Items - PROVN OF 05 X SECURITY LIGHT WITH POLE IN MAG AREA KATIHAR MIL STN AND PROVN OF 10 X WATER COOLER AT MIL STN KATIHAR
Item Rate BoQ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BoQ_Ver3.0 | Item Rate | Normal | INR Only | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
Select, Excess (+), Less (-) | Less (-) | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Tender Inviting Authority: AGE (I) KATIHAR | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Name of Work: PROVN OF 05 X SECURITY LIGHT WITH POLE IN MAG AREA KATIHAR MIL STN AND PROVN OF 10 X WATER COOLER AT MIL STN KATIHAR. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Contract No: AGE (I)/KTR/ of 2025-2026 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bidder Name : | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
PRICE SCHEDULE (SCHEDULE 'A') (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sl. No. | Item Description | Item Code / Make | Quantity | Units | Estimated Rate | Addition / Deduction | Addition / Deduction Values | Currency Convertion against each Item | Quoted Currency in INR / Other Currency | RATE In Figures To be entered by the Bidder Rs. P | Excise Duty | VAT | Freight Charges ( Unloading & Stacking) | Any Other Taxes/Duties/Levies | Other Taxes 2 | IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax | Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category | TOTAL AMOUNT Without Taxes | TOTAL AMOUNT With Taxes | TOTAL AMOUNT In Words | ||||||||||||||||||||||||||||||||||
1 | 2 | 3 | 4.00 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 | 51 | 52 | 53 | 54 | 55 |
1.00 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, G.I (medium grade, ISI ) pipe 40mm dia, 1.5 Mtr long medium grade, bend to shape for street light fittings bracket, with 2 pairs of MS clamps of suitable length/size complete all as specified and as directed by Engineer-in-Charge. | 5.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
2.00 | M&L for G.I (medium grade, ISI ) pipe 40mm dia, 1.5 Mtr long medium grade, bend to shape for street light fittings bracket, with 2 pairs of MS clamps of suitable length of size 40 mm x 5 mm of MS flat iron with nuts, bolts & washer including applying two coats Synthetic enamel aluminium paint over a coat of red-oxide taking out old unserviceable ones, complete all as specified and as directed by Engineer-in-Charge. | 5.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
3.00 | S&F weather proof junction box made of thermoplastic polycarbonate with gasket comply with -IP 66, dust and jet water proof of size 155x210x92 mm (with Knockouts for cable entry) including Terminals , for cable size upto 10 to 16 sqmm alongwith cable inlet including a pairs of MS flat iron Clamp suitable length with washer, suitable to fix in Steel tubular pole/PCC pole, including taking out existing unserviceable junction box of any type and size, disconnection of existing cable connection and reconnection of cable by providing suitable size cable lugs & gland, complete all as specified and as directed by Engineer-in-Charge. Make : Hensel Cat Part No- DK-1616G or equivelent in Sintex / C&S as approved by Engr in charge. Note : Contractor shall provide cable lugs and gland of suitable size if required on site for connecting cable in junction box, rate shall be inclusive in quoted rate. | 5.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
4.00 | S&F cable PVC insulated flexible type 1.5 sqmm x 3 core copper conductor cable, complete all as specified and as directed by Engineer-in-Charge. | 45.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
5.00 | Material and labour for fixing steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of red oxide primer, externally from top of coping complete all as specified and as directed by Engineer-in-Charge. | 5.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
6.00 | Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core including connecting the cables at both ends by providing suitable size aluminium lugs & glands at the termination ends, complete all as specified and as directed by Engineer-in-Charge. | 152.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
7.00 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth in foundation of pole/ laying of under ground cable and including getting out, complete all as specified and as directed by Engineer-in-Charge. | 30.04 | Cum | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
8.00 | M&L sand covering /cushioning for under ground cable protection in-trenches with clean dry sand unwashed including gently pruning around cables complete all as specified and as directed by Engineer-in-Charge. Note:-Punned thickness to be measured for payment. | 10.94 | Cum | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
9.00 | Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil, complete all as specified and as directed by Engineer-in-Charge. | 19.1 | Cum | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
10.00 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed by Engineer-in-Charge. | 10.94 | Cum | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
11.00 | Supply and laying burnt brick sub class 'B' of size 25cm x 12.5cm x 7.5cm locally available best quality laid in trenches for protections of under ground cable, complete all as specified and as directed by Engineer-in-Charge. | 1.08 | Per 1000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
12.00 | Material and labour for Cement concrete 1:3:6(40 mm aggregate) type C2 in foundation filling and mass concrete complete all as specified and as directed by the Engr-in-Charge. | 3.00 | Cum | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
13.00 | Supply, installation, commis-sioning of Water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 20/20 ltrs, complete all as specified and as directed by the Engr-in-Charge. Make: Blue Star, Voltas, Usha . | 10.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
14.00 | M&L for point wiring with 2.5sqmm single core copper conductor cable in PVC casing caping for One 3 pin socket outlet. 15 amps, independent, complete all as specified and as directed by the Engr-in-Charge. | 7.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
15.00 | Supply and fixing MCB 6 to 32 Amps, single pole, 240 Volt "C" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge. | 7.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
16.00 | M&L for Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal, complete all as specified and as directed by the Engr-in-Charge. | 7.00 | Per Point | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
17.00 | Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc, any type of pipe for 15mm bore of pipe including tee,elbows etc, complete all as specified and as directed by Engineer-in-Charge. | 50.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
18.00 | Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for bore dia of 15mm pipe, complete all as specified and as directed by Engineer-in-Charge. | 10.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | ||||||||||||||||||||||||||||||||||||||||||||
Total in Figures | 0.00 | 4 | Construction of chamber for 100mm sluice plates | item5 | 10 | Nos | ||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Figures | Select | 0.0000 | 0.0000 | Zero Only | ||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Words | INR Zero Only |
Andaman & Nicobar Tenders |Andhra Pradesh Tenders |Arunachal Pradesh Tenders |Assam Tenders |Bihar Tenders |Chandigarh Tenders |Chhattisgarh Tenders |Dadra & Nagar Haveli Tenders |Daman & Diu Tenders |Delhi Tenders |Goa Tenders |Gujarat Tenders |Haryana Tenders |Himachal Pradesh Tenders |Jammu & Kashmir Tenders |Jharkhand Tenders |Karnataka Tenders |Kerala Tenders |Ladakh Tenders |Lakshadweep Tenders |Madhya Pradesh Tenders |Maharashtra Tenders |Manipur Tenders |Meghalaya Tenders |Mizoram Tenders |Nagaland Tenders |Odisha Tenders |Pondicherry Tenders |Punjab Tenders |Rajasthan Tenders |Sikkim Tenders |Tamil Nadu Tenders |Telangana Tenders |Tripura Tenders |Uttarakhand Tenders |Uttar Pradesh Tenders |West Bengal Tenders |