Items - CERTAIN B/R REPAIRS TO TOILETS, FLOORS, ROOF, CEILING, SUNKEN FLOORS, LEAKAGE/ SEEPAGE AND PLUMBING WORKS OF NOFRA NAVAL BASE KARWAR UNDER GE (SB) KARWAR.

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver3.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority: GARRISON ENGINEER SEABIRD KARWAR.
Name of Work: CERTAIN B/R REPAIRS TO TOILETS, FLOORS, ROOF, CEILING, SUNKEN FLOORS, LEAKAGE/ SEEPAGE AND PLUMBING WORKS OF NOFRA NAVAL BASE KARWAR UNDER GE (SB) KARWAR
Contract No: GE (SEABIRD)/KWR/ OF 2025-2026
Bidder Name:
PRICE SCHEDULE : (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Sl. No.Item DescriptionItem Code / MakeQtyUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Rs. P Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without TaxesTOTAL AMOUNT With TaxesTOTAL AMOUNT In Words
12334678910111251415161718192021222324252627282930313233343536373839404142434445464748495051525367
1.00Demolition of cement concrete of any description as in sunken floor or in any position as specified and directed.12.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.00Treatment of sunken floor slab comprises of the following specifications and all as specified:- (i) M&L for cleaning the sunken/ lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick average PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in padding concrete to achieve proper slope (ii) Rendering of uneven surfaces with 5mm thick CM 1:3 mixed with integral water proofing compound at the rate as per manufacturer's instructions. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting to be carried out (WPC shall be measured and paid separately) (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. 55.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.01(v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturer's instruction to bottom and vertical sides up to finished floor level +100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky,, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (This item shall be measured and paid separately). (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately ) (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6, type C-1 all round after painting with anticorrosive paint (Black paint shall be paid separately) Note:- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing shall be deemed to be included in the rate quoted above.
3.00M&L for applying two coats of polymer modified cementious water proof coating as per manufacturer's instruction to bottom and vertical sides up to finished floor level +100mm height. The thickness of two layers shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.60.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.00Supply only Integral Water proofing compound complete all as specified and directed. 170.00KgExcess(+)1Full ConversionINR0.000.00INR Zero Only
5.00M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in sunken floor of toilet complete all as specified and as directed.16.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only
6.00Taking up or down GI tubing and connections 15mm bore including fittings/ connections etc., all as specified and directed.100.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
7.00Taking up or down GI tubing and connections 20mm bore including fittings/ connections etc., all as specified and directed.70.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
8.00S&F 15mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed to walls, ceiling or on floors etc complete all as specified and directed.100.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
9.00S&F 20 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed to walls, ceiling or on floors etc complete all as specified and directed.70.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
10.00S&F in repairs stop valves/angle valve, of 15mm bore cast copper alloy fancy type chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe all as specified and directed20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
11.00S&F in repairs stop valves, of 15mm bore cast copper alloy fancy type chromium plated with long shank and cup (concealed type) for iron pipe complete all as specified and directed.20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
12.00S&F in repair 25mm dia gun- metal globe or gate valves, with iron wheel head screwed both ends for iron pipe complete all as specified and as directed. 8.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
13.00Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing all the rubbish etc complete all as specified and directed.560.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
14.00M&L for coloured glazed ceramic tiles (1st quality) of size 300 x 200 x 6 to 7mm / 300 x 450 x 6 to 7mm thick on vertical surfaces such as skirting, dado and rises to steps etc., including 10mm thick CM 1:3 backing coat set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles complete all as specified and directed.150.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
15.00M&L for non skid ceramic coloured tiles (1st quality) 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.06 Sqm but n.exc 0.11 Sqm on floors etc laid over and including 15mm thick screed bed in CM 1:4 and set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and directed.80.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
16.00Taking down chowkats or frames exc 1.5Sqm but n.exc 4 Sqm each with shutter (without taking off shutter from the frame) complete all as specified and as directed 40.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
17.00All as per item No.16 above but n.exc 1.5 Sqm5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
18.00S&F solid PVC door frame of size 50mmx 47mm made out of 5mm wood grains printed PVC sheet reinforced with MS square tube and edges painted to match with printed sheet complete all as specified and directed.70.00RM Excess(+)1Full ConversionINR0.000.00INR Zero Only
19.00S&F factory made solid panel PVC door shutter 30 mm thick (styled) consisting of frame made out of MS tube for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC, C" channel having a PVC sheet strip of 20mm width stuck in side with solvent cement for stiles and plain colour PVC sheet for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet bedding and jointed together with solvent cement supplying and fixing in the frame at site all as specified and directed.35.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
20.00S&F 150mm long Aluminium anodized handle of extruded sections etc complete all as specified and directed. 50.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
21.00S&F 100mm medium weight Mild Steel Butt hinges to the frame etc complete all as specified and directed.50.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
22.00S&F 75mm medium weight Mild Steel Butt hinges to the frame etc complete all as specified and directed.60.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
23.00S&F 150mm long aluminium anodized barrel tower bolts of extruded sections complete all as specified and directed. 50.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
24.00S&F 300mm long aluminium alloy, anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cost of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. 25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
25.00S&F in repairs vitreous china wash down water closet (pedestal pattern) white, including fixing bolts and necessary connection with existing pipes etc complete all as specified and directed. Note: Quoted rate shall excludes the cost of flush pipe, cistern & seat cover and the same shall be paid separately under respective item. 25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
26.00S&F in repair seat cover for pedestal pan with plastic water closet seat , white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. 35.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
27.00S&F in repairs 10 litre capacity PVC valveless syphonic action type flushing cistern high or low level (exclusive of brackets) white with inlet ball valve, float and handle including brackets complete all as specified and directed. 25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
28.00S&F in repairs 15mm dia PVC connection 450mm long complete all as specified and directed. 60.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
29.00S&F in repairs flush pipes PVC 32mm dia of 600mm long for low level flushing cistern to pedestal pan, including all joints, cones, India rubber (nozzles of W.C pans) all as specified and directed.25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
30.00S&F in repairs brass chromium plated Health faucet with spring pipe and required nipple all as specified and directed. 35.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
31.00S&F in repairs two way bib cock with two lever and wall flange chromium plated brass of approved make, screwed for iron pipe 15mm bore complete all as specified and directed10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
32.00S&F in repairs Wash hand basin vitreous china (flat back) size 550 x 400mm including brackets waste brass chromium plated with long screwed shanks and fly nuts 32 mm size including bottle trap complete all as specified and directed.35.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
33.00S&F in repairs 15mm bore fancy type pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe45.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
34.00S&F in repairs 32mm dia PVC waste pipe of 750mm long for WHB and urinals complete all as specified and directed. 64.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
35.00S&F in repairs 32mm size waste fitting (coupling) brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed all as specified and directed.65.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
36.00M&L for 600x450mm bevelled edge looking mirror 5mm thick selected quality glass mounted on 6mm thick AC building board fixed to wall by wooden plug with chromium plated brass screw and cup washer fixed as in repair complete all as specified and directed.45.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
37.00S&F in repairs 80mm dia brass chromium plated shower rose with swivel joints fancy type suitable for 15mm bore GI pipe all as specified and as directed.35.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
38.00S&F in repairs brass chromium plated mixer for mixing hot & cold water screwed down for 15mm dia iron pipe of complete all as specified and directed.25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
39.00S&F in repairs 15mm bore bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and directed.55.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
40.00M&L for PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or fixed on floors of 110mm bore etc complete all as specified and directed.45.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
41.00M&L for PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or on floors of 75mm bore 55.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
42.00S&F 75mm dia PVC (SWR) bend all as specified and directed 25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
43.00S&F 100mm dia PVC (SWR) bend all as specified and directed 25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
44.00S&F PVC (SWR) floor trap of 110mm dia, plain with grating including jointing with solvent cement etc complete all as specified and directed.25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
45.00S&F PVC (SWR) floor trap of 75mm dia, plain with grating including jointing with solvent cement etc complete all as specified and directed.25.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
46.00M&L for non skid ceramic coloured tiles (1st quality) 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm on floors etc laid over and including 15mm thick screed bed in CM 1:4 and set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and directed.120.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
47.00M&L for non skid ceramic coloured tiles (1st quality) 7 to 8mm thick (Square/ rectangular), area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm on vertical surfaces such as skirting, dado and rises to steps etc. including 10mm thick CM 1:3 backing coat set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles complete all as specified and directed.12.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
48.00M&L for vitrified ceramic tiles of premium quality, light shade, 9-10 mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 Sq.m (size 600 x 600 mm), laid in floors with neat cement slurry @ 3.00 kg/Sqm over and including 15mm thick screed bed of cement mortar 1:4 including pointing in white cement with pigment to match the shade of tiles, complete all as specified. 153.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
49.00M&L for vitrified coloured tiles of 600x 600 x 9-10 mm thick as in skirting set and jointed in neat cement slurry and pointed in colour cement over and including 10 mm thick backing coat in cement mortar 1:3 complete all as specified and directed. 45.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
50.00Dismantling of single layer Mangalore pattern or similar tiles in roofing all as specified and directed.600.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
51.00M&L for roof tiles, Mangalore pattern class 'AA', interlocking at side joints, laid dry complete all as specified and directed. 350.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
52.00All as per Srl item No.51 above but except tiles250.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
53.00M&L for Ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed. 150.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
54.00M&L for plain cement concrete 1:3:6 type C-0 using 12.5mm graded stone aggregate as in roof kerbs or mud stops, or beading for tiles, chamfered at edges complete all as specified and directed. 3.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only
55.00Dismantling/ taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing the dismantled debris to a distance exc 200m & n.exc 250m all as specified and directed350.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
56.00M&L for providing 15mm thick rendering over roof slab in cement mortar 1:4 mixed with water proofing compound at the rate as per manufacturer's instructions finished even and smooth surface without using extra cement all as specified and directed. Note:- WPC shall be measured and paid seperately.350.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
57.00M&L for water proofing treatment by applying oil bound bitumen primer, having a density of 0.87 - 0.89 Kg/lit, @ 0.40 ltrs/Sqm, providing and laying not less than 3mm thick APP modified water proofing membrane weighting not les than 3.60 Kg/Sqm of approved make including minimum 10 cm side lap and 15 cm end lap, laid and pasted with blue flame torching applications and finally finishing with two coats of solar reflective bituminous aluminium paint @ 0.1.Kg/Sqm all as specified and directed. Note:- The entire job shall be done through authorised applicator of approved make only.420.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
58.00Dismantling of wall and ceiling boards (fibre, pulp, insulation) or insulation boards /slab /blankets of any description and thickness including frame/grid of any description all as specified and directed250.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
59.00M&L for Anodised Aluminium snap grid (minimum 15 microns anodisation) of size 605 x 605 mm with anodized aluminium angle of size 40mm x 25mm x 2mm thick weighing 0.36 Kg per running meter and anodized aluminium main and cross T of size 36.50 x 23.50 x 1.50 mm thick weighing 0.254 Kg per running meter and 23.50 x 23.50 x 1.50 mm thick weighing 0.202 Kg per running meter respectively for false ceiling all as specified and directed 250.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
60.00S&F hangers 6mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long suitable for size of snap grid 605 x 605 mm complete all as specified and directed250.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
61.00M&L for 10mm thk PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification etc complete all as specified and directed250.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
62.00Taking down cement plaster on brick or concrete surfaces of wall/ceiling and likes including racking out joints, hacking for keys scrubbing down with water etc any description including removal of rubbish outside MoD land, complete all as specified and directed. Note : The rate quoted by the contractor is deemed to be included necessary scaffolding and safety measures.450.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
63.00M&L for Rendering 15mm thick on brick or concrete surfaces in cement mortar 1:4 mixed with waterproofing compound at the rate as per manufacturer's instruction complete all as specified. Note:- WPC shall be measured and paid seperately.200.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
64.00M&L for rendering 10mm thick in CM 1:6 on fair faces of concrete surfaces all as specified and directed200.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
65.00M&L for 5mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces as in ceiling all as specified and directed50.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
66.00M&L for preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer including finishing of surface with 3mm thk wall care putty etc complete all as specified and directed200.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
67.00M&L for preparing newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of Primer including finishing of surface with 3mm thk wall care putty etc complete all as specified and directed50.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
68.00M&L for two coats of exterior emulsion weather proof paint over a coat of exterior primer including preparation of newly plastered surfaces of walls all as specified and directed..200.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
69.00Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc., all as specified and directed.205.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
70.00M&L for PVC Rain water pipe single socketed in any length with rubber ring joints fixed to wall 110mm bore etc complete all as specified and directed.120.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
71.00S&F 110mm dia PVC bend all as specified and directed 20.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
72.00M&L for 160mm bore PVC Rain water pipe single socketed in any length with rubber ring joints fixed to wall etc complete all as specified and directed.85.00RMExcess(+)1Full ConversionINR0.000.00INR Zero Only
73.00S&F 160mm dia PVC bend all as specified and directed 15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
74.00Dismantling of PVC water storage tank of capacity exceeding 250 litre but not exceeding 500 litre complete all as specified.10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
75.00Dismantling of PVC water storage tank of capacity exceeding 500 litre but not exceeding 1000 litre complete all as specified.15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
76.00S&F Rotational moulded PVC, triple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, complete all as specified. 10.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
77.00S&F Rotational moulded PVC, triple layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, complete all as specified. 15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
78.00Draining out water, cleaning and removing accumulated sludge/ dirt scales from tank bottom, side and from mouths of circulating pipes of service tank of capacity not exceeding 500 ltrs, located on roof of the building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enamel paint on black ground "CLEANED ON (DATE)" height of the words 100mm, complete all as specified and directed.55.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
79.00Draining out water, cleaning and removing accumulated sludge/dirt scales from tank bottom, side and from mouths of circulating pipes of service RCC/PVC tank of capacity exceeding 500 ltrs but not exceeding 1000 ltrs, located on roof of the building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enamel paint on black ground " CLEANED ON (DATE)" height of the words 100mm, complete all as specified and directed.250.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
80.00Supplying and fixing in repairs 25mm bore brass float valve, high pressure with polythene float & fly nut complete, screwed for GI pipe including necessary GI fittings complete all as specified.135.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
81.00Supplying and fixing in repairs 40 mm bore brass float valve, high pressure with polythene float & fly nut complete, screwed for GI pipe including necessary GI fittings complete all as specified.65.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
82.00Removing demolished material to a distance n.exc 50m and deposited where directed at a level not exc 1.5 m above the base all as specified and directed.25.00CumExcess(+)1Full ConversionINR0.000.00INR Zero Only