Bidhelp
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE SWC AND CE JAIPUR JAIPUR - MES||CWE Mathura - MES
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE SWC AND CE JAIPUR JAIPUR - MES||CWE Mathura - MES
CWE Mathura
Rajasthan QTY :

Items - As per tender documents

Tender Details
Costs
Documents
BOQ

BoQ1

BoQ_Ver3.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority : CWE MATHURA
Name of Work : Spl repair/replacement of four pole structure with RMU at 39 FAD at Bharatpur Mil Stn
Contract No : CWE/MTR/BPR/ OF 2025-26
Bidder Name :
SCHEDULE 'A' (BOQ) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyRate In Figures To be entered by the Bidder Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Total Amount TOTAL AMOUNT With TaxesTotal Amount In Words
12334678910111251415161718192021222324252627282930313233343536373839404142434445464748495051526547
1.00Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. 138.00Cum114.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
2.00Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.94.00Cum115.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
3.00Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.44.00Cum116.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
4.00Supply, laying, jointing and testing HT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium stranded conductor 11000 Volt (Earthed) grade of cross sectional area 50 sqmm, 3 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc, complete all as specified & as directed. Notes:- (i) Sand cushioning, cable protection, GI protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.400.00RM147.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
5.00M&L for sand cushioning using unwashed dry river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of under ground electric cable complete all as specified and as directed. Notes:- (i) Approved unwashed dry river sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.27.00Cum133.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
6.00M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.5.80Per 1000 Nos148.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
7.00M&L for Boring of holes of 100mm bore under road, pavement, hard standing by suitable tools and necessary machine suitable for passing the GI protection pipe / cables, complete all as specified and as directed.25.00RM149.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
8.00M&L for Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately. 36.00RM148.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
9.00M&L for earthing to equipments with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.6.00Each Set147.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
10.00S&F of 11 KV Extensible Outdoor duty (IP 55 enclosure) SF6 gas insulated 4 way motor operated Ring Main Unit (RMU) comprising of 1 No 630 Amp Vacuum Circuit Breaker as incomer and 3 Nos, 630 Amps Vacuum Circuit Breaker as outgoing, cable termination from the front, breaking capacity 21 KA/3sec (Internal Arc Classification AFLR 21 kA-1sec with Bottom Exhaust both for tank and cable box as per IEC 62271-200), enclosed in robotically welded stainless steel tank having IP67 Degree of Protection, leak rate of SF6 gas less than 0.1% and tested as per IEC 60056/60694/60298. Protection CTs shall be ring core type, complete all as specified and directed. Line PT should be mounted only in the rear side (Top or Bottom) of the Panel. Make of RMU : Siemens (8DJH-ST)/ Scheider (FBX) / ABB (Safe Plus- XT). 2.00Each Job149.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
10.01(A) NOTE: Other details: System Particulars : (i) Nominal System Voltage : 11 kV. (ii) Voltage variation on supply side : ±10 %. (iii) Corresponding Highest System Voltage: 12kV. (iv) Frequency : 50 Hz with ± 3 % tolerance. (v) Transient condition : -20 % or + 10 % combined variation of Voltage and frequency. (vi) Number of Phase : 3 Phases. (vii) Neutral earthling :Solidly earthed. viii) Fault level (minimum) kA /Sec : 21/3). (ix) Lightning Impulse Withstand Voltage (kVp) : 75 (x) One minute dry/wet power frequency withstand voltage primary (kV rms) : 28KV (xi) Rated Dynamic Withstand Current (kAp) : 52.5KA. (xii) Number of Short Circuit Operations at rated short circuit current of 21 kA for Breaker - 50 Nos. (xiii) Earth switch with its own making capacity independent of breaker with own snap action mechanism for fast closingindependent of operator action (E2 Class).
10.02(B) Applicable Standards for this RMU scope of work - IEC 62271-200. (i) The Ring Main Units shall conform to the latest applicable, IEC 62271-100, IEC 62271-200. (ii) All live parts, bus bars, shall preferably be enclosed in non- magnetic and non-ferrite grade stainless steel tank Grade SS441 of minimum 2 mm thickness. The RMU shall be type tested for internal arc test of 21KA/1 sec AFLR with Bottom Exhaust for Safety of Personnel for both Tank as well as Cable Compartment as per IEC62271-200. The outer enclosure shall have IP 55 protection for complete switchgears, however it should be Top Opening Canopy & Indoor RMU placed inside Outdoor Enclosure should not be acceptable. The protection relay shall be for 3 O/C + 1E/F (IDMT Type) Self powered numerical protection relay with low and high set of over current and earth fault , MODBUS communication along with RS 485 Port / USB Port. (iii) Internal Arc Classification should be with Bottom exhaust only. RMUs should be manufactured, inspected, and invoiced from the OEM factory. (v) Smart demand controller required with accuracy Class 0.5 as per IEC 62053 22. True RMS measurement 64 samples per cycle. Power quality analysis: THD % measurements and Individual harmonics up to 31st order for voltage and current, per-phase. Demand anagement: Simultaneous display of peak, present, predicted & rising demands of all the four demand parameters (W, VA, VAR, Amps) configurable for 1 to 30 minutes interval with prediction and spare load. Demand controller should have on board Modbus RTU RS-485 communication port. Demand controller should have Billing: Tenant billing/utility meter cross check (where local regulations are not applicable).
10.03(C) Air Insulated Bus Connected Unit comprising the following, (1) Air Insulated enclosure with necessary bus connection via bushing. VT’s from the manufacturer and according to IS 3156 shall be accepted. (2) 11KV/rt3/110V/rt3; 50VA class 0.5. Single phase bus PT for metering. (3) 11KV/230V AC, 1KVA control transformer – Optional is Aux supply at site is not available. (4) Demand Controller Class 0.5 for Incomer only. (5) Metering CT in respective Function’s Cable Compartment in RMU XX/1A, Class 0.5, 2.5 VA. Accessories with each RMU includes : (i) Operating handle - 1 No (ii) Right angled Cable boots- 4x sets. (iii) Capacitor Voltage indicator type HR-ST - 4 Nos. Make Hortsmann. Saperate Metering chamber includes:- (i) 3 Phase, 3 Limb draw out type bus connected Epoxy potential transformer, ratio 11KV/√3/110V/√3 AC accuracy 1.0, burdon 50 VA - 01 (ii) Digital type voltmer -1No (iii) RYB indication - 1set Note :-(i) RMU shall be outdoor PCC platform mounted. (ii) Civil work PCC platform) for RMU is deemed to be included in the unit rate quoted by contractor. The PCC platform details as per the manufacturer's instructions.
11.00M&L for cable end termination jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for HT XLPE armoured aluminium conductor cable of size 120 sqmm x 3 core complete all as specified & as directed.8.00Each Job149.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
12.00M&L for cable end termination jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for HT XLPE armoured aluminium conductor cable of size 120 sqmm x 3 core complete all as specified & as directed.2.00Each Job148.0000Excess(+)1Full ConversionINR0.000.00INR Zero Only
Total in Figures0.000.00INR Zero Only4Construction of chamber for 100mm sluice platesitem510Nos
Quoted Rate in FiguresSelect0.00000.0000 Zero Only