Items - CLEANING OF WATER TANKS IN CERTAIN OTM AND MD ACCN AT SOUTH OF RLY LINE UNDER GE MISSAMARI
Item Rate BoQ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BoQ_Ver3.0 | Item Rate | Normal | INR Only | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
Select, Excess (+), Less (-) | Less (-) | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Tender Inviting Authority: GARISSON ENGINEER MISSAMARI | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Name of Work: CLEANING OF WATER TANKS IN CERTAIN OTM AND MD ACCN AT SOUTH OF RLY LINE UNDER GE MISSAMARI | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Contract No: GE/MISM/22 OF 2025-26 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bidder Name : | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
PRICE SCHEDULE (a) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) (b) Estimated rate Column is for Department use only. (Note: Credit amount if any vide Credit schedule shall be deducted from the total quoted amount of Sch 'A' to arrive total contract sum.) (c) The Tenderers attention is drawn to the fact that the Work Order No 1 shall be placed after submission of performance security of requisite amount in favor of Accepting Officer. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sl. No. | Item Description | Item Code / Make | Quantity | Units | Estimated Rate | Addition / Deduction | Addition / Deduction Values | Currency Convertion against each Item | Quoted Currency in INR / Other Currency | Quoted RATE In Figures To be entered by the Bidder Rs. P | Excise Duty | VAT | Freight Charges ( Unloading & Stacking) | Any Other Taxes/Duties/Levies | Other Taxes 2 | IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax | Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category | TOTAL AMOUNT Without Taxes | TOTAL AMOUNT With Taxes | TOTAL AMOUNT In Words | ||||||||||||||||||||||||||||||||||
1 | 2 | 3 | 3 | 4 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 5 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 | 51 | 52 | 53 | 6 | 7 |
1 | Disconnecting existing not exc. 250 ltrs capacity tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (Cleaning repairing, etc. measured separately), etc.complete in all as specified and as directed. | BI01010001010000000000000515BI0100001113 | 50.00 | Each | 0.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 1.01 | Supplying, Conveying and fixing spls. Including eart | item1 | 123.223 | Nos | |||||||||||||||||||||||||||||||||||||
2 | Disconnecting existing exc. 250 ltrs and not exc 500 ltrs capacity tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (Cleaning repairing, etc. measured separately), etc.complete in all as specified and as directed. | BI01010001010000000000000515BI0100001114 | 150.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
3 | Disconnecting existing exc. 500 ltrs and not exc 1000 ltrs capacity tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (Cleaning repairing, etc. measured separately), etc.complete in all as specified and as directed. | BI01010001010000000000000515BI0100001115 | 25.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
4 | Disconnecting existing exc. 1000 ltrs and not exc 2000 ltrs capacity tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (Cleaning repairing, etc. measured separately), etc.complete in all as specified and as directed. | BI01010001010000000000000515BI0100001116 | 6.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
5 | Dismantling water tanks capacity not exc. 250 ltrs tanks complete in all as specified and as directed. | BI01010001010000000000000515BI0100001117 | 25.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
6 | Dismantling water tanks capacity exc 250 ltrs and not exc. 500 ltrs tanks complete in all as specified and as directed. | BI01010001010000000000000515BI0100001118 | 35.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
7 | Dismantling water tanks capacity exc 500 ltrs and not exc. 1000 ltrs tanks complete in all as specified and as directed. | BI01010001010000000000000515BI0100001119 | 25.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
8 | M&L for seven stage cleaning and sterilization of inside the RCC/ PVC water storage tank of capacity not exceeding 500 Ltr of any description and in any position comprising following cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: rays Cleantech/ Inus watertech/ satya enterprise. Location: SAA seven stages are as under plants:- (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company ans scrubbing the walls of the tanks. (c). Third strage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified brannded halogen compound. (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69 . NOTE:-(i) COMPANY WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXIi-60/NB-69, BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE) (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE ROVISION . (III) STERILIZATION TEAM WILL BE QUALIFIED AND CONDUCTING OF SAME TO BE SUBMITTED BY AGENCY & CONTRACTOR FOR STERILIZATION OF WATER TANK. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE. | BI01010001010000000000000515BI0100001120 | 2152.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
9 | All as per ser item No 08 above but for of inside the RCC/ PVC water storage tank of capacity not exceeding 1000 Ltr through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. | BI01010001010000000000000515BI0100001121 | 250.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
10 | All as per ser item No 08 above but for of inside the RCC/ PVC water storage tank of capacity not exceeding 2000 Ltr through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. | BI01010001010000000000000515BI0100001122 | 20.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
11 | S&F in repair, 15mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms) complete all as specified and directed . | BI01010001010000000000000515BI0100001123 | 250.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
12 | S&F in repair, 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) complete all as specified and directed . | BI01010001010000000000000515BI0100001124 | 340.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
13 | S&F in repair, 25mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm- 55gms) complete all as specified and directed . | BI01010001010000000000000515BI0100001125 | 25.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
14 | M&L 15mm thick plaster of cement mortar (1:3) rendering on brick work or concrete surfaces of sunken slab mixed with and including modified styrene rubber emulsion as bonding agent (minimum @ 5 ltrs per 50Kg of cement) mixed with integral waterproofing liquid admixture (minimum @125 ml per 50 Kg of cemen) over the prepared surface, involving removing the spalled the loose plaster from the existing surfaces, removing oil, paint, grease corrision deposit and any oyher deleterious substances,sanding and wahing the surface with water. The surface sould be dry and free from honey comb and any frogien particles complete all as per manufacturer's instructions and as ditected Note:- (a) Work shall be carried out through specialized applicator approved by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted. | BI01010001010000000000000515BI0100001126 | 500.00 | Sqm | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
15 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. | BI01010001010000000000000515BI0100001127 | 1.40 | Qtl | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
16 | S&F Rolled mild steel sections as in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. confirming to Fe.290. Gde-E-165 including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed. | BI01010001010000000000000515BI0100001128 | 140.00 | KG | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
17 | S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms), complete in all as specified and as directed | BI01010001010000000000000515BI0100001129 | 35.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
18 | S&F 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms), complete in all as specified and as directed | BI01010001010000000000000515BI0100001130 | 25.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
19 | S&F 250 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms), complete in all as specified and as directed | BI01010001010000000000000515BI0100001131 | 25.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
20 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, complete all as specified and as directed. | BI01010001010000000000000515BI0100001132 | 170.00 | RM | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
21 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed. | BI01010001010000000000000515BI0100001133 | 340.00 | RM | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
22 | Supplying and laying of 32mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed. | BI01010001010000000000000515BI0100001134 | 200.00 | RM | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
23 | Taking up or down 20mm bore steel tubing and connections, complete all as directed. | BI01010001010000000000000515BI0100001135 | 170.00 | RM | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
24 | Taking up or down 25/32mm bore steel tubing and connections, complete all as directed. | BI01010001010000000000000515BI0100001136 | 540.00 | RM | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
25 | S&F in repair 20mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed | BI01010001010000000000000515BI0100001137 | 40.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
26 | S&F in repair 25mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed | BI01010001010000000000000515BI0100001138 | 50.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
27 | S&F in repair 32mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed | BI01010001010000000000000515BI0100001139 | 30.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
28 | S&F in repair, V type screen filter 75mm to 130 micron PVC body suitable for overhead PVC water tank suitable for 20/25mm bore pipe complete all as directed | BI01010001010000000000000515BI0100001140 | 100.00 | Each | 0.0000 | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
Total in Figures | 0.00 | 0.00 | INR Zero Only | 4 | Construction of chamber for 100mm sluice plates | item5 | 10 | Nos | ||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Figures | Select | 0.0000 | 0.0000 | Zero Only | ||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Words | INR Zero Only |
Andaman & Nicobar Tenders |Andhra Pradesh Tenders |Arunachal Pradesh Tenders |Assam Tenders |Bihar Tenders |Chandigarh Tenders |Chhattisgarh Tenders |Dadra & Nagar Haveli Tenders |Daman & Diu Tenders |Delhi Tenders |Goa Tenders |Gujarat Tenders |Haryana Tenders |Himachal Pradesh Tenders |Jammu & Kashmir Tenders |Jharkhand Tenders |Karnataka Tenders |Kerala Tenders |Ladakh Tenders |Lakshadweep Tenders |Madhya Pradesh Tenders |Maharashtra Tenders |Manipur Tenders |Meghalaya Tenders |Mizoram Tenders |Nagaland Tenders |Odisha Tenders |Pondicherry Tenders |Punjab Tenders |Rajasthan Tenders |Sikkim Tenders |Tamil Nadu Tenders |Telangana Tenders |Tripura Tenders |Uttarakhand Tenders |Uttar Pradesh Tenders |West Bengal Tenders |