Items - REPAIR/MAINT OF FIRE FIGHTING SYSTEM AND CONNECTED WORKS AT CABINET SECTT NBC COMPLEX UNDER GE SOUTH WEST NEW DELHI-03.
Item Rate BoQ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BoQ_Ver3.0 | Item Rate | Normal | INR Only | INR | ||||||||||||||||||||||||||||||||||||||||||||||||||
Select, Excess (+), Less (-) | Less (-) | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Tender Inviting Authority : HQ CWE NO 2 DELHI CANTT-10 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
NAME OF WORK: REPAIR/MAINT OF FIRE FIGHTING SYSTEM AND CONNECTED WORKS AT CABINET SECTT NBC COMPLEX UNDER GE SOUTH WEST NEW DELHI-03. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Contract No : CWE/SW/TOKEN-17/2025-26 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bidder Name : | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sch. item No. | Item Description | Item Code / Make | Quantity | Units | Estimated Rate | Addition / Deduction | Addition / Deduction Values | Currency Convertion against each Item | Quoted Currency in INR / Other Currency | RATE In Rs. | Excise Duty | VAT | Freight Charges ( Unloading & Stacking) | Any Other Taxes/Duties/Levies | Other Taxes 2 | IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax | Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category | TOTAL AMOUNT | TOTAL AMOUNT With Taxes | TOTAL AMOUNT In Words | ||||||||||||||||||||||||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 | 51 | 52 | 53 | 54 | 55 |
1.00 | Supply, laying, fixing and testing in replacement of heavy duty MS Pipe of 200 mm. dia (wall thickness 6.0 mm) conforming to IS: 1239/3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. including welding, cutting, and grinding works, laid in trenches, or fixing in wall, ceiling and floor complete and making good the disturbed surface similar to existing, excavating & providing angle support and painting with two or more coats of synthetic enamel paint of post office red colors per IS- 10221, in and including disconnected/dismantling and taking out of rusty/damaged MS pipes complete all as specified and as directed. | 30 | RM | 0.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
2.00 | All as serial item No 01.00 here in before but of size 150 mm. dia (wall thickness 5.4 mm) | 18 | RM | 1.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
3.00 | All as serial item No 01.00 here in before but of size 100 mm. dia (wall thickness 5.4 mm) | 12 | RM | 2.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
4.00 | All as serial item No 01.00 here in before but of size 80 mm. dia (wall thickness 4.85 mm) | 36 | RM | 3.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
5.00 | Supply, laying, fixing and tested in replacement of heavy duty G.I. pipe 40mm dia conforming to IS: 1239 including fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. in and including cutting, welding and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of post office red color in and including disconnected/dismantling and taking out of rusty/damaged GI pipes complete all as specified and as directed. | 18 | RM | 4.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
6.00 | All as per item srl No. 05.00 here-in-before but 25 mm dia | 24 | RM | 5.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
7.00 | All as per item srl No. 05.00 here-in-before but 20 mm dia | 18 | RM | 6.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
8.00 | Supplying, fixing and testing in replacement of double flanged sluice valve of 200 mm dia rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with matching flange, nuts, bolts, washers, gaskets and conforming to IS: 780 complete all as specified and as directed. | 1 | Each | 7.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
9.00 | All as serial item No 08.00 here in before but of size 150 mm. dia. | 2 | Each | 8.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
10.00 | Supplying, fixing and testing in replacement of double flanged butterfly valve of 200 mm dia ,PN 1.6 rating, CI, gear/hand lever operated, with soft seated wafer, bronze/gunmetal seat and SS 304 shaft duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 complete all as specified and as directed. | 9 | Each | 9.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
11.00 | All as serial item No 10.00 here in before but of size 150 mm. dia. | 7 | Each | 10.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
12.00 | All as serial item No 10.00 here in before but of size 100 mm. dia. | 4 | Each | 11.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
13.00 | All as serial item No 10.00 here in before but of size 80 mm. dia. | 12 | Each | 12.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
14.00 | Supplying, fixing and testing in replacement of unserviceable synthetic fibre circular woven seamless reinforcement jacketed coupling with Type- II (reinforced rubber lined type), flexible fire hose made of 100% synthetic yarn, circular shaped of size 63 mm bore x 15 mtr long, complete with gun metal coupling of 63mm, with multi serrated tail and double instantaneous spring lock arrangement comprising of heavy duty pair of gun metal male and female parts, hydraulically crimped to hose with rubber cap washer and copper binding wire confirming to IS: 903 and ISI marked complete all as specified and as directed. | 75 | Each set | 13.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
15.00 | Supplying, fixing and testing in replacement of unserviceable gun metal branch pipe, short type, instantaneous pattern to suit hose delivery coupling of size 63 mm bore complete with gun metal solid jet nozzle of 20mm nominal size confirming to IS:903 complete all as specified and as directed. | 35 | Each | 14.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
16.00 | Supplying, fixing and testing in replacement of unserviceable fire hydrant flanged type landing valve, oblique type, single outlet with hose coupling adaptor of size 63 mm bore made of stainless steel with female mouth and cast iron wheel and instantaneous spring lock, blank cap with chain confirming to IS:5290 complete all as specified and as directed. | 12 | Each | 15.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
17.00 | Supply and replacement of fire hydrant landing valve of Stainless steel , type 'B' (Double head outlet) of 63 mm bore with isolating valve and instantaneous stainless steel coupling conforming to IS-5290 complete all as specified and as directed. | 22 | Each | 16.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
18.00 | Supplying and installation in replacement yard fire hydrant box, outdoor type of internal size not less than 90cm X 120 cm and 60 cm width, made out of 16 SWG thick CRCA mild steel sheet, factory made, totally enclosed with front side hinged openable cover with locking arrangement and pad lock duly painted with two coat of red post office colour synthetic enamel paint on outside surface and inside surface over a coat of red oxide primer comprising 4 mm thick glass window of size not less than 76 X 76 cm on front side openable cover complete all as specified and as directed. | 14 | Each Job | 17.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
19.00 | All as per Serial No 18 above but indoor type of internal size not less than 90 cm x 60 cm x 50 cm complete all as specified and as directed. | 28 | Each Job | 18.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
20.00 | All as per Serial No 18 above but indoor type of internal size not less than 60 cm x 75 cm x 30 cm complete all as specified and as directed. | 20 | Each Job | 19.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
21.00 | Supply & replace 200 mm dia CI foot valve including necessary rubber gaskets, bolts, nuts and washers complete all as specified and as directed. | 2 | Each | 20.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
22.00 | All as per Ser item No. 21.00 above but 80 mm dia | 2 | Each | 21.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
23.00 | Dismantling centrifugal pump set and motor electrically and transportation to workshop for carrying out the preventive maintenance and repairs by checking and replacing the unserviceable spares such as replacement of shaft, impeller, shaft sleves etc of any make complete with paper & sleeve, wooden stick, 'O' ring set realignment of pump set foundation incl replacement of foundation bolts and nuts, servicing, cleaning and overhauling, lubricating, assembling, connecting and testing complete for the capacity of 15 HP complete all as specified and as directed. Note:- (i) Spares such as gasket, grease, bolt, nuts, studs, flanged and washers, shaft sleeve, bush collar, gland packing, CI gland, key coupling and any kind of welding/lath for refixing/connecting to pipe line etc. are deemed to be included in the cost of servicing. (ii) Bearing and bearing housing block if required to be replaced will be measured &paid separately under relevant items. (iii) Pump/Motors should be returned and fixed after repair within 4 days of intimation of unserviceability. If the same is not reinstalled within the stipulated period then a penalty of Rs. 1000/- per day will be charged. | 2 | Each Job | 22.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
24.00 | Supply only ball bearing as per site requirement of 15 HP pump motor complete all as specified and as directed. | 2 | Each | 23.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
25.00 | Supply only Shaft SS 410 for 15 HP complete all as specified and as directed. | 1 | Each | 24.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
26.00 | Supply only Bronze Impeller (as existing) suitable for centrifugal pump of capacity 15 HP complete all as specified and as directed. | 1 | Each | 25.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
27.00 | Supply only Drive end Bearing housing CI complete all as specified and as directed. | 1 | Each | 26.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
28.00 | Supply only Air release valve as per existing size for 15 HP complete all as specified and as directed. | 1 | Each | 27.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
29.00 | Dismantling centrifugal pump set and motor electrically and transportation to workshop for carrying out the preventive maintenance and repairs by checking and replacing the unserviceable spares such as replacement of shaft, impeller, shaft sleves etc of any make complete with paper & sleeve, wooden stick, 'O' ring set realignment of pump set foundation incl replacement of foundation bolts and nuts, servicing, cleaning and overhauling, lubricating, assembling, connecting and testing complete for the capacity of 120 HP complete all as specified and as directed. Note:- (i) Spares such as gasket, grease, bolt, nuts, studs, flanged and washers, shaft sleeve, bush collar, gland packing, CI gland, key coupling and any kind of welding/lath for refixing/connecting to pipe line etc. are deemed to be included in the cost of servicing. (ii) Bearing and bearing housing block if required to be replaced will be measured &paid separately under relevant items. (iii) Pump/Motors should be returned and fixed after repair within 4 days of intimation of unserviceability. If the same is not reinstalled within the stipulated period then a penalty of Rs. 1000/- per day will be charged. | 2 | Each Job | 28.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
30.00 | Supply only CI centre ring for 120 HP complete all as specified and as directed. | 1 | Each | 29.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
31.00 | Supply only Cast iron bearing housing box complete all as specified and as directed. | 1 | Each | 30.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
32.00 | Supply only CI Impeller with key, stud, MS bolts & nuts for 120 HP as per size requirement (1/2x2",5/8x2.5") MS stud 19x65mm) complete all as specified and as directed. | 1 | Each | 31.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
33.00 | Supply only tyre coupling for 120 HP code no TC /M - 17 complete all as specified and as directed. | 1 | Each | 32.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
34.00 | Supply only gun metal sleeves for 120 HP Pump set complete all as specified and as directed. | 1 | Each | 33.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
35.00 | Supply only cooling fan for 120HP induction motor complete all as specified and as directed. | 1 | Each | 34.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
36.00 | M&L for disconnecting electrically and mechanically defective induction electric motor of capacity 120 HP electrically operated three phase 415 volt, shifting to civil workshop for repair, strip opening for inspection, cutting of unserviceable burnt winding, taking out, cleaning of slots, rewinding with new super enameled ,of existing size of copper conductor winding wire and replacement of unserviceable burnt insulating materials, sleeves etc, varnishing and with two coats of synthetic enamel paint of superior quality after scraping, cleaning and preparation of old painted surfaces complete repainting two cote new and other connected works, re-assembling,re-fixing at site, electrical connection fixing with pump set with nuts,bolts,washers as per original position and testing complete all as directed for satisfactory operation complete all as specified and as directed. Note :- (i) T&P items and any other minor items required for installation and commissioning of electric motor will deemed to be including in the quoted rates. (ii) Any electric connection,nut, bolts, washers, flanges including welding and cutting work will deemed to be including in quoted rates. (iii) Replacement of damage/warnout ball bearing shall be measured and paid separately. | 1 | Each Job | 35.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
37.00 | All as per item srl No. 36.00, here-in-before but of capacity 15 HP | 2 | Each Job | 36.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
38.00 | M&L for by doing patch work in cement mortar 1:4 for inside and out side plastering ,taking out old rusted chamber cover and replacement of new MS plate 3 mm thickness with angle, hinges arrangement for suitable valve chamber 4"/6"/8" size including painting for repairs of valve chamber complete all as specified and as directed. | 4 | Each Job | 37.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
39.00 | Material and labour for scrubbing out the rust deposited on the surface of centrifugal pump set including its base frame and preparing surface for applying paint and applying one coat of redoxide primer and two coat of synthetic enamel paint for capacity of pump set 15 to 120 HP complete all as specified and as directed. | 7 | Each Job | 38.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
40.00 | M&L for applying one coat of synthetic enameled spray paint of existing colour on steel/iron surfaces of pipes, LT panel boards etc with and incl preparing of surface by scratching / removing rust, dust and old paints etc with wire brush, emery paper, grinder etc and making surfaces smooth for achieving better grip between surface and primer, complete all as specified and as directed. | 3 | Each Job | 39.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
41.00 | S&F in replacement of deluge valve assembly complete set with all connected accessories, fitted in 150 mm basement riser line properly in original location checking and making proper all connections, testing for smooth operating complete all as specified and as directed. | 1 | Each | 40.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
42.00 | Supplying and fixing in replacement of unserviceable Pressure switch in and including pvc insulated copper conductor FRLS flexible cable with copper thimble of suitable size upto control panel complete all as specified and as directed. | 6 | Each | 41.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
43.00 | Supply & fix in replacement Flow switch of dia 150/200 mm as per existing specification complete all as specified and as directed. | 4 | Each | 42.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
44.00 | Supplying, fixing and testing in replacement of unserviceable swinging hose reel with drum comprising of ply rubber hose of size 20mm(3/4"), 15m long tested with 25kg/cm²/350 psi bursting pressure with wall mounted mild steel pressel reel with 180º angle swinging with non-jamming controlling handle which shall stay at the ON/OFF position as set, wall bracket with 'U' shaped reel carrier made of CI of post office red colour finish in and including gun metal noel and shut off ball valve, heavy duty confirming to IS: 884 and ISI marked complete all as specified and as directed. | 16 | Each | 43.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
45.00 | Supplying and fixing in replacement of unserviceable internal hydrant rubber washer 4mm thick of size 12mm inner diameter and 72mm outer diameter complete all as specified and as directed. | 120 | Each | 44.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
46.00 | M&L for replacement of U/S Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating concealed type complete all as specified and as directed. | 300 | Each | 45.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
47.00 | Supply and fix in replacement brass body, open head type automatic sprinkler water deluge type arrangement) head, set with detector, including fixing arrangement to operate at specified temperature, of following types:- (i)Type- pendent type, (ii) Size: 15 mm dia, (iii) Finish: Brass, (iv) Operating temp- 57° C complete all as specified and as directed. | 25 | Each | 46.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
48.00 | Supply & fixing in replacement of broken glass window size not less than 76 cm x 76 cm x 4 mm thick in yard fire hydrant box inscribed with word 'FIRE' with red post office colour synthetic enamel paint as per existing pattern complete all as specified and as directed. | 15 | Each Job | 47.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
49.00 | M&L for fittings for flanged pipes such as Bends, Tapers, Tee Pieces (Single & double branch) any type and angle/radios and straight connecting pieces but all ends flanged complete all as specified and as directed. | 150 | KG | 48.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
50.00 | M&L for dismantling and taking down corroded/worn out base frames/pit covers, any type of water supply/fire fighting installations and supply and fix new base frames/pit covers. MS angle iron frame /MS plates/MS flat or round bars including welding work, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. | 120 | KG | 49.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
51.00 | M&L for painting up to 200 mm bore New MS/GI pipe with one coat of red oxide primer and two coats of red post office synthetic enamel paints on all external steel surface after thoroughly cleaning/scraping of old paints, rust and scale etc, before applying the primer complete all as specified and as directed. | 600 | Sqm | 50.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
52.00 | M&L for painting of MS fire hydrant box Indoor/outdoor type of internal size not less than 90cm X 200 cm and 60 cm after thoroughly cleaning/scraping of old paints, preparation of surfaces with emery paper as per existing colour code duly painted with two coat of red post office colour synthetic enamel paint on front of outside surface and inside surface over a coat of red oxide primer comprising 4 mm thick glass window complete all as specified and as directed. | 60 | Each Job | 51.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
53.00 | Supply and fix Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of 4 way 63mm dia instantaneous type male coupling with built in check valves 150mm dia, flanged outlet complete with all accessories complete all as specified and directed | 3 | Each | 52.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
54.00 | Supply & fixing in renewal dial type Pressure gauge with isolation cock at hydrant station of 150 mm dia and calibration 4'' dial ,0-14 Kg/Sqcm complete all as specified and as directed. | 15 | Each | 53.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
55.00 | Supply and replacement gun metal 3/4" shut off nozzle with clamp for tighten in hose reel suitable for 20mm hose complete all as specified and directed | 25 | Each | 54.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
56.00 | Supplying and fixing in replacement of unserviceable hydrant PVC valve cap with SS chain of size 63mm, round shape, pull and push type complete all as specified and as directed. | 36 | Each | 55.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
57.00 | Repairing/ Servicing of 63/100 mm dia fire hydrant valve single/ double headed (type 'A' & 'B") with iron hand wheel by replacing seat, Neoprene 'O' rings, spring loaded side locks, outlet hose coupling adaptor of size 63 mm including renewal of necessary bolts/nuts/washers complete all as specified and as directed. | 40 | Each | 56.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
58.00 | Supply and fix 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to iron pipe complete including taking down old unserviceable complete all as specified and as directed. | 5 | Each | 57.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
59.00 | Supply and Fixing in repair rubber hose reel 30 mtr, 20mm dia plain 2 ply rayon braided high pressure with gun metal nozzle ccomplete all as specified and as directed. | 25 | Each | 58.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
60.00 | S&F in replacement of Phase indicating lamp, LED type, RED/BLUE/YELLOW /GREEN, 22.5 mm dia, surface mounted, 240VAC suitable for panel mounting complete all as specified and as directed. | 10 | Each | 59.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
61.00 | S&F in replacement of DOL starter 15 HP 3 Phase 415 V complete all as specified and as directed. | 1 | Each | 60.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
62.00 | Supply and fix in replacement Digital Volt-ammeter 500V, 3 phase complete all as specified and as directed. | 6 | Each | 61.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
63.00 | Supply and fix in replacement Digital ammeter CT secondary site selectable 1A / 5A, 3 phase complete all as specified and as directed. | 6 | Each | 62.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
64.00 | S&F in replacement of Electronic motor protection relay as per existing specification complete all as specified and as directed. | 2 | Each | 63.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
65.00 | S&F in replacement of 3 pole power contactor, 3 phase, 415 volts, 50 Hz including front mounting add-on auxiliary contact block Model No. MNX 40, complete all as specified and as directed. | 8 | Each | 64.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
66.00 | S&F in replacement single phasing preventer & dry run protection relay current type with multifunction meter as per site requirement complete all as specified and as directed. | 3 | Each | 65.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
67.00 | Disconnecting the existing unserviceable /burnt MCCB from the LT panel and Supply & fixing new MCCB ,TP , 400 Amp, 36 KA, 415 volt,50 Hz, 3 phase, Ics=100% of Icu with thermal magnetic release, installation of MCCB and connecting with existing cable including nut, bolt and washer etc complete all as specified and as directed. | 2 | Each | 66.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
68.00 | All as serial item No 67 here in before but of size 350 Amp, 36 KA | 2 | Each | 67.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
69.00 | All as serial item No 67 here in before but of size 160 Amp, 36 KA. | 1 | Each | 68.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
70.00 | All as serial item No 67 here in before but of size 125 Amp, 16 KA. | 2 | Each | 69.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
71.00 | All as serial item No 67 here in before but of size 100 Amp, 16 KA . | 3 | Each | 70.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
72.00 | All as serial item No 67 here in before but of size 400 Amp, 4 pole, 36 KA | 1 | Each | 71.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
73.00 | All as serial item No 67 here in before but of size 40-100 Amp, TPN, 10 KA. | 2 | Each | 72.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
74.00 | S & F in replacement of MCB SP 6-32 Amp, C-curve, 10 KA. | 6 | Each | 73.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
75.00 | S & F in replacement of MCB SPN 32 Amp, C-curve, 10 KA | 4 | Each | 74.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
76.00 | S & F in replacement of MCB SPN 40-63 Amp, C-curve, 10 KA | 2 | Each | 75.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
77.00 | S & F in replacement of MCB TP 63 Amp, C-curve, 15/10 KA | 4 | Each | 76.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
78.00 | Periodical maintenance of Diesel Engine set, complete oil servicing, incl cleaning of diesel tank and radiator as recommended by manufacturer and necessary replacement of below mentioned spares and servicing work for DG Set of capacity upto 127HP/ 94 KVA for servicing complete all as specified and as directed. (a) Diesel Filter (Pre+micro) (b) Engine Oil filter (c) filling Engine Oil UTL (d) filling Radiator Coolant (e) Battery terminal with sockets | 2 | Each Job | 77.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
79.00 | Supply only distilled water in sealed packing suitable for DC 12 volt battery complete all as specified and as directed. | 20 | Ltrs | 78.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
80.00 | S&F in replacement, battery 12 V 180 AH as given in tender documents complete all as specified and as directed. | 2 | Each | 79.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
81.00 | Supplying, fixing and testing air vessel made of 300mm to 450 mm dia, 8 mm thick MS sheet, 1000 mm in height complete with air release valve on top and flanged connection to riser with gun metal shut off valve at the inlet, drain arrangement with 25 mm dia gun metal drain valve with required accessories, stainless steel pressure gauge and 3 nos mild steel supporting legs in and including painting with synthetic enamel paint of post office red coloured over two coat of red oxide primer on outside and two coat of epoxy coat in in inside complete all as specified and as directed. | 5 | Each | 80.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
82.00 | M&L for taking out/ collected empty Fire Extinguishers of any type and capacity from various locations send to authorized distributor for refilling and re-fixing the same in proper position and location as per the requirement of the location and type of fire extinguisher in and including transportation complete all as specified and as directed. | 122 | Each Job | 81.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
83.00 | Refilling of 06 Kg ABC Powder type modular Fire Extinguishers with ABC dry chemical powder with fresh/sufficient quantity/quality, ABC Dry chemical powder as per IS: 14609:1999 and shall contain 90% Mono Ammonium Phosphate and pressurized with Nitrogen Gas in and including painting the cylinder, labeling/marking with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities, a dry chemical Hydraulic Pressure testing should be as per IS-2190-2010 and test certificate shall be submitted complete all as directed . Note: Any fire extinguisher cylinder will be failing in hydraulic test will be return in AGE E/M Cab Sectt yard and nething extra will be paid for its to the contractor. | 40 | Each Job | 82.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
84.00 | All as serial item No 83 here in before but of size 4 Kg ABC Powder type Fire Extinguishers | 15 | Each Job | 83.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
85.00 | All as serial item No 83 here in before but of size 2 Kg ABC Powder type Fire Extinguishers | 10 | Each Job | 84.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
86.00 | Refilling of 4.5 Kg Carbon dioxide (CO2) type Fire Extinguishers with Carbon dioxide (CO2) and pressurization of fire extinguisher with fresh/sufficient quantity/quality, Carbon dioxide shall be as per IS: 15222:2002 with minimum gas purity shall be 99.5 % in and including painting the cylinder, labeling/marking with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities, Carbon dioxide fire extinguishers shall be tested as per IS: 5844-1970 and test pressure shall be 250 kg/ cm2 (as per the IS 2190:2010 ) and test certificate shall be submitted complete all as directed . Note: Any fire extinguisher cylinder will be failing in hydraulic test will be return in AGE E/M Cab Sectt yard and nothing extra will be paid for its to the contractor. | 55 | Each Job | 85.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
87.00 | All as serial item No 86 here in before but of size 22.5 Kg Carbon dioxide (CO2) trolley mounted complete all as specified and as directed. | 2 | Each Job | 86.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
88.00 | Supply & fixing in replacement of U/S discharge valve wheel type with working pressure 158 Kg/cm² confirming to IS: 3224 suitable for CO2 type fire extinguishers of capacity 4.5 Kg and 2 Kg complete all as specified and as directed. | 10 | Each | 87.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
89.00 | Supply & fixing in replacement of U/S discharge hose made out of wire braided rubber of ID 10mm and 1 mtr long, confirming to IS: 3224 suitable for CO2 type fire extinguishers of capacity 4.5 Kg complete all as specified and as directed. | 10 | Each | 88.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
90.00 | Supply & fixing in replacement of U/S discharge horn made out of figer glass/polyethylene, non- conductor of electricity with suitable handle, confirming to IS: 3224 suitable for CO2 type fire extinguishers of capacity 4.5 Kg complete all as specified and as directed. | 12 | Each | 89.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
91.00 | Supply & fixing in replacement of U/S taflon/nylon washer with OD-19mm, ID- 9mm and thickness 3mm complete all as specified and as directed. | 1 | Kgs | 90.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
92.00 | Supply & fixing in replacement of U/S squeeze grip type valve, heavy duty with MS control handle and ss lock/pull pin with chain confirming to IS: 15683 (2006) suitable for ABC type fire extinguishers of capacity 06 Kg, 4 Kg and 2 Kg complete all as specified and as directed. | 18 | Each | 91.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
93.00 | Supply & fixing in replacement of U/S discharge wire braided rubber hose with brass shut off nozzle, length of the flexible hose not less than 400mm, confirming to IS: 15683 (2006) suitable for ABC type fire extinguishers of capacity 06 Kg, 4 Kg and 2 Kg complete all as specified and as directed. | 25 | Each | 92.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
94.00 | Supply & fixing in replacement of U/S analog type spring brass fire extinguisher pressure gauge, 1" dial suitable for measuring 0 to 50 bar duly calibrate by standard method confirming to IS: 15683 (2006) suitable for ABC type fire extinguishers of capacity 06 Kg, 4 Kg and 2 Kg complete all as specified and as directed. | 20 | Each | 93.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
95.00 | S&F in replacement of fire extinguisher mounting bracket suitable upto 2 kg to 10 kg cylinders duly fixed in wall with MS fastener/GI Screw complete all as specified and as directed. | 55 | Each | 94.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
96.00 | S&F in replacement of 3 pole Power contactor MNX-110, 3 phase, 415 volts, 50 Hz for star delta starter suitable of 120 HP pump complete all as specified and as directed. | 6 | Each | 95.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
97.00 | S&F in replacement of 3 pole MNX-A2 Power contactor, 3 phase, 415 volts, 50 Hz for star delta starter suitable of 20 HP pump including front mounting add-on auxiliary contact block complete all as specified and as directed. | 6 | Each | 96.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
98.00 | S&F in replacement of 3 pole MNX-A1 Power contactor, 3 phase, 415 volts, 50 Hz for star delta starter including front mounting add-on auxiliary contact block complete all as specified and as directed. | 3 | Each | 97.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
99.00 | S&F in replacement of 3 pole power contactor, 3 phase, 415 volts, 50 Hz including front mounting add-on auxiliary contact block Model No. MNX 50, complete all as specified and as directed. | 4 | Each | 98.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
100.00 | S&F in replacement of Overload relay with trip class 30 suitable for range 250 Amp Max, complete all as specified and as directed. | 4 | Each | 99.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
101.00 | S&F in replacement of Overload relay suitable for range 63 Amp Max, complete all as specified and as directed. | 4 | Each | 100.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
102.00 | S&F sprinkler flexible metal pipe 25mm dia, 1 meter length with connected accessories for shifting sprinkler to false celling complete all as specified and as directed. | 300 | Each | 101.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
103.00 | Supplying and fixing in replacement of unserviceable 63mm dia CI hydrant valve hand wheel, round shape, with bolt, nut & washer complete all as specified and as directed. | 35 | Each | 102.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
104.00 | M&L for painting of Air vessels with one coat of red oxide primer and two coats of red post office synthetic enamel paints on all external steel surface after thoroughly cleaning/scraping of old paints, rust and scale etc, before applying the primer complete all as specified and as directed. | 12 | Each Job | 103.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
105.00 | Supplying and fixing in replacement of unserviceable gun metal air release valve with GI coupling of Air vessels of size 25 mm, screwed type complete all as specified and as directed. | 4 | Each | 104.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
106.00 | Supplying and fixing in replacement of unserviceable forced brass ball valve for inlet & drain of Air vessels of size 20 mm, screwed type complete all as specified and as directed. | 4 | Each | 105.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
107.00 | S&F in replacement of ammeter selector switch , suitable for line current with neutral and OFF (5 position), AC ,three phase suitable for panel mounting complete all as specified and as directed. | 3 | Each | 106.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
108.00 | S&F in replacement of voltmeter selector switch , suitable for voltage between phase to phase and individual phases to neutral with OFF (7 position), AC ,three phase suitable for panel mounting complete all as specified and as directed. | 3 | Each | 107.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
109.00 | S&F in replacement of Tyre coupling TC 11/12 suitable for 15 HP centrifugal Pump set made out of FRAS neoprene rubber tyre and steel hub with nuts & bolts complete all as specified and as directed. Note: Contractor should check the existing pump shaft size at site before procurement of tyre coupling. | 1 | Each | 108.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
110.00 | Supplying, fixing and testing in replacement of double flanged non return valve of 200 mm dia, PN 1.6 rating, bronze/gunmetal seat and ss 304 shaft duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes complete all as specified and as directed. | 2 | Each | 109.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
111.00 | All as serial item No 110 here in before but of size 150 mm dia. | 1 | Each | 110.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
112.00 | All as serial item No 110 here in before but of size 100 mm dia. | 3 | Each | 112.0000 | Excess(+) | 1 | Full Conversion | INR | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||
Total in Figures | 0.00 | 0.00 | INR Zero Only | |||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Figures | Select | 0.0000 | 0.0000 | Zero Only | ||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted Rate in Words | INR Zero Only |
Andaman & Nicobar Tenders |Andhra Pradesh Tenders |Arunachal Pradesh Tenders |Assam Tenders |Bihar Tenders |Chandigarh Tenders |Chhattisgarh Tenders |Dadra & Nagar Haveli Tenders |Daman & Diu Tenders |Delhi Tenders |Goa Tenders |Gujarat Tenders |Haryana Tenders |Himachal Pradesh Tenders |Jammu & Kashmir Tenders |Jharkhand Tenders |Karnataka Tenders |Kerala Tenders |Ladakh Tenders |Lakshadweep Tenders |Madhya Pradesh Tenders |Maharashtra Tenders |Manipur Tenders |Meghalaya Tenders |Mizoram Tenders |Nagaland Tenders |Odisha Tenders |Pondicherry Tenders |Punjab Tenders |Rajasthan Tenders |Sikkim Tenders |Tamil Nadu Tenders |Telangana Tenders |Tripura Tenders |Uttarakhand Tenders |Uttar Pradesh Tenders |West Bengal Tenders |