Assam QTY :

Items - REPAIR MAINTENANCE OF GEYSERS FAN AND MISC ITEMS UNDER GE MISSAMARI

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver3.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority: GARISSON ENGINEER MISSAMARI
Name of Work: REPAIR/MAINT OF GYSERS, FAN AND MISC ITEMS UNDER GE MISSAMARI
Contract No: GE/MISM/25 OF 2025-26
Bidder Name :
PRICE SCHEDULE (a) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) (b) Estimated rate Column is for Department use only. (Note: Credit amount if any vide Credit schedule shall be deducted from the total quoted amount of Sch 'A' to arrive total contract sum.) (c) The Tenderers attention is drawn to the fact that the Work Order No 1 shall be placed after submission of performance security of requisite amount in favor of Accepting Officer.
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyQuoted RATE In Figures To be entered by the Bidder Rs. P Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With TaxesTOTAL AMOUNT With TaxesTOTAL AMOUNT In Words
12334678910111251415161718192021222324252627282930313233343536373839404142434445464748495051525367
1Taking down existing unserviceable geysers of any type and any capacity from wall and re-installation at any location including fixing with and including heavy duty pin type fastener 4 inch long and making necessary inlet/outlet water supply connections from existing source to geyser complete all as specified and as directedBI01010001010000000000000515BI0100001113325.00Each Job0.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
2M&L surface point wiring for One socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. BI01010001010000000000000515BI0100001114125.00Point0.00001Full ConversionINR0.000.00INR Zero Only
3M&L surface point wiring for One socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 4.00Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 4.00 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. BI01010001010000000000000515BI010000111523.00Point0.00001Full ConversionINR0.000.00INR Zero Only
4Inspection,checking adjustments and repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and refixing the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55º C. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) The cost of spare parts required for repair & mainenance of geysers covered under this item shall be measured and paid separately under the relevant item as supply only. (j) Make of geysers covered under the scope of work :- Sidhson, Bajaj, Recold, Crompton, Orison, Ditz premier, Peeco, Empire, Shakti, Sahas, Konark BI01010001010000000000000515BI0100001116336.00Each Job0.00001Full ConversionINR0.000.00INR Zero Only
5Supply only heating element, Round type / tikona type / banana type, 1.5 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of any make complete all as specified and as directedBI01010001010000000000000515BI0100001117275.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
6Supply only heating element, Round type / tikona type / banana type, 2 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of any make complete all as specified and as directedBI01010001010000000000000515BI0100001118175.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
7Supply only thermostat switch for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed.BI01010001010000000000000515BI0100001119250.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
8Supply only glass wool for geysers complete all as specified and as directed. BI01010001010000000000000515BI010000112025.00KG0.00001Full ConversionINR0.000.00INR Zero Only
9Supply only base assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed. BI01010001010000000000000515BI010000112118.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
10Supply only indicator lamp for geyser of any type colour green & red complete all as specified and as directed. BI01010001010000000000000515BI010000112285.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
11Supply only copper inner tank of minimum 22 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25/35 ltrs capacity geysers (weight not less than 3.75 kg) complete all as specified and as directed. BI01010001010000000000000515BI010000112338.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
12Supply only of Copper inner tank of minimum 22 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (weight not less than 5.25 kg) complete all as specified and as directed. BI01010001010000000000000515BI010000112432.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
13Supply only outer body of MS sheet not less than 22 gauge suitable for 25/35 ltr geyser with white synthetic enameled paints complete all as specified and as directed. BI01010001010000000000000515BI01000011254.00Each0.00001Full ConversionINR0.000.00INR Zero Only
14Supply only outer body of MS sheet not less than 22 gauge suitable for 50 ltr geyser with white synthetic enameled paint complete all as specified and as directed. BI01010001010000000000000515BI01000011264.00Each0.00001Full ConversionINR0.000.00INR Zero Only
15Supply only plug top 3 pin 15 Amp ISI marked complete all as specified and as directed. BI01010001010000000000000515BI010000112760.00Each0.00001Full ConversionINR0.000.00INR Zero Only
16Supply only bottom cover of PVC suitable for 25/35 ltrs capacity geysers complete all as specified and as directedBI01010001010000000000000515BI01000011288.00Each0.00001Full ConversionINR0.000.00INR Zero Only
17Supply only bottom cover of PVC suitable for 50 ltrs capacity geysers complete all as specified and as directed. BI01010001010000000000000515BI01000011298.00Each0.00001Full ConversionINR0.000.00INR Zero Only
18S&F in repair, 15mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, chromium plated fancy type, screwed both ends for iron pipe or for union, ISI marked, complete all as specified and as directed. BI01010001010000000000000515BI010000113010.00Each0.00001Full ConversionINR0.000.00INR Zero Only
19S&F in repair, 15mm bore Bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for ISI marked, complete all as specified and as directed. BI01010001010000000000000515BI010000113110.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
20S&F Switch piano flush type, single pole, one way, 16/20 Amp fixed as in repair complete all as specified and as directed. BI01010001010000000000000515BI010000113235.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
21S&F shuttered socket out let, 3 Pin, 16 Amp, 230 volts piano flush type fixed as in repair complete all as specified and as directed. BI01010001010000000000000515BI010000113335.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
22S&F in repair, Stainless steel connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe, complete all as specified and as directed. BI01010001010000000000000515BI0100001134210.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
23S&F in repair, stainless steel connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed. BI01010001010000000000000515BI0100001135160.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
24S&F in repair, 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded fixed as in repair complete all as specified and as directed. BI01010001010000000000000515BI0100001136350.00RM0.00001Full ConversionINR0.000.00INR Zero Only
25S&F Modular Switch piano flush type, single pole, one module, 16/20 Amp complete all as specified and as directed. BI01010001010000000000000515BI010000113760.00Each0.00001Full ConversionINR0.000.00INR Zero Only
26S&F Modular shuttered socket out let, 2/3 Pin, 6/16 Amp, 230 volts two module, complete all as specified and as directed.BI01010001010000000000000515BI010000113860.00Each0.00001Full ConversionINR0.000.00INR Zero Only
27Supply and laying in floor, fixed to walls and ceiling, 25mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed. BI01010001010000000000000515BI010000113942.00RM0.00001Full ConversionINR0.000.00INR Zero Only
28Supply and laying in floor, fixed to walls and ceiling, 20 mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed. BI01010001010000000000000515BI010000114048.00RM0.00001Full ConversionINR0.000.00INR Zero Only
29Supply and laying in floor, fixed to walls and ceiling, 15 mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed.BI01010001010000000000000515BI010000114166.00RM0.00001Full ConversionINR0.000.00INR Zero Only
30Cutting and screwing existing steel tubing of 15/20/25mm bore for alterations or additions (Each cut measured) required for connections to gysers complete all as specified and as directedBI01010001010000000000000515BI010000114220.00Each Job0.00001Full ConversionINR0.000.00INR Zero Only
31M&L Painting of outer surface of 25/35/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed. BI01010001010000000000000515BI0100001143120.00Each Job0.00001Full ConversionINR0.000.00INR Zero Only
32S&F in repair, Instant hot water heating element for any capacity complete all as specified and as directed.BI01010001010000000000000515BI01000011445.00Each0.00001Full ConversionINR0.000.00INR Zero Only
33Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. Note:- Concealed conduit in RCC slab/beam shall not be not be taken outBI01010001010000000000000515BI0100001145148.00Point0.00001Full ConversionINR0.000.00INR Zero Only
34Dismantling carefully solar storage water heating system of any capacity, any type for following works with testing and refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after carrying out necessary repair as under :- (a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Supply and fixing of Spare parts. wiring etc shall be measured & paid separately.BI01010001010000000000000515BI01000011466.00Each Job0.00001Full ConversionINR0.000.00INR Zero Only
35Supply only Heating element, 3.00 KW 230 volts, ISI marked suitable for solar geyers tank of any make complete all as specified and as directed. BI01010001010000000000000515BI01000011473.00Each0.00001Full ConversionINR0.000.00INR Zero Only
36Supply only thermostat switch for solar water heater (ISI marked) any make and size complete all as specified and as directed. BI01010001010000000000000515BI01000011483.00Each0.00001Full ConversionINR0.000.00INR Zero Only
37Repair and welding to copper water storage tank of solar storage water heating systme of any capacity 100 to 500 LPD, to prevent any type of leakage at site with testing and refixing the same in original position makig all water / electric connection to entire satisfication of Engineer-in Charge after necessary repair as under:- (a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Supply and fixing of Spare parts. wiring etc shall be measured & paid separately.BI01010001010000000000000515BI01000011492.00Each Job0.00001Full ConversionINR0.000.00INR Zero Only
38M&L sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through existing conduit/PVC casing capping, and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of 4sqmm PVC wire, one run of 4Sqmm earth wire will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTEDBI01010001010000000000000515BI0100001150150.00RM0.00001Full ConversionINR0.000.00INR Zero Only
39S&F in repair, Glass collector suitable for solar water heating system of any size complete all as specified and as directed. BI01010001010000000000000515BI01000011512.00Each Job0.00001Full ConversionINR0.000.00INR Zero Only
40S&F in repair, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of Capacity 20 Amps complete all as specified and directed. BI01010001010000000000000515BI010000115220.00Each0.00001Full ConversionINR0.000.00INR Zero Only
41S&F in repair, MCB, SPN, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.BI01010001010000000000000515BI010000115360.00Each0.00001Full ConversionINR0.000.00INR Zero Only
42S&F in repair, MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.BI01010001010000000000000515BI0100001154120.00Each0.00001Full ConversionINR0.000.00INR Zero Only
43S&F in repair, AC metal plug top with metal socket siutable for 20 Amps 3 Pin including necessary aconnections complete all as specified and directed. BI01010001010000000000000515BI010000115546.00Each0.00001Full ConversionINR0.000.00INR Zero Only
44S&F in repair 25x16mm, medium grade, PVC casing and capping duly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced. BI01010001010000000000000515BI01000011561200.00RM0.00001Full ConversionINR0.000.00INR Zero Only
45S&F in repair 25mm dia medium grade PVC Conduit duly fixed with Clamps on wall surfaces and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced. BI01010001010000000000000515BI0100001157150.00RM0.00001Full ConversionINR0.000.00INR Zero Only
46S&F in repair PVC square box 100mm x 100mm including refixing of old switch socket complete all as specified and as directed.BI01010001010000000000000515BI010000115850.00Each0.00001Full ConversionINR0.000.00INR Zero Only
47S&F in repair PVC square box 170mm x 100mm including refixing of old switch socket complete all as specified and as directed.BI01010001010000000000000515BI010000115950.00Each0.00001Full ConversionINR0.000.00INR Zero Only
48S&F in repair PVC square box 200mm x 150mm including refixing of old switch socket complete all as specified and as directed.BI01010001010000000000000515BI010000116050.00Each0.00001Full ConversionINR0.000.00INR Zero Only
49S&F in repair, ceiling fan capacitor 2.5 mfd as per site requirement heavy duty with metal body complete all as specified and directed. BI01010001010000000000000515BI01000011611980.00Each0.00001Full ConversionINR0.000.00INR Zero Only
50S&F in repair, ceiling fan capacitor 3.15 mfd as per site requirement heavy duty with metal body complete all as specified and directed. BI01010001010000000000000515BI010000116280.00Each0.00001Full ConversionINR0.000.00INR Zero Only
51S&F in repair, ceiling fan capacitor 4 mfd as per site requirement heavy duty with metal body complete all as specified and directed. BI01010001010000000000000515BI0100001163275.00Each0.00001Full ConversionINR0.000.00INR Zero Only
52Disconnecting and taking down Ceiling Fan/Wall Mounted/Exhaust Fan/Air Circulator of any Sweep by Electrical Connections, cleaning Internally and Externally thoroughly, replacement of Split Pins, Cotter Pins and Check-nuts, etc. overhauling, lubricating with approved Lubricants, re-assembling including , re-fixing in Original Position checking smooth functioning and including electrically connected with Flexible Wire multi -stranded Copper Conductor Cable of size 23/0.0076 from Ceiling Rose to Fan cleaning all dust, etc. after repair duly painted two coats as per existing colour over a coat of primer and testing complete all as specified and as directed. BI01010001010000000000000515BI01000011641600.00Each Job0.00001Full ConversionINR0.000.00INR Zero Only
53M&L rewinding Ceiling Fan 1200/1400mm Sweep of any Make and type with Super Enameled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and testing, complete all as specified and as directed.BI01010001010000000000000515BI01000011651316.00Each Job0.00001Full ConversionINR0.000.00INR Zero Only
54S&F Ball Bearing No. 6201(as approved) suitable for ceiling fans complete all as specified and directed.BI01010001010000000000000515BI01000011662632.00Each0.00001Full ConversionINR0.000.00INR Zero Only
55Supply and fixing Gun Metal Bush (as approved) suitable for ceiling fans 1200/1400 mm sweep complete all as specified and directed.BI01010001010000000000000515BI01000011671315.00Each0.00001Full ConversionINR0.000.00INR Zero Only
56M&L rewinding Exhaust Fan 300 mm Sweep of any Make and type with Super Ena-meled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and testing, complete all as specified and as directed.BI01010001010000000000000515BI0100001168230.00Each0.00001Full ConversionINR0.000.00INR Zero Only
57Supply and fixing Ball Bearing (as approved) suitable for Exhaust fans 30mm sweep complete all as specified and directed.BI01010001010000000000000515BI0100001169460.00Each0.00001Full ConversionINR0.000.00INR Zero Only
58Supply and fixing Gun Metal Bush (as approved) suitable for Exhaust fans 300 mm sweep complete all as specified and directed.BI01010001010000000000000515BI0100001170230.00Each0.00001Full ConversionINR0.000.00INR Zero Only
59M&L rewinding Exhaust Fan 380/450 mm Sweep of any Make and type with Super Enameled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and testing, complete all as specified and as directed.BI01010001010000000000000515BI010000117130.00Each Job0.00001Full ConversionINR0.000.00INR Zero Only
60Supply and fixing Ball Bearing (as approved) suitable for Exhaust fans 380mm/450mm sweep complete all as specified and directed.BI01010001010000000000000515BI010000117260.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
61Supply and fixing Gun Metal Bush (as approved) suitable for Exhaust fans 380/450 mm sweep complete all as specified and directed.BI01010001010000000000000515BI010000117330.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
62M&L rewinding Air circulator Fan 450/600mm Sweep of any Make and type with Super Enameled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and testing, complete all as specified and as directed.BI01010001010000000000000515BI010000117424.00Each Job0.00001Full ConversionINR0.000.00INR Zero Only
63Supply and fixing Ball Bearing (as approved) suitable for Air circulator Fan 450/600mm Sweep complete all as specified and directed.BI01010001010000000000000515BI010000117548.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
64Supply and fixing Gun Metal Bush (as approved) suitable forAir circulator Fan 450/600mm Sweep complete all as specified and directed.BI01010001010000000000000515BI010000117624.00Each0.00001Full ConversionINR0.000.00INR Zero Only
65Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed.BI01010001010000000000000515BI010000117720.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
66Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as directed.BI01010001010000000000000515BI0100001178150.00RM0.00001Full ConversionINR0.000.00INR Zero Only
67S&F in repair, armature core of ceiling fan 1200mm sweep as per site requirement complete all as specified and directed.BI01010001010000000000000515BI0100001179100.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
68S&F in repair, armature core of Exhaust fan 300mm sweep as per site requirement complete all as specified and directed.BI01010001010000000000000515BI010000118050.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
69S&F in repair, armature core of Exhaust fan 380mm/450mm sweep as per site requirement complete all as specified and directed.BI01010001010000000000000515BI010000118115.00Each0.00001Full ConversionINR0.000.00INR Zero Only
70S&F in repair, PVC fan blade of exhaust fan 200mm sweep as per existing complete all as specified and directed.BI01010001010000000000000515BI010000118225.00Each0.00001Full ConversionINR0.000.00INR Zero Only
71S&F in repair, blower motor of PVC sturdy plastic fan 200mm sweep as per existing complete all as specified and directed. BI01010001010000000000000515BI010000118325.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
72S&F in repair, PVC fan blade of exhaust fan 250mm sweep as per existing complete all as specified and directed.BI01010001010000000000000515BI010000118420.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
73S&F in repair, blower motor of PVC sturdy plastic fan 250mm sweep as per existing complete all as specified and directed. BI01010001010000000000000515BI010000118520.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
74S&F in repair, PCB of BLDC Ceiling fan 1200mm sweep as per existing complete all as specified and directed. BI01010001010000000000000515BI010000118630.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
75Supply only remote of BLDC ceiling fan 1200mm sweep as per existing complete all as specified and directed. BI01010001010000000000000515BI010000118730.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
76S&F CI fan hook of shape and size as per site requirement fixed in ceiling and making good the the distrubed surfaces complete all as specified and directed.BI01010001010000000000000515BI010000118830.00Each 0.00001Full ConversionINR0.000.00INR Zero Only
77S&F in repair, Clamps for hanging of ceiling fan with rubber nuts, bolts etc as required complete all as specified and directed.BI01010001010000000000000515BI010000118920.00Each0.00001Full ConversionINR0.000.00INR Zero Only
78S&F in repair, 1100 Volts grade PVC insulated stranded flexible copper conductor twin core 1.00 sqmm and connecting from ceiling rose to terminal block of fan complete all as specified and directed.BI01010001010000000000000515BI0100001190480.00RM0.00001Full ConversionINR0.000.00INR Zero Only
Total in Figures0.000.00INR Zero Only4Construction of chamber for 100mm sluice platesitem510Nos