General Manager (Commercial)
Maharashtra QTY :

Items - CONSTRUCTION OF BOYS HOSTEL UNDER EWS SCHEME IN THE PREMISES OF DR. SHANKARRAO CHAVAN MEDICAL COLLEGE IN NANDED IN MAHARASHTRA UNDER DMER, GOVT. OF MAHARASHTRA, MUMBAI

Tender Details
Costs
Documents
BOQ

BoQ1

Percentage BoQ At Par
BoQ_Ver4.0PercentageNormalINR OnlyINR
Select, At Par, Excess (+), Less (-)IOCLSelectExcess (+)Less (-)At Par (=)
Tender Inviting Authority : BRIDGE AND ROOF CO. (INDIA) LIMITED., KANKARIA CENTRE, 4TH & 5TH FLOOR, 2/1, RUSSEL STREET, KOLKATA - 700071
Name of Work : “CONSTRUCTION OF BOYS HOSTEL UNDER EWS SCHEME IN THE PREMISES OF DR. SHANKARRAO CHAVAN MEDICAL COLLEGE IN NANDED IN MAHARASHTRA UNDER DIRECTORATE OF MEDICAL EDUCATION AND RESEARCH, GOVT. OF MAHARASHTRA, MUMBAI”. Sub Head: Civil Work including Electrical work, Sanitary & Plumbing, Water Supply, Landscaping, HVAC, Fire-Fighting including Fire Protection, STP/ ETP and other Allied Works, etc.
Notice Inviting e-Tender (eNIT) No : B AND R / HO / DMER / 51276 / MAHARASHTRA / NANDED / NIT / CW / 01, DATED 06.08.2025
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsUnit Rate in Rs. PAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Rs. P TOTAL AMOUNT in Figure Rs. PTOTAL AMOUNT in Figure Rs. PTOTAL AMOUNT In Words
12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455
1.00CONSTRUCTION OF BOYS HOSTEL NANDEDItem11Construction of chamber for 100mm sluices valveitem1101 Nos
2.00CONSTRUCTION OF BOYS HOSTEL UNDER EWS SCHEME IN THE PREMISES OF DR. SHANKARRAO CHAVAN MEDICAL COLLEGE IN NANDED IN MAHARASHTRA UNDER DIRECTORATE OF MEDICAL EDUCATION AND RESEARCH, GOVT. OF MAHARASHTRA.Item21.00Total Value275,661,487.36Excess(+)1Full ConversionINR275661487.36275661487.36INR Twenty Seven Crore Fifty Six Lakh Sixty One Thousand Four Hundred Eighty Seven & Paise Thirty Six Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
3.00"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."Item61.02Construction of chamber for 100mm sluice platesitem2213Nos
Total in Figures275661487.36275661487.36INR Twenty Seven Crore Fifty Six Lakh Sixty One Thousand Four Hundred Eighty Seven & Paise Thirty Six Only4Construction of chamber for 100mm sluice platesitem510Nos
Quoted Rate in FiguresSelect0.000.00INR Zero Only
Quoted Rate in WordsINR Zero Only

HOSTEL-BOYS

Tender Inviting Authority : BRIDGE AND ROOF CO. (INDIA) LIMITED., KANKARIA CENTRE, 4TH & 5TH FLOOR, 2/1, RUSSEL STREET, KOLKATA - 700071
NAME OF WORK: “CONSTRUCTION OF BOYS HOSTEL UNDER EWS SCHEME IN THE PREMISES OF DR. SHANKARRAO CHAVAN MEDICAL COLLEGE IN NANDED IN MAHARASHTRA UNDER DIRECTORATE OF MEDICAL EDUCATION AND RESEARCH, GOVT. OF MAHARASHTRA, MUMBAI”. Sub Head: Civil Work including Electrical work, Sanitary & Plumbing, Water Supply, Landscaping, HVAC, Fire-Fighting including Fire Protection, STP/ ETP and other Allied Works, etc.
Notice Inviting e-Tender (eNIT) No : B AND R / HO / DMER / 51276 / MAHARASHTRA / NANDED / NIT / CW / 01, DATED 06.08.2025
Name of the Bidder/ Bidding Firm / Company :
Intended rates
Sr. No.ReF No.Description oF ItemUnit Quantity Rate Amount
Civil work
EARTH WORK
12.28Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
2.28.1All Kinds of SoilSqm2,104.0029.2961,626.16
22.09Clearing and grubbing Builidng / road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. Sqm2,103.0012.4826,245.44
321.34Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. completeSqm1,504.006.249,384.96
421.02Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto adistance of 50m. be yond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical MeansCum1,193.00215.28256,829.04
521.04Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto adistance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5-3.0 m.) By Mechanical MeansCum1,193.00268.32320,105.76
521.06Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical MeansCum755.00236.08178,240.40
621.10Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical MeansCum371.00262.0897,231.68
721.12Excavation for foundation in Hard murum and boulders including removing the excavated material upto adistance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical MeansCum1,175.00324.48381,264.00
821.16Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical MeansCum770.00544.96419,619.20
921.17Excavation for foundation in Hard rock by blasting including trimming and leveling the bed by chiseling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum, watering, ramming, etc. complete. (Lift upto 1.5m) By Mechanical MeansCum616.00903.76556,716.16
1021.18Excavation for foundation in Hard-rock by blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramming etc. complete. (Lift from 1.5m To 3.0 m) By Mechanical MeansCum616.001,074.32661,781.12
1121.19Excavation for foundation in Hard-rock by controlled blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres. from the building area including dewatering and back filling with available earth soil /murum watering, ramming etc. complete. (Lift upto 1.5m) By Mechanical MeansCum349.001,374.88479,833.12
1221.20Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 m). By Mechanical MeansCum349.001,359.28474,388.72
1321.36Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.Cum716.00124.8089,356.80
1421.37Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15cm to 20cm including watering and compaction etc. complete.Cum4,067.00622.962,533,578.32
1521.39Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer)Cum168.002,246.40377,395.20
1621.40Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.Cum206.001,512.16311,504.96
1721.29Providing antitermite treatment around the periphery of the existing building as per I.S. 6313 (Part-III) by excavating trenches of 20cm width and exposing the sides of columns and plinth beams upto a depth of 300mm and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per One Running Metre and refilling the trenches etc. complete covering 2 years guarantee on bond paper.Mtrs.147.0069.6810,242.96
1821.25Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.Sqm1,284.00183.04235,023.36
19DSR 2.24Extra rates for quantities of works, executed:
i2.24.1In or under water and/or liquid mud, including pumping out metre water as required (Depth upto 1.5 m.)metre depth2,103.0043.0690,555.18
ii2.24.1In or under water and/or liquid mud, including pumping out metre water as required (Depth upto 1.5 to 3.0 m.)metre depth2,103.0053.66112,846.98
Note for item no. 2.24:-The extra percentage rate is applicable in respect of each item but limited to quantities of work executed in these difficult conditions. The unit, namely, metre depth, to be considered for payment, shall be the depth measured from the sub soil water level up to the centre of gravity of the qty executed in difficult conditions. The depth shall be reckoned correct to 0.10 m, 0.05 m or more shall be taken as 0.10 m and less than 0.05 m ignored
20DSR 2.27Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.Cum168.001,821.31305,980.08
CONCRETE WORK
2124.01Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum95.006,063.20576,004.00
2224.04Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum235.006,613.361,554,139.60
2324.06Providing and laying Cast in situ/Ready Mixcement concrete in M20 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum9.006,989.8462,908.56
2424.10Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum1.006,989.846,989.84
2514.34Providing and laying in situ / ready mix 1:4:8 cement concrete of trap /granite /quartzite /gneiss metal for haunch filling including compacting, curing, mixing etc. complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) with fine agreegates of required specifications ( VSI sand finely washed etc )Cum102.005,482.88559,253.76
2649.28Providing and fixing stainless steel bollard of steel pipe 1.00 metre long of 250 mm inner diameter and circular top plate of 350 mm diameter with 5 mm thickness on deck of jetty in cement concrete including necessary fixtures and fastening etc. complete. (Stainless steel of grade S-304)Each2.0021,707.9243,415.84
2731.01Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete.Sqm28.00449.2812,579.84
28DSR 4.12Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.per 50 Kg cement45.0015.57700.65
29DSR 4.17Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.Sqm132.00642.5984,821.88
R.C.C WORK
3026.46Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 50 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both side, fixing in cement mortar 1:3 and curing etc. completeSqm4.00974.483,897.92
3126.33Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.MT540.0093,291.1250,377,204.80
325.30Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.Rmt1,883.0067.24126,612.92
3325.13Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum179.007,578.481,356,547.92
3425.33Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum77.0014,525.681,118,477.36
3525.15Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum1,205.007,769.849,362,657.20
3625.35Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum376.0014,716.005,533,216.00
3725.52Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum849.0012,950.0810,994,617.92
3825.72Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum1,023.0014,680.6415,018,294.72
3912.59Providing and laying in situ / ready mix controlled grade of M25 of trap /granite /quartzite /gneiss metal for RCC works in cut off walls / curtain walls including necessary scaffolding, centering, compacting by vibrator, finishing and curing etc. complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) with fine agreegates of required specifications ( VSI sand finely washed etc ), excluding reinforcement)Cum90.008,339.76750,578.40
4026.07Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum29.0014,680.64425,738.56
4126.26Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap / quartzite / granite / gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honey combed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finishis to be provided and curing etc. complete. (Excluding reinforcement, including cover block) . (Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic microprocess or based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum53.0012,733.76674,889.28
425.44Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning I self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self- centering arrangement that freely rotates I moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063).
5.44.1Floor Joint of 100 mm gapMtrs.32.005,482.19175,430.08
435.45Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning I centering arrangement and support plates as per ASTM 8221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to comer application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint Systemshall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063).
5.45.1Wall Joint of 100 mm gapMetre96.004,550.08436,807.68
445.46Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self-centering arrangement that freely rotates I moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement.The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063).
5.46.1Roof Joint of 100 mm gapMtrs.34.005,133.28174,531.52
45NSIConstruction of Boundary Wall with Precast & Prestressed Concrete (1:1.5:3) Panel of Size 2.40x0.30x0.05 Mtr. And Column 0.15x0.15x2.70 Mtr. (2.10 Mtr. above Ground Level and 0.60 Mtr. Below G.L.) including fixing of Panel in Column, Cost of all material labour and T&P etc. required for proper completion of work but excluding Excavation & C.C. for grouting of column.Mtrs.61.009,526.40581,110.40
MASONRY WORK
4627.01Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.Cum62.008,065.20500,042.40
4727.13Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. CompleteCum695.007,390.245,136,216.80
4827.16Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Sqm428.001,067.04456,693.12
4927.14Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete.Sqm1,945.001,052.482,047,073.60
5027.15Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Cum706.007,633.605,389,321.60
CLADDING WORK
5133.22Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, moulding edges, polishing,cleaning complete. b) GraniteSqm404.004,041.441,632,741.76
5233.26Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.Sqm1,180.001,329.121,568,361.60
WOOD WORK
5339.74Providing and fixing fly proof mesh shutter to ventilator / window using CCTW members of size 45 x 22 mm for frame work and 35 x 22 mm for middle support and fixing fly proof mesh on it and covering TW battens of size 20 x 10 mm including priming and two coats of oil painting to the new wood and steel work and all labour charges including all fixture and fastenings etc. completeSqm536.003,120.001,672,320.00
5440.01Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting withone coats of anticorrosive paint and two coats of oil painting complete.Sqm572.002,180.881,247,463.36
5540.03Providing and fixing mild steel grill railing 20 Kilogram/sq.m with teak wood hand rail of size 75mm x 60 mm.and sill of 75mm.x 25 mm.and newel posts for staircases, including fabricating, fix-tures, erecting, painting the grill work with one coat of anti-corrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish.Sqm2.003,299.926,599.84
5639.01Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. completeCum2.00208,052.00416,104.00
5751.169FireDoor55mm2HRFRL(120/120)3Criteria-INTEGRITY/INSULATION/STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. Providing of 120 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature").
a) Door Frame: Supplying & Fixing frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 Kilogram/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete.Rmt68.001,912.56130,054.08
5851.170FireDoor55mm2HRFRL(120/120)3Criteria-INTEGRITY/INSULATION/STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. Providing of 120 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature").
b)Shutter : Supplying & Fixing of 55mm thick asbestos free criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 Kilogram/cum) frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128 Kilogram/cum), vermaculite mix faced with 3mm Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10mmx4mm affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping.Sqm40.0011,028.16441,126.40
5951.171c) Vision Panel: 2 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 mm inside the shutter on all sides with U- glazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints.Sqm2.0059,443.28118,886.56
6051.175Panic Bar: (For 2 Hr fire Rated single Panic bar) Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style ,made of heavy duty cast iron/ steel body & latches with SS ,BHMA certified & conforming to ANSI A 156.3 for grade-1 ( 3 hours fire rated ) and suitable for surface mounting to wooden/ hollow metal/ Al framed door,with maximum operating force 8 Kilogram for unlocking easily & outwardly during emergency, complete in all respect as per direction & satisfaction of Engineer-in charge including all taxes & incidental charges. (Note: To be installed at "FIRE EXIT"only under location specific instruction of Eingineer-in -Charge.) Each59.0010,596.56625,197.04
6151.176Door Closure: (For 2 Hr fire Rated EN-3 Door Closure) Supplying ,fitting & fixing Surface mounted over head Door Closer for 2 hour fire rated doors of different size (e.g size-EN-3 for leaf width upto 900mm) CE certified, marked & conforming to EN-1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnumetc.) fitted and fixed Complete as per direction & satisfaction of Engineer -in Charge including all taxes & incidental charges.Each34.004,064.32138,186.88
6251.17712"SS Handle: (For 2 Hr fire Rated 12"SS Handle) Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.)as per direction of Eingineer -in Charge fitted and fixed complete including all taxes & incidental charges.Each59.002,122.64125,235.76
6354.09Providing and fixing of factory made uPVC casement window / Fixed Window & Casement Door (White Colour) comprising uPVC multi-chambered frame, Sash, & Mullion with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. EPDM / TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 mm Float Annealed glass shall be provided in the sash with the help of uPVC glazing bead and hardware, i.e., friction hinge & single point handle (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.
iaCasement Window (Big Series) frame of size 67 x 62 mm & Sash / Mullion of size 67 x 78 mm.Sqm147.0010,914.801,604,475.60
iibCasement Door (Big Series) frame of size 67 x 62 mm & Door Sash of size 67 x 115 mm & Mullion (if required) of size 67 x 78 mm. Sqm479.009,964.244,772,870.96
iiicFixed Window (Big Series) frame of size 67x62mm & Mullion (if required) of size 67x78 mm.Sqm12.008,675.68104,108.16
STEEL WORK
6423.01Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.MT6.00105,917.76635,506.56
6523.04Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.MT1.00124,237.36124,237.36
6623.07Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge.MT1.00119,424.24119,424.24
6737.21Providing and fixing shutter to wall cupboard made from 19 mm thick Teak particle board with approved coloured laminated face 1.5 mm thick bonded with phenol formaldehyde synthetic resin B.W.P. grade including lipping beading iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame).Metre120.003,679.52441,542.40
6839.36Providing and fixing steel frame door of angle 40x40x5mm with 16mm dia. Mild steel bars horizontally at 10cmc/c for ventilator portion including iron hold fast for the fixing shutters including welding, painting, finishing etc. complete.Metre196.001,820.00356,720.00
6951.73Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc. including welding grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts, etc. of the required size on the top of the floor of the side of waiste slab with suitable arrangement as per approval of engineer in charge (for payment purpose, only the weight of the stainless steel members shall be considered excluding fixing accessories such as nut bolts, fasteners etc.). 50mm dia. pipe, 1.5mm thickness and weight 1.92Kilogram/ r. metreKg4,455.00721.763,215,440.80
FLOORING WORK
7033.06Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.Sqm394.001,296.88510,970.72
7133.23Providing and fixing black kadappa stone as shelves 25mm. Thick machine polished, extending the polish upto 20cm width on lower side, rounding corners, laying in position jointing with bedding cement mortar 1:4 proportion curing etc etc.complete.Sqm236.001,269.84299,682.24
7233.13Providing and laying cement concrete flooring 50mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction filling joints, marking lines to give the appearance of tiles of 30cmx30cm or other size laid diagonally /square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. with Crushed sand VSI GradeSqm74.00604.2444,713.76
7333.18Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.Sqm49.001,634.8880,109.12
7433.26Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.Sqm1.001,329.121,329.12
7533.31Providing and laying in situ cement concrete M30 with tremix treatment for 200mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete.Sqm18.001,522.5627,406.08
7633.34Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.Sqm1,675.004,184.967,009,808.00
7733.35Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.Sqm168.004,338.88728,931.84
7833.36Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polishSqm2.004,179.768,359.52
7933.37Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete. One side polishSqm2.004,170.408,340.80
8033.40Providing and laying vitrified mirror/glossy finish tiles decorative type having size 590 mm to 605 mmx 590 mm to 605 mm of 8 to10 mm thickness and confirming to IS.15622-2006 (groupBla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.Sqm115.001,224.08140,769.20
8133.41Providing and laying vitrified mirror /glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to10 mm thickness and confirming to IS.15622-2006 (groupBla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. completeSqm1,192.001,302.081,552,079.36
8233.66Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.Sqm130.00764.4099,372.00
8333.67Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.Sqm417.001,248.00520,416.00
8433.68Providing and laying telephone black / Amba White / Cad bury brown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame / dado / window boxing etc.On C.M.1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete.Sqm6.004,561.4427,368.64
8548.04Providing and laying 18 mm thick ADONI BROWN LEATHER FINISH stone for flooring, machine cut in required size, approved shade, color and texture laid using white cement slurry over 20 mm (average) thick base of cement mortar 1:4 followed by laying, fixing and jointed with white cement slurry mixed with matching pigment, including rubbing and curing moulding and polishing to edge to give high gloss finish etc complete. The application rate for tile adhesives shall be as per manufacturer's recommendations. as per detail drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels and as directed by Engineer in charge. Complete. a) FlooringSqm338.004,773.601,613,476.80
8648.05Providing and laying 18 mm thick ADONI BROWN LEATHER FINISH stone for flooring, machine cut in required size, approved shade, color and texture laid using white cement slurry over 20 mm (average) thick base of cement mortar 1:4 followed by laying, fixing and jointed with white cement slurry mixed with matching pigment, including rubbing and curing moulding and polishing to edge to give high gloss finish etc complete. The application rate for tile adhesives shall be as per manufacturer's recommendations. as per detail drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels and as directed by Engineer in charge. Complete. a) SkirtingSqm298.005,869.761,749,188.48
8711.41AProviding and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
11.41A.1Double charge vitrified tile polished finish of size
11.41A.1.1Size of Tile 600 x 600 mmSqm2,073.001,246.642,584,284.72
88MR Providing and fixing of 10 mm thick Laminated wooden flooring Classification of Use 23/32 (Heavy Domestic/General Commercial) with a Surface Abrasion Resistance of class AC4 (average 4500 cycles), Impact Resistance of IC2 (EN13329), Resistance to Cigarette Burn with a rating of 5 (EN 438-2:15), Swelling after 24 hrs in water of 15% (EN13329), Modulus of Rupture of 53.3 newton/mm2, Internal Bond 1.78 newton/mm2, Surface Soundness of 1.3 newton/mm2 (EN 13329:2000) with a 0.2mm thick wear layer on top of a High Density Fiber substrate core (density > 850 Kg/M3) of plank size 1291 mm X 135 mm having Uni fit locking arrangement (lock strength > 1000 lbs/ft) with an underlayment made of natural colour foam , with accessories like End profile, Transition profile, reducer, etc. complete. The rate includes cost of all materials, accessories, labour, HOM, etc., complete at all levels. (The Shade, pattern etc., to be approved by Engineer in charge)Sqm12.004,082.0048,984.00
ROOFING WORK
8912.21Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
12.21.1In 75x75 mm deep chaseMetre208.00261.6954,431.52
9012.22Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.Each8.00255.782,046.24
9138.39Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins)Sqm68.002,125.76144,551.68
9238.40Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of 35x35x0.8mm spaced @1200, center-to- center along main T all complete at all heights as per the specifications, drawings and as perSqm102.002,126.80216,933.60
9338.48Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Sqm412.002,088.32860,387.84
9438.51Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Sqm499.001,839.76918,040.24
95DSR 12.52Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.52.2GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.Sqm101.001,774.14179,188.14
9653.47Providing and fixing interior wall to wall expansion joint cover model W90 for 50 mm gap size, this surface mounted aluminium cover is designed for interior application where low maintenance is desirable. This model is made using Aluminium alloy 6063 and temper T5/T6. This cover is installed using stailness steel clip in the rear which helps the movement to + 10 mm. Metre119.002,422.16288,237.04
9753.48Providing and fixing of external wall to wall cover model ASM 200X for 50 mm gap size,this surface-mounted metal wall cover is designed for exterior applications where low maintenance or tamper-resistant applications are desired. The free-floating aluminum center plate spans the joint and slides over the surface of the wall to allow required movement.EPDM vapor barrier to protect the joint with water. This profile is extruded aluminum with ASTM B 221, Alloy 6063-T5. This profile has been tested under Architectural Testing Agency ( an Intertek Company) for the movement performance. The minimum opening of the profile is 10mm ( -40mm) and the maximum openeing of the profile is 76mm (+26mm) which is more than ±50% movement.Metre96.002,796.56268,469.76
9853.49Providing and fixig of floor to floor expansion joint cover GFT 200 for 50 mm gap size. The cover which is designed for interior floor to floor application suitable for most floor finishes where frame depth and configuration is variable to suit selected finish. It is a gasketed floor to floor joint cover comprises of extruded aluminium frames made of aluminium alloy 6063 temper T5/ T6 and TPR seal having strength of 90 shore A as per ASTM D2000 and available in 4 colours, with standard loading capacity of 500 lbs. The nominal joint width of the profile is 51 mm which contracts down to 38 mm as minimum and can expand 64 mm as maximum, the movement has been tested with Architectural testing INC., an Intertek company (Intertek – ATI) as per ASTM E 1399-97 Report no. 84287.01-106-31Mtrs.32.003,106.4899,407.36
9953.50Providing and Fixing of external Roof cover model RJT 200 for 50 mm gap size, Aluminium roof cover comprised of extruded alumunium components, Injection molded turnbar, duroflex gaskets and EPDM vapor barrier.This profile is extruded aluminum with ASTM B 221, Alloy 6063-T5. This profile has been tested under Architectural Testing Agency ( an Intertek Company) for the movement performance. The minimum opening of the profile is 3mm ( -47mm) and the maximum openeing of the profile is 92mm (+42mm) which is more than ±50% movement. Mtrs.34.006,491.68220,717.12
FINISHING WORK
10032.02Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Sqm2,285.00217.36496,667.60
10132.04Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Sqm898.00289.12259,629.76
10232.12Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete.Sqm3,464.00585.522,028,241.28
10332.26Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.rmt147.0059.288,714.16
10432.31Providing and applying gypsum plaster (with Gypsum material) with finishing with gypsum material in 10 to13 millimeter thickness to previously plastered surface / or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc.complete.Sqm9,323.00795.607,417,378.80
10532.34Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.Sqm15,970.0093.601,494,792.00
10632.37Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete.Rmt80.0041.603,328.00
10735.07Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.Sqm7.0099.84698.88
10835.13Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.Sqm11.0082.16903.76
10935.15Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.Sqm11.00108.161,189.76
11035.19Providing and applying priming coat over new wood and wood based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting, scaffolding etc. complete.Sqm4.0035.36141.44
11135.20Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. complete.Sqm171.0038.486,580.08
11235.21Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Sqm1,386.0037.4451,891.84
11335.24Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete.Sqm15.00169.522,542.80
11435.26Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessarySqm3,468.00306.801,063,982.40
11536.03Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete.Sqm29.0012.48361.92
11636.05Providing and applying colour-wash of approved colour and shade in two coats to new surface including scaffolding, brushing and brooming down (excluding base coat of white- wash) etc. complete.Sqm29.0019.76573.04
11736.11Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coat including scaffolding, preparing the surfaces. (excluding the primer coat.)etc. complete.Sqm1,386.0049.9269,189.12
11836.14Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete.Sqm12.00140.401,684.80
11948.13Providing and applying 2 Coats of high quality acrylic copolymer matt approved low VOC emulsion paint of approved shadethat gives smooth, flat and washable and durable finishing of approved make. Paint should have good flow levelling property with good colour retention and incan antibacterial property. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC acrylic copolymer based primer sealer that has incan antibacterial property. The work activity should cover all aspects of applying paints from surface preparation, filling to erecting and dismantling of scaffolding, finishing the surface etc as directed by Engineer in charge.Sqm46.00147.686,793.28
12048.14Providing and applying 2 Coats of 100% Pure acrylic low VOC water based paint with to withstand for period of atleast 5 years of approved make. Paint should provide durable long lasting silk finish with high resistance to UV and resistance to spreading of flame. Paint should protect against concrete carbonation with R value of minimum 600 and ability to built cracks upto min 0.7mm. The paint has to be applied on High quality water based acrylic copolymer primer with good alkali resistance properties. With all leads and lifts at all levels etc. complete, as directed by Engineer in charge.Sqm11,054.00185.122,046,316.48
121NSIProviding and fixing Glass Reinforced Concrete (G.R.C) ornamental Screens casted with 'Spray Mix' concrete design in approved size, pattern, thickness (Border 40-50mm thick & Internal Member 25-30mm thick) and shade. The Screens should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or 'Birla white', White Quartz fine graded seived Silica Sand, Alkali Resistant Glass Fiber , Super Plasticizers , Polymers and U.V resistant Synthetic inorganic pigments should be used for pigmentation . The Screens casting shall take place with layering methodology using- Direct Power Spray machines.The GRC Screens flexural strength average L.O.P should be above or equivalent to 6 N/mm2 & M.O.R should be above or equivalent to 12 N/mm2 for tests done on 28 days cured samples. The fixing of Screens should be done using ‘Dry fixing’ method onto structural support members i.e. R.C.C, Brick work or Red oxide Primer -paint or Epoxy primer -paint treated mild steel. The fixtures, fasteners and self tapping screws to be used for dry fixing should be of HP/KLIMAS. The quantity of fasteners or self tapping screws shall be calculated in accordance to the weight of Screens and actual site fixing conditions. If there will be requirement of Joint filling then Elastomeric exterior grade paintable PU Sealent will be used. For final finishing of Screen one weather sheild exterior grade water based diluted paint coat will be done if required. Vendor shall submit shop drawings of same, the drawings to be duly approved from Engineer in charge at site.Sqm73.006,523.92476,246.16
ALUMINIUM WORK
12121.18Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).Sqm6.004,567.4427,404.64
12239.50Providing and fixing in position aluminium openable window of any size as per detailed drawing and as directed by Engineer in charge with all necessary aluminum sections including necessary fixtures and fastening with 5mm thick clear float glass etc. complete. a)With colour anodizing Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered.Sqm5.005,928.0029,640.00
12339.51Providing and fixing in position aluminium openable window of any size as per detailed drawing and as directed by Engineer incharge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick clear float glass etc. complete.
bb) Powder CoatedSqm367.005,845.842,145,423.28
12439.52Providing and fixing inposition aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineer incharge with all necessary alluminium sections including necessary fixtures and fastening such as 5mm thick clear float glass etc. complete. Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered.
bb) Powder CoatedSqm118.005,944.64701,467.52
12539.55Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineer incharge with all necessary alluminium sections including necessary fixtures and fastening with 5mm thick float glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered.Sqm18.006,533.28117,599.04
12639.63Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.completeSqm63.009,038.64569,434.32
12739.64Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.CompleteSqm2.008,478.0816,956.16
WATER PROOFING
12831.05Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.Sqm203.00447.2090,781.60
12931.04Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.Sqm1,105.001,201.201,327,326.00
13052.14Waterproofing treatment to new terrace by using chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge, followed by average 112mm thick brick bat coba covered with 40mm thick IPS. The procedure includes filling of cracks on the RCC slab with high performance polyurethane (liquid applied) membrane. Clean the entire surface thoroughly and over this prepared surface, apply a primer coat of high performance polyurethane (liquid applied) membrane as approved by Engineer in charge. Apply the primer by roller. Extend the coating to parapet walls including the top of parapet. Allow the primer coat to set for 24 hrs. After the primer coat is set, apply two coats of chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge on surface. Ensure that pinholes are touched up properly. While the second coat of high performance polyurethane (liquid applied) membrane is wet and tacky, sprinkle coarse sand over the surface to make it rough and provide mechanical key for further treatment. Provide and lay average 15 mm thk protective coat of CM in 1:4 over the surface and allow to set and cure. Provide and lay 112 mm thk BB coba in average thickness in cement mortar 1:5 with one pouch of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents - which is based on special cements, aldehyde based polymers, shrinkage compensating agents and selected sands having high abrasion resistance as approved by Engineer in charge per 50 Kg bag of cement and finishing with 40 mm thick IPS layer in M-20 CC by mixing one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents per 50 Kg bag of cement, including all leads, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or
champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatment with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. The liquid membrane should have a track record of atleast 4 years in India & Gulf region and have atleast an 4 year track record in PWD. Single Component, Liquid Applied, chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane should have following minimum properties: 1) Water Permeability (DIN 1048): Nil as per DIN 1048 @ 7 bar of Hydrostatic Pressure. 2) Moisture Permeability: < 0.4 g/m2/day 3) Accelerated Weathering (IS 101): 2000 hrs No cracking or blister formation 4) Adhesion to concrete (ASTM D 1000): >21 Kg/cm2 (Concrete Fails) 5) Tensile Strength: > 2.0 MPa (ASTM D412) 6) Should not be water soluble or water dilutable 7) Shore A Hardness: 40 ± 5 (ASTM D2240) 8) Elongation at Break: > 900 % (ASTM D412) 9) Solids: > 95 % 10) No micro-bubble formation or blistering should take place during the curing of thick films. Sqm34.003,147.04106,999.36
Waterproofing of Raft
131NSISupplying and installing 1.5 mm composite thick fully bonded weldable HDPE membrane conforming to IS 16471:2017 requirements of UG waterproofing structures, requirements to provide Type A fully bonded protection of UG waterproofing structures. The membrane shall exhibit 25 years of service life tested and complied in accordance with EN 13251:2016 durability certification. The membrane should be minimum 2.4 m wide comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weatherproof protective layer with lap Joint Strength at overlaps >15000 N/m ASTM D 6392:2012. The membrane shall have minimum of 100 mm side and end laps which shall be thermofused with leister machines at all the joints for assuring watertightness and achieving monolithic membrane. End laps and side laps should be a minimum of 100 mm with double weld system, comprising of two parallel welds of 15 mm wide each with a 20 mm air channel gap in between the two weld lines.The size of the membrane should not be less than 2.4 Mtr. x 20 Mtr. to minimize the joints. This membrane shall be continued over the vertical surface but terminated minimum 100mm below the top edge of the raft slab/footings and fixed as per recommendation. The HDPE membrane should have the below mentioned techncial properties- 1) Lap Joint(side and end lap) Strength at overlaps 15000 N/m ASTM D 1876 2) Resist hydrostatic pressure of 70 m head of water as per ASTM D5385 3) Puncture Resistance of 1000 N as per ASTM E154 4) Peel Adhesion to concrete of 1500 N/m as per ASTM D 903 5) Tensile strength (Bare HDPE membrane) of 25 N/mm2 as per ASTM D412 6) Elongation (Bare HDPE Membrane) of 500% as per ASTM D 412 7) Low temperature Flexibility -25deg C - Pass as per ASTM D 1970 8) UV Resistance: 45 days Sqm30.001,473.2044,196.00
Waterproofing of Retaining Wall
132NSIProviding & applying 2 components, solvent free, liquid applied elastomeric seamless hybrid Polyurea Polyurethane Membrane, using high pressure plural component spray equipment, to form a minimum system thickness of 1.5 mm in two or more passes with a total consumption of 1.5-1.6 kg / m2. The membrane shall have 100% Solids, VOC Free, Tensile strength > 15 Mpa as per ASTM D 412, Elongation > 450% as per ASTM D 412, Low temperature Crack bridging ability of 3.2mm as per ASTM C 1305, Shore A Hardness > 85 ASTM D 2240, Puncture Resistance > 1000 N as per ASTM E 154, Water Head Resistance > 7 Bar as per ASTM D 5385.The coating should pass Dynamic Crack Bridging as per EN 1062-7, Method B for 20,000 cycles at -20 degree temperature. The membrane shall exhibit 25 years of service life tested and complied in accordance with EN 13251:2016 durability certification. Apply primer coat of epoxy primer by roller/ airless spray guideline and coverage @ 5-6 m2/ltr depends on porosity of concrete. Allow to cure for max 5-6 hours. Broadcast anti slip grains of 200-300 micron (dried sand) on wet primer at coverage of 0.8-1 kg/m2 and allow to come to touch dry condition before application of Membrane. Termination of Membrane at 300mm above G.L.-The waterproofing membrane shall be terminated on the vertical surface. The membrane shall be terminated either by creating a "U" shaped groove of approx. 10 mm x 10 mm size within the RCC retaining wall, tucking the membrane within the groove, followed by sealing the groove with polyurethane sealant/ epoxy mortar . Providing and fixing HDPE protection having dimple height of 6 to 8 mm, as a protection board, over the waterproofing membrane for vertical surface stuck to the membrane by spot bonding method, using synthetic adhesive with butt joints etc. complete. Note-Necessary back filling to be done by the main civil contractor within 2-3 days time progressively after installation of the membrane and protection board , taking care not to cause damage to the waterproofing treatment .Sqm40.002,735.93109,437.20
Construction Joint Treatment
133NSIWater Swellable Bar:-All Starter & Construction Joints of raft slab, retaining walls : Providing and applying water swellable bar at starter & all construction joints, of c/s size of minimum 20mm X 10mm, volumetric expansion of 300%, Shore A Hardness of 40± 5, hydrostatic head resistance of 60 m. It shall be fixed to the concrete using a hybrid adhesive or corrsion free nailing as recommended by manufacturer. Rmt61.00872.3353,212.13
134DSR 22.22Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of selfhealing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage. KG61.00332.7520,297.75
NEW TECHNOLOGIES AND MATERIALS
13551.189Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 18 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with a continuous aluminium I Beam holding the base of the standing seam along the length of the panel & fixed with purlin with self-drilling hex head screws offering best stability with a pull-out load of min. 21000N (21KN) tested as per ISO 6892:1998 and IS 1608: 2005., as per design requirement.
Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.9 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineer in charge. Colour: As per approval. The 18mm thick panels shall be used for a roofing height of upto 25 mtrsSqm122.005,661.76690,734.72
13653.01Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -8mm dia 160mm depthEach3.00252.72758.16
13753.04Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -16 mm dia 320mm depthEach3.00822.642,467.92
13853.05Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -20 mm dia400mm depth Each3.001,226.163,678.48
13922.18Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for double rim bored pile of 450 mm dia. each of load capacity as per design and of specified diameter of pile and bulb as directed, sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by concrete prepared in reversible drum type concrete mixer by tremie arrangement, compaction of concrete including chipping and dressing etc. complete. concrete prepared in reversible drum type concrete mixer by tremie arrangement, compaction of concrete including chipping and dressing etc. complete. (Excluding steel reinforcement)Metre578.003,073.201,776,309.60
14022.44Carrying out load test for 1.5 times the proposed safe working load on the pile in driven position above 400 mm and upto to 550 mm diameter including construction of test cap, use of accessories and instruments including providing graphs as per I.S. code or Std.Specifications and dismantling the test cap after testing and cleaning the site complete.Number1.00133,106.48133,106.48
141NSIProviding and laying toughening on float glass complete as directed by EICSqm731.00263.12192,340.72
142DSR 26.86Providing and fixing factory made single extruded WPC (Wood Polymer Composite ) solid door/window/ ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade ), calcium carbonate abd natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elastticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-in charge .
26.86.6Frame size 65x 125 mmmetre303.001,184.85359,009.55
143DSRFloat glass panes
9.7.7.25.0 mm thick glass panes (weight not less than 12.50 kg/sqm).Sqm303.002,230.12675,726.36
14451.60Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter Sqm89.002,860.00254,540.00
14551.61Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutterSqm59.003,224.00190,216.00
14639.81Providing and fixing 30mm thick SOLID PANEL PVC INTERNAL DOOR SHUTTER consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40 mm x 20 mm for stiles, top, lock and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S.frame shall be covered with 5mm thick heat molded PVC channel of size 30 x 100mm forming stiles, and 5mm thick, 125mm wide PVC sheets for toprail, lock rail and bottom rail on either side, and 15mm (5mm x3 ) thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 10mm thick prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent cement adhesive. including stainless steel fixtures and fastening Complete as per direction of Engineer incharge, manufacturer's specification and drawing.Sqm45.006,558.24295,120.80
SITE DEVELOPMENT WORKS
ROAD WORK
121.02Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical MeansCum495.00215.28106,563.60
221.36Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.Cum495.00124.8061,776.00
32.11Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. Cum220.00123.7627,227.20
42.23Watering and compacting of embankment formed of materials obtained from the road cutting within a lead of 50 m, not less than 97 % of standard Proctor density after laying them in layers of 20 cm. to 30 cm. with vibratory roller.Cum227.0094.6421,483.28
52.37Laying and spreading available soil in the sub-grade on a prepared surface, pulverizing, mixing the spread soil in place with rotavator with 3 per cent slaked lime having minimum content of 70 per cent of CaO, grading with motor grader and compacting with the road roller at OMC to the desired density to form a layer of improved sub grade.Cum330.00557.44183,955.20
63.01Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I MaterialCum165.002,120.56349,892.40
75.13Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Cum110.003,805.36418,589.60
85.22Providing and laying in situ cement concrete M -30 with tremix treatment for 200 mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen ( excluding reinforcement) with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) etc. complete with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Cum127.008,783.841,115,547.68
926.33Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.MT3.0093,291.12279,873.36
1014.33Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete.Sqm4.001,129.444,517.76
1153.60 Providing and fixing Mandatory/Regulatory sign boards in circular shape of ______ mm dia made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. c. 900 mm dia made out of 4mm aluminum composite material with 0.5 mm skin thickness on either sideNos1.0010,563.2810,563.28
1253.68Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of ____mm made out of ___mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 900 mm made out of 4mm aluminum composite material with 0.5 mm skin thickness on either sideNos1.007,297.687,297.68
1353.78Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of 4 mm aluminum composite panel with 0.5 mm skin thickness on either side bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt ~ 3.9 mtlong firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer including the Digitally Printed areas with approved printing technology with sheeting manufacturer approved inks and laminated with UV overlay film and this warranty certificate along with sheeting manufacturer attested 3 years outdoor weathering test report from Indian govt lab must be submitted to the Engineer in charge by the contractor/supplier.Sqm1.0014,754.4814,754.48
146.12aProviding and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per  direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and  Performance for IRC 35:2015). Sqm14.00692.649,696.96
157.01Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing PlantRmt135.00576.1677,781.60
1633.54Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand)Sqm445.001,457.04648,382.80
1751.85Providing and laying in place 300mm x 300mm x 16mm cement tactile directional and warning tiles (for a person with visual impairment)of the approved brand and make and specified colour for outdoor floors such as footpath, courtyard, multimodals location etc. laid on 20mm thick base of cement mortar 1:4 (1 cement: 4 coarse sand) in all shapes and patterns including grouting the joints with white cement with matching pigments etc. complete as per direction of engineer in chargeSqm23.001,612.0037,076.00
18Dsr 16.49Making bell mouth opening/ entrance of size 100x50x50 cm for drainage pipe under footpath, including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for shape of bell mouth, including plastering providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar 1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, shuttering & neat cement punning inside the bell mouth etc. all complete.Each7.002,615.9918,311.93
1942.09Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.Rmt45.00773.7634,819.20
20Dsr 19.36Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
19.36.2600 mm dia RCC pipes.Metre45.003,374.40151,848.00
HORTICULTURE AND LAND SCAPING
121.02Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical MeansCum956.00215.28205,807.68
221.36Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.Cum956.00124.80119,308.80
32.2Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).Cum637.00536.22341,572.14
421.37Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.Cum637.00622.96396,825.52
52.3Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment).Cum40.00305.7612,230.40
62.4Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) :
2.4.1Screened through sieve of I.S. designation 20 mmCum40.00264.3210,572.80
72.7Fine dressing of the ground.Sqm40.003.85154.00
82.8Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).Cum144.0054.447,839.36
92.9Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-chargeCum144.0038.015,473.44
102.10Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and earth shall be paid for separately).
2.10.1In rows 5 cm apart in both directionsSqm40.0018.41736.40
112.28Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of Each layer, dressing etc., lead upto 50 Metre and lift upto 1.5 m complete as per direction of Officer-in-charge.Cum15.00474.607,119.00
Trees/Plants
105.20Providing and Displaying Ficus black vivion piller topiary (sylinder type) well developed with fresh & healthy 180 to 210 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.Each2.002,132.004,264.00
118.54Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge.Each1.0041.6041.60
125.32Providing and Displaying Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge.Each1.00469.04469.04
135.21Providing and Displaying Ficus Long Island topiary well developed with fresh & healthy 5 to 6 ball specific size and shape 120 to 150 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.Each1.001,279.201,279.20
145.23Providing and Displaying Ficus nuda topiary well developed with fresh & healthy foliage 45 to 60cm spread 75 to 90 cm ht. bushy in 35 cm Cement Pot as per direction of the officer-in-charge.Each1.00351.78351.78
155.25Providing and Displaying Ficus reginold well developed fresh & healthy foliage 60 to 75 cm spread 105 to 120 cm ht., Bushy in 35 cm Cement Pot as per direction of the officer-in-charge.Each2.00392.29784.58
165.17Providing and Displaying Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 to 75 cm ht in 30 cm Earthen Pot as per direction of the officer-in-charge.Each3.00447.721,343.16
175.16Providing and Displaying Cyprus Golden 30 to 45 cm ht. well developed good Golden colour foliage, Conial Shape in 25 cm Earthen Pots as per direction of the officer-in-charge.Each3.00394.421,183.26
187.14Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.Each1.0067.6067.60
198.40Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.Each2.0057.20114.40
208.60Providing and stacking of Calliandra hybrida of height 75-90 cm. with 4-5branches in bag of size 25 cm as per direction of the officer-in-charge.Each3.0083.20249.60
215.11Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.Each1.002,014.742,014.74
225.13Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge.Each1.002,025.402,025.40
225.7Providing and Displaying Bamboo Buddha valley with fresh & healthy 3 to 4 suckers having 75 to 90 cm ht. in 25 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge.Each2.00479.70959.40
235.24Providing and Displaying Ficus Retusa topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 180 to 210cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.Each1.002,238.602,238.60
245.33Providing and Displaying Golden Bottle brush Topiary well developed with fresh & healthy foliage 5 to 6 big ball 115 to 180 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.Each1.001,012.701,012.70
252.57Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)
i2.57.1Tree PlantEach7.007.5953.13
ii2.57.2Shrubs PlantEach11.003.8041.80
262.35Supplying & Stacking of Selection No.1/doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.Sqm40.0052.832,113.20
BOUNADRY WALL
EARTH WORK
121.02Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical MeansCum289.00215.2862,215.92
221.36Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.Cum211.00124.8026,332.80
CONCRETE WORK
314.34Providing and laying in situ / ready mix 1:4:8 cement concrete of trap /granite /quartzite /gneiss metal for haunch filling including compacting, curing, mixing etc. complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) with fine agreegates of required specifications ( VSI sand finely washed etc )Cum16.005,482.8887,726.08
R.C.C WORK
426.33Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.MT6.0093,291.12559,746.72
525.13Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum58.007,578.48439,551.84
625.33Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum23.0014,525.68334,090.64
725.52Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum29.0012,950.08375,552.32
830.11Providing and fixing bituminous pad 25mm thick for expansion joints in retaining wall, compound wall etc. complete.Sqm6.001,837.6811,026.08
BRICK WORK
927.13Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Completecum141.007,390.241,042,023.84
1010.25Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
10.25.2In gratings, frames, guard bar, ladder, railings, brackets,gates and similar worksKG958.00148.02141,803.16
1113.52Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.
13.52.1On steel workSqm125.00207.3225,915.00
1216.18Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.
16.18.1With G.I. barbed wiremetre1,274.0018.9524,142.30
1316.19Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.KG221.00107.8423,832.64
FINISHING WORK
1332.04Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Sqm677.00289.12195,734.24
1432.12Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete.Sqm677.00585.52396,397.04
1532.12Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete.Sqm677.00585.52396,397.04
1535.26Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessarySqm1,353.00306.80415,100.40
INTERNAL AND EXTERNAL PLUMBING WORKS
[A]SANITARY INSTALLATIONS & C.P FITTINGS
142.33Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete.each16.007,388.00118,208.00
242.34Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. completeeach24.0011,200.00268,800.00
342.88Providing and fixing wall hung white wash basin of size 550 x 400 x 195 mm with pillar cock having flow rate up to 6.0 Litr/Minute,C.P.Angular stop cock long thread of Jaquar/Cera/Hindware /Perryware or equivalent make, including SS bottal trap of approved make etc complete as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
448.32Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mmthick stone black kadappa framework including chromium plated coupling bottle -Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m )each33.006,055.00199,815.00
5DSR 17.28Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
17.28.1Semi rigid pipe
17.28.1.132 mm dia each4.0085.68342.72
17.28.1.240 mm dia each11.0096.231,058.53
642.20Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete each34.00861.0029,274.00
7DSR 17.10Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required.
DSR 17.10.1.1Kitchen sink with drain board Size 510x1040 mm bowl depth 250mmeach5.005,727.3928,636.95
842.78Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.each5.0019,900.0099,500.00
948.43Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.each9.0018,575.00167,175.00
10DSR 8.10Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.
8.10.2Granite Stone of approved shadeSqm.9.003,341.1830,070.62
CP Brass fittings
11DSR 18.21Providing and fixing unplasticised PVC connection pipe with brass unions
18.21.245 cm length
18.21.2.115 mm nominal bore each128.0080.6110,318.08
12DSR 17.16AProviding and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge.each43.00287.9112,380.13
1348.27Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.each43.002,399.00103,157.00
1442.82Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. completeeach11.001,625.0017,875.00
1542.79Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.each128.002,687.00343,936.00
16M.R.Central Hole Basin Mixer with Popup Waste System with 450mm LongBraided Hoses (CQT-23169B jaguar) Nos.35.003,832.19134,126.65
17M.R.Sink Mixer with Swinging Spout (Table Mounted Model) with 450mm Long Braided Hoses (CQT-23309B jaguar)Nos.16.003,948.3263,173.12
1842.81Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete.each12.004,738.0056,856.00
1941.51Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete.each12.00528.006,336.00
20DSR 18.52Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:
18.52.1 15mm nominal boreeach12.00552.866,634.32
21DSR 17.34.1Providing and fixing toilet paper holder : C.P. brasseach22.00662.7414,580.28
22DSR 17.71Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.each21.00138.812,915.01
23DSR 17.73Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
17.73.1450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gmseach22.00555.2912,216.38
[B]C.I. SOIL WASTE & VENT PIPES AND FITTINGS
Providing & fixing soil, waste and vent pipes.
2443.43Providing and fixing ISI 1729/2002 grade 100 mm dia Cast Iron Soil Pipes With lugs including plug bend necessary fittings such as bends, tees, single junction, double junction, slotted vent, offsets on wall or into the ground including filling joints with cement mortar 1:2 proportion fixing on wall by means of galvanised Mild Steel bracket of 30 x 5 mm plate and 8 mm square rod with Galvanised Iron clamp with washer as per design, drawing and as directed to keep pipe 50 mm away from wall including necessary scaffolding and painting the exposed faces with one coat of red lead oil paint and two coats of white oil paint including removing the existing pipe if necessary and conveying and stacking in PWD Chowky or as directed by Engineer-in-Charge.Rm.213.002,059.00438,567.00
2543.42Providing and fixing ISI 1729/2002 grade 75 mm dia Cast Iron Waste Water Pipe with lugs necessary fittings such as bends, tees, single junction, double junction, slotted vent, offsets on wall or into the ground including filling joints with cement mortar 1:2 proportion fixing on wall by means by galvanised Mild Steel bracket of 30 x 5 mm plate and 8 mm square rod with Galvanised Iron clamp with washer as per design drawing and as directed to keep pipe 50 mm away from wall including necessary scaffolding and painting the exposed faces with one coat of red lead oil paint and two coats of gray oil paint including removing the existing pipe if necessary and conveying and stacking in PWD Chowky or as directed by Engineer-in-Charge.Rm.169.001,736.00293,384.00
26MRProviding and fixing 150 mm dia Hubless cast iron pipes including fittings Rm.5.002,042.9710,214.85
27DSR 18.76.1Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) brickseach26.00343.708,936.20
28DSR 18.77Cutting holes up to 15x15 cm in R.C.C. floors androofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proofeach26.00372.729,690.72
29DSR 17.60Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
17.60.1.1a) 100mm inlet & 100mm outlet.Each3.001,646.334,938.99
17.60.2.1a) 100mm inlet & 75mm outlet.Each34.001,628.7255,376.48
30MRProviding and fixing 150 Dia CI. 90° elbow with including fittings complete. Nos.1.00837.52837.52
31MRProviding and fixing 150 Dia CI. 45° elbow with including fittings complete. Nos.2.00597.351,194.70
32MRProviding and fixing 150 Dia CI. Y Band with including fittings complete. Nos.1.001,878.271,878.27
33MRProviding and fixing 150X150X100 Y Band with including fittings complete. Nos.1.001,465.661,465.66
34MRProviding and fixing END CAP with including fittings complete. Nos.1.00387.97387.97
[C]INTERNAL RAIN WATER DRAINAGE WORK
35DSR 19.2 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)
19.2.1 110 mm dia metre5.00795.543,977.70
19.2.2 160 mm dia metre34.00972.9133,078.94
3642.87Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.Metre64.00569.0036,416.00
3742.85Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.mtr85.001,481.00125,885.00
3812.22Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. Each13.00219.842,857.92
[D]INTERNAL WATER SUPPLY WORKS
39Providing and fixing on walls/ ceiling/ floor CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
42.5620mm dia nominal outer dia pipesRm.64.00310.0019,840.00
42.5725mm dia nominal outer dia pipes Rm.85.00375.0031,875.00
42.5832mm dia nominal outer dia pipes Rm.77.00431.0033,187.00
40Providing and fixing on walls/ ceiling/ floors, heavy grade having embossed as ISI Mark galvanised iron pipes weight of with necessary fittings. remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Internal work-Exposed on wall
41.1120mm dia nominal boreMetre34.00493.0016,762.00
41.1225mm dia nominal boreMetre81.00639.0051,759.00
41.1332mm dia nominal boreMetre64.00696.0044,544.00
41.1440mm dia nominal boreMetre43.00769.0033,067.00
41.1550mm dia nominal boreMetre34.00984.0033,456.00
DSR 18.12.765mm dia nominal boreMetre30.00739.3422,180.20
41.1680mm dia nominal boreMetre102.001,579.00161,058.00
41DSR 18.17Providing and fixing gun metal gate valve with wheel of approved quality.
18.17.1A20mm dia nominal boreEach4.00445.251,781.00
18.17.125mm dia nominal boreEach7.00513.233,592.61
18.17.232mm dia nominal boreEach6.00568.653,411.90
18.17.340mm dia nominal boreEach6.00681.214,087.26
18.17.450mm dia nominal boreEach4.00846.583,386.32
18.17.565mm dia nominal boreEach4.001,436.595,746.36
18.17.680mm dia nominal boreEach2.002,147.734,295.46
4242.53Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters
Capcity in Per Litersper litre849.0014.0011,886.00
[E]RO Plant & Drinking Fountain
43M.R.RO Plant 500 LPH (Liter per hour)
PLANT CAPACITY - 500 LPH RECOVERY - 50% ELECTRICAL CONNECTION - 415 V, 3 PHASE, 50 HZ TDS - < 100 PPM
1000L STORAGE TANK AND DRINKING FOUNTAIN Nos.1.00449,728.20449,728.20
44M.R.Supply installation, testing and commissioning of water cooler 40/80 having stainless steel body & tank with storage 80Ltrs. & colling capacity 40 Ltrs. Per hour Nos.7.0029,325.00205,275.00
[F]Solar Water Heaters
45M.R.Solar Water Heaters (500 lpd)
Supply, Installation, Testing & Commissioning of 500 LPD Flat Plate collector based on thermosyphon circulation Solar water heating System suitable for 2.0 Kg/cm2 working pressure & 3 Kg/cm2 testing pressure comprising of 8 numbers of Flat Plate collectors, internal system piping, insulated hot water storage tank with heat exchanger, valves on inlet & outlet, temperature gauge, MS Angle frame etc. complete in all respect. Details of each items used in one 500 LPD system are mentioned below: (1.1 to 1.10) Make - Greentek/Bosch/Honeywell/BHEL
Solar Flat Plate collector having collector area should be min. 2 Sq, Mtr. Its include the collector stands & other acessories to joint the collectors each other. (Collectror should be BIS approved.) - 4 Nos.
Solar hot water storage tank capacity of 500 litre made up of SS-304L insulated with 100 mm rock wool insulation covered with chicken mesh and 22 SWG aluminum cladding. Tank should be installed on MS stand of proper height & its load baring. 1 Nos.
Heat exchanger cage/Coil type SS304 having surface area should not less then 1.2 Sq.mtr. With SS make up tank. 1 Nos.
Circulation pump to circulate hot water from collectors to heatexchanger in (1W+1S) manner
Inter-connected G.I. B class system piping with GI fittings, insulated with 50 mm glasswool/rockwool insulation covered with chicken mesh & 26SWG aluminum cladding to connect the collectors with hot water storage tank. 1 Lot.
Ball Valve for Inlet & outlet. - 2 Nos.
Ball Valve for makeup tank - 1 Nos.
NRV for Inlet - 1 Nos.
NRV for makeup tank. - 1 Nos.
Dial Type Temprature gauge - 1 Nos.Nos.5.00198,720.00993,600.00
[G]INTERNAL SEWERAGE SYSTEM
4642.03Providing and laying 100 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) completemetre119.00349.0041,531.00
4742.07 Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.metre64.00530.0033,920.00
4842.02Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.each9.001,600.0014,400.00
49DSR 19.7Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
5019.7.1Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
19.7.1.1(i) For Sewer Lineeach4.0010,530.6842,122.72
51Extra for depth for manholes:
DSR 19.8.1.1Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5metre1.007,277.487,277.48
52DSR 19.15Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design
19.15.1With 20x20 mm square bareach43.00449.1619,313.88
[H]EXTERNAL SEWERAGE & EFFULENT SYSTEM
5342.08 Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.metre64.00561.0035,904.00
5442.09 Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.metre64.00744.0047,616.00
55DSR Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.
19.6.5450 mm. dia. RCC Pipesmetre13.001,336.6517,376.45
56DSR Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
1.50 m depth
2.10.1.2Pipes 80 mm to 300 mm diametermetre64.00290.3918,584.96
2.10.1.3Pipes 300 mm to 600 mm diametermetre64.00453.3329,013.12
1.50 m to 3.00 m depth
2.14.1.1Pipes 80 mm to 300 mm diametermetre43.00601.8025,877.40
2.14.1.2Pipes 300 mm to 600 mm diametermetre43.00715.3030,757.90
57Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)
2.20.1Depth not exceeding 1.5 meterSqm17.0059.411,009.97
2.20.2+ 2.20.1Depth 1.5 to 3.00 meterSqm51.0067.293,431.79
58DSR 19.7Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
19.7.1Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
With common burnt clay FPS (non modular) bricks of class designation 75
19.7.1.1(i) For Sewer Lineeach13.0010,530.68136,898.84
5919.8.1.1Extra for depth for manholes:
Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5metre2.007,277.4814,554.96
60DSR 19.7.2Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).
With common burnt clay FPS (non modular) bricks of class designation 75
19.7.2.1(i) For Sewer Lineeach6.0021,774.14130,644.84
6119.8.2.1Extra for depth for manholes:
DSR Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5metre2.009,281.4618,562.92
62DSR 19.11Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:
19.11.11.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):
19.11.1.1With common burnt clay F.P.S. (non modular) bricks of class designation 7.5each4.0020,370.0481,480.16
63DSR 19.12Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29m
19.12.1With common burnt clay F.P.S. (non modular) bricks of class designation 7.5metre1.008,131.818,131.81
64DSR 19.13Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
19.13.12.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :
19.13.1.1With common burnt clay F.P.S. (non modular) bricks of class designation 7.5each2.0043,678.6587,357.30
65DSR 19.14Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m :
19.14.1With common burnt clay F.P.S. (non modular) bricks of class designation 7.5metre1.0018,777.8118,777.81
66DSR 19.16Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. each85.00456.5838,809.30
[I]EXTERNAL RAIN WATER DRAINAGE SYSTEM
6742.07 Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.metre64.00530.0033,920.00
42.08 Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.metre64.00561.0035,904.00
68DSR 19.7Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
6919.7.1Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
With common burnt clay FPS (non modular) bricks of class designation 75
19.7.1.1(i) For Sewer Lineeach13.0010,530.68136,898.84
7019.8.1.1Extra for depth for manholes:
DSR Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5metre5.007,277.4836,387.40
7119.16 Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. each9.00456.584,109.22
[J]EXTERNALWATER SUPPLY SYSTEM
72Providing and laying double flanged (Screwed/Welded) centrifugally (Spun) Ductile iron pipes of class K-9 conforming to IS 8329
18.73.1100mm dia Ductile iron double flangedRM170.001,502.06255,350.20
18.73.2150mm dia Ductile iron double flangedRM9.002,150.1619,351.44
73Supply CI specials such as Bends, reducers, collars etc. including cartage, loading, unloading, taxes, excise etc. complete. (10 % of item No. 1)
74DSRExcavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,
in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.
2.10.1.2a) Pipes 80mm to 300mm diameter.RM170.00290.3949,366.30
75DSRProviding push-on-joints to centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket :
18.70.1100mm dia pipesNo.9.0098.50886.50
18.70.2150mm dia pipesNo.9.00159.031,431.27
76DSRProviding and fixing C.I. Sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately):
18.31.1.2100mm diameter Each1.004,111.364,111.36
18.31.3.2150mm diameter Each1.006,029.856,029.85
77Providing and fixing on walls/ ceiling/ floors, heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings. remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
41.1120mm dia nominal boreMetre5.00493.002,465.00
41.1225mm dia nominal boreMetre5.00639.003,195.00
41.1332mm dia nominal boreMetre5.00696.003,480.00
41.1440mm dia nominal boreMetre5.00769.003,845.00
41.1550mm dia nominal boreMetre5.00984.004,920.00
DSR 18.12.765mm dia nominal boreMetre5.00739.343,696.70
41.1680mm dia nominal boreMetre43.001,579.0067,897.00
78DSR Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.
18.17.125mm nominal bore.Nos.1.00513.23513.23
18.17.232mm nominal bore.Nos.1.00568.65568.65
18.17.340mm nominal bore.Nos.1.00681.21681.21
18.17.450mm nominal bore.Nos.2.00846.581,693.16
18.17.565mm nominal bore.Nos.1.001,436.591,436.59
18.17.680mm nominal bore.Nos.2.002,147.734,295.46
79DSR Provding and fixing C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately.
18.59.1 50mm dia Each1.004,740.504,740.50
18.59.2 80mm dia Each1.005,766.975,766.97
18.59.3100mm dia Each1.007,333.227,333.22
MR150mm dia Each1.009,606.879,606.87
80DSR Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
18.34.1With common burnt clay F.P.S. (non modular) bricks of class designation 7.5Each1.0015,582.3415,582.34
81DSR 18.33.1Constructing brick masonry chamber 600 x 600 x 750 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design Each1.008,957.208,957.20
82Domestic pump Hydro-Pneumatic Booster System Parallel Pumping System Numbers of Pump in System: 3 Pump Version: Cast Iron & S.S AISI 304 Seal Material: Carbon/SiC/SS316/EPDM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Mounting: IEC Enclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE1 Motor System Components Accessories: Included Header Flange Rating: PN 16 Pump Controller: Single VFD with HMI & PLC HPN Pressure Tank: 200 litre
Flow Rate- 420 lpm
2 Working + 1 Stand By
Head 75 mEach1.00342,646.24342,646.24
[K]EXTERNAL DRAIN CHANNEL SYSTEM
83Constructing RCC precast perforated RCC. slab covered Drain with 150mm thick RCC 1.1.5.3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size) wall including earth excavation, 75mm thick bed concrete 1:4:8 (1 cement : 4 fine sand : 8 graded stone aggregate 40mm nominal size) and 100mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:
ARDrain 300 wide average. Depth 500cm with R.C.C. Slabmetre17.004,878.5682,935.52
ARDrain 450 wide average. Depth 750cm with R.C.C. Slabmetre9.006,768.5660,917.04
ARDrain 600 wide average. Depth 1200 cm with R.C.C. Slabmetre9.008,414.9075,734.10
[L]BORE WELL
84DSR 23.1Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
23.1.1 All types of soil
23.1.1.3400 mm diametre77.00817.0262,910.54
85DSR Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
23.2.1All types of soil
23.2.1.3400 mm diametre51.001,021.2752,084.77
86DSR 23.3Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
23.3.3200 mm diametre77.00918.0870,692.16
8748.59Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (RMS) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
150mm nominal size diametre51.00494.0025,194.00
88MRProviding and fixing in 200X150 UPVC Pipe Reducer including fittings complete. each1.00800.57800.57
89DSR 23.13Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
23.13.3200mm nominal size diaeach1.00264.82264.82
90DSR Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
23.14.3200mm nominal size diaeach1.001,891.361,891.36
91DSR 23.15Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
23.15.2150mm nominal size diaeach1.00265.52265.52
8848.54`Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.cum17.001,494.0025,398.00
89DSR 23.10Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
23.10.3200 mm nominal size dia having minimum wall thickness 5.00 mm.metre77.002,014.31155,101.87
23.10.2150 mm nominal size dia having minimum wall thickness 5.00 mm.metre51.001,626.3382,942.83
90DSR 23.11Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.
23.11.3200 mm nominal size diametre77.002,120.10163,247.70
91DSR 23.12Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hour11.00894.749,842.14
92DSR 18.12.8Providing and fixing 80 dia G.I. column pipes complete with G.I. fittings including trenching and refilling etc.metre85.00858.9973,014.15
93DSR Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :
18.59.280 mm diaeach1.005,766.975,766.97
94DSR Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately)
18.60.180 mm diaeach1.002,166.782,166.78
95DSR Providing and fixing gun metal gate valve with C.I.wheel of approved quality (screwed end) :
18.17.680 mm diaeach1.002,147.732,147.73
96DSR Providing and fixing gun metal non- return valve of approved quality (screwed end) :
18.19.6.280 mm diaeach1.003,179.193,179.19
97NSIa) Contractor shall include the rate of electrical control panels complete with all accessories &controls, all Electrical/Mechanical items as required to operate the system automatic/manual.
b) Contractor to select suitable HP of pumps .
c) Level Controller with sufficient nos. of low / high level alarms, contacts with electrodes and control wiring for the automatic operation of water supply pumps, Submersible Sump Pumps, to achieve the functional requirement shall be provided. Control wiring between these pumps and water tanks shall be provided.Domestic water pumps must start at low water level in under ground domestic water tank & stop at high level in that water tank. Dry running protection shall be provided for all the pumps.Sequencing shall be provided for each set of pumps.
Supplying & Installation of ( 700 lpm and 125 mtr head ) submersible starter and cable (L&T or BCH make) etc of approved make, and all accessories complete as per requirement of site.1.00
IRAIN WATER HARVESTING
RECHARGE PITS
(A)21.02Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical MeansCum39.00207.008,073.00
(B)21.02+21.04Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.Cum39.00465.0018,135.00
(C)21.02+21.04In all kind of soil upto 3.0m to 4.5m. depthCum39.00723.0028,197.00
(D)21.02+21.04In all kind of soil upto 4.5 m to 6.0m. depthCum18.00981.0017,658.00
224.08Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum2.006,359.0012,718.00
327.01Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. CompleteCum41.007,755.00317,955.00
425.72Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum3.0014,116.0042,348.00
526.33Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required completeTONNE1.0089,703.0089,703.00
632.04Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. completeSqm79.00278.0021,962.00
7DSR 19.15Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
19.15.1With 20x20mm square barNos.17.00449.167,635.72
8DSR Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
19.19.2.2M.D. -10- Circular shape 500mm internal diameterNo.2.00966.931,933.86
48.48Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.MTR43.00416.0017,888.00
1148.49Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge
150 mm nominal size diaMTR26.00494.0012,844.00
1248.51Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.cum21.001,309.0027,489.00
1348.52Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.cum23.001,457.0033,511.00
1448.53Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.cum23.001,457.0033,511.00
1548.54Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.Cum2.001,494.002,988.00
DESILTING CHAMBER
21.02Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical MeansCum17.00207.003,519.00
1721.02+21.04Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.Cum7.00465.003,255.00
1825.11Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Cum2.007,104.0014,208.00
1927.01Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. CompleteCum6.007,755.0046,530.00
2012.59Providing and laying in situ / ready mix controlled grade of M25 of trap /granite /quartzite /gneiss metal for RCC works in cut off walls / curtain walls including necessary scaffolding, centering, compacting by vibrator, finishing and curing etc. complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) with fine agreegates of required specifications ( VSI sand finely washed etc ), excluding reinforcement)Cum3.008,019.0024,057.00
2126.33Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required completeTONNE1.0089,703.0089,703.00
2232.04Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. completeSqm30.00278.008,340.00
23DSR 19.15Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
19.15.1With 20x20mm square barNos.21.00449.169,432.36
24Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
19.19.2.2M.D. -10- Circular shape 500mm internal diameterNo.4.00926.483,705.92
FIRE FIGHTING WORKS
[A]SUBHEAD-I FIRE HYDRANT SYSTEM
Supplying, installation, testing and commissioning of booster fire pump [BP]suitable for water discharge of 900 LPM at 35 m head driven by electricmotor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kWcapacity for manual/automatic operation and consisting of following :
(a) Horizontal/ vertical type, single/multi stage, centrifugal casing pump of castiron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.
(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.
(d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set
113.3.2with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BPSet1.0069,720.0069,720.00
213-8-14Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PGEach3.00772.002,316.00
313-8-13Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARVNo.3.00840.002,520.00
413-8-12Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACTSet3.0012,472.0037,416.00
513-6-6Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PPMtr34.001,588.0053,992.00
613-7-20Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFVSet3.004,121.0012,363.00
713-7-24Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRVSet3.008,240.0024,720.00
8DSR 18.13Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.Each3.001,158.263,474.78
INTERNAL HYDRANT
913-7-34Supplying and erecting gun metal hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Single headed GunmetalSet3.007,646.0022,938.00
1013-8-4Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRLrequired :
Gun MetalSet6.005,229.0031,374.00
1113-8-2Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HVSet3.006,921.0020,763.00
1213-8-7Supplying & erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZNos.3.001,926.005,778.00
13NCSRFireman Axe-made of carbon steel with rubber insulated handle tested to 20,000 Volts as per IS:926 Make: NEWAGENos.3.001,177.733,533.19
14NCSRFire shaft door fabricated out of M.S. sheet and frame, door size of 1200 (W) x 2100 (h) with 4 mm thick glass, suitable Rubber beading and Locking arrangement and complete door shall be powder coated with red color powder coating Nos.3.0012,894.6038,683.80
15DSR 18.19Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
18.19.12 way-100 mm dia M.S. PipeSet3.005,911.4417,734.32
[B]SUBHEAD-II : FIRE EXTINGUSHER
Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below:
1613-15-1Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall completeNos.4.009,902.0039,608.00
17NCSRSupplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wallNos.4.003,706.5514,826.20
[C] SUBHEAD-III : FIRE CONTROL PANELS
1812-4-27Supplying & erecting automatic control panel for 3 Ph, 415 volt, /centrifugal pump set up to 10 - 15 HP consisting of Star Delta starter having relay range 13- 22 Amp, S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.Set1.0012,005.0012,005.00
197-1-28Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr9.00181.001,629.00
20Supplying, erecting & terminating XLPE armoured cable G.I. earth wire complete erected with glands& lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
7-2-143 C x 2.5 SqmmMtr9.00173.001,557.00
7-2-152 C x 2.5 SqmmMtr9.00242.002,178.00
21Supplying & erecting rigid steel conduit 16 SWG with necessary accessories in wall/floor with chisellingappropriately as per specification No: WG-MA/CC.
1-1-325 mm ConduitMtr9.00240.002,160.00
1-1-532 mm ConduitMtr9.00332.002,988.00
227-11-6Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware..Mtr9.00614.005,526.00
INTERNAL AND EXTERNAL ELECTRICAL WORKS
SUBHEAD-1 : INTERNAL WIRING
11-7-5Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CWPoint510.00745.68380,296.80
21-7-6Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/ CWPoint170.00835.12141,970.40
31-7-6Point wiring for exhaust fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/ CWPoint17.00835.1214,197.04
41-7-22Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CWPoint52.00212.1611,032.32
51-7-8Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No WG-PW/SWPoint478.00812.24388,250.72
61-7-26Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CWPoint48.00401.4419,269.12
71-3-2Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWM2,760.0064.48177,964.80
81-3-2Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWM1,274.0032.2441,073.76
91-3-3Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW M6,368.0092.56589,422.08
101-3-3Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWM4,096.0046.28189,562.88
111-3-4Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWM265.00137.2836,379.20
121-3-4Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWM128.0068.648,785.92
131-3-3Supplying & erecting mains with 4x4 sq.mm. and earth wire 2.5 sq.mm FRLSH PVC copper wire, in HMS PVC conduit min. 25mm dia, as per specification No: WGMA/PC.M1,045.00217.36227,141.20
141-3-4Supplying & erecting mains with 4x6 sq.mm. and earth wire 4 sq.mm FRLSH PVC copper wire, in HMS PVC conduit min. 25mm dia, as per specification No: WG-MA/PC.M55.00320.8417,646.20
151-3-5Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BWM170.00482.5682,035.20
161-3-5Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BWM299.00120.6436,071.36
171-3-10.Supplying and erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BWM383.00720.72276,035.76
181-3-10.Supplying and erecting mains with 2x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BWM383.00360.36138,017.88
191-6-23Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.Each119.00397.2847,276.32
201-6-24Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box.Each128.0021.842,795.52
211-6-35Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.Each255.00229.8458,609.20
221-6-43Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.Each2.00356.72713.44
231-6-57Supplying and erecting ISI mark modular type USB Charger socket of 1 Module with nominal output voltage of 5 VDC + 5/- 5% and nominal output current of 5 V - 750 mA , duly erected on provided plate and box with wiring connections complete.Each4.00642.722,570.88
241-6-36Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.Each43.00260.0011,180.00
251-6-2Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.Each170.00110.2418,740.80
261-6-11Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.Each170.00166.4028,288.00
271-6-38Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.Each170.00348.4059,228.00
281-6-1Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.Each1,019.0074.8876,302.72
291-6-10Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections completeEach43.00116.485,008.64
305-4-12Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 30 A, 3 pin plug & earth socket and 30A, 3 pin plug top with 30A triple pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame.Each2.001,888.643,777.28
315-4-11Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame.Each9.00856.967,712.64
SUBHEAD-2 : FANS & LIGHT FIXTURES
322-1-7Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warrantyEach26.002,624.9668,248.96
332-1-8Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.Each1.003,040.963,040.96
342-1-2Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.Each76.00679.1251,613.12
352-1-4Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.Each76.001,261.5295,875.52
362-1-17Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.Each340.00643.76218,878.40
372_1_20Supplying and erecting CRCA powder coated corridor / passage light LED fitting (4 feet) Max. 50W with high transitivity diffuser with system lumens output of Min. 6000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.Each2.001,878.243,756.48
382-1-16Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.Each6.00450.322,701.92
392-1-13Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20WEach1.0081.1281.12
402-1-14Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface.Each35.00139.364,877.60
412-8-11Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22/E-27 base.Each4.00239.20956.80
422-1-15Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.Each11.001,472.6416,199.04
43NCSRSupply, installation, connecting, testing and commissioning of LED Patint bed light with a nominal system lumen output of 1553 lumens and a minimum system efficacy of 153 lm/W. The luminaire shall have a rated system lifetime of 50000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80, beam angl of LED 120 degree. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 28 W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. Make: Philips /Bajaj/ or Eq. of GE, Trilux, Lighting TechnologyEach1.0027,071.2027,071.20
442-1-5Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120- 270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.Each3.001,594.324,782.96
452-6-1Supplying and erecting integrated LED Highbay Fitting 70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2.Each2.0011,336.0022,672.00
462-5-2Supplying and erecting Gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12W LED lamp on provided pipe as per specification No. FG-ODF/GLTNos.3.001,190.803,572.40
472-9-1Supplying & erecting aviation obstruction light consisting of yellow painted die-cast aluminium alloy housing with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete.Each1.005,018.005,018.00
482-10-22Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CFEach128.003,963.44507,320.32
492-11-5Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.Each128.00183.0423,429.12
502-11-6Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.Each128.00238.1630,484.48
512-10-5Providing and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one metre of 3core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation.Each1.005,656.565,656.56
522-10-13Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.Each7.001,645.2811,516.96
532-10-19Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 900 RPM complete erected in position as per specification no. FG- FN/EXFEach11.005,214.5657,360.16
542-3-13Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.Each1.00145.60145.60
553-11-74Supply, installation, testing and commissioning air curtain of 3 feet width having air throw velocity of 12 to 14m/sec, low noise level up to 38 to 46dBA suitable for door height upto 9 feet, working on 1 phase, 230V, 50Hz, A.C. supply.Each1.0019,393.9219,393.92
563-11-75Supply, installation, testing and commissioning air curtain of 4 feet width having air throw velocity of 12 to 14m/sec, low noise level up to 38 to 46dBA suitable for door height upto 9 feet, working on 1 phase, 230V, 50Hz, A.C. supply.Each1.0020,319.5220,319.52
573-11-76Supply, installation, testing and commissioning air curtain of 6 feet width having air throw velocity of 12 to 14m/sec, low noise level up to 38 to 46dBA suitable for door height upto 9 feet, working on 1 phase, 230V, 50Hz, A.C. supply.Each1.0023,615.2823,615.28
SUBHEAD-3 : T.V. / TELEPHONE / LAN SYSTEM
581-2-3Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. withPVC accessories on wall / ceiling as per specification No: WG- MA/CON.Metre213.0085.2818,164.64
591-2-4Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. withPVC accessories on wall /ceiling as per specification No: WG- MA/CON.Metre340.0099.8433,945.60
601-6-14Supplying and erecting ISI mark modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.Each2.0098.80197.60
611-6-15Supplying and erecting ISI marked modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.Each3.0099.84299.52
621-6-17Supplying and erecting ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete.Each22.00135.202,974.40
631-8-1Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TWMetre43.0023.921,028.56
641-8-19Supplying & installing co-axial copper cable low voltage grade RG-6 as per specification No. WG-TWMetre95.0048.884,643.60
651-10-2Supplying & installing UTP networking cat-6 LSZH cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NCMetre1,019.0068.6469,944.16
SUBHEAD-4 : DISTRIBUTION BOARDS
665-4-8Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDBEach1.001,293.761,293.76
675-4-9Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDBEach1.001,554.801,554.80
685-4-1Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDBEach1.002,450.242,450.24
695-4-2Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDBEach6.003,515.2021,091.20
705-4-3Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDBEach11.004,793.3652,726.96
715-3-2Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCBEach680.00180.96123,052.80
725-3-6Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCBEach26.00556.4014,466.40
735-3-8Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCBEach2.00741.521,483.04
745-3-12Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCBEach51.001,101.3656,169.36
755-3-13Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCBEach22.001,382.1630,407.52
765-4-4Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDBEach1.004,836.004,836.00
775-4-5Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDBEach1.005,923.845,923.84
SUBHEAD-5 : EARTHING WORK
789-1-2Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EPEach2.006,745.4413,490.88
799-1-3Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EPEach4.006,297.2025,188.80
809-1-4Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia.G.l. Rod complete with all materials as per specification no. EA-EPEach1.001,560.001,560.00
819-1-5Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBIEach1.0014,357.2014,357.20
829-1-6Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no. ESE -LAEach2.0016,363.3632,726.72
839-2-2Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP.Kg.13.00918.3211,938.16
849-2-3Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP.Kg.13.00230.883,001.44
859-2-4Supplying and erecting Annealed bare copper wire of high purity of different sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws in an approved manner.Kg.17.00877.7614,921.92
869-2-5Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.Kg.85.00161.2013,702.00
SUBHEAD-6 : LIGHTNING PROTECTION SYSTEM
87NCSRSupply, Erection, Installation & Commissioning of External Lightning Wide Area Protection System based on pro-active Early Streamer Emission (ESE) Technology. No external power source required. Break down time not more than 245.5 Micro second. Wind Resistance up to 120miles/hours. Produces a leader of not less than 2x10E8 V/m/s in the lightning generated electromagnetic field with Level-I protection radius of 79 meters at 5 mtr. Mast including mast for supporting the device. Device confirming to NFC17-102 & UNE 21186 standards & CPRI Tested.Set1.00103,981.28103,981.28
887-2-4Supplying, erecting & terminating DOWN CONDUTOR XLPE insulated unarmoured cable 1100 V. 1core 70 sq. mm. copper conductor complete erected with provided lugs, laid inprovided control panel/distribution boards / pipe as per specification no. CBLT/CURM34.00937.0431,859.36
89NCSRSupply, Erection, Installation & Commissioning of Lightning Event Counter (Model: LEC-IV) for counting the number of lightning strikes without any power supply. The Counter should be mounted on the Down Conductor and the triggering impulse should be > = 1.5 KA for 8/20µs. The Lightning Event Counter should be robust, non-resettable mechanical counter with IP65 rated enclosure suitable for external application.Set1.0035,434.8835,434.88
909-3-1Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.Each1.006,322.166,322.16
91NCSRJointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.each6.00145.60873.60
929-2-3Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.Kg.255.00230.8858,874.40
SUBHEAD-7 : RISING MAIN
936-8-2Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 800A Capacity at 40oC ambient temperature Sandwich type Aluminium Conductor tin plated at joints /Aluminium conductor Silver flashed copper bimetal contact having purity not less than 99.6% with suitable for (3L+ N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54/55 Protection, 42/50KA short circuit rating for 1sec, Insulation Class F (155 C) , casing made of minimum 1.5mm hot dipped / electro Galvanized /Epoxy powder coated steel sheet enclosure having Mechanical strength certification up to IK10 with required shade of paint having overall cross sectional area not more than 0.0170 sq. Mtr., complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories with Horizontal / Vertical G.I. Support at required interval with External Double run 50x5mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specificationMeter1.0014,966.6414,966.64
946-8-1Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 630A Capacity at 40oC ambient temperature Sandwich type Aluminium Conductor tin plated at joints /Aluminium conductor Silver flashed copper bimetal contact having purity not less than 99.6% with suitable for (3L+ N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54/55 Protection,36/40KA short circuit rating for 1sec, Insulation Class F (155 C) , casing made of minimum 1.5mm hot dipped / electro Galvanized /Epoxy powder coated steel sheet enclosure having Mechanical strength certification up to IK10 with required shade of paint having overall cross sectional area not more than 0.0170 sq. Mtr., complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories with Horizontal / Vertical G.I. Support at required interval with External Double run 50x5mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specificationMeter1.0013,598.0013,598.00
95DSRSupplying, installation by suspension on ceiling, testing and commissioning of following capacity sandwich type Rising Mains for use on 3 phase 4 wire 415 Volts, 50 Hz AC supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6 mm thick steel sheet duly powder coated in convenient sections complete with 4 nos aluminium bus bars having current density of 130 A/sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends , fire barrier at each floor, provision of tapping at every meter, adopter box and copper flexible joints, continuous earthing with 2 nos aluminium strip of suitable size( one on each side) including. G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc as required
DSR 3.13.1400A (S.C. rating for 1 sec -25 kA)Meter1.0014,002.8414,002.84
96NCSRSupplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for Aluminium 400A 3 phase 4 wire 415V, 50 Hz A.C ,36/40kA short circuit rating for 1 sec Sandwich type Aluminium BBT. with necessary accessories completeEach1.00198,078.40198,078.40
976-8-10Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for 1600A 3 phase 4 wire 415V, 50 Hz A.C ,65/80kA short circuit rating for 1 sec Sandwich type Aluminium BBT.with necessary accessories complete confirming to IEC 61439-6 as per specificationEach1.0041,236.0041,236.00
986-8-9Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for 1250A 3 phase 4 wire 415V, 50 Hz A.C ,65kA short circuit rating for 1 sec Sandwich type Aluminium BBT. with necessary accessories complete confirming to IEC 61439-6 as per specificationEach1.0037,683.3637,683.36
996-8-8Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for 1000A 3 phase 4 wire 415V, 50 Hz A.C ,50kA short circuit rating for 1 sec Sandwich type Aluminium BBT. with necessary accessories complete confirming to IEC 61439-6 as per specificationEach1.0036,588.2436,588.24
1006-8-7Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for 800A 3 phase 4 wire 415V, 50 Hz A.C ,42/50kA short circuit rating for 1 sec Sandwich type Aluminium BBT with necessary accessories complete confirming to IEC 61439-6 as per specificationEach1.0034,046.4834,046.48
1016-8-6Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for Aluminium 630A 3 phase 4 wire 415V, 50 Hz A.C ,36/40kA short circuit rating for 1 sec Sandwich type Aluminium BBT. with necessary accessories completeEach1.0030,128.8030,128.80
1026-8-11Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 32A to 125A 3 phase 4 wire 415V, 50Hz AC Supply made with High Grade Plastic enclosure with provision of MCB/ MCCB without (MCB/MCCB) complete as required confirming to IEC 61439-6 as per specificationEach1.0010,182.6410,182.64
1036-8-12Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 125A to 200A 3 phase 4 wire 415V, 50Hz AC Supply made with 1.5 mm thick sheet metal enclosure (IP54/55) duly powder coated with provision of MCCB( without MCCB) complete as required confirming to IEC 61439-6 as per specificationEach1.0012,855.4412,855.44
1046-8-13Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 250A to 400A 3 phase 4 wire 415V, 50Hz AC Supply made with 1.5mm thick sheet metal enclosure (IP54/55) duly powder coated with provision of MCCB( without MCCB) complete as required confirming to IEC 61439-6 as per specificationEach1.0019,000.8019,000.80
1055-5-1Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCBEach1.005,521.365,521.36
1065-5-2Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCBEach1.0011,028.1611,028.16
1075-5-3Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCBEach1.0014,725.3614,725.36
1085-5-4Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCBEach1.0019,305.5219,305.52
SUBHEAD-8 : CABLE TRAY
1097-11-11Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.M1.00383.76383.76
1107-11-12Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.M1.00473.20473.20
1117-11-13Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.M1.00651.04651.04
1127-11-14Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 400 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.M17.0016,577.60281,819.20
1137-11-15Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware.M1.001,007.761,007.76
SUBHEAD-9 : L.T. CABLES
1147-1-15Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.68.0020,134.401,369,139.20
1157-1-16Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.1.00304.72304.72
1167-1-17Supplying, erecting & terminating XLPE armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.26.0011,887.20309,067.20
1177-1-18Supplying, erecting & terminating XLPE armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.1.00513.76513.76
1187-1-19Supplying, erecting & terminating XLPE armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.26.0018,907.20491,587.20
1197-1-20Supplying, erecting & terminating XLPE armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.1.00784.16784.16
1207-1-21Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.26.0027,861.60724,401.60
1217-1-22Supplying, erecting & terminating XLPE armoured cable 1100 V. 3½ core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB- LT/ALMtr.340.001,136.72386,484.80
1227-1-23Supplying, erecting & terminating XLPE armoured cable 3½core 240 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.1.001,423.761,423.76
1237-1-24Supplying, erecting & terminating XLPE armoured cable 3½ core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.1.001,701.441,701.44
1247-1-25Supplying, erecting & terminating XLPE armoured cable 3½ core 400 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.1.002,122.642,122.64
1257-1-28Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.68.0015,059.201,024,025.60
1267-1-29Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALMtr.68.0017,555.201,193,753.60
SUBHEAD-10 : L.T. DISTRIBUSTION PANELS
127NCSRSupply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB ( 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.
NCSRMain LT Panel (Boys Hostel)
specification as above
INCOMER:-
1 Nos. 500 Amps. 4P MCCB (25 KA)
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-500 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
500 Amps. TP&N aluminium bus bars (36 KA)
OUT GOINGS:-
63 A FP MCB (10 KA) - 20 Nos.
100 A FP MCCB (10 KA) - 2 Nos.
315 A FP MCCB (25 KA) - 2 Nos.
315 A FP Automatic Changeover PanelNos.1.00364,000.00364,000.00
NCSRLight and Emergency Panel (Boys Hostel)
specification as above
INCOMER:-
1 Nos. 315 Amps. 4P MCCB (25 KA)
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-315 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
400 Amps. TP&N aluminium bus bars (36 KA)
OUT GOINGS:-
40 A FP MCB (10 KA) - 20 Nos.
63 A FP MCB (10 KA) - 4 Nos.Nos.1.00171,600.00171,600.00
SUBHEAD-11 : MISCELLANEOUS
12810-6-27Supplying and fixing PVC synthetic elastomer electrically insulating mat with class C insulation conforming to IS: 15652 – 2006 tested having 3mm thickness up to 33 Kv (for HT)Metre1.008,224.328,224.32
12910-6-26Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 -2006 having 2.5 mm thickness up to 11 kV (for LT)Metre1.006,108.966,108.96
130NCSRSupplying and fixing of fire bucket, round bottom made of GI sheet 9 to 11 liters capacity duly painted as per fire brigade design, supported on hanging bracket chained and locaked, initially filled with fine river sand, water as per direction of Engineer Incharge.Each1.00499.20499.20
131NCSRSupplying and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T & P for proper completion of work.Each1.00665.60665.60
13213-15-1Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.Each1.0010,298.0810,298.08
13310-6-24Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)Each1.00923.52923.52
134NCSRProviding and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.Each1.00249.60249.60
1357-6-14Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.Metre13.007,737.60100,588.80
a)7-6-16Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.Metre13.0011,434.80148,652.40
13610-6-23Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.Each1.00708.24708.24
137NCSRProviding and fixing UPVC pipes as per IS:4985 suitable for 6 Kg/ sq cm pressure, including all fittings with accessories i.e bends, junctions, cowls, offsets, PVC pipe clips/holders etc. and jointing with rubber rings and cement solvent complete as per manufacturer's specifications with excavation, refilling and disposal of surplus earth, including cutting holes in walls and floors ,wherever required and making good the same, complete as directed by the Engineer-in-Charge.
a)110 mm outer diaMetre13.00328.644,272.32
b)200 mm outer diaMetre13.00965.1212,546.56
138NCSRRACEWAY
Supply, fixing & installing of MS floor trunking with cover of following size embeded in floor by cutting the existing floor to be in flush to the existing floor finish level and rendering the floor complete with cement concrete as approved layout complete as required for power/telepone / data in unit of 1 length of 2.5 meter each including al accessories to complete job similar to CTM Engg., Slotco, Profab, OBO or equivalent.
a.300 mm X 38 mm - 3 CompartmentsMeter1.007,025.207,025.20
b.150 mm X 38 mm - 1 CompatmentsMeter1.003,785.603,785.60
c.100 mm X 38 mm - 1 CompartmentsMeter1.002,818.402,818.40
SUBHEAD-12 : EXTERNAL LIGHTING
STREET LIGHT POLE WITH LED LAMP :
1398-2-16Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL.Each1.0022,558.6422,558.64
1408-2-13Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL.Each3.0053,333.28159,999.84
1412-7-5Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPCEach4.004,338.8817,355.52
1422-7-6Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPCEach1.001,510.081,510.08
1432-4-6Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2Each3.0018,548.4055,645.20
1442-4-7Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.Each1.007,592.007,592.00
1457-8-5Supplying & erecting water tight terminal box of cast iron of size 200 x 150 x 150 mm complete on pole as per specification no. CB-SBEach6.003,750.2422,501.44
1465-2-6Supplying & erecting three phase, 415V, street light control panel up to the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.Each1.0032,719.4432,719.44
POST TOP LIGHTING :
147NCSRSITC of 4M Decorative Pole with Single Arm made up of MS Grooved Section of Dia 114mm and 89mm with Base Plate of Dia 430mm Thickness 15mm. Cast Iron Parts shall be used in Pole Base and Single Arm Bracket. Embelishments shall be of Cast Iron. Pre treatment through shot blasting and polishing method. Top coat of UV rays resistant exterior grade PU Paint. RCC Foundation including cost of foundation, foundation bolts, excavation & back filling and required T&P complete in all aspect.Nos.2.0065,884.00131,768.00
1482-4-21Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 2 Year warranty as per specification No FGNos.3.0011,584.5634,753.68
HIGH MAST :
1498-2-4Supplying and erecting 20 m (clear height) motorized high-mast (Top- 150mm, Bottom-410 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3+3 mm thickness, with base plate 25 mm thick x OD 570 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 6 mm, SG-DG U clamps, double drum winch assembly 500 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete specification no. OH-PL/HM (excluding luminariesSet1.00344,748.56344,748.56
1502-4-18Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.Each2.0032,959.6865,919.36
1518-2-23Supplying and erecting outdoor stand mounted feeder pillar for high- mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation completeJob1.0030,895.2830,895.28
OUTDOOR LANDSCAPE LIGHTING :
FAÇADE LIGHTING -
152NCSRSupply of decorative 18 to 24 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect.Nos.1.0025,896.0025,896.00
153NCSRSITC of Recessed Mounted LED Step Light 5W warm white color made up of Aluminum. Fixture shall be suitable for outdoor location and shall be IP65 Protected.Nos.1.006,458.406,458.40
154MRSITC of LED Spike & Spot Light 8W warm white color made up of Aluminum, Beam Angle shall be 8 Degrees. Fixture shall be IP66 Protected with Meanwell Driver or Equivalent.Nos.1.009,516.009,516.00
155NCSRSITC of LED Spike Light 36W warm white color made up of Aluminum, Beam Angle shall be 25 Degrees. Fixture shall be IP66 Protected with Meanwell Driver or Equivalent.Nos.1.0026,624.0026,624.00
156NCSRSITC of LED Wall Washer Light 54W cool white color made up of Pressure Die Cast Aluminum, Beam Angle shall be 15 Degrees. Fixture shall be IP67 Protected with Meanwell Driver or Equivalent.Nos.1.0037,523.2037,523.20
157NCSRSITC of Base Mounted LED Spot Light of 50W, Warm White in Color, Optical Lens of 8 Degrees, IP 66 Protected, Surge Protection: Upto 4KVA, Fixture shall be made up of Pressure Die Cast Aluminum & complete with lamp & related accessories.Nos.1.0035,734.4035,734.40
SUBHEAD-13 : FIRE DETECTION SYSTEM
158DSR 17.1.2Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFyAFAS/SD .Nos.6.006,308.3937,850.34
15913-10-7Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from - 20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.Nos.1.002,813.202,813.20
160NCSRSupplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.Nos.1.0010,337.6010,337.60
161NCSRSupplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc. complete as required.Nos.1.0085,280.0085,280.00
162NCSRSupplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.Nos.1.00343.20343.20
MANUAL CALL POINT
16313-10-9Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.Nos.13.0055,770.00725,010.00
FAULT ISOLATOR
16413-10-12Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISMNos.1.003,173.043,173.04
MONITOR MODULES
16513-10-11Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MMNos.1.003,868.803,868.80
CONTROL MODULES
16613-10-10Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRMNos.1.003,926.003,926.00
167NCSRSupplying, installation, testing & commissioning of addressable phone control module complete as requiredNos.17.004,316.0073,372.00
HOOTER CUM STROBE
16813-10-13Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.Nos.17.00162,822.402,767,980.80
FIRE ALARM CONTROL PANEL
16913-10-4Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CPNos.1.00409,059.04409,059.04
1703-10-2Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.Nos.1.00178,869.60178,869.60
171NCSRSupply , Installation , Testing and Commissioning of Addressable Fire Fighter's Telephone Jack with suitable module for two way communication between Remote Fire Fighter & Fire Command Center.Nos.17.002,103.9235,766.64
172NCSRSupply , Installation , Testing and Commissioning of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center.Nos.9.007,592.0068,328.00
173NCSRSupplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as requiredNos.1.00248,924.00248,924.00
17413-10-14Supplying, installing, testing and commissioning of digital linear heat detection cable addressable through monitor module with temperature ratings such as 60°- 70°C, conforming to IS 2189: 2008, EN 54 or UL listed FF-AFAS/LHDC.RM85.0041,080.003,491,800.00
PA SYSTEM
SPEAKERS
175NCSRSupplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
a)Ceiling Mounted SpeakersNos.3.002,360.807,082.40
b)Wall Mounted SpeakersNos.1.002,360.802,360.80
PA CONTROLLER
176NCSRSupplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.Nos.1.00167,544.00167,544.00
DIGITAL AMPLIFIERS
177NCSRSupply, installing, testing and commissioning of 2X250W Class-D Amplifier with 2 independent channels and can provide automatic re- settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection.
500 WattsNos.1.00167,960.00167,960.00
PAGING STATION
178NCSRSupply, installing, testing and commissioning of IP based Networkable touch screen paging station for selection of zones, supervision of system status, setting of scheduled broadcasts with the following functions: . Built-in monitoring loudspeaker . Detachable goose-neck microphone . LCD touchscreen display . Audio inputNos.1.0082,742.4082,742.40
179NCSRSupplying and Laying of 2 core twin twisted 48/0.2 ATC, Multi strand, over all armoured speaker cable as specified in the Tender Specifications.RM170.0079.0413,436.80
SUBHEAD-14 : LOCAL AREA NETWORK  ( LAN )
SECTION-I : STRUCTURED CABLING SYSTEM PASSIVE
1801-10-9Supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125μm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete.Mtr102.0012,979.201,323,878.40
1811-12-5Supplying and fixing 12 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/ LIUNos.1.005,047.125,047.12
1821-12-7Supplying and fixing 24 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/ LIUNos.1.005,546.325,546.32
1831-10-26Supplying and installing 6 port single mode fibre adapter with plate complete.Nos.7.0036,799.36257,595.52
1841-10-27Supplying and installing single mode simplex pigtail with SC/LC splicing complete.Nos.7.006,489.6045,427.20
185MRSupply, Installation, Testing & Commissioning of Splicing Tray. Approved Makes: Derwiser/Nexans/Siemon/SystimaxNos.1.00459.68459.68
1861-10-29Supplying and fixing IP66 enclosure for fibre splicing complete.Nos.1.009,542.009,542.00
187MRSupply, Installation, Testing & Commissioning of Cat 6A, 23 AWG (0.57 • 0.03mm ) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C.2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tape or Metallic Shield inside. Connectivity of Hub room to End Point.Mtr255.00101.9225,989.60
188MRSupply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C.2 Category 6A, IEC 60603-7 (603-7), Universal 110 Impact Tool & Tooless (Both) Termination, Min. 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fi at user end.Nos.41.00551.2022,599.20
189MRSupply, Installation, Testing & Commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, clear label marks and earthing plug for CAT6A cable termination at rack end.Nos.1.0018,293.6018,293.60
190MRSupply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm, 3 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity.Nos.26.00613.6015,953.60
191MRSupply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm, 3 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.Nos.26.00686.4017,846.40
192MRSupply , Installation , Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side.Nos.26.00218.405,678.40
1931-12-29Supplying and fixing 42 U floor mount server rack (Dimension-DxWxH –800x1000x2070 mm) as per specification No. WG-NAS/RAKNos.1.0088,361.5288,361.52
1941-12-20Supplying and fixing 15U wall mount rack (Dimension-DxWxH – 500x600x767 mm) as per specification No. WG-NAS/RAKNos.1.0012,822.1612,822.16
SECTION-II : LOCAL AREA NETWORK (LAN)
195NCSRSupply , Installation , Testing and Commissioning of Core Switch with switching capacity of 3.2Tbps, forwarding performance of 2Bpps with 48 x 1/10G/25G SFP28 ports plus 4x 40/100G QSFP28 ports from day 1, dual hot swappable internal power supply, MAC address 200k, 100k IPv4, 100K IPv6 routes and 48K IPv6 multicast routes. Should support advance layer 3 (OSPF, BGP and MPLS) with 1 year support. Stack Module/40 Gig Optics and all other Cables should be included in Day 1. Approved make - Cisco / Juniper / Impulse / Nexxus/Arista/ AlcatelNos.1.002,013,544.002,013,544.00
196NCSRSupply , Installation , Testing and Commissioning of Access switch should have 48 x10/100/1000T port , Min 8 x1 G SFP port , should be upgradable to Min 4x 10 G based SFP+ port , 2x Stacking port comprising 40 Gbps of stacking bandwidth from day 1 , Min 2 x 10G Copper port support ,Support less than 50 Millisecond convergence based of RFC 3619/REP/G.8032 , Min Operating temp 0-50 Degree C ,Must have Common criteriacertification EAL3/NDcPP/NDPP, should support AVB,CE.2 and CB certified.Min 740 PoE/PoE+ buwer budget based on IEEE 802.3af/IEEE 802.3at, Min 1GB RAM & 8GB Flash, 64K MAC Address. Auto adustable fan based on temperture variation.Nos.1.00543,660.00543,660.00
197NCSRSupply , Installation , Testing and Commissioning of Core Switch with switching capacity of 3.2Tbps, forwarding performance of 2Bpps with 48 x 1/10G/25G SFP28 ports plus 4x 40/100G QSFP28 ports from day 1, dual hot swappable internal power supply, MAC address 200k, 100k IPv4, 100K IPv6 routes and 48K IPv6 multicast routes. Should support advance layer 3 (OSPF, BGP and MPLS) with 1 year support. Stack Module/40 Gig Optics and all other Cables should be included in Day 1. Approved make - Cisco / Juniper / Impulse / Nexxus/Arista/ AlcatelNos.1.00417,019.20417,019.20
1981-11-13Supplying, fixing, and configuring 48 ports managed gigabit switch Layer 2 with 48 10/100/1000 Base-T ports management switch with 4 10GE SFP+ ports erected in provided rack complete.Nos.1.00209,739.92209,739.92
1991-11-10Supplying, fixing, and configuring 24 ports + 4 (SFP+) port, Managed Layer 2, POE Switch of , 370W, 6KV surge protection on ethernet port and console port for management erected in provided rack complete.Nos.4.00694,187.522,776,750.08
2001-11-14Supplying, fixing, and configuring min. 580 watt redundant power supply system erected in provided rack complete.Nos.4.00372,819.201,491,276.80
201MRSupply , Installation , Testing and Commissioning of fiber Modules SM 1G BASENos.6.0023,795.20142,771.20
202MRSupply , Installation , Testing and Commissioning of fiber Modules SM 10G BASENos.1.0027,695.2027,695.20
203MRSupply, Installation, Testing & Commissioning of Appliance based customised ITAM for asset inventory management with ability to map physical locations and exact rack elevations for audit and support control. Appliance shall be Intel x86 based device with secure intranet server with Linux Based operating system and relational databases for long term storage. Appliance includes license for 100 units under control.Nos.1.001,229,280.001,229,280.00
SECTION-III : Wi-Fi SYSTEMS & WEB SECURITY
2041-12-36Supplying and fixing dual-band POE 3x3 Mesh Router, 802.11 n/ac, standalone/software based access point complete.Nos.3.00112,597.68337,793.04
2051-12-37Supplying, installing and activating physical license pack software for multiple access point with management, configuration and trouble shooting for all access point in network complete.Nos.1.00101,230.48101,230.48
SUBHEAD-15 : IP CCTV SYSTEM
206NCSRSupply , Installation , Testing and Commissioning of LC-LC singlemode fiber patch cord for LIU to switch connectivity.Nos.4.002,849.6011,398.40
2071-10-3Supplying and installing enhanced cat-6 cable with 4-connector channel, performance test report as per ANSI/TIA-568.2-D suitable for networking complete as per specification.Mtr.2,123.0068.64145,722.72
2081-12-2Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IONos.6.003,157.4418,944.64
2091-12-4Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PPNos.4.0044,162.56176,650.24
2101-10-17Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2- D in position as per specification No. WG-COC/PCNos.43.0013,208.00567,944.00
2111-10-20Supplying and fixing 3 m UTP patch cord of enhanced Cat 6 type with 4 connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PCNos.43.0023,036.00990,548.00
212NCSRSupply , Installation , Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side.Nos.43.00197.608,496.80
213NCSRSupply, installation, testing and commissioning of 5 MP (2592 x 1944) Dome camera , ONVIF profile S , G& T BIS,UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS ,2.7 mm to 13.5 mm motorized varifocal lens , Quad stream with each stream support H.265 compression simultaneously ,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : 1 / 5s ~ 1 / 100,000 s ,WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support upto 256GB, Cloud Storage , Alarm trigger - 1 input / 1 output , frame rate : Main stream should support 25 &30 fps@5MP, , ROI Min. 8 Region, Two Way Audio, Hardware reset, Edge analytics : Face Detection, Customer Flow staistics, Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection, Regional population statistics, SOD- Stationaary Object Detection, Tempering detection, Rare Sound Detection, Defog, Motion Detection, License plate detection. Protocol:- TCP/IP, HTTP, DHCP, DNS, DDNS, RTP, RTSP,SMTP, NTP, UPnP, SNMP, HTTPS,FTP PPPOE, NFS/SMB/CIFS, P2P , In built IR LED , IR Distance upto 45 meters , IP 66 ,IK10,POE/12V DC. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ AxisNos.26.0044,865.601,166,505.60
214NCSRSupply, installation, testing and commissioning of 5 MP (2592 x 1944) Bullet camera , ONVIF profile S , G& T BIS,UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS ,2.7 mm to 13.5 mm motorized varifocal lens , Quad stream with each stream support H.265 compression simultaneously ,min illumination : Color 0.01lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : 1 / 5s ~ 1 / 100,000 s ,WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support upto 256GB, Cloud Storage , Alarm trigger - 1 input / 1 output , frame rate : Main stream should support 25 &30 fps@5MP, Net HDD, ROI Min. 8 Region, Two Way Audio, Hardware reset, Edge analytics : Face Detection, Customer Flow staistics, Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection, Regional population statistics, SOD-Stationaary Object Detection, Tempering detection, Rare Sound Detection, Defog, Motion Detection, License plate detection. Protocol:- TCP/IP, HTTP, DHCP, DNS, DDNS, RTP, RTSP,SMTP, NTP, UPnP, SNMP, HTTPS,FTP PPPOE, NFS/SMB/CIFS, P2P , In built IR LED , IR Distance upto 45 meters , IP 67 ,IK10,POE/12V DC. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ AxisNos.9.0046,779.20421,012.80
215NCSRSupply, installation, testing and commissioning of 5 MP PTZ Camera , UL,CE,FCC Certified , ONVIF profile S,G & Q , Quad stream,4.3-141.9mm focal length , 33 X Optical Zoom , 12 X digital Zoom ,Frame rate : 20 fps ,Shutter Speed : 1/5 ~ 1/100,000s , Inbuilt IR , IR distance upto 200 mtr , 2D / 3D noise reduction ,120 dB WDR , 360 deg endess pan , tilt -10 to 90 deg , auto flip support ,255 presets ,Auto pan ,Edge analytics : Pedestrian Intrusion Detection, Line cross Detection, Heat Map,Cross Count,Stationaary Object Detection, Vehicle Detection, face Detection, , SD Card supportup to 128GB , white balance-Auto/manual/indoor ,Fixed Iris, Alarm : 1 IN , 1 Out , Audio - 1 IN/1 Out,RS485,ROI,1xBNC IP 66 weather proof , Power : 24V AC/ POE+ /DC12V. Approved Makes :Allgovision/ Impulse / Avigilon / Cisco/ AxisNos1.00453,492.00453,492.00
216NCSRSupply, installation, testing and commissioning of 64 channel NVR , ONVIF compliant , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA , Alarm in/out :16ch in / 4ch out , 2 X RJ-45 port (1000M) , Bit Rate 16kbps-20mbps per channel, Sync Playback 4/8/10/16 ch playback, iOS smartphone support , third party camera supported, 8 HDD support , each HDD slot support upto 8 TB HDD , , 1x3.0 USB for backup /upgrade , 2x 2.0 USB for mouse, Display resolution up to 4K, 1 E-Sata Port, RS-485 Port, Cloud Storage, Net HDD, Two Way Talk, Edge analytics : Customer Flow staistics, Face Attendence, Face Detection and Recognition, Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection, Queue length detection, Regional population statistics, SOD-Stationaary Object Detection, Deterrence, PIR, AI Registerd Qty- 10000 & AI Captured Qty- 200000. Protocol support:- HTTp, TCP/IP, IPv4, UPNP, RTSP,UDP,SMTP,NTP,DHCP,DNS,IP filter,PPPOE,DDNS,FTP,IP search, P2P, NFS/SMB/CIFS, IPC Management. Certifications: UL,CE,FCC,BIS. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ AxisNos.1.00616,096.00616,096.00
217NCSRSupply, installation, testing and commissioning of Network PTZ joystick Keyboard, support 5.0 "LCD HD real-time display, up port HDMI output to achieve the main console screen, Support ONVIF 2.4, back-end PTZ not restricted by manufacturer , wide compatibility,with PTZ tour, Pan Tilt, Add, delete preset, A-B scan, 360°, pattern and so on functions. USB Port. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ AxisEach1.00143,208.00143,208.00
218NCSRSupply , Installation, Testing and Commissioning of 8TB Surviellance Hard Disk.Nos.1.0045,344.0045,344.00
219NCSRSupply , Installation, Testing and Commissioning of Full HD 55" LED Professional Display Panel.Nos.1.00113,372.48113,372.48
2201-11-10Supplying, fixing, and configuring 24 ports + 4 (SFP+) port, Managed Layer 2, POE Switch of , 370W, 6KV surge protection on ethernet port and console port for management erected in provided rack complete.Nos.4.00694,187.522,776,750.08
221NCSRSupply , Installation , Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit or latest.Nos.5.00152,484.80762,424.00
222NCSRSupply , Installation, Testing and Commissioning of fiber Modules 1G BASE.Nos.5.0023,712.00118,560.00
SUBHEAD-16 : UPS SYSTEM
223NCSRSupply, installation, testing & commissioning of 5 KVA UPS System. Each UPS of 5 KVA should have following specifications in addition to tender requirements : True online double conversions, IGBT Rectifier & inverter based UPS. Three phases Input/ three phase output with SMF batteries complete with MS Fabricated battery rack to accommodate the all battery system, Suitable for 30 Min backup on Full load at 0.9 Load P.f., with Each UPS, Minimum VAH : 4800 VAH, Input voltage operations on mains without switch over to battery : 340-478V at 100% load, 220-478 V @ 50% load. Input power factor 0.99 @ 100% linear load, input THDi less than 3% @ 100% linear load. Output THD is less than 2% for full linear load & Less than 5 % for nonlinear load. Crest factor 3:1, over load 125% for 10 min, 150% for 1 min. Battery Flexible design shall be available from 36 to 40. Battery type should be Valve regulated lead-acid (VRLA). Inbuilt Delta - Star Input Isolation Transformer with each UPS Shall be provided as mandatory, parallel communication port, USB, EPO and SNMP interface, BMS interface, Dust Filter at Air Inlet point and parallel kit are required. UPS should be latest three level IGBT Converter technology providing a high efficiency of > = 95.4% from 25% to 100 % load levels (w/o transformer losses).Each1.00139,230.00139,230.00
LCD Display indicating all important parameters. To improve the UPS Security over LAN/WAN the SNMP card provided with UPS shall be having Cybersecurity enhancements for IEC / UL 2900- 2-2 certification, including stronger encryption, configurable password policy. The card shall work on GIGABIT Speed and should support all major protocols. UPS shall be provided with Temperature Humidity Sensors to monitor Temperature and Humidity over LAN through SNMP card Software. Battery open rack with top cover, battery interlinks, battery breaker(MCCB), Battery breaker enclosure, battery to UPS cable as required should be provided with UPS systems. UPS system shall be parallelable upto
4 units. Each UPS shall be compatible for working in parallel redundant mode with other and should be able to be used with Lithium Ion Batteries if required in future.
UPS Make: Schneider, Eaton, Gutor, GE, ABB, Powerware
Battery Make: Panasonic, Exide, Quanta, Amara Raja
SUBHEAD - 17 : LIFT WORK
NANDED
13 Pax. Lift
22417-1-5SITC of Electric Traction Passenger Lift withJob3.001,442,180.484,326,541.44
Rated capacity :- 13 Passenger/884Kg
Floors :- G+1 floor (2Stops/2 Landings)
Travel :- As per Arch. Drawings
Location of Lift Machine:- MR
Rated speed :- 1.0mps VS
Car/Landing door clear opening of 900/1000 mm wide x 2000 mm high
Clear Car size of ......mm wide x mm deep x 2250mm high
Lift shaft available having clear size of 1900 mm wide x 2500 mm deep, 1500 mm Pit depth, ………mm Overhead.
Doors type :- COPO/TOPO Doors with frame having clear opening of 900/1000 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/frames.
Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc.
COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.
Clear Car size of ......mm wide x ......mm deep x mm high LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.
Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.
ARD complete with necessary SMF VRLA batteries.
Fireman controller having fireman switch at fire Landing.
CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.
Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.
Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.
Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no.LFT.
Lift shaft available having clear size of ......mm wide x mm deep, ......mm Pit depth, mm Overhead.
Add On
AFor Lift travelling up to six floors or at a speed of 1.0 mps, add as below,
3For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.Floor18.00147,510.482,655,188.64
BFor Full Collective control system, add as below.
1For Lift travelling above First floor & up to Eight floorEach18.0028,433.60511,804.80
SUBHEAD-18 : ELECTRICAL SUB STATION
Boys Nanded
NCSRTRANSFORMER  (11 KV / 0.433 KV) : ESS
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz.,160 kVA, Mineral oil immersed and naturally cooled outdoor type,Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper), with HV tapping (with on load tap changer) on load +5 to -15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 5050 Watts at 50% load, 11800 Watts at 100% load as per IS:1180(part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.
160 KVA (1W+1SB)Nos.1.00683,030.40683,030.40
134NCSRHT PANEL
(11 KV - 1 VCB PANEL)
Supply,installation, testing & commissioning of indoor type floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 4X, The switchgear boards shall have a single front, single tier, fully compartmentalized, metal enclosed construction complying with clause No. 3.102 of IEC 62271-200, comprising of a row of free standing floor mounted panels. Each circuit shall have a separate vertical panel with distinct compartments for circuit breaker truck, cable termination, main bus-bars and auxiliary control devices. The adjacent panels shall be completely separated by steel sheets except in bus-bar compartments. The Service Class Continuity of Switchgears shall be LSC 2B-PM (as per IS/IEC 62271-200) • The Switchgear shall have an Internal Arc Classification of IAC AFLR. Switchgear shall have an internal arc of 31.5kA for 1 second.In case of any Inspection window provided on breaker compartment door, same should also be in line with IAC classifications. comprising of 1250Amp, continuous rated Copper busbars and droppers, 01nos. Rack-In-Rack-Out Handle, structure made from AluZinc/GI sheets to prevent corrosion and rusting.
The complete panel incl. HT and LT chamber shall be manufactured by approved OEM at its own facility, and same will be verified via stage/final inspection. License parter, system integrator, panel builder, half-panel concept is not allowed. 22 KV 7 VCB HT Panel fully encapsulated pole VCB breakers [(1+1) incomer and (6+1) outgoings], totally enclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker, having capacities as mentioned below, single break, trip free mechanism, motorised charged and auto closing breaker suitable for use on 22 KV, 3 Phase, 50 Hz A. C. supply with short circuit fault level of 21.4 kA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but continuous rated Copper busbars and droppers , Cu. earth bar, earth bar, breaker featured with mechanical ON / OFF indicator with hand trip device, spring release coil, shunt trip coil, control voltage of 24 Volt DC, TNC, LED type indicating lamps for phases and trip conditions and auxiliary switch of 6 NO + 6 NC and equipped with following switchgears and accessories.
The panel should be suitable for connections for up to 3 x 300 sq.mm XLPE 22 KV cable (cable entry from bottom/top/side), end termination with heat shrinkable jointing material etc. as required. (The Cost of end termination not included in this item)
power pack ( 1 working & 1 standby) with 220 Volt AC input & 24 Volt DC continuous output suitable for indicating lights & closing / tripping / indication of 5 Nos. HT panel boards with 2 Nos. 12 Volts each maintenance free batteries of suitable AH (Min 4 Hrs back up for each relays & indication) each, charging unit, capacitor bank for emergency delivering for trip system complete with suitable capacity of Ammeter & Voltmeter i/c connections with 2.5 sq.mm FRLS insulated copper conductor cable etc. including DC DB consisting of required MCB's for DC supply distribution to panels as required.
A)As per item no. 1 with following mountings-
Incoming - (1+1) Nos. 1250 Amp. VCB breakers with followings in each breaker -
22kV, 1250Amp, 21.4kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03 Nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti- pumping feature, and associated Shunt Trip/Close Coils (24VDC)
(a) 1 set (3 nos) 22 KV / √3 / 110 / √3 Volts drawout type PT Class 0.5 accuracy and 50 VA burden with 1 No. Voltmeter (0-24 KV), digital type, selector switch for voltmeter and protection fuses/MCB for HT metering.
(b) 3 nos. dual core dual ratio CTs of ratio 200/100/1/1A of 7.5 VA burden and accuracy class-0.5 for metering and class 5P10 for protection.
(c) 1 No. - (0-200A) Ammeter, digital type with selector switches.
(d) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having 04CT+05PT Inputs with microprocessor based protection scheme for tripping the breaker on various faults like (1) directional over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults, (3) residual and three-phase under-voltages/over-voltages (4) Synchronism and Energizing Check before breaker closing to prevent un-syncronized mixing of supplies (5) circuit-breaker-failure alarm, (6) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol. The relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. various status, Line-Current, Line-Voltage etc. and display the same locally on a built-in back-lit LCD screen as a Single- Line-Diagram with power & frequency measurements and suitably labelled status LEDs. TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software. Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.
(e) Master trip relay
(f) Trip circuit supervision relay
(g) Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, KVAH, KVARH, PF, HZ & MDI with RS 485 port.
(h) Timer and TNC switch
HT Panel - as described aboveSet1.001,084,668.001,084,668.00
AUTOMATIC POWER FACTOR CORRECTION PANEL (CAPACITOR PANEL) :
136NCSRDesign, manufacture, supply, installation, inspection, handling, assembling, affecting proper connections, testing and commissioning of 16 SWG CRCA sheet steel fabricated cubical type 60 KVAR APFC Panel-01/02/03 consisting of 1/ 2/ 5 / 10 / 15 / 20 / 25 / 50 / 60 KVAR capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 .
All MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C release.
All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified is Ics value. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT's, etc.
AC3 duty contactors should be used for switching individual capacitor banks.
The fault withstanding capacity of panel & its control gear shall be min. 35 KA rms for 1 sec.
Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose.
The maximum height of the panel should not exceed 2100 mm unless specifically approved.
INCOMING
Incomer circuit breaker has been included in the main panel.
1 set- 3 CTs , ratio 200/5A Class 1.0 accuracy 15 VA burden for metering.
1Nos- (0-200A) digital Ammeter with selector switch
Micro processor based automatic power factor control relay (3 phase) (including power factor meter) in 16 steps for automatic cut off or add on capacitor units to keep the power factor at 0.95 with variation of loads. All associated auxiliary contactors / relays shall be provided with in the scope of work.
Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit.
BUS BARS
200 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints. The current density of bus bar shall be minimum 1.3 sq mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above ambient temperature.
OUTGOINGS -
2 nos. of 100 AMPS TPN 35 KA MCCB and 120 amps AC3 duty contactor with 30 KVAR, MPP resin filled, super heavy duty ,480 V capacitor bank, with copper coil 7% detuned filters, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.Set1.00198,900.00198,900.00
SANDWICHED BUS DUCTS :
137NCSRSupplying, installation, testing and commissioning of TPN Aluminium conductor of current rating 0.8 Amps/Sqmm. LT Bus duct outdoor sandwiched type of following ratings, 50 KA rms for 1 sec suitable for connecting between transformer and main LT panel ACB including tinned copper flexible end connection at both ends and earthing with continuous 2 runs of Aluminium strips 50 x 6 mm as per specifications and as per latest IS code complete as required.
a)800 Amps. 50 KA SC for 1 sec.Metre1.0015,970.2415,970.24
b)1250 A 50kA SC for 1 secMetre1.0027,451.8427,451.84
c)1600 Amps. 50 KA SC for 1 sec.Metre1.0032,667.4432,667.44
D.G. SETS :
NCSRSupplying, erecting and commissioning of diesel generating set with alternator of 100 kVA output continuous rating, 3 phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self- regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with perfomance class G2 and maximum fuel consumption 160 ltr./ hr @ 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG.
Diesel Engine -
Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.
Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings :
Start stop switch with key
Water temperature indication
Lubrication oil pressure indication.
Lubrication oil temperature indication.
Battery charging indication
RPM indication
Over speed indication
Low Lube oil trip indication
Engine hours indication
Alternator -
Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for bus duct termination as required.
Note : - Alternator should have with all other accessories as per specified in Technical specfications.
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.
Power Controller For DG synchronization
Supplying, erecting, testing and commissioning of Microprocessor based generator control unit (synchronization panel) panel suitable for diesel generating sete, 415 Volts, 50Hz A.C. with all standard features and safeties etc. as per specification no. GEN-SYNC.
Daily service Fuel tank of rated standard capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required.
Exhaust Silencer - Exhaust manifold with residential silencer.
The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system.
Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.
Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.
100 KVASET1.001,112,002.321,112,002.32
SUBHEAD - 19: WASTE MANAGEMENT SYSTEM
NCSRIntegrated Sterilizer & Shredder (ISS) of capacity 500 LitresNo.1.008,619,000.008,619,000.00
Source of the Autoclave: System should use Non-burn technology. It should be steam sterilization method integrated with a shred-der. Process should be in one continuous automated cycle with no use of conveyor belts for transporting waste to a separate shredder. The unit should not use any chemicals
Capacity: Chamber Volume Should Be 500 ltrs. Should have a capacity to treat minimum 120kg/hr. Power: 3 phase, 400V-440v - 50/60 Hz.
Loading & Unloading: Should have an automatic system for loading & Unloading. Should have auto switch off for protection. Should have a safety system, which should prevent the cycle to start If the door of the machine is open. Chamber: The treatment vessel should be vertical (to optimize space occupied) and built of sturdy material like SS 316L or better. Chamber should be jacketed/ electrical heated for pre-heating.
Installation: Installation area should be less than 400 sq ft. Shredder: Shredder blades should be of SS 316L or better.
CYCLE: Cycle Duration: Cycle time should be less than 45 minutes. After treatment, the system should ensure substantial volume reduction in the range of 80 – 90%. Shredding time should be for minimum 7 minutes for better efficiency. It should have separate cycle with no shredding option so the machine can also be used as only an auto-clave for heavy metals.
Temperature range required: Should be 121-140 degree Celsius and pressure range of 2.4 – 5.0 bar with provision for vacuum to ensure proper sterilization. The system should able to separate liquid and the solid in the chamber itself before un-loading the treated waste. System should have option to cool down the treated material under 60 Celsius degree in less than 3mins. System should be able to take out the air (in order to have proper and efficient sterilization) before sterilization starts through a bio filter in order to avoid any hazardous air exhaust. The final treated waste should be non- Reusable. Should have audio alarm system for prining, door unlock, temperature error, pressure error.
PROCESS: The system should be able to treat a mixture and treat different types of waste in one cycle. The system should be able to treat glass, Scalpels, Blades and Needles. A system should have an automatic washing cy-cle. The system should have one test cycle to detect leakages under pressure.
OPERATION AND CONTROL: Cycle should be fully automated and controlled by a microprocessor. Automatic computerized reports of essential sterilizing parameters (selected cycle, start time, cycle stages, temperature/ pressure, end time, cycle status i.e. pass/fail) should be possible. Operator LCD Touch Screen should be present with all indica-tors (selected cycle, start time, cycle stages in graphs as well, temperature/ pressure, end time, cycle status i.e. pass/fail). A system should be able to collect the cycle data on a memory chip/card through an inte-grated slot. For optimal accuracy of sterilization parameters, the system should be equipped with at least 2 temperature sensors and two pressure transducers. A system which has a protective housing with a safety door with a safety switch will be preferred.
ACCESSORIES REQUIRED: Should have a steam generator. Stem generator should be automatically controlled by electronic system. Should have its own R.O. system for water treatment. Should have a cart or equivalent to collect treated waste. The OEM should provide the same. Should have an integrated printer for data collection and print-ing. Should have an air compressor which has metal sound proof system.
HVAC/ VRV/ VRF WORKS
PART - I : AIR CONDITIONING SYSTEM
SUB HEAD - "A" : MACHINERY
1VRF/VRV SYSTEM
1.1DSR / AOR 2019 / 1VRF/VRV OUTDOOR AC UNIT
Supply,Installation, Testing & Commissioning of modular type Variable Refrigerant Flow / Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermatically sealed invertyer type Scroll Cpmpressor(s), minimum two compressors for above 14 HP modules,microprocessor based Controller , top discharge type condensing unit(s), with R 410 A Refrigerant , vibration isolators , with suitable foundation etc.complete as required.The unit shall deliver the rated capacity at AHRI Conditions and work even at 50 °C ambeint temperature without tripping. The unit shall be suitable to work on 400 V+/-10 % , 3 Phase , 50 Hz AC power supply.The unit shall be filled with first charge of refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 .
Outdoor units shall have external static pressure of minimum 75 Pa to avoid any hot circulation.
It is mandatory that each compressor shall have inverter technology separately i.e; outdoor units shall have all inverter based compressor.HP21.0016,415.00344,715.00
3.2DSR / AOR 2019 / 2VRF/VRV INDOOR AC UNIT - 4 WAY CASSETTE
Supply,installation,testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter,fan section with low noise fan/dynamically balanced blower,multispeed motor,coil section with DX Copper coil,electronic expansion valve,outer cabinet,drain pump,grill,necessary supports,vibration isolation,cordless remote control etc.,suitable for operation on single phase230V±10%,50Hz AC supply,complete,as required.The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree CDB and 19 Degree CWB temperature.
3.2.1DSR / AOR 2019 / 2.52 TRHP1.0030,801.0030,801.00
3.2.2DSR / AOR 2019 / 2.104 TRHP12.0033,981.00407,772.00
4DSR / AOR 2019 / 5COPPER REFRIGERANT PIPING
Supply,installation,testing and commissioning of including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV /VRF system, complete with fittings , with suitable adjustable ring type hanger supports , jointing / brazing including accessories , insulated with XLPE Class-O tubular insulation / with Class -o closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid Lines ,all accessories as per specification etc.as required:
Note:- 1)The Copper Piping & Piping Circuit should be with Minimum Number of joints,which shall be attained by: (i) Using One End Expanded Tubes. (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes. (4) The thickness of fittings used shall be same as that of the pipe.
4.1DSR / AOR 2019 / 5.16.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.m9.00245.002,205.00
4.2DSR / AOR 2019 / 5.29.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.m9.00331.002,979.00
4.3DSR / AOR 2019 / 5.312.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.m9.00466.004,194.00
4.4DSR / AOR 2019 / 5.415.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.m9.00588.005,292.00
4.5DSR / AOR 2019 / 5.519.0 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.m9.00707.006,363.00
4.6DSR / AOR 2019 / 5.622.2 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.m9.00865.007,785.00
4.7DSR / AOR 2019 / 5.725.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation.m9.001,022.009,198.00
4.8DSR / AOR 2019 / 5.828.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation.m9.001,108.009,972.00
4.9DSR / AOR 2019 / 5.931.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation.m9.001,170.0010,530.00
4.10DSR / AOR 2019 / 5.1034.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation.m9.001,230.0011,070.00
4.11DSR / AOR 2019 / 5.1138.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation.m9.001,265.0011,385.00
4.12DSR / AOR 2019 / 5.1241.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation.m9.001,309.0011,781.00
5MRAnticorrosive Coating on VRV-ODU, Brazing Joints of Cooling CoilEach2.00113,280.00226,560.00
6OUTDOOR STAND FABRICATION
MRSupply,fabrication and erection of Angle/Channel/Flat iron stand ,hanging arrangement for air conditioning machines & ducts etc.Back /Support clamps or other similar work etc.including nuts ,bolts of required size,making holes,fabrication,welding,cutting,etc.and painting with one coat of red oxide paint & two coat of enamel paint as required as per specification.Kg9.00170.001,530.00
7Central Controller for Indoor & Outdoor Units
Supply, installation, testing & commissioning of Central Controller capable of controlling of all IDUs, ODUs complete with necessary hardware, accessories etc. to perform the following functions:
Control of IDUs, ODUs Units as above with monitoring of vital parameters such as temperature sensing & setting, ON/OFF, status etc.
Permit / prohibit function of each remote controlled unit.
Operation of units in individually or in group.
Fault indication with Alarm.
MRThe central controller will be complete including all hardware & software (including wiring) suitable to perform above function.Each1.0080,240.0080,240.00
8CONTROL & TRANSMISSION WIRING
8.1MR Supply,installation,testing and commissioning of 2core X 1.5 mm² copper wire in PVC conduit as per specifications ( for transmission) m9.00142.001,278.00
9Isolator
9.1MRProviding & fixing weather proof isolator near each outdoor unit.Each2.0018,880.0037,760.00
SUB HEAD - "C" : DUCTING , GRILLES & INSULATION
1Rectangular / Flat Oval Ducting ( Factory fabrication )
Supply, fabrication, installation, balancing and commissioning of factory fabricated G.S.S.sheet metal rectangular /flat oval ducting complete with neoprene rubber gaskets,elbows,splitter dampers,vanes,hangers,supports etc. as per approved drawings and specifications of following sheet thickness complete as required
1.116.12.1.1(Thickness 0.63mm sheet)sqm34.001,080.0036,720.00
1.216.12.1.2 (Thickness 0.80mm sheet)sqm26.001,263.0032,838.00
1.316.12.1.3(Thickness 1.00mm sheet)sqm17.001,381.0023,477.00
1.416.12.1.4(Thickness1.25mm sheet)sqm13.001,836.0023,868.00
2Rectangular / Square Ducting (Site fabricated )
Supply, installation balancing and commisnioning of site fabricated GSS sheet metal ducts rectangular ducting complete with neoprene rubber gaskets,elbows,splitter,dampers,vanes,hangers,supports etc as per approved drawings & specification of following sheet thickness
2.116.12.2.1Thickness 0.63 mm sheet sqm26.001,058.0027,508.00
2.216.12.2.2Thickness 0.80 mm sheet sqm22.001,229.0027,038.00
2.316.12.2.3Thickness 1.00mm sheet sqm17.001,629.0027,693.00
316.20 Fire Dampers
Supply,Fixing, testing & commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored.The spring return action shall be in built mechanism and not externally mounted.The damper shall also be closed in the event of fire signal complete as required and as per specifications.
3.116.20.1Fire DamperSMT2.0010,659.0021,318.00
3.216.20.2ActuatorSets4.009,948.0039,792.00
416.15Supply & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.SMT1.009,105.009,105.00
516.16Supply & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers as per specifications.SMT2.005,910.0011,820.00
616.17Supply, fixing testing commisioning of Supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. SMT2.0012,184.0024,368.00
716.18Supply, fixing testing commisioning of Return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core. SMT2.008,121.0016,242.00
816.13Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubbergaskets,nuts,bolts,screws linkages,flanges., as per specifications.SMT2.007,046.0014,092.00
9MRSupplying & fixing of 18 G thick Aluminium extruded powder coated Fresh / Exhaust air weather protected louvers with bird screen type (with Aluminium frames if required) for ventilation with 12G GI wire mesh as per specification and sizes will be as per tender drawing mentioned.SMT1.008,496.008,496.00
1016.23 INSULATION WORKS
Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class"O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. Thejoints shall be 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
10.116.23.119 mm thick for Return Air DuctSMT102.00754.0076,908.00
10.216.23.225 mm thick for Supply Air DuctSMT85.00968.0082,280.00
1116.21DUCT ACCOUSTIC LINING
Supply and fixing of accoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³,with 25 mm X 25 mm GI section of 1.25 mm thick,at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts,bolts,syick pins , CPRX compound etc.complete as required and as per specificationsSMT9.00708.006,372.00
1216.22Acoustic Insulation of AHU Rooms
Supply and fixing of accoustic lining on wall and ceiling of AHU rooms with 50 mm thick density of 32 kg/m³ resin bonded glass fibre insulation friction fixed in 610 mm X 610 mm frame work made of 25 X 50 X 50 X 50 X 25mm made out of 0.6 mm thick GI sheet U shapedchannel and covered with Reinforced fibre glass tissue and finished with 0.80 mm perforated aluminium sheet etc , complete as required and as per specifications.SMT13.001,229.0015,977.00
SUB HEAD - "D" : ELECTRICAL WORKS
1SUB - PANELS FOR AIR HANDLERS
Supply ,installation, testing and commissioning of Cubical wall mounted type switch board made of 2mm thick CRCA sheet as detailed below & conforming to the specifications.
Note: The HVAC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder for AHU Fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him.
1.2 For AHU ( 7.5 HP Fan Motor)
32A TPN MCB for 32 A AHU starter panel, overload relay,start / stop push buttons, phase indication lights with protection fuse, on / off / trip indication lights with protection fuse, ammeter ( 0-32 A) with single CT, single phase preventer. Auto Manual Selector switch. MCB shall be of 10KA
MRControls & interlocking accessories as required. LOTN0S6.0033,040.00198,240.00
1.3 For AHU (15 HP Fan Motor)
63 A TPN MCCB for 63 A AHU starter panel, overload relay,start / stop push buttons, phase indication lights with protection fuse, on / off / trip indication lights with protection fuse, ammeter ( 0- 63 A) with single CT, single phase preventer. Auto Manual Selector switch. MCB shall be of 25KA
MRControls & interlocking accessories as required. LOTN0S1.0033,040.0033,040.00
2POWER & CONTROL CABLING
Supplying, laying, effecting proper termination, testing & commissioning of the following POWER CABLE sizes of 1.1 KV - PVC inner sheated,extruded PVC type ST2 sheathed & Galvanised steel strips/wire as per IS 7908 (Part-I) armoured aluminium conductor cables conforming to relevant latest amended Indian Standardsas per specification standard.
2.1MR4C x 10 Sq. mm RMT26.00450.0011,700.00
2.2MR3C x 10 Sq. mm RMT26.00239.006,214.00
2.3MR3C x 6 Sq. mm RMT132.00185.0024,420.00
2.4MR3C x 4 Sq. mm RMT132.00150.0019,800.00
2.5MR4C x 50 Sq. mm RMT132.001,500.00198,000.00
3Earthing Strip / Wires.
3.15.18Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring / cable as required.RMT1,282.0042.0053,844.00
4Cable Tray
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
4.14.1.2150 mm x 50 mm x 1.6 mm (for AHU Room)RMT68.00604.0041,072.00
4.24.1.4300 mm x 50 mm x 1.6 mm (for AHU Room)RMT51.00777.0039,627.00
4.34.1.6450 mm x 62.5 mm x 2.0 mm ( for Terrace Floor)RMT43.001,137.0048,891.00
4.44.1.11600 mm x 62.5 mm x 2.0 mm (for Terrace Floor)RMT34.001,463.0049,742.00
PART - II : MECHANICAL VENTILATION SYSTEM
SUB HEAD - "A" : MACHINERY
1Liftwell , Lift Lobby & Staircase Pressurisation
Supply, erection, testing and commissioning of ceiling hunged Tube Axial flow fans with adjustable pitch blade , MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4 pole, three phase A.C supply of class "F" insulation with support, mountings with vibration isolator spring and fire rated canvas flexible connection etc. & of following capacity as per approved shop drawings.
1.1For Staircase Pressurisation :
For Fire Escape Staircase :
1.1.1Staircase For Services
Air Qty. = 15,000 CFM
Static Pressure = 30 mm Wg
Fan Speed = Not exceed 1450 rpm
Motor = Not exceed 7.5 Kw.
MRdB level : not exceed 78 @ 3 mtrs open atmosphere condition.Nos.3.00169,920.00509,760.00
1.1.2Lift Lobby
Air Qty. = 21,000 CFM
Static Pressure = 30 mm Wg
Fan Speed = Not exceed 1450 rpm
Motor = Not exceed 7.5 Kw.
MRdB level : not exceed 78 @ 3 mtrs open atmosphere condition.Nos.1.00237,888.00237,888.00
1.1.3Lift Well
Air Qty. = 14,000 CFM
Static Pressure = 30 mm Wg
Fan Speed = Not exceed 1450 rpm
Motor = Not exceed 5.5 Kw.
MRdB level : not exceed 78 @ 3 mtrs open atmosphere condition.Nos.3.00158,592.00475,776.00
2KITCHEN VENTILATION
Supply, erection, testing and commissioning of ceiling hunged / Floor mounted type Exhaust Scrubber (Dry Type ) & Air washer , complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4 pole, three phase A.C supply of class "F" insulation with support, mountings with vibration isolator spring and fire rated canvas flexible connection etc. & of following capacity as per approved shop drawings.
2.1.1Exhaust Scrubber
Air Qty. = 15,000 CFM
Static Pressure = 30 mm Wg
MRdB level : not exceed 78 @ 3 mtrs open atmosphere condition.Nos.1.00169,920.00169,920.00
2.1.2AIR Washer
Air Qty. = 21,000 CFM
Static Pressure = 30 mm Wg
MRdB level : not exceed 78 @ 3 mtrs open atmosphere condition.Nos.1.00237,888.00237,888.00
SUB HEAD - "B" : ELECTRICAL WORKS
3Kitchen Ventilation
MRSupplying, Installation, Testing & Commissioning of Floor Mounted panel for Pressurisation fabricated out of 14 SWG sheet steel. The panel should be compartmentalized, free standing, floor mounted, dust and vermin proof. The panel shall be treated for anti corrosive processes (7 tank process) before powder coating. Cable gland plates shall be provided in the panel. Panels shall be suitable for 415 V, 3-phase 4 wire, 50 Hz supply. Set1.00155,760.00155,760.00
A)INCOMER :
250 A TPN MCCB with (0 - 400A) ammeter with three CT & selector switch, (0 - 500 V) voltmeter with selector switch, phase indication light with protection fuse. MCCB shall be of 25KA SET-01
B) Bus BAR
Bus Bar for 250 A capacity, four pole ACB. SET 01
C)OUTGOING :
C.1)For 1 Nos. 12. HP / 7.5 KW Exhaust Scrubber Fan Motor
1NOS 32 A TPN MCB with 32 A Star Delta starter, overload relay, start / stop push buttons, on / off / trip indication lights with protection MCB fuses, ammeter ( 0- 32 A) with three CT, single phase preventer / auto manual selector switch. MCCB shall be of 16KA
C.2)For 1 Nos. 7.5 HP / 5.5 KW Airwasher Fan Motor
3 NOS 25 A TPN MCB with 25 A DOL starter, overload relay, start / stop push buttons, on / off / trip indication lights with protection MCB fuses, ammeter ( 0- 25 A) with three CT, single phase preventer / auto manual selector switch. MCCB shall be of 16KA.
Note: The HVAC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder for Ventilation Fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him.
3POWER & CONTROL CABLING
Supplying, laying, effecting proper termination, testing & commissioning of the following POWER CABLE sizes of 1.1 KV - PVC inner sheated,extruded PVC type ST2 sheathed & Galvanised steel strips/wire as per IS 7908 (Part-I) armoured aluminium conductor cables conforming to relevant latest amended Indian Standardsas per specification standard.
3.1MR3C x 4 Sq. mm RMT26.00241.006,266.00
4Earthing Strip / Wires.
4.15.18Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring / cable as requiredRMT17.0042.00714.00
5Cable Tray
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
5.14.1.1100 mm x 50 mm x 1.6 mmRMT17.00543.009,231.00
1
SUB HEAD - "C" : SPLIT AC & HEAT PUMP WORKS
Split Unit Airconditioners
1Hi Wall Split Unit
Supply, Installation, testing and commissioning of high wall mounted split unit airconditioners with evaporator with fan with motor, cooling coil, filter, all enclosed in decorative plastic casing, condenser with hermatically sealed compressor, condenser coil, propeller fan with motor, inter connecting refrigerant piping, electrical panel with cabling and earthing, cordless remote control, M.S. frame for mounting condensing unit. (with 10 Rmt. circuit length of refrigerant piping with cabling and earthing).
1.1MR2.0 TRNos.1.0066,080.0066,080.00
1.2MR1.5 TRNos.1.0059,605.0059,605.00
FURNITURE WORKS
Office
1Model: PRIMUS Overall Size: 2000Wx1860Dx750H mm. Supplying, and placing in position of Primus office table Side Cabinet direction : Left-hand side~ Size : 2000 X 1850 X 750 mm~ Particle Board Melamine~ Reverse Wire Box The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.1.00100,880.00100,880.00
2Back Storage Size: 2400Wx450Dx750H mm. Supplying, and placing in position of storage as per photograph/drawing . The storage unit having Openable shutters with shelf in it. The modular storage unit top shall be made from 18 mm thick pre-laminated particle board and rest of the sides as well as shelves and shutter to be made up of 18 mm thick pre-laminated particle board while back to be made of 8 mm thick pre-laminated particle board. All edges to be provided with 2 mm thick PVC lipping. The storage unit having openable shutters withD shape handles & locking arrangement. The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.1.0038,800.0038,800.00
3Model: OTTAWA/HB Ottwa/Hb : High Back Chair - Colour : Rxt051-3 (Front) | Rxt051-16 (Back) - Fixed Armrest - Butterfly Mechanism - Chromed Gaslift - 350mm Chromed Base - White Pu Casters Overall Size: 560Wx500Dx440-520/1135-1215 mm. The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.1.0025,026.0025,026.00
4Model: OTTAWA/MB Ottwa/Mb : Medium Back Chair - Colour : Rxt051-3 (Front) | Rxt051-16 (Back) - Fixed Armrest - Butterfly Mechanism - Chromed Gaslift - 320mm Chromed Base - White Pu Casters Overall Size: 560Wx500Dx440-520/985-1065 mm. The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.2.0023,668.0047,336.00
5Model: Stevens, Velvet 3 Seater Sofa in Dark Blue Dimension: (W)2080mm X (D)970mm X (H)960mm Material & Subtype Fabric - Velvet, Solid Wood - Steam Beech Wood, Frame Material Solid Wood, Upholstery Material Fabric - Velvet, Filling Material Foam, Seat Material Fabric - Velvet, Leg Material Solid Wood, Finish Matte, Colour & Colour Family Blue - Dark The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.4.0051,410.00205,640.00
6Model: Juda, King Size Bed in Frosty White Finish with LED Light Dimension: (W) 1880mm X (D) 2040mm X (H) 920mm Seating Height: 310mm, Headboard Height: 635mm Material & Subtype: Laminate, Engineered Wood - Particle Board Headboard Material: Engineered Wood, Laminate, Base Material: Engineered Wood, Frame Material: Engineered Wood, Laminate, Finish: Matte, Colour & Colour Family: White - Frosty, Brown - Urban Teak The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.1.0036,472.0036,472.00
7Model: Juda, Bed Side Table in Frosty White Dimension: (W) 500mm X (D) 400mm X (H) 450mm Material & Subtype Engineered Wood - Particle Board, Laminate Base Material Engineered Wood, Finish Matte, Colour & Colour Family White - Frosty, Brown - Urban Teak all complete as per specifications and direction of Engineer-in-Charge. The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.orgNos.2.008,148.0016,296.00
8Model: Juda, 2 Door Wardrobe in Frosty White Dimension: (W) 800mm X (D) 550mm X (H) 1950mm Material & Subtype Laminate, Engineered Wood - Particle Board Frame Material Engineered Wood, Laminate Finish Matte Colour & Colour Family White - Frosty The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.1.0028,712.0028,712.00
Dinning Hall
9Canteen Table Size: 2400Wx900Dx750H mm. Supplying, and placing in position of the table top shall be made out of 25mm thk. laminate with PVC edges. Tabletop supported on Mild Steel 50mm x50mm C- shaped Leg and Horizontal connectors with Powder coating of 50 Micron. The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.7.0038,800.00271,600.00
10Supplying and Placing in Position of stackable modern design cafeteria chair - coco material : synthetic fiber size : 381mm(l)x 419mm(d)x 839mm(h). colour : red/blue/yellow/black / finish : shiny for legs, Supplying & providing cafeteria chair size is 381mm(l)x 419mm(d)x 839mm(h) a combination of synthetic fiber with stainless steel make the products utile and a delight, the complete structure shall be made up of 20% glass filled blow molded high-density polyethylene andis,the frame structure shall be supported by ( 2 straight + 2 slant ) four legs.the tubular welded frame is made from dia2.22 +/- 0.03cmx 0.12+/- 0.0128 cm and 3.5+/- 0.03 cm x 0.12+/- 0.0128 am stainless steel 202 grade tube & the tube are buff polished to give shiny finish.seat and in back given handle to hold are made of injection moulded high impact strength polypropylene polymer compound with indoor grade uv resistance and pressed fitted with legs.the chair is easy to store when not in use, since you can stack up to 6 chairs on top of each other. The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.55.004,041.02222,256.10
Room
11Model: Alister, Single Bed in Walnut Finish with LED Light Dimension: (W) 1025mm X (D) 2170mm X (H) 990mm Seating Height: 320mm, Headboard Height: 680mm Material & Subtype: Engineered Wood - Particle Board, Headboard Material: Engineered Wood, Frame Material: Engineered Wood, Finish: Matte, Colour & Colour Family: Brown - Walnut The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.46.0022,504.001,035,184.00
12Model: Vienta, Bed Side Table with Spacious Open Storage Dimension (W) 400mm X (D) 250mm X (H) 450mm Material & Subtype Laminate, Engineered Wood - Particle Board Frame Material Engineered Wood, Finish Matte, Colour & Colour Family Brown - Brentwood Oak The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.46.002,910.00133,860.00
13Model: Delrick Study Desk Size: 1050Wx600Dx760H mm. Supplying and placing in position of modular study table creating beautiful spaces for you within your homes and offices since 1985, structure of rectangle -shape table top offers generous space, desk primary work surface use premium quality materials, which give more surface area for work, table top made of 25mm thick prelaminated particle board of grade ii type iii of is 12823/latest. Left side Tabletop supported on 18 mm thick prelaminated particle board. work surface with the exposed edges shall be finished with 2mm thick edge binding tape of matching colour and shade with the hot melt glue. Fixed pedestal: 350 mm(l)x 600 mm(d)x 755 mm(h), fixed pedestal top, side bottom made of 18 mm thick prelaminated particle board, open carcass with 2 fixed shelve. Easy to maintain / warp and scratch resistant / borer and termite resistant. Three layer prelaminated particles board (wood product) of grade ii type iii of is 12823/latest. The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.46.0010,670.00490,820.00
14Model: Delight, Mesh Medium Back DIY Chair Dimension: 615Wx670Dx1110H mm. Seating Height: 560mm, Seat depth: 480mm, Back Height:560mm Supplying, and placing in position of sleek, minimal, and modern, the Delight office chair makes for a handsome addition to your home office. The breathable cushioned mesh back subtly curves to provide perfect lumbar support. Perching atop a sturdy metal base with premium castors for fluid movement.Material & Subtype: Mesh - Fabric, Upholstery Material: Fabric,Mesh, Seat Material: Fabric, Leg Material: Nylon, Finish: Matte, Mechanism: Synchro Single Locking, Function: Pneumatic Height Lift,Revolving,Tilt Tension Control The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.46.007,178.00330,188.00
15Model: Alister, 2 Door Wardrobe with External Drawer Dimension: (W) 900mm X (D) 550mm X (H) 1950mm Supplying, and placing in position of 2 door wardrobe Material & Subtype Solid Wood - Steam Beech Wood, Laminate, Engineered Wood - Particle Board, Frame Material Engineered Wood, Laminate, Finish Matte, Colour & Colour Family Brown - Walnut The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.46.0032,010.001,472,460.00
Reading Room
16Reading Table Size: 1800Wx900Dx750H mm. Supplying, and placing in position of the reading table top shall be made out of 25mm thk. laminate with PVC edges. Tabletop supported on Mild Steel 50mm x50mm C- shaped Leg and Horizontal connectors with Powder coating of 50 Micron. The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.6.0031,525.00189,150.00
17Model: Stephanie, Multipurpose Outdoor Chair in Dual Tone Dimension (W) 420mm X (D) 450mm X (H) 860mm Seating Height 470mm Material & Subtype Plastic - Polypropylene, Frame Material Polypropylene, Seat Material Polypropylene, Leg Material Polypropylene, Finish Matte, Colour & Colour Family Black, Brown - Tan The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.31.006,790.00210,490.00
Lobby
18Model: Jordana, Leatherette 3 Seater Sofa Dimension: (W) 2000mm X (D) 940mm X (H) 895mm Seating Height: 520mm, Arm height: 670mm, Seat Depth: 520mm, Back Height: 410mm A modern blend of good quality and thoughtful design, Pure by Durian is a label that is created to bring new-age furniture pieces that enhance your lifestyle and align with your values.Material & Subtype Solid Wood - Steam Beech Wood, Premium Leatherette, Frame Material Solid Wood, Upholstery Material Premium Leatherette, Filling Material Loose Fiber, Foam, Seat Material Premium Leatherette, Leg Material Solid Wood, Finish Matte The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.4.0046,754.00187,016.00
19Model: Franco, Veneer Side Table in Mohagany Finish Dimension: (W) 600mm X (D) 600mm X (H) 550mm Material & Subtype Veneer - Oak Veneer, Solid Wood - Rubber Wood, Engineered Wood - MDF Table Top Material Veneer, Frame Material Engineered Wood, Leg Material Solid Wood, Finish Matte, Colour & Colour Family Brown - Mohagany The Seller / Company should be ISO 9001:2015, ISO-14001:2015, ISO-37001:2016, OHSAS 18001:2007, ISO-45001:2018, ISO-50001:2018, GRIHA, GREENPRO, GREEN GUARD, INDIAN DESIGN MARK, AIOTA, FSC, BIFMA Level- 1 certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA COMPLAINT as well as BIFMA LEVEL-1 certified and an official product link/screenshot of the product listing's must be provided from www.bifma.org all complete as per specifications and direction of Engineer-in-Charge.Nos.6.009,312.0055,872.00
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
TOTAL FIGURES 275,661,487.36