Bidhelp
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE WC AND CE JALANDHAR ZONE - MES||CWE JALANDHAR - MES
E-IN-C BRANCH - MILITARY ENGINEER SERVICES||CE WC AND CE JALANDHAR ZONE - MES||CWE JALANDHAR - MES
CWE Jalandhar Cantt
Punjab QTY :

Items - Repair Maintenance of DG set servicing Changeover switches panels RECDs works and other connected misc works under AGE I Suranussi

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver4.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority: Commander Works Engineer Jalandhar JRC
Name of Work: Repair/Maintenance of DG Set Servicing, Changeover switches/panels RECDs works and other connected misc works under AGE (I) Suranussi.
Contract No: CWE/JAL/S-61/2025-26
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Rs. PExcise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With TaxesTOTAL AMOUNT In Words
1233489101112131451516171819202122232425262728293031323334353637383940414243444546474849505152536547
1.00M&L for servicing of DG Set of capacity 7.5 KVA to 75 KVA complete including draining out of diesel from tank, cleaning the fuel tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, and, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed by Engineer-in-Charge.15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.00M&L for servicing of DG Set of capacity 80 KVA to 200 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed by Engineer-in-Charge.7.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.00M & L in repair the following items from 7.5 KVA to 200 KVA
3.01M & L for Control Safety valve (Water)7.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.02M & L for Volt meter 6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.03M & L for Temp. gauge 5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.04M & L for Amp meter, 6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.05M & L for Lub Oil Pressure gauge 8.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.06M & L for Tachometer (RPM), 7.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.00Supply and fix in repalacement of battery,12 V 180 AH, including testing for its proper functioning as specified and directed by Engr-in-Charge.. Note :- Battery shall be original make accepted No substitute of battery.8.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
5.00Supply and fix in repalacement of battery,12 V 56 AH, including testing for its proper functioning as specified and directed by Engr-in-Charge Note :- Battery shall be original make accepted No substitute of battery.6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
6.00Supply and filling in sump / topping up engine oil, multi grade 10w / 30 and 20w / 40 in engine or relpacement of engine oil .145.00LtrExcess(+)1Full ConversionINR0.000.00INR Zero Only
7.00S& F Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 0.3 mtr long 15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
8.00S& F Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 1.50mtr long 12.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
9.00Supply and fix in repalcement of AVR card suitable for 7.5 KVA to 75 KVA DG Set as per existing.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
10.00Supply and fix in repacement of AVR card suitable for 80 KVA to 125 KVA DG Set as per existing.4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
11.00M & L for Premixed Coolent. 120.00LtrExcess(+)1Full ConversionINR0.000.00INR Zero Only
12.00M & L for distilled water best quality suitable for lead acid battery, complete all as specified and directed by Engineer-in-Charge.130.00LtrExcess(+)1Full ConversionINR0.000.00INR Zero Only
13.00S&F Salient pole type controller winding suitable for 63 KVA to 100 KVA DG set, CPCB -I, as per existing complete all as specified and directed3.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
14.00M&L for servicing, calibration and testing of injector assembly including replacement of worn out parts, barrel, plunger, nozzel, dilivery valve, cup injector and commissioning the same of cap 63 KVA to 200 KVA DG set complete all as specified and directed by Engr-in-Charge.4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
15.00Dismantling of UNSV self starter of cpacity 12/24 volts from engine and shifting to civil workshop for repair/overhauling of the self starter by rewinding of field coil, repair and rewinding of armature and fixing it to the existing place after repairing, complete all as specified and directed by Engr-in-Charge.3.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
16.00Supply and fixing contactor 3 pole 55 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary contact NO/NC complete all as specified and directed by Engr-in-Charge6.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
17.00Supply and fixing contactor 3 pole 80-85 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary contact NO/NC complete all as specified and directed by Engr-in-Charge4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
18.00Supply and fixing contactor 3 pole 160 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary contact NO/NC complete all as specified and directed by Engr-in-Charge5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
19.00 S & F Battery charger sutable for charging ( 12 volts Lead Acid Battery ) electronics type ( SMPS ) with the following meters ( DC Ammeter 0-15 Amps -1 no, D.C Volt meter 0-30 V - 1 no ) fitted either on the door of the control panel or fitted inside a seperate box mounted on panel with all necessary wiring and fixing out put cable upto battery with crocodole clips.11.00jobExcess(+)1Full ConversionINR0.000.00INR Zero Only
20.00S & F for Fuel filter element primary and secondary with 'O' ring and washer for 10 KVA to 200 KVA DG set23.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
21.00S & F for Oil filter element primary and secondary with 'O' ring and washer for DG Set 10 KVA to 200 KVA DG set23.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
22.00S & F Air cleaner element with ring and washer for 10 KVA to 200 KVA DG set23.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
23.00M & L Rubber hose pipe set with clamps for 10 KVA to 200 KVA DG set15.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
24.00S&F in repair, PCB assy complete with display and update software including wring work suitable for DG Set of capacity 30 to 200 KVA.8.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
25.00Repairs of radiator assembly by dismantling from engine and removing the sediments and scales, corrosion etc by means of descaling chemical cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality material for stopping the leakage etc, re-assembling the same with new gaskets, fixing to the engine with hoses, clips complete to the entire satisfaction of engineer - in - charge as required for following DG Sets.
25.017.5/40 KVA DG Set4.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
25.0250/62.5/63 KVA DG Set4.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
25.0375/100 KVA DG Set3.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
25.04125/160 KVA DG Set2.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
26.00Removing old U/S Self starter 12V/24V (Required at site) up to 63 KVA to 200 KVA DG Set , S&F new Self starter of the same type with all necessary modifications including all fittings such as pinion, hardware etc including fixing, testing and commissioning complete all as specified and directed.5.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
27.00M&L for cleaning of diesel tank of DG set of capacity 7.5 to 200 KVA, replacement of diesel measurement scale including painting the tank with two coat of synthetic enamel paint complete all as specified and as directed9.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
28.00Material and labour in replacement broken MS Hinges suitable for Canopy door for any type/capacity of DG SetsLT Panel (as per sample) all as specified and directed by Engr in charge.32.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
29.00M&L for servicing of alternator of any make suitable for DG set by opening the end cover, cleaning the dust and rust formed over the terminals, cleaning with CTC liquid, checking of diodes, winding, isolating transformer and AVR panel and applying paint for insulation improvement over the strips/ winding and drying till getting satisfactory insulation resistance complete, refixing the covers including testing complete all as specified and directed.
29.017.5/40 KVA DG Set3.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
29.0250/63 KVA DG Set4.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
29.0375/100 KVA DG Set3.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
29.04125/200 KVA DG Set4.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
30.00M&L for dismantling and lifting and transportaion, unloading and reinstallation of DG Set from its existing location to a new designated site. the contractor shall disconnect all electrical and fuel connection, safely dismantle the DG set along with its accessories and transport it using suitable equipment and vehicle, all as specified and drected.3.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
31.00Taking out following defective parts from Alternator of DG sets and supply and fixing new parts including testing complete all as directed by Engineer-in-Charge :-
31.01(a) Terminal plate 2.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
31.02(b) Silicon Rectifier assembly with metallic plate as existing covered with thin layer of selnium and insulated nut bolt , control wiring soldering complete3.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
31.03(c) Field excitation unit three phase 415 V for 7.5/200 KVA capacity alternator3.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
31.04(d) Flexible rubber coupling star type capacity alternator coupled with Kirloskar make engine 4.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
31.05(e) Flexible rubber coupling star type capacity alternator coupled with Kirloskar make engine 6.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
31.07(f) Carbon brushes set of four 8.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
31.08(g) Slip rings for 7.5/30/200 KVA (Four rings)9.00Each Excess(+)1Full ConversionINR0.000.00INR Zero Only
32.00Supplying, Fixing, jointing and testing OFF LOAD change over switch 4 pole, 415 volts of current rating .
32.01400 Amps. 1.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
32.02320 Amps. 2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
32.03200 Amps. 2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
32.04100 Amps. 4.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
32.0563 Amps. 5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
33.00M & L for spray Painting of DG Set 30 KVA to 200 KVA with one coat of primer & two coat of superior high quality paint including necessary preparation of surfaces complete all as specified and directed by Engr in charge.8.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
34.00S & F Copper Thimble 10 Sqmm to 35 sqmm all as per specified and directed.45.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
35.00Repair, of 10 KVA UPS card/PCB assy complete with display and update software including wiring work complete fittings for NFS Node all as specified and directed by Engineer in Charge. 1.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
36.00Repair to AMF Panels of 30 KVA to 200 KVA DG set dismanteling/taking down of all electrical connection from unserviceable AMF panel and tpt to local workshop/at site and refixing the same at site after repair works complete all as specified and directed. Note : Spare Parts required for repairing of AMF Panels shall be measured and paid seperately as supply only. 3.00Each JobExcess(+)1Full ConversionINR0.000.00INR Zero Only
37.00Supply & fixing microprocessor controller having auto main failure feature suitable for DG Set 30 to 200 KVA system having following parameter :- (i) Display of RYB phase voltage. (ii) Display of generating voltage. (iii) Display of generator frequency. (iv) Display of main frequency. (v) Display of battery voltage. (vi) Display of single phase current. (vii) Display of generator run hurs 2.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
38.00Supply and fixing MCCB 4 pole 400 Amps, 415 Volts, 50 Hz rupturing capacity 36 KA, thermal magnetic relase, Adjustable type 70-100 % with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.5.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
39.00Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm upto test point and incl Aluminium strip 25x3.15mm from test point to equipment and including GI pipe 40mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm (top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate with 1 nos MS handles of 8mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified.22.00EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
40.00M&L for 60 mm thick precast cement concrete (M-35) factory made, machine pressed interlocking paver blocks, with grey cement and no pigment any shape and size as approved by AGE, laid over and including sand cushion complete all as specified and directed by Engr-in-Charge.75.00Sqm Excess(+)1Full ConversionINR0.000.00INR Zero Only
41.00Material and labour 10 mm thick cement plaster in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.30.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
42.00Supply & Fixing fire retardant/extingushing elect insluted synthetic mat "INSULATICA 2000" OF 2.5 MM THICK Conforming to BIS : DOC NO ET - 02 (5440) Dt 30 Apr 04, meeting requirement of IS : 3043, IS 5216 (Part -1, 2 & 3),IS 8437 and IEC 479 Pub -1, tested for breakdown strength, tensile elongation properties, insulation resistance effect of acid, alkaline, Diesel and DG Oil leakge, current test, etc having a min with of 1000 mm including all pasting matterials such as PU-Resin, chemi bound (hardener), special PVC adhesiv, liquid primer etc suitable for 11000 Voltage systeme and fixed in electrical installation complete alll as directed.)62.00SqmExcess(+)1Full ConversionINR0.000.00INR Zero Only
Total in Figures0.000.00INR Zero Only4Construction of chamber for 100mm sluice platesitem510Nos
Quoted Rate in FiguresSelect0.00000.0000 Zero Only
Quoted Rate in WordsINR Zero Only