directed. | 42.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.29 | S&F hose reel of 20 mm dia and 30 meter length conforming to IS 5132 complete all as specified and directed. | 42.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.30 | S&F electric motor siren conforming to IS 1941 suitable for three phase 415 V supply with motor not exceeding 3.75 KW power and able to deliver 143 DB noise level complete all as specified and directed. | 3.00 | EACH SET | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.31 | S&F MS flanged pipe 100 mm NB heavy duty for multi storied bldg duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and directed. | 150.00 | RM | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.32 | Supply, fixing, testing and commissioning pressure switch universal type complete all as specified and directed. | 6.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.33 | S&F Cast Iron Air Valves with two air Outlets, 100 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed. | 6.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.34 | Supply and Installation of Booster pump for Terrace Pump up to 30 meter head discharge 900 LPM complete all as specified and directed. | 6.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.35 | S&F Valve, reflux, with by-pass Arrangement, 100 mm (4”) diacomplete all as specified and directed. | 6.00 | EACH | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.36 | Supply, laying & testing of PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sqmm, 2 core, 1100 volts grade complete all as specified and directed. | 1000.00 | RM | 0.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.37 | COMPREHENSIVE MAINTENANCE OF LIFT | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
15.38 | Provision of services by deploying Lift Technician (Skilled) [ITI qualified with sufficient experience in day to day maintenance and emergency rescue operation for 03 Nos. Lifts, 8 passenger (3 x 8 passenger lift), 04 Nos. Lift, 13 passenger (4 x 13 passenger lift) and 03 Nos. Lifts 20 passenger (3 x 20 passenger lift) electrically operated Lifts of any capacity, type and make at Md Accn Missamari to serve any number of floors for Bldg (1x Offr’s, 1x JCO's, 1x OR's) in required Shift on all the days for eleven months including Sunday & Holidays including taking care of from any pilferage, theft or damage etc to ensure smooth and trouble free operation of Lifts to the entire satisfaction of users/ department, complete all as specified and as directed. Shift details:- (a) 01 lift technicians for Offr’s Complex (1 x 20 passenger lift, 1 x 13 passenger lift and 1 x 8 passenger lift) x 2 Shift. (b) 01 lift technicians for another JCO’s Complex (1 x 20 passenger lift, 1 x 13 passenger lift and 1 x 8 passenger lift) x 2 Shift. (c) 01 lift technicians /each OR’s Complex (1 x 20 passenger lift, 2 x 13 passenger lift and 1 x 8 passenger lift) x 2 Shift. 1 x 2 Shift at night, 1 Shift for Offr’s, JCO’s & OR’s Complex 1 Shift Total Nos of Shift per day : 08 Shift/day for 10 lifts. Item Continued as 15.39 | 11.00 | PER MONTH | 338,536.00 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.39 | NOTE:- (a) The quoted rate only include for one Lift technician for each shift deployed by contractor during defect liability period. (b) Comprehensive maintenance of Lifts shall be done by OEM only. (c) Contractor shall ensure and comply with minimum wages and other statutary charges all as applicable as per Govt Orders. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
15.40 | All as per Srl Item No. 15.38 & 15.39 here-in-above but for next eleven months from the next day after completion of 11 months. | 11.00 | PER MONTH | 353,254.95 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.41 | All as per Srl Item No. 15.38 & 15.39 here-in-above but for next two months from the next day after completion of 22 months. | 2.00 | PER MONTH | 353,254.95 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.42 | Comprehensive Maintenance of 03 Nos. Lifts, 8 passenger (3 x 8 passenger lift), 04 Nos. Lift, 13 passenger (4 x 13 passenger lift) and 03 Nos. Lifts 20 passenger (3 x 20 passenger lift) electrically operated Lifts of any capacity, type and make at Md Accn Missamari to serve any number of floors by providing services of Lift Technician (Skilled) (ITI qualified with sufficient experience in day to day maintenance and emergency rescue operation) for Bldg (1x Offr’s, 1x JCO's, 1x OR's) in required Shift on all the days for eleven months including Sunday & Holidays including taking care of from any pilferage, theft or damage etc to ensure smooth and trouble free operation of Lifts to the entire satisfaction of users/ department, complete all as specified and as directed. Shift details:- (a) 01 lift technicians for Offr’s Complex (1 x 20 passenger lift, 1 x 13 passenger lift and 1 x 8 passenger lift) x 2 Shift. (b) 01 lift technicians for another JCO’s Complex (1 x 20 passenger lift, 1 x 13 passenger lift and 1 x 8 passenger lift) x 2 Shift. (c) 01 lift technicians /each OR’s Complex (1 x 20 passenger lift, 2 x 13 passenger lift and 1 x 8 passenger lift) x 2 Shift. 1 x 2 Shift at night, 1 Shift for Offr’s, JCO’s & OR’s Complex 1 Shift Total Nos of Shift per day : 08 Shift/day for 10 lifts. Item Continued as 15.39 | 11.00 | PER MONTH | 367,973.91 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.43 | NOTE:- (a) The quoted rate only include for one Lift technician for each shift deployed by contractor. Comprehensive maint of all lifts shall be carried out by contractor without any additional cost to the department after completion of defect liability period of 02 years. (b) Comprehensive maintenance of Lifts shall be done by OEM only. (c) Contractor shall ensure and comply with minimum wages and other statutary charges all as applicable as per Govt Orders. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
15.44 | All as per Srl Item No. 15.42 & 15.43 here-in-above but for next eleven months from the next day after completion of 35 months. | 11.00 | PER MONTH | 382,692.87 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.45 | All as per Srl Item No. 15.42 & 15.43 here-in-above but for next eleven months from the next day after completion of 46 months. | 11.00 | PER MONTH | 397,411.82 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.46 | All as per Srl Item No. 15.42 & 15.43 here-in-above but for next three months from the next day after completion of 57 months. | 3.00 | PER MONTH | 397,411.82 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.47 | NOTE FOR SRL ITEM Nos. 15.42 to 15.46 :- (a) All minor parts like nut, bolts, grease, cotton waste, lubricant oil etc. shall be deemed included in this quoted rate. (b) All necessary T&P required on site shall be provided by contractor without any extra cost. (c) Major parts other than above as recommended by OEM shall be supplied by the department as and when required, however fixing charges of same be include in above quoted rate. (d) Comprehensive maintenance shall be done OEM only. (e) Comprehensive maintenance for 03 years after Defect Liability Period shall be carried out by contractor only. The quoted rated is deemed to be inclusive of comprehensive maintenance. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
15.48 | NOTE FOR SRL ITEM No. 15.38 to 15.46 The bidders shall ensure that the quoted amount for M & O is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount. Amount so adjusted will be deducted from quoted amount against Sch 'A' Part-I i.e. Item No. 1.01 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
15.49 | Annual Testing of lift by lift inspector of the State of Assam (once in a Year) of any type of lift and submit the test certificate to the department shall be done by contractor | 40.00 | EACH JOB | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
15.50 | Supply only Control Fuses (Glass Type 2A) electronic components complete all as specified and as directed. | 40.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
15.51 | Supply only Push Buttons of any type complete all as specified and as directed. | 35.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
15.52 | Supply only Rollers of any type complete all as specified and as directed. | 35.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
15.53 | Supply only Guide Shoes any type complete all as specified and as directed. | 18.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
15.54 | Supply only ARD Battery 7AH complete all as specified and as directed. | 34.00 | EACH | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
15.55 | M & L for any welding machine work lathe work etc complete all as specified and directed. | 11.00 | EACH JOB | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||
Total in Figures | 0.00 | 0.00 | INR Zero Only | 4 | Construction of chamber for 100mm sluice plates | item5 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Figures | Select | 0.0000 | 0.0000 | Zero Only | |||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Words | INR Zero Only |
Andaman & Nicobar Tenders |Andhra Pradesh Tenders |Arunachal Pradesh Tenders |Assam Tenders |Bihar Tenders |Chandigarh Tenders |Chhattisgarh Tenders |Dadra & Nagar Haveli Tenders |Daman & Diu Tenders |Delhi Tenders |Goa Tenders |Gujarat Tenders |Haryana Tenders |Himachal Pradesh Tenders |Jammu & Kashmir Tenders |Jharkhand Tenders |Karnataka Tenders |Kerala Tenders |Ladakh Tenders |Lakshadweep Tenders |Madhya Pradesh Tenders |Maharashtra Tenders |Manipur Tenders |Meghalaya Tenders |Mizoram Tenders |Nagaland Tenders |Odisha Tenders |Pondicherry Tenders |Punjab Tenders |Rajasthan Tenders |Sikkim Tenders |Tamil Nadu Tenders |Telangana Tenders |Tripura Tenders |Uttarakhand Tenders |Uttar Pradesh Tenders |West Bengal Tenders |