Karnataka QTY :

Items - SPECIAL REPAIRS FLIGHT TEST CREW MEMORIAL AND MINOR WORKS AT ASTE UNDER GE (AF) MARATHAHALLI BANGALORE.

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver4.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority: GARRISON ENGINEER (AF) MARATHAHALLI, BANGALORE
Name of Work: SPECIAL REPAIRS FLIGHT TEST CREW MEMORIAL AND MINOR WORKS AT ASTE UNDER GE (AF) MARATHAHALLI BANGALORE.
Contract No: GE (AF)/BAN/ MAR/ OF 2025-2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Rs. P Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT TOTAL AMOUNT In Words
12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455
1.00Demolition of stone slab and tiles laided bedded and pointed in any mortar of any description or thickness in wall and floors, aprons etc complete all as specified and directed.433.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
2.00Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. 24.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
3.00M & L for 100mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floors and pavings etc, finishing with spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green, complete all as directed by Engr-in-charge.337.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
4.00M&L for Granite (of any type) slabs/tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 20mm thick Screed bed or bedding layer for laying floor finishes in CM 1:4 etc complete337.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
5.00M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:3 etc complete96.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
6.00Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. 200.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
7.00Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc 45.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
8.00Rendering 15mm thick in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smoothe without using extra cement. 54.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
9.00Dismantiling wrought iron or mild steel work of any description not otherwise provided for etc comoplete all as specified.1.50QtlExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
10.00Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates, chain, door etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including cutting of tile complete all as specified and directed.150.00KgExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
11.00M & L for broken stone or boulders hard core of gauge n exc 63mm deposited spread and leveled in layers n.exc 15 cm thick watered and rammed to true surface complete all as specified and directed.15.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
12.00M&L for 75 mm thick PCC 1:4:8 (40 mm graded aggregate) type D2 as in sub- base of floor complete all as specified and directed.100.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
13.00Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed.52.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
14.00S&F glazed ceramic coloured tiles 7mm thick 450 x 300mm size in vertical surfaces set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over and including 10mm thick rendering on fair faces of brick/stone work or concrete surfaces in CM 1:3 etc complete all as specified and as directed.52.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
15.00M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified45.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
16.00Removing building materials etc. to a distance of 5 Km out side MoD/Unit land including loading, unloading and stacking at the destination etc. complete all as direction of Engineer-in-charge, 24.00Per LoadExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
17.00Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable including taking out old bricks from trenches and separating serviceable bricks and set aside for reuse complete all as specified and as directed.16.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
18.00Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed.8.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
19.00Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.2.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
20.00Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified. Note : Punned thickness shall be measured & paid6.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
21.00M&L for brick protection cover on cable with sub class 'B' brick laid dry flat adjacent to each other complete all as specified and directed.0.49Per 1000 NosExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
22.00Supply and fixing of GI tubing, light grade, 32 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete. 12.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
23.00M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations for electric poles, filling and mass concrete complete all as specified and directed.1.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
24.00Supply and laying and testing cable XLPE insulated screened, PVC bedded, galvanised, steel strip or wire armoured, electric power cable, (heavy duty) 1100 volts grade, with stranded aluminium conductor of size 2 core 10 Sqmm NOTE : Excavation & Earthork, Sand cushioning & Brick protection shall be measured & paid seperately100.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
25.00Taking out carefully existing bollard light /focus/decorative pillar light and refixing the smart meter after repair work all as specified and directed.15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
26.00 Supply and fixing PVC insulated copper flexible cable 2.5 Sqmm 3 core, 1100 volts grade complete all as specified and directed.65.00RM Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
27.00Supply and fixing LED flood light 35 watt 230 V AC outdoor type with thermal management inmultiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed . 4.00EACHExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
28.00Supply and fixing post top lantern LED type 20watt 230 watt volts AC outdoor type with decorativepost top for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete withdriver and lamp complete.9.00EACHExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
29.00S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required cluding cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all omplete as per architectural drawings and the directions of Engineer-in-Charge complete all as specified and directed. 530.00kgExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
30.00S & F powder coated anodised alluminium door shutters, aluminium sections weighing 0.55 Kg/m including joining cleats glazing clips, rubber neoprene packing , handle 2 Nos in each door, hinges, anodised aluminium snap, mortice lock, beading screws, bearings etc. complete all as specified and as directed by Engr-in-Charge.29.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
31.00S&F Aluminium extruded section body, Door closer hydraulically regulated, deisignation No.3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and directed. 29.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
32.00S&F 5 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each panepanelfixed to alluminium frame works with neccessary rubbber bedding complete all as specified and directed. 13.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
33.00S&F for 12mm thick both side choice laminated prelaminated particle board for insulation purpose, fixed to aluminium framework, complete all as directed by Engr-in-Charge.100.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
34.00S&F Stainless steel 8 pin cloth hanger, wall mounted complete all as directed by Engr-in-Charge.15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
35.00S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers.15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
36.00Demolition of stone/Brick masonry built-in cement mortar incl all quions arches, pillars etc complete all as specified and directed.2.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
37.00M & L for Providing precast cement concrete solid blocks masonary type C1 1:3:6 (20mm graded aggregate) exc 10 cm in width and setting in cement mortar 1:6 all as specified and directed.2.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
38.00Roughening surfaces of old concrete floor by picking, sweeping lean and washing down with water to remove dust, etc. all as specified and as directed by Engineer-in-Charge.20.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
39.00S&F of light shade Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, all as specified and as directed.20.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
40.00S&F light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm,as skirtings etc set and jointed in neat cement slurry and pointed in white or coloured cement to match vertical surfaces including 10 mm rendering as in backing coat in CM 1:3 complete all as specified and directed.2.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
41.00M&L Rendering 15 mm thick on fair faces in CM 1:6 of brick work or concrete surfaces to be finished even and smooth (without using extra lime or cement) complete all as specified and directed.9.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
42.00Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth.9.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
43.00M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified.20.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
44.00Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.20.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
45.00S&F false ceiling grid of size 600 x 600 mm system using hot dipped galvanized steel section with precoated capping, main tee of size 24x32 mm having 0.27mm thick at every 1200mm centre to centre, cross tee of size 24x27 mm having 0.25mm thick at 600mm centre to centre and wall angle of size 19x19 mm having 0.35 mm thick fixed to the periphery of the wall, and suspended at every 1200mm centre to centre in both directed using 2.00 mm thick GI wire and fixing 600 x 600 x 16 mm mineral fibre ceiling tiles of Classic lite RH99 complete all as specified and as directed.60.00Sqm Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
46.00M & L for 2nd class softwood plain fillets, exc 13 & n.exc 25 sq.cm square, rectangular in section, clean sawn, secured with nails or brands, complete all as specified and directed. 54.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
47.00M&L for 12 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, all as specified and directed.54.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
48.00Preparation of old surface and applying one coat of oil bond distempering with emulsion on ceiling.60.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
49.00Preparation of old surface and applying one coat of Plastic emulsion paint on walls.50.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
50.00Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed by EIC.11.00Per pointExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
51.00Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed.30.00RmExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
52.00Taking down Split AC 1.5/2 Ton capacity ( Indoor and Out door Unit) with stabilizer by removing all electrical connections and indoor to out door unit gas pipes ,nut bolts at TPS and shifting to store for safecustody. After completion of civil work, Refixing /installing Split AC 1.5/2 Ton with voltage stabilizer at the same place by connecting all electrical connections and copper piping with insulation (5/8th x 1/4th) with nut bolts as per site requirement, testing and commissioning , if any extra cable , gas pipes , gas filling require at the time of installation the quoted rate is deemed to be included , No nextra cost will be paid to contractor complete all as specified and directed By Engr- In - Charge.2.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
53.00M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for the following :- (a) One light point /Fan point controlled by one switch. 3.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
53.01(b) One 5 Amps socket point on same board with other switches2.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
53.02(c) One 5 Amps socket point on independent board.3.00PointExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
53.03(d) All as per item No.53 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board .3.00Point Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
54.00Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed 8.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
55.00S & F modular socket 06 Amps 2/3 pin, 2 module complete all as specified & directed. 5.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
56.00Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed 3.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
57.00S & F modular socket 06/16 Amps 2/3 pin 2 module complete all as specified & directed. 3.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
58.00Supply & fixing of ceiling rose surface three terminals complete all as specified & directed. 3.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
59.00Supply and fixing 36W LED Fitting, 2' x 2' recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified 2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
60.00S&F Celing Fan complete with blades ,antisuicide down rods ,elcetronic regulator and acessories , 230 volts, 1200 mm sweep , min air delevery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
61.00M & L for sub main wiring complete with two runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. 30.00RM Excess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
62.00S & F MCB DB SPN 4 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed. 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
63.00S & F MCB SPN 40-63 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. 1.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
64.00S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. 3.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
65.00Supply and install hi wall split units air conditioner indoor/outdoor of capacity 2.0 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 complete all as specified and directed.1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
66.00S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only2Construction of chamber for 100mm sluices valveitem310Nos
67.00M & L for sub main wiring complete with two runs of 6 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 6 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. NOTE : Two runs of cable, one runf of PVC Conduit & one run of earth conductor shall be measured as one unit length. 30.00RM Excess(+)1Full ConversionINR0.000.00INR Zero Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
68.00M&L for mild steel stand duly painted suitable for fixing 3/2/1.5 TR AC out door unit fixing in wall / floor, including making bore required size for copper pipe & copper cable with sweating pipe required size and length upto ground level complete all as spcecified and directed.1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
69.00S&F single pole and neutrla enclosure with two pin and earth plug and socket including 1Nos double pole MCB 20 Amps capacity complete all as specified and directed by Engr-in-charge 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
Total in Figures0.000.00INR Zero Only4Construction of chamber for 100mm sluice platesitem510Nos
Quoted Rate in FiguresSelect0.00000.0000 Zero Only