Bidhelp
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE SC AND CE PUNE ZONE - MES||CWE (ARMY) MUMBAI - MES
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE SC AND CE PUNE ZONE - MES||CWE (ARMY) MUMBAI - MES
Shri Vinay Kumar, IDSE, SE (SAG), CWE
Maharashtra QTY :

Items - MAINTENANCE AND UPKEEP OF HT DISTRIBUTION SYSTEM TRANSFORMER AND ALLIED WORKS UNDER GE NORTH SANTACRUZ MUMBAI

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver3.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority: CWE (Army) Mumbai
NAME OF WORK : MAINTENANCE AND UPKEEP OF HT DISTRIBUTION SYSTEM, TRANSFORMER AND ALLIED WORKS UNDER GE (NORTH) SANTACRUZ MUMBAI
Contract No: CWE (M)/ OF 2025-26
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Conversion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Rs. P Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2III rd Party i.e. DGS&D / RITES etc. Inspection Charges @0.34%+Service TaxLess for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without TaxesTOTAL AMOUNT With TaxesTOTAL AMOUNT In Words
12334578910111251415161718192021222324252627282930313233343536373839404142434445464748495051525369
1Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for laying UG cables and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge138.78CumExcess(+)1Full ConversionINR0.000.00INR Zero Only
2Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any soil all as specified and as directed by Engineer-in-Charge.84.95CumExcess(+)1Full ConversionINR0.000.00INR Zero Only
3Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge53.82Each SetExcess(+)1Full ConversionINR0.000.00INR Zero Only
4Material and labour for crushed sand filling in trenches for cable crushioning below and above the cable complete all as specified and directed by Eng- in -charge.40.82CumExcess(+)1Full ConversionINR0.000.00INR Zero Only
5Supply & laying un -inforced pre cast concrete with flat cover Factory made Class HV, type 1, size 300x180x40 mm complete all as specified and directed by Eng- in -charge.400.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
6Supply & laying un -inforced pre cast concrete cable cover LV type flat size, class type I 250x150x40 mm complete all as specified and directed by Eng- in -charge.2880.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
7M & L for disconnecting the HT & LT supply of capacity 150 to 750 KVA 11KV/ 0.433 KV transformer, draining out complete insulating oil from transformer kept on plinth including removing transformer top cover, explosion vent pipe and lifting the core from the shell/ tank , wash/ cleaning the core winding, internal surface of shell container with clean dry oil by flushing out by means of pump set, removing complete composite sludge through drain valve, stopping the leakages Reassembling top cover with conservator and explosion vent pipe, change of gasket for the top plate, cleaning oil level indicator and tightening all bolts and nuts & refilling new transformer oil through stream line filer to a required level with out any oil leakage, test & commissioning complete all as specified & directed by the Engr-in-Charge.3.00JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
8Maintenance and complete overhauling of 11 KV,3 phase, 400 Amps - 800 Amps, VCB including disassembling of operating mechanism parts, well cleaning with CRC-226 including reassembling, panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts and components complete, all as specified and directed by Engr-in-Charge. Note:- Spare parts will be measured and paid seperately under respective items.6.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
9Supply and fix Big gear for closing spring charge spare parts for 11 KV VCB, upto 400 Amps capacity indoor type complete all as specified and directed by engr-in-charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
10Supply and fix Small gear for closing spring charge spare parts for 11 KV VCB, upto 400 Amps capacity indoor type complete all as specified and directed by engr-in-charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
11Supply and fix Closing / triping coil assy of 11 KV VCB's type VE -12, 30 volts matching with the existing system complete all as specified and directed by Engr-in-Charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
12Supply and fix Spring charging motor & gear assy of 230 volts 0.25 HP, 8000 RPM of 11 KV VCB's type VE -12, 30 volts matching with the existing VCB system complete all as specified and directed by engr-in-charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
13Supply and fix Vaccum interrupters of 11KV, 400 Amps-800 Amps, frequency 50 Hz matching with the existing VCB system complete all as specified and directed by Engr-in-Charge.4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
14Supply & fix PT 11 KV / 110Volt 3 phase Potential transformer HT panel mounted/ draw out type, push fit with necessary fuses complete all as specified and directed by engr-in-charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
15Material & Labour for TOP Up ( topping) insulating oil for transformer conforming to IS-3356 at different Transformers & different locations complete all as specified and directed by Engr-in-Charge.460.00LtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only
16Earthing complete with GI earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (Earth pit not less then 2.25m deep below ground level ) with top edge not less than 1.5m below ground level connected to GI earth strip 32 x6 mm by means of GI bolts,nuts, check nuts,washers & GI strip ,protected by 50 mm bore medium grade GI pipe up to 7,5mtr distace including necessary charcol, salt & 20Kg Benzonite powder Funnel with wire mesh , watering pipe20mm dia medium grade excavation earth work PCC (1:3:6) type C-1 earth chamber , 50mm thick RCC cover with 6mm nominal reinforcement etc complete all as shown electrical plate No. 5 of MES schedule part Iall as specified and directed 9.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
17M&L for replacement of breather assembly transparent MS body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia or as per site requirement/ capacity of Transformer up to 750 KVA including taking down UNSV breather assembly complete all as specified & directed by the Engr-in-Charge.5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
18S&F microprocessor based electronic over current relay type IRI-PRO-V3-3I-EI complete including taking out old unsv defective/old vintage/obsolete model of relays from 11 KV VCBs including necessary additions/ alterations of VCB front panel including cutting welding of front size panel board/ position including necessary touch up to the panel board/ position including necessary touch up to the panel board all as complete and testing all as specified and directed. Make CG- CGI14N or equiv. as approved by GE.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
19Supply and fix Transformer Gaskets and seals made from a blend of nitrile rubber and cork complete for capacity 150KVA to 750KVA transformer including taking down UNSV gasket complete all as specified & directed by the Engr-in-Charge.2.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
20Supply only VCB 11 KV charging handle, made up of aluminium capable of withstanding the mechanical forces involved in compressing the opearting mechanism's spring having length 26 inch suitable to opearte existing VCB complete all as specified and directed by engr-in-charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
21M & L for finding cable fault with electronic fault detector in LT/HT UG cable of any size raging from 25 to 400 Sqmm 3/ 3.5 core, complete including necessary earthwork all as specified and directed by Engineer-in-charge.5.00JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
22Supply only discharge rod suitable for 11 KV, having upper body made up of cast aluminium and lower body made up of FRP material with copper wire not less then 16 sqmm with clamp to fix on earthing, having length not less then 18 ft and diameter 40mm complete all as specified and directed by Engr-in-charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
23Supply & fix in repairs gate valve (Gun metal), ISI marked of size 25mm including taking down old UNSV gate valve complete all as specified and directed by Engr-in-Charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
24Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 120 sqmm, 3.5 core incl taking down unsv LT cable complete all as specified and directed by Engr-in-Charge.151.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
25S&F Cable jointing Kit for 11KV (E) grade cable for indoor cable End termination heat shrink type joint complete with jointing material and accessories suitable for 11 KV(E) XLPE cable of size 50 sqmm to 95 sq mm 3 core with aluminium conductor complete all as specified and directed by Engr-in-Charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
26M&L for cleaning of E/M installations / campus surface dressing or trimming of branches of trees, cutting/ dressing of natural grass from ground to remove small unequalities n.exc 15 cm deep ( including removing vegetation / shrubs / brush wood / under-growth ), cleaning of drains & carrying away the rubbish to a distance of n.exc 50 mtr away complete, the area of installation up to 700sqm. at least 2 times in each installation at a interval of 3 months6.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
27Supply, install, testing & commissioning pedestal cubical type double door LT feeder piller box factory made modular construction febricated out of 3 mm thick CRCA sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements (compartment wise) front & back side opening system including rain shed, Overall size of each incoming & outgoing modules should not less than (350mmx350mmx550mm). and busbar chamber should be suitable for accomodating all Aluminium bus bar strips (50mm x 10mm x 04 Nos) fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom or upper part as mentioned below, complete electrically inter connected with Aluminium strips of suitablesize for all incoming and outgoing MCCBs and accessories with fixing arrangement on PCC (1:3:6) type C-2 bed block with studs, bolts, nuts & washers, Danger notyice board with scull suitable for 415 volts or required size to be fixed on Pannel and consisting of the following accessories including dismantling of old panel all as directed. 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
28Note:- (a) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-Charge (b) The cost of dismentling of old panel/F/piller Box is deem to be included above. (c) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set (d) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable CT of appropriate ratio.-01 No (e) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (f) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job Incoming :- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos. Outgoing :- (b) MCCB 4 pole , Ics=100%Icu- 36 KA, 415 Volts, 320 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (c) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos.
29Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 95 sqmm, 3 core incl taking down unsv complete all as specified and directed by Engr-in-Charge.80.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
30S&F Cable jointing Kit for 11KV (E) grade cable for outdoor cable straight through heat shrink type joint complete with jointing material and accessories suitable for 11 KV(E) XLPE cable of size 70 sqmm 3 core with aluminium conductor complete all as specified and directed by Engr-in-Charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
31Material and labour for straight Through Heat shrinkable type Cable Joint Kit including Jointing Materials for making Joints of LT UG Electric Cable 1100 Volt Grade Heavy Duty with XLPE insulated Aluminium Stranded Conductor size 50 Sqmm to 120 Sqmm x 3.5 Core and Testing complete all as specified and as directed.4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
32Refixing / relaying of existing disturbed / uprooted existing LT/HT electric cable of size upto 300 Sqmm to the existing places like uprooted from ground or out with the steel saddles from ground level to four storey bldg distribution box,etc complete with using/ electric drill machine, nut & bolt and proper grouted complete all as specified and as directed by engr-in-charge.200.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
33Supply and erect 8.5 meter long steel tubular swaged poles type 410 SP-22 complete with cast iron base plate, final taper plug, bolts, nuts & screws including taking down existing etc complete all as specified and as directed by Engineer-in-Charge. Note; Eacth work excavation, PCC for foundation and cooping will be measured and paid separately.8.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
34Supply & fix anti skid electrical insulating mat confirming to IS 15652/2006 (superceding IS : 5424-1969 ) BIS + CPRI+NTH+ERDA approved of C class of mats having dielectric strength 65 KV, sheet thickness not less than 2.5 mm using at power house including pasting of rubber mats with adhesive resin including taking down old UNSV rubber mats complete all as specified and directed by Engr-in-Charge.40.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
35Material and labour for GI sheet of size 10 x 8 inch welded with 2.5 foot of angle iron for marking earth pit grouted on ground with PCC at different area complete all as specified and directed by Engr-in-Charge20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
36Excavation in trenches depth more then 1.5m but not exc 3.0m for foudation of pole and getting out in soft/loose soil complate all as specified and directed by engr-in-charge.0.54CumExcess(+)1Full ConversionINR0.000.00INR Zero Only
37Material and labour for Plain Cement Concrete 1:3:6 type C2 using 40mm graded stone aggregate as in coping of poles including necessary formwork etc complete all as specified and as directed by the Engineer-in-charge0.41CumExcess(+)1Full ConversionINR0.000.00INR Zero Only
38Material and labour for Plain Cement Concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation / mass concrete including necessary formwork etc complete all as specified and as directed by the Engineer-in-charge4.70CumExcess(+)1Full ConversionINR0.000.00INR Zero Only
39Supply and fix plastic cooting print in GI sheet of size 10 x 8 inch for marking earth pit grouted on ground at different area complete all as specified and directed by Engr-in-Charge21.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
40Supply and fix Rolled mild steel plates (Plain or chequered) channels Fe 410-W (Gde-E-250)quality A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment without disturbing existing electric system including applying two coats of black paint over a coat of red oxide complete all as specified and directed by Engr-in-Charge.90.00KgExcess(+)1Full ConversionINR0.000.00INR Zero Only
41Supply and fix 11 KV HT bushing & brass/copper studs, gasket with-150 to 750 KVA including taking down UNSV HT Bushing complete all as specified & directed by the Engr-in-Charge.2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
42Supply & fix LT bushing and brass/copper studs, washer & Rubber bush etc for 150 to 750 KVA including taking down UNSV LT Bushing complete all as specified & directed by the Engr-in-Charge.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
43Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 240 sqmm, 3.5 core incl taking down unsv complete all as specified and directed by Engr-in-Charge.130.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
44M & L for dehydration of transformer oil through on load mobile stream line transformer oil filtration plant at site with all accessories connected to transformer and carrying out filtration of oil for desired dielectric strength ie not less than 45 KA at 4 mm gap.1800.00LtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only
45Material and labour for shifting of Transformer of any capacity and make, after dismantling of all electrical connection and carrying it to the new location, refixing it making electrical connections, installation testing, commissioning and making good the disturbed surface to match with the existing surfaces complete all as specified and as directed by Engineer-in-Charge1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
46Supply and fix space heater for 11 KV VCB, 230 V, 100 W, size should be 220 mm to 250mm to avoid moistures inside VCB Panel including taking down old UNSV heater complete all as specified nad directed by Engr-in-charge.10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
47Material and labour for complete removal of existing paint of steel tubular / rail poles length up to 11 mtr including preparation of outer surface and applying two coats of aluminium paint over a coat of red oxide and two strip of yellow and black colour paint of size 30 cm width from bottom of pole height 30 cm, including numbering to pole with base paint of yellow colour and Black for numbering should not be less than 100 mm in height and 10 mm in width, including dismantling of old/broken cooping of poles making new cooping with PCC 1:3:6 type C2 using 40mm graded stone aggregate with painting with white wash to the cooping complete all as specified and as directed by Engr-in-Charge144.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
Total in Figures0.000.00
Quoted Rate in FiguresSelect0.00000.0000 Zero Only
Quoted Rate in WordsINR Zero Only