Bidhelp
National Institute of Technology Calicut||Engineering Unit 1 - NIT Calicut
National Institute of Technology Calicut||Engineering Unit 1 - NIT Calicut
Director
Kerala QTY :

Items - Combined Electrical works at various location in NITC

Tender Details
Costs
Documents
BOQ

BoQ1

Item Rate BoQ
BoQ_Ver4.0Item RateNormalINR OnlyINR
Select, Excess (+), Less (-)Less (-)
Tender Inviting Authority: Director, NIT Calicut
Name of Work: Combined Electrical works at various location in NITC
Contract No: i) Engg/EMU/TA3/2025-26/0001/Three phase-ECED ii)Engg/EMU/JE1/032/Material testing lab architecture iii)Engg/EMU/AE/2024-25/UG cable for Name Board iv)Engg/EMU/AE-101/Health centre/2025
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
Sl. No.Item DescriptionItem Code / MakeQuantityUnitsEstimated RateAddition / DeductionAddition / Deduction ValuesCurrency Convertion against each ItemQuoted Currency in INR / Other CurrencyBASIC RATE In Figures To be entered by the Bidder Rs. P Excise DutyVATFreight Charges ( Unloading & Stacking)Any Other Taxes/Duties/LeviesOther Taxes 2IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service TaxLess for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without TaxesTOTAL AMOUNT With TaxesTOTAL AMOUNT In Words
12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455
1Three Phase ECEDitemH11Construction of chamber for 100mm sluices valveitem1101 Nos
1.001 Wiring for circuit/ submain wiring alongwith 4 x 10 sq mm + 2 x 6 sq mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed pvc conduit as required.70.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.002Wiring for circuit/ submain wiring alongwith 4 x 16 sq mm + 2 x 6 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.30.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.003Supplying and drawing 3 x 2.5 sq mm FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.200.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.004Supplying and fixing of 20 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required25.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.005Supplying and fixing of 25 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required50.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.006Supplying and fixing 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc.as required26.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.007Supplying and fixing 6 pin 15/16 A modular socket ( 3 MD type ) on the existing modular plate & switch box including connections but excluding modular plate etc.as required26.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.008Supplying and fixing 4 module (125 mm X 75 mm) GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.009Supplying and fixing 8 module (125 mm X 125 mm) GI box alongwith modular base & cover plate for modular switches in recess etc. as required.10.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.01Providing and fixing 100 A , 4P MCCB, 16 KA breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing MCCB DB , making conection as required.1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.011Supplying and fixing 8 way Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar. interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)3.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.012Supplying and fixing 3 phase 4 way (8+12) double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB)1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.013Supplying and fixing 6 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.014Supplying and fixing of 4 ways (8+12) , Double door. surface/ recess mounting. vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.)1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.015Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.10.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.016Supplying and fixing 32 A rating Triple pole , 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.2.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.017Supplying and fixing 32 A rating 4 pole , 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.2.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.018supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required20.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.019Supplying and fixing 40 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc, as required.2.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.02Supplying and fixing 63 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc, as required.1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.021Supplying and fixing 40 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc, as required.2.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.022Supplying and fixing 63A , Four pole, 430 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.023Supplying and fixing 63A , Triple pole, 415 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc..1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.024Supplying and fixing 40 A , Four pole, 430 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc. as required.4.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.025Supplying and fixing 40A , three pole, 430 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.026Supply of 4 x 50 Sq.mm PVC/ XLPE Aluminium Armoured Cable, 650/1100V. Grade confirming to IS:7098 (Pt-1)198815.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.027Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement, watering pipe of 2.7 metre long etc.with charcoal/coke and salt as required.1.000SetExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.028Supplying and laying 25mm x 3mm strip at 0.05 metre below ground as earth electrode, including connection/ terminating with SS nut,bolt,spring washer , double plate washer etc.as required ( jionting shall done by overlapping and with 2 set GI nut bolt and washer spaced 50mm)30.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.029Providing and fixing 25 mm X 6 mm G.I strip on surface or in recess for connections etc. as required.1.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.03Supply 60kg of earthing compound (EXCEL compound or equivalent) etc. as required.60.000kgExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.031Supply and laying of one number of 8 SWG good quality bare copper wire for loop earthing along with existing XLPE insulated aluminium cable as required.25.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.032Laying and fixing of Above 35 sq mm and upto 95 sq mm (clamped with 25 x 3 mm MS flat clamp) PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size on wall surface as required.15.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.033Supplying and making end termination with brass compression gland providing sutable size gland earthing and aluminium lugs for 4 x 50 sq mm PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.034supplying and making end termination of suitable size for the submain wiring with Copper lugs for 4x10 + 2x6sqmm of PVC insulated copper conductor10.000SetExcess(+)1Full ConversionINR0.000.00INR Zero Only
1.035supplying and making end termination of suitable size for the submain wiring with Copper lugs for 4x16+ 2x6sqmm of PVC insulated copper conductor6.000SetExcess(+)1Full ConversionINR0.000.00INR Zero Only
2Material testing lab architecture
2.01MCB
2.011Supplying and fixing 40 to 63A rating, Three pole (Three phase ) 415 Volts, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of triple pole in the existing MCB DB complete with connections, testing and commissioning etc as required.1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.012Supplying and fixing 63A rating, Four pole, Three phase, 415 Volts, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of four pole in the existing MCB DB complete with connections, testing and commissioning etc as required. 1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.02Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2.0214 X 16 sq. mm + 2 X 6 sq. mm earth wire23.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.0224 X 4 sq. mm + 2 X 4 sq. mm earth wire46.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.03End termination
2.031Supplying and making end termination of suitable size for the submain wiring with Copper lugs for 4x16 + 2x6sqmm of PVC insulated copper conductor 2.000SetExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.04Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.04163A1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.05Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.)
2.0518 way (8 + 24), Double door1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.06Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
2.061Triple pole2.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.062Single pole1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.07Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2.0713 x 2.5 sq. mm15.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.08Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
2.08120 mm15.000MetreExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.09Supplying and fixing FP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve FP MCB complete with connections, testing and commissioning etc. as required.2.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.1Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.1.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
2.11Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required.18.000EachExcess(+)1Full ConversionINR0.000.00INR Zero Only
3UG CABLE FOR NAME BOARD
3.01Supplying of one number 2C x 6 Sq.mm size Aluminium conductor XLPE insulated PVC sheathed power cable of 1.1 kV grade etc. as required.265.000mtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.02Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 2 C x 6 sq.mm in the existing DWC HDPE pipe/ Metal pipe as required.225.000mtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.03Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.205.000mtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.04Supply and laying of 3 inch 80 NB GI pipe (medium class B) on ground with all accessories like socket, bend, couplers with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., and making good the damages of road with concrete mixture of 1 : 2 : 4 including watering & ramming etc. as required.18.000mtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.05Supplying and fixing 6-32 A rating, 240/415 V, 'C' curve miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
3.051Single pole14.000NosExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.06Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
3.06125A4.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.07Supplying and drawing 3 numbers 2.5 sq mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in existing surface / recessed PVC conduit as required.52.000mtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.08Supplying and fixing of 20mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.48.000mtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.09Supply and making end termination with brass compression gland and aluminium legs for 2 C x 6 sq.mm (19 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.spacing not exeed 50 cm etc. as required.12.000NosExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.1Supply and laying of one number of 14 SWG good quality bare copper wire for loop earthing along with existing XLPE insulated aluminium cable as required.321.000mtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.11Supplying and fixing 4 pole MCB metal enclosure on surface / recess, complete with earth bar, din bar, detached gland plate, interconnection, phosphetized and powder painted including earthing etc. as required.4.000NosExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.12Supplying and fixing of weather proof outdoor junction box for outdoor installation of size 205mm x 255mm x112mm with knockouts for cable entry including dinbar, suitable connectors for connecting Al cable to copper cable of suitable size, provision for fixing two number of double pole MCB, weather proof gourmets,glands,clamps,screws of required length fastners connections for surface/ recess fixing on existing tubular pole etc. as required(clip type)Hensel IP 69 KF 2525G made or Equivalent.7.000NosExcess(+)1Full ConversionINR0.000.00INR Zero Only
3.13Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm (clamped with 1mm thick saddle) size on wall surface/pipe as required.40.000mtrsExcess(+)1Full ConversionINR0.000.00INR Zero Only
4Health Centre
4.01Supplying and drawing 3 x 2.5 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.40.000metreExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.02Supplying and drawing 3 x 4 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.150.000metreExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.03Supplying and drawing 3 x 6 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.25.000metreExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.04Wiring for circuit/ submain wiring alongwith earth wire with the 4 x16 sq.mm + 2 x 6 sq.mmof FRLS PVC insulated copper conductor, single core cable in surface/ recesssed medium class PVC conduit as required. 9.000metreExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.05Supplying and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.125.000metreExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.06Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.60.000metreExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.07Supplying and fixing of 32 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.8.000metreExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.08Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular switch socket outlet and 15/16A modular switch , connections etc. as required.3.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.09Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.15.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.1Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.11Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.12Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.13Supplying and fixing 4 pole MCB metal enclosure on surface / recess, complete with earth bar, din bar, detached gland plate, interconnection, phosphetized and powder painted including earthing etc. as required.2.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.14Supplying and fixing 25A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.15Supplying and fixing 63A rating, Four pole, (Three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.16Supplying and fixing single pole blanking plate in the existing MCB SB complete etc.as required.)22.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.17Supplying of one number 3.5 C x 70 Sq.mm size Aluminium conductor XLPE insulated PVC sheathed power cable of 1.1 kV grade etc. as required.20.000metreExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.18Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of above 35 sq. mm Upto 95 sq. mm (clamped with 1mm thick saddle) size on wall surface/pipe as required.20.000metreExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.19Supply and laying of one number of 8 SWG good quality bare copper wire for loop earthing along with existing XLPE insulated aluminium cable as required.32.000metreExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.2Supply and making end termination with brass compression gland and aluminium legs for 3.5 C x 70sq.mm (32 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.spacing not exeed 50 cm etc. as required.2.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.21Supplying and fixing 3 phase 8 way(4+24) , double door, vertical type three pole and neutral ,sheet steel,MCB distribution board,415 V on suface/recess mounting, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB etc)1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.22Supplying and fixing 63 A rating, 415 V, 10kA, "C" curve miniature circuit breaker suitable for inductive load of four pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.23Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.24Providing and fixing 125 A, 36 KA, FPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,making connections ,etc.as required.1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.25Supplying and fixing 63 A rating, 415 V, 10kA, "C" curve miniature circuit breaker suitable for inductive load of three pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.26Charges for removing the old wall mounted DB's, making good the damages of the wall/ floor including painting, dismantle the DB and other accessories without any damage and conveyance of the material to the godown etc, as required.2.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.27Supplying and making end termination of suitable size for the submain wiring with suitable lugs for 4 x 16 + 2 x 6 sqmm of PVC insulated copper conductor.2.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.28Supplying and fixing 20/25 A modular DP switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.4.000NosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.29Supplying and fixing 3 pin 25 A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.4.000NosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.3Supplying and fixing 1/2 module, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8.000NosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.31Supplying and fixing 3 phase 6 way , double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB etc)1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.32Charges for cleaning and spray painting the existing Panel board of 180 x 95 x 40 or nearest size with two coats of suitable colour (Grey) paint, over a coat of primer in installed position and marking the identification of switches with white paint etc, as required1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.33Fabrication & fixing of 123 x 93 cm panel board Sheet made from 2 mm thick MS sheet, powder coated in suitable colour over a coat of primer, providing rubber beadings and suitable size hinches, Nuts & Bolts for fixing on the existing panel board etc. as required.1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
4.34Fabrication & fixing of 94 x 42 cm panel board Sheet made from 2 mm thick MS sheet, powder coated in suitable colour over a coat of primer, providing rubber beadings and suitable size hinches, Nuts & Bolts for fixing on the existing panel board etc. as required.1.000nosExcess(+)1Full ConversionINR0.000.00INR Zero Only
Total in Figures0.000.00INR Zero Only4Construction of chamber for 100mm sluice platesitem510Nos
Quoted Rate in FiguresSelect0.00000.0000 Zero Only
Quoted Rate in WordsINR Zero Only