Items - PROVISION OF DIRECT ELECTRICAL CONNECTION TO SECURITY CAMERAS AND TELEPHONE NETWORK OPENWELL SUBMERSIBLE PUMP SET, LED COLOURFULL FLOOD LIGHTS A IRDE AND SPL REPAIR/MAINT OF FIRE ALARM, SMOKE SYSTEM IN CERS BUILDING AT DEAL UNDER GE (I) RND DEHRADUN
Item Rate BoQ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BoQ_Ver3.0 | Item Rate | Normal | INR Only | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
Select, Excess (+), Less (-) | Less (-) | |||||||||||||||||||||||||||||||||||||||||||||||||||||
TENDER INVITING AUTHORITY: GARRISON ENGINEER (I) R&D DEHRADUN | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
NAME OF WORK : PROVISION OF DIRECT ELECTRICAL CONNECTION TO SECURITY CAMERAS AND TELEPHONE NETWORK & OPENWELL SUBMERSIBLE PUMP SET, LED COLOURFULL FLOOD LIGHTS AT IRDE AND SPL REPAIR/MAINT OF FIRE ALARM, SMOKE DETECTION SYSTEM IN CERS BUILDING AT DEAL UNDER GE (I) R&D DEHRADUN | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
CONTRACT No: GE(I) R&D/ DDN 52 OF 2025-2026 FILE NO:-9482/E-8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bidder Name : | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sl. No. | Item Description | Item Code / Make | Quantity | Units | Estimated Rate | Addition / Deduction | Addition / Deduction Values | Currency Convertion against each Item | Quoted Currency in INR / Other Currency | RATE In Figures To be entered by the Bidder Rs. P | Excise Duty | VAT | Freight Charges ( Unloading & Stacking) | Any Other Taxes/Duties/Levies | Other Taxes 2 | IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax | Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category | TOTAL AMOUNT Without Taxes | TOTAL AMOUNT In Figures | Rate In Words | ||||||||||||||||||||||||||||||||||
1 | 2 | 3 | 3 | 4 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 5 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 | 51 | 52 | 53 | 6 | 7 |
1 | Supply, fixing & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm, 3 core, 1100 Volts grade through casing-caping or conduit complete, all as specified and directed by Engr-in-Charge. Note: Cable is required for connection to 50 or more different locations with all associated arrangements. | 3000.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
2 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 3 core drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 25mm dia drawing continuous earth wire fijxdx on wall with clamps/saddles complete all as specified and directed by Engr-in-Charge. | 55.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
3 | Supplying and fixing in position Junction box made of SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 100 A Capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator. The gasket should be internally embedded, and made of Polyeutherene. Box shall be suitable for up to 35 Sqmm cables including one no. MCB SP 230 volts 6 amps and connecting the bus bars to cables with using suitable Gl nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5mm Fl clamps, nuts, bolts & washers complete all as specified and directed. | 3.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
4 | Supply, fixing & testing of 50W LED colourfull Flood light (Orange, White & Green) (IP66 Powder coated pressure die cast aluminium High power LED light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on pole or Bldg or ground MS frame/ bracket including connecting the fitting complete all as specified and directed | 16.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 1.02 | Construction of chamber for 100mm sluice plates | item2 | 213 | Nos | |||||||||||||||||||||||||||||||||||||||
5 | Supply, fix & testing of three phase, 2 HP openwell submersible pump set of Suc.x Del. 50x40 mm, 3000 rpm & 60 LPM complete all as specified and directed by Engr-in-charge. Model No: KOS-225M Make: Kirloskar or equivalent | 1.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
6 | Servicing /Checking and upgraded software for Micro processor based 2 wire fault tolerant,networkable type Fire Alarm/Detection Control Panel ( having Nos of loops to suit minimum 20% extra over the Nos of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’ TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. . The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS complete, all as specified and directed. | 1.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 3 | Supplying, Conveying and fixing spls. Including ea | item4 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
7 | Cleaning of All Detectors by Blower will remove dust and other particles that may fault shown in Fire alarm panel and again number match the software of Fire Alarm Panel.Rectified to False alarm During Testing of each Detectors give smoke and address check in panel by area -wise. complete, all as specified and directed. | 134.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
8 | Servicing / Checking of Repeater with Audio Visual Alarm Panel part of Main Fire Alarm Panel complete, all as specified and directed. | 1.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 1.01 | Supplying, Conveying and fixing spls. Including eart | item1 | 123.223 | Nos | |||||||||||||||||||||||||||||||||||||||
9 | Checking of Wiring circuits loop-wise Repeater with Audio Visual Alarm Panel part of Main Fire Alarm Panel complete, all as specified and directed. | 1.00 | Each Job | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 1.02 | Construction of chamber for 100mm sluice plates | item2 | 213 | Nos | |||||||||||||||||||||||||||||||||||||||
10 | Re-locating the Detectors from existing location and Re-fixing where not covering area protection of Detectors complete, all as specified and directed. | 50.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 1.02 | Construction of chamber for 100mm sluice plates | item2 | 213 | Nos | |||||||||||||||||||||||||||||||||||||||
11 | Supply installation commisioning and testing of addressable Detector with fixed and rate of raise feature including mounting base with LED etc complete as required. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector. (Make: Honeywell Morley HM-RHSE+B501, | 10.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
12 | Servicing / Checking of Response Indicator / Manual Call Point / Electronic Hooter /Siren etc cleanning and re-numbering match to Fire Alarm control panel complete, all as specified and directed. | 30.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 3 | Supplying, Conveying and fixing spls. Including ea | item4 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
13 | Supply, installation, testing & commissioning of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully complied to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge Makes : Makes: Morley MI-MCP, | 7.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
14 | Supply, installation, testing & commissioning of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge. Makes :- Honeywell Morley | 7.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
15 | Supply, installation, testing & commissioning of Addressable type Response Indicator with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make: Agni | 10.00 | Each Job | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 1.02 | Construction of chamber for 100mm sluice plates | item2 | 213 | Nos | |||||||||||||||||||||||||||||||||||||||
16 | Supply Installation, Testing & Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work. Make: Glolite | 8.00 | Each Job | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
17 | S& F in repair 2Nos PVC wire 1.5 sq.mm for Fire Alarm system with the following sizes of FRLS insulated copper conductor single core 1100 volts grade cables in existing surface/recessed M.S. conduit etc complete, all as specified and directed. Make Finolex/Havel/Polycab | 200.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
18 | S&F of MS conduit pipe meduim grade of 20 mm dia , ISI marked recessed in wall/ceiling etc. including cost of MS bends , terminal/ inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer -incharge of the work. Make Precision Pipes | 50.00 | RM | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
19 | Supply and fix Battery charger maintenance free Sealed Lead Acid battery capable for minimum 24 hrs operation of 12 V, 7 AH complete all as specified and directed. Make Exide | 2.00 | Each | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | 2 | Construction of chamber for 100mm sluices valve | item3 | 10 | Nos | |||||||||||||||||||||||||||||||||||||||
Total in Figures | 0.00 | 0.00 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Figures | Select | 0.0000 | 0.0000 | Zero Only | ||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Words | INR Zero Only |
Andaman & Nicobar Tenders |Andhra Pradesh Tenders |Arunachal Pradesh Tenders |Assam Tenders |Bihar Tenders |Chandigarh Tenders |Chhattisgarh Tenders |Dadra & Nagar Haveli Tenders |Daman & Diu Tenders |Delhi Tenders |Goa Tenders |Gujarat Tenders |Haryana Tenders |Himachal Pradesh Tenders |Jammu & Kashmir Tenders |Jharkhand Tenders |Karnataka Tenders |Kerala Tenders |Ladakh Tenders |Lakshadweep Tenders |Madhya Pradesh Tenders |Maharashtra Tenders |Manipur Tenders |Meghalaya Tenders |Mizoram Tenders |Nagaland Tenders |Odisha Tenders |Pondicherry Tenders |Punjab Tenders |Rajasthan Tenders |Sikkim Tenders |Tamil Nadu Tenders |Telangana Tenders |Tripura Tenders |Uttarakhand Tenders |Uttar Pradesh Tenders |West Bengal Tenders |