Bidhelp
Postgraduate Institute of Medical and Education and Research Chandigarh||Engineering department - PGIMER Chandigarh||H.E.(Construction) - PGIMER Chandigarh
Postgraduate Institute of Medical and Education and Research Chandigarh||Engineering department - PGIMER Chandigarh||H.E.(Construction) - PGIMER Chandigarh
H.E. Construction
Chandigarh QTY :

Items - Repair of expansion joint and flooring of NHE connecting corridor, NHE, PGIMER, Chandigarh.

Tender Details
Costs
Documents
BOQ

BoQ1

Percentage BoQ
BoQ_Ver3.0PercentageNormalINR OnlyINR
Select, At Par, Excess (+), Less (-)IOCL
Tender Inviting Authority: H.E. (Construction)
Name of Work: Repair of expansion joint and flooring of NHE connecting corridor, NHE, PGIMER, Chandigarh.
Contract No: PGI/Engg./Const./2025/218
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated Rate in Rs. PAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Rs. P Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. PTOTAL AMOUNT With TaxesTOTAL AMOUNT In Words
123345789101112131415161718192021222324252627282930313233343536373839404142434445464748495051526547
1Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:BI01010001010000000000000515BI01000011131.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
1.11:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources).BI01010001010000000000000515BI01000011140.350Cum8519.20Excess(+)1Full ConversionINR2981.722981.72INR Two Thousand Nine Hundred & Eighty One and Paise Seventy Two Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
2Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints.BI01010001010000000000000515BI01000011163Supplying, Conveying and fixing spls. Including eaitem410Nos
2.1200 mm wide.BI01010001010000000000000515BI01000011176.100Mtr859.75Excess(+)1Full ConversionINR5244.485244.48INR Five Thousand Two Hundred & Forty Four and Paise Forty Eight Only1.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
3Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. BI01010001010000000000000515BI01000011181.02Construction of chamber for 100mm sluice platesitem2213Nos
3.1Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063).BI01010001010000000000000515BI01000011192Construction of chamber for 100mm sluices valveitem310Nos
3.2Floor Joint of 200 mm gapBI01010001010000000000000515BI01000011206.100Mtr9903.65Excess(+)1Full ConversionINR60412.2760412.27INR Sixty Thousand Four Hundred & Twelve and Paise Twenty Seven Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
4Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in ofice Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063).BI01010001010000000000000515BI01000011211.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
4.1Wall Joint of 200 mm gapBI01010001010000000000000515BI01000011229.150Mtr6889.05Excess(+)1Full ConversionINR63034.8163034.81INR Sixty Three Thousand &Thirty Four and Paise Eighty One Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
5Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).BI01010001010000000000000515BI0100001123118.000Kg772.40Excess(+)1Full ConversionINR91143.2091143.20INR Ninety One Thousand One Hundred & Forty Three and Paise Twenty Only2Construction of chamber for 100mm sluices valveitem310Nos
6Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :BI01010001010000000000000515BI01000011241.01Supplying, Conveying and fixing spls. Including eartitem1123.223Nos
6.1Udaipur green marbleBI01010001010000000000000515BI010000112511.150Sqm2428.60Excess(+)1Full ConversionINR27078.8927078.89INR Twenty Seven Thousand &Seventy Eight and Paise Eighty Nine Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
7Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.BI01010001010000000000000515BI01000011262Construction of chamber for 100mm sluices valveitem310Nos
7.1Nominal concrete 1:3:6 or richer mix (including equivalent design mix)BI01010001010000000000000515BI01000011270.350Cum2434.25Excess(+)1Full ConversionINR851.99851.99INR Eight Hundred & Fifty One and Paise Ninety Nine Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
7.2Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)BI01010001010000000000000515BI01000011280.350Cum1503.60Excess(+)1Full ConversionINR526.26526.26INR Five Hundred & Twenty Six and Paise Twenty Six Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
8Dismantling laid in cement mortar including stacking of material within 50 metres lead.BI01010001010000000000000515BI01000011291.850Sqm266.45Excess(+)1Full ConversionINR492.93492.93INR Four Hundred & Ninety Two and Paise Ninety Three Only2Construction of chamber for 100mm sluices valveitem310Nos
9Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.BI01010001010000000000000515BI01000011301.000Cum263.95Excess(+)1Full ConversionINR263.95263.95INR Two Hundred & Sixty Three and Paise Ninety Five Only3Supplying, Conveying and fixing spls. Including eaitem410Nos
10Add difference of Water Charges @ 0.50%BI01010001010000000000000515BI01000011321.000INR1260.15Excess(+)1Full ConversionINR1260.151260.15INR One Thousand Two Hundred & Sixty and Paise Fifteen Only1.02Construction of chamber for 100mm sluice platesitem2213Nos
Total in Figures253290.65253290.65INR Two Lakh Fifty Three Thousand Two Hundred & Ninety and Paise Sixty Five Only4Construction of chamber for 100mm sluice platesitem510Nos
Quoted Rate in FiguresSelect0.000.00INR Zero Only